Professional Documents
Culture Documents
Pioneered Invented VESDA – VESDA Laser Invented VFT-15 OSID – Dual VESDA VLI – ASD for VESDA-E VEU –
aspirating smoke very early warning Series – world’s addressable wavelength open air harsh & industrial Redefining & setting
detection (ASD) smoke detection leading ASD brand VESDA ASD smoke imaging environments new Benchmark for
ASD
Air Sampling
Image
Processing
Over 100 New
Patents During
VESDA-E
development*
Optics
VESDA-E VEP
Interpretation
of Light
* Filed, Pending or Awarded
VEP-A00-1P
Single Pipe VEP with LED’s Display
VEP-A00-P VEP-A10-P
with LED’s Display with 3.5” Display
VESDA Analytics
Backward Compatibility
VESDA Analytics
Backward Compatibility
VESDAnet
• Provides access point to entire
VESDAnet network with iVESDA or
VSM4
Seamless Retrofit
12
Fire 1 Threshold 0.015%/m 0.01%/m 1.5 times the sensitivity for earlier warning (and with minimum nuisance alarms because
(0.0046%/ft) (0.003%/ft) of Flair)
Pipe Length 80m (260ft) 100m (328ft) Longer pipe runs allow greater flexibility and convenient detector mounting to reduce
(Linear / Branched) 100m (328ft) 130m (427ft) cost of maintenance
Sampling Holes 30/36/40 30/40/45 Improved detection technology increases the number of sampling points for improved
(A/B/C) coverage
General Purpose 1 2 With an extra GPI there is greater flexibility in control. Both GPIs are programmable (one
Input monitored typically for PSU monitoring) for greater flexibility.
Relays 3 7 More relays allow greater flexibility in reporting multiple alarm fault conditions
Analytics None DieselTrace, Targeted detection for integration with business process for effective response and to
DustTrace, save cost
WireTrace
StaX None PSU Future proof expandability protecting end-user initial investment
Connectivity Serial USB, Ethernet, Wi-Fi World class connectivity for unprecedented ease of monitoring and maintenance
Fully Field Partial Yes Reduced service and maintenance time and cost as key sub-assemblies are
Replaceable interchangeable in the field
AutoLearn Smoke Smoke and Flow In addition to Smoke; VEP learns the flow conditions and sets individual sample pipe flow
thresholds to accommodate varying environmental conditions
Non-volatile No Yes Retention of event log upon loss of power enabling later retrieval of events for expedient
Memory troubleshooting and configuration
Fire 1 Threshold 0.015%/m 0.01%/m 1.5 times the sensitivity for earlier warning (and with minimum nuisance alarms because
(0.0046%/ft) (0.003%/ft) of Flair)
Pipe Length 4 x 50m (4 x 164ft) 4 x 70m (4 x 230ft) Longer pipe runs allow greater flexibility and convenient detector mounting to reduce
(Linear / Branched) 400m (1,312t) 560m (1,837ft) cost of maintenance
Sampling Holes 30/60/100 40/80/100 Improved detection technology increases the number of sampling points for improved
(A/B/C) coverage
General Purpose 1 2 With an extra GPI there is greater flexibility in control. Both GPIs are programmable (one
Input monitored typically for PSU monitoring) for greater flexibility
Relays 7 7 Identical relay configuration and placement for ease of upgrade. Simply unplug the VLP
wires and reconnect to VEP!
Analytics None DieselTrace, Targeted detection for integration with business process for effective response and to
DustTrace, WireTrace save cost
StaX None PSU, Auto Pipe Clean Future proof expandability protecting end-user initial investment
Connectivity Serial USB, Ethernet, Wi-Fi World class connectivity for unprecedented ease of monitoring and maintenance
Fully Field Partial Yes Reduced service and maintenance time and cost as key sub-assemblies are
Replaceable interchangeable in the field.
Display LED 3” LCD Touch screen display provides more intuitive and more informative status information
AutoLearn Smoke Smoke and Flow In addition to Smoke; VEP learns the flow conditions and sets individual sample
pipe flow thresholds to accommodate varying environmental conditions
Area Coverage VEU can provide considerably larger area coverage as allowed by
2,000m2 6,500m2 system design and regulatory requirements. VEU will considerably
(21,528 sq. ft) (96,640 sq. ft)* reduce the installation cost due fewer detectors, power supplies,
batteries, cabling and labour.
Fire 1 Threshold VEU provides 10 times higher sensitivity than VEP resulting in
0.01%/m 0.001%/m earlier warning in mission critical facilities such as Clean Rooms
(0.003% obs/ft) (0.0003% obs/ft)) preventing smoke damage and ensuring business continuity.
Pipe Length Linear Linear Longer pipe runs allow greater flexibility and increased coverage in
(Linear / 4 x 70m 4 x 100m high ceiling applications whilst allowing convenient detector
Branched) (4 x 230ft) (4 x 328ft) mounting to reduce the cost of maintenance.
Branched Branched
560m 800m
(1,837ft) (2,624ft)
Sampling Holes 40/80/100 80/80/100 VEU provides double the number of Class A sampling holes
(A/B/C) considerably increasing the coverage in high airflow applications.
Applications Focus
Applications Detector Higher Stability Dust Longer VESDA iVESDA TCO Value Prop
Sensitivity of Rejection Pipe Analytics
Detection run
VEU VEP
Longer pipe run on both VEP and VEU are ideal for
tunnels applications. Downloading Analytics allows
Tunnels providing additional information like the existence of
wire smoke.
No. Relays 3 3 7 7 7 7
USB, Ethernet, USB, Ethernet, USB, Ethernet,
Connectivity Serial Serial Serial
Wi-Fi Wi-Fi Wi-Fi
Xenon Introduced Laser Products VLF & VLS VFT-15 VLI OSID VLC-EX & ECO VLF VESDA-E VEU VESDA-E VEA
Support Material
Document Document Number
Technical Datasheet 22063
Q&A 26841
A New Beginning…