You are on page 1of 5

Outgoing Inspection

Rejection
18th October 2022
ATC CLEANTEC SDN. BHD.
Outgoing Inspection Rejection
Customer: FASONS HOLDING SDN. BHD.
Process : ALCONOX ULTRASONIC CLEAN
P/N : M-YVM-P3-7X3-1053
Material : Copper
Affected Quantity: 10/50 pcs.
Acceptance Criteria: No stain found under the UV light inspection

ATC CLEANTEC SDN. BHD. 2


Outgoing Inspection Rejection

White Light Inspection


ATC CLEANTEC SDN. BHD. 3
Outgoing Inspection Rejection

UV Light Inspection

ATC CLEANTEC SDN. BHD. 4


Outgoing Inspection Rejection
Solution:
1. The parts were reworked by immersing in the ultrasonic
acetone for 10 mins.
2. After ultrasonic acetone, the stain had been remove
completely.

Conclusion:
Acetone is a good solvent for dirt and stain cleaning.

ATC CLEANTEC SDN. BHD. 5