WHAT IS SPKA?

Replacing
Computerized
Monitoring
System (CMS)

Automatic Relay of Alarm


⮚ Too many false
SPKA All designated premises
alarm
⮚ JBPM staf take too
(SISTEM shall be connected
long to verify the
electrically or by telephone
PENGAWASAN to nearest fire station
general alarm
KEBAKARAN ⮚ CMS service
bypassing the switch board
AUTOMATIK) provider refuse to
to provide immediate and
upgrade or solve
automatic relay of alarm in
the issues
case of emergency.

Referring to Fire
Services (Act Facts : 130,991 alarm were triggered
341) (Designated : 2,954 were filtered by iScada
Premises) order https://www.facebook.com/KPKTMalaysia/photos/satu-lagi-infografik-
1998 Para 3 jawapan-parlimen-yang-menyentuh-hal-berkaitan-sistem-spka-
i/2277436072329288/ (2018)

iSnet Centre
B7-2-10, B7-3-10, B7-3A, 10, Jalan Teknologi 2/1E, Kota Damansara, 47810
Petaling Jaya, Selangor
iSCADA@iSnet COMPANY BACKGROUND

✔ iSnet was established on January 2009 by Dato’ Saipuddin Bin


Ahmad . iSnet flagship product, SPKA enables operate at facilities
across the country, allowing users access to Supervisory Control and
Data Acquisition from any location at any time.

✔ iSCADA Net provides their own control room which manage two type of
alarm; genuine alarm and false alarm.

✔ For general alarm, it will be assessed either it is genuine or false alarm


within 60 seconds.

SPKA Contract

5 Years : 12th December 2015 until 16th December 2020


Interim Period: 17th December 2020 until 24th October 2021
3 Years : 25th October 2021 until 24th October 2024

References;
1. Penyata Rasmi Parlimen, Parlimen Keempat Belas Penggal Kedua Mesyuarat Pertama
2. https://isnet.my/
HOW IT WORKS
SCADA? iSCADA?

To have effective and timely


decisions can be made and To allow SCADA to be
acted upon. monitored and control in real
time from any location

SCADA iSCADA

SCADA (Supervisory Control and Data


Acquisition)technology that provides the means to
monitor and control distributed system from a To allow SCADA to be monitored
central location. and control in real time from any
location

Data are being able to be delivered


virtually to any devices regardless of
distance.
*Using internet as medium to transfer
data which is already matured
technology.

References : https://aito.com.my/iscada-
ARCHITECTURE OF SPKA

SPKA Panel
*If subscribed to
iBase Monitoring

TCP/IP - Transmission Control Protocol/Internet Protocol


SPKA@PENANG INTERNATIONAL AIRPORT
CONCLUSION - HOW
CAN WE MAKE GOOD
OF IT?
CONLUSION

S
STRENGTHS
W
WEAKNESS
O
OPPORTUNITIES
T
THREATS

• Data are being able to be • Rely solely on Main Fire Alarm • Use TPS/IP as backup • Internet interuption
delivered virtually to any to trigger signal – malfunction • Add base app for client for • iSnet control centre went
devices regardless of distance. – manually call? iSnet call
better feature. Can update offline/on fire. Alternate?
• Using internet as medium to centre or MERS 999? Which
using interactive user
one provides agencies faster • Staff competency. Do 60
transfer data which is already interface.
respond? seconds KPI meet as stated in
matured technology. • Secondary SPKA fire alarm Parliament?
• No indicator SPKA panel
• System require minimum setup panel that link to Main Fire
malfunction • Cyber attack – stand alone
and can be linked to existing Alarm Panel
control centre
Main Fire Alarm panel • FCR on fire? No backup system
• To share and train client on
• Use SMS platform which can on ground
how the system works and how
be access by everyone. to react when the system alarm
triggered

As conclusion, although JBPM have allowed iS.net to continue


contract until 2024, there is still a few improvement can be
made/add into a system. The IT technology are keep evolving
and this system should keep up because the technology were
already invented and being used by others.