You are on page 1of 44

Introduction of SEWind W1250 Operat

ion and Trouble shooting

25.11.2008

2006 年 3 月 11

Mita control cabinet

Nacelle

Fiber optic

Control cable

tower
The controller includes I/O and Com-Ports. It is
expandable with different extension interfaces to
get more I/O or communication interfaces.

The programming of the WP3100 is programmed


in language „C“ and can be uploaded
respectively updated with a PC.
WP3100

Basic configuration

Insert some functional board


In our controller, we have the following functional board

WP3023 is an extension card with digital inputs


and outputs.

The card has 13 digital inputs and 8 digital outputs.


All outputs are short circuit protected.

WP3034 is a 4-channel analogue input circuit board


The WP3034 collect the blade angle and the wind
direction.
WP3035 is a 4-channel analogue output circuit board
The WP3035 controls the pitch control valve, the
planned performance and the setpoint value
cosφ of the converter.

WP3045 is a standard interface for optical fibre


communication. It is used for converting 5V
CMOS signals into fibre optic serial
communication signals.
The WP3045 is used for the display and park
communication.
WP3046 is a standard RS232 communication card
used for safe serial communication. The card
includes onboard lightning and over voltage
protection. The baud rate is changeable.
The WP3046 is used for the modem and PC
communication.

WP3042 The WP3042 is a standard RS485


communication card.
The card includes an onboard lightning and over
voltage protection. The baud rate is
changeable.
The WP3042 is used for the communication between
WP4084 (vibration sensor) and WP3100.
The WP3050 graphic
display is used with
the WP3100
controllers to
monitor the data of
the WEC. Also the
complete access to
the controller is
realised by the
WP3050.
The start menu shows the actual operating
mode of the WEC.
Amongst others the following values can to
be read off directly:
-Power
-Speed
-Operating mode
-Access rights
-Active status

The actual active status codes can be


displayed in a submenu of the start menu.
The status menu includes the
following informations:

-System
-Generator
-Hydraulic
-Yaw
-Weather
-UPS
-Temperatures
-Pitch
-Communication
-Park control system
-Inputs
-Outputs
-WP4084 (vibration sensor)
-Revolution speed
In the grid menu includes the
following informations:

Data of the total grid of the WEC


(current, voltage, power, frequency
and power factor)

Data of the single phases L1, L2 and


L3 of the WEC (current, voltage and
phase angle)
The status menu includes
amongst others the following
informations:

-Control system
-Operating control
-Yaw control
-Pitch control
-Hydraulic control
-Grid control
-Speed control
-Input control
-Output control
-Status control
-Temperature control
-WP4084 control
-Passwords
The status code list shows the
last 100 status codes with the
following informations:

-Status list number


-Time stamp of status code
-Time of reset the status code
-Status code number
-Text of status code
In this menu is shown
following information of each
status code:
-Status code number
-Status code name
-number of status code entry
The occurrence list includes the
following informations of the WEC
(last 100 entrys):

- occurrence number
- Date and time
- occurrence name
The access list shows the last 100
accesses with the following
informations:
-Date and time of access
-level of access rights
-User ID-number
-Remote or direct access
-Login or logoff status
This menu shows the serial
number and the version of the
application program.
Furthermore it is shown the serial
number of following components:

-WP3101
-WP3050
-WP4084 + revision
In this menu it is specified whether
and which digital and analogue values
are to be recorded by the controller by
emerging of a presetted status code.
Furthermore a 24h-record of selected
analogue and digital values can be
adjusted.
In this menu the manual activation
of some actors is possible (valves,
motors respectively pumps).
Also it is possible to control the
WEC manually.
Furthermore the simulation
respectively the control of some
converter functions is possible.
A test output can be adjusted
between 4 and 20mA can be
adjusted.
The heatings of the wind sensors as
well as the generator heating is to be
controlled by this menu manually.
It is furthermore possible to actuate a
manual alarm call.
WPshell

monitor
software WPMS

Gateway
WPshell
WPMS
Gateway
Trouble shooting

Sample 1
Sample 2
Sample 3
Thank you for your attention

You might also like