You are on page 1of 5

Section 2

ACC Systems and Functions

EDC TOMBALL, TEXAS


SECTION 2
2.1
1. ACC Functional Operation
2. Operation Series
3. How does ACC work?

2.2
1. General Description 35-8-5 RAM/ACC II
2. BJ Dwg. D 47714-1 35-8-5 (3305/ACC-II), System Diagram
3. BJ Sketch ADC022 35-8-5 ADC Hydraulic Schematic
4. BJ Dwg. D 48550-1 Hydraulic System Ass’y, ACC Kit, 35-8-5 RAM
48550-2 Pumping Skid
48550-3 Power Unit
48550-4 Pumping Skid
48550-5 RAM Tank/Power Unit

2.3
1. General Description SCP-348 (3305/ACC-II)
2. BJ Dwg. D 59851-1 348 (3305/ACC-II), System Diagram
59851-2 348 (3305/ACC-II), System Diagram
3. BJ Dwg. D 61968-1 to 14 Hydraulic System Ass’y, SCP-348/RAM

2.4
1. Sixty Tooth Gear and Drawing
2. BJ Dwg. D 127716 Magnetic Pick-up Ass’y, Pacemaker Pump Drive

2.5
1. Water Valve Potentiometer and Actuator (SCP-348, 35-8-5/RAM/ACC)
2. Water Valve Ass’y Drawing
3. BJ Dwg. C 49121 Potentiometer Ass’y, Stonel #MQ3VE1C
4. BJ Dwg. C 49701 Valve Ass’y, Ball 2”, Jamesbury w/Hydraulic
Actuator
5. BJ Dwg. D 56832 Manifold Ass’y, Mix Water, 35-8-5/ACC
6. BJ Dwg. D 64548-2 Manifold Ass’y Mix Water, SCP-348/RAM
64548-3 Manifold Ass’y Mix Water, SCP-348/RAM
7. Fax Transmission-Changing and Setting New Water Valve
8. Water Flow Meter (SCP-348, 35-8-5/RAM/ACC)

07/20/23

EDC TOMBALL, TEXAS


2.6
1. Mixing Module and Knife gate (SCP-348, 35-8-5/RAM)
2. BJ Dwg. D 57686-1 Valve Ass’y, Knife Gate-6” Wey Valve “VL” Series
57686-2 Valve Ass’y, Knife Gate Wey Valve “VL” Series
3. Hydro-line Dwg. 1Q9603-0081-01, Data Sheet
4. Manual Override

2.7
1. Bulk Valve Potentiometer and Actuator (SCP-348, 35-8-5/RAM/ACC)
2. Bulk Valve Drawing
3. BJ Dwg. C 57520, Valve Ass’y Norris 5” Butterfly w/ Parker Hydraulic
Actuator
4. SCP-348, 35-8-5/RAM/ACC Load Cells
5. Strainsert Load Cell (SCP-348) Data Sheet
6. Load Cell Position (SCP-348)
7. Beowulf Load Cell (35-8-5/RAM/ACC) Data Sheet

2.8
1. Dual Densimeters
2. BJ Dwg. D 42172-1, Densimeter Assembly, DB-IV (Electronic)
42172-2, Densimeter Assembly, DB-IV
42172-3, Densimeter Assembly

2.9
1. BJ Sketch ADC010 and Servo Valve
2. BJ Sketch ADCOO8, (outside) Servo Box 35-8-5/RAM/ACC
3. Servo Box and drawing (inside) 35-8-5/RAM/ACC
4. Servo Box connections 35-8-5/RAM
5. BJ Dwg. D 49148-1, Box Ass’y, 35-8-5 and 148 control
49148-2, Box Ass’y, 35-8-5 and 148 control
6. BJ Sketch ADC009, (outside) Servo Box SCP-348
7. Servo Box and drawing (inside) SCP-348
8. BJ Dwg. D 49148-2-1, Box Ass’y, 348/Control
49148-2-2, Box Ass’y, 348/Control
9. Servo Valve Null Point Adjustment Procedure
10. Sundstrand KVF Series Servo Valve, Data Sheet

07/20/23

EDC TOMBALL, TEXAS


2.10
1. Control Module
2. BJ Dwg. D 49207-1, Module Ass’y, Density Controller ACC II(Front)
49207-2, Module Ass’y, Density Controller ACC II (Back)
3. BJ Dwg. C 56164, Cable Ass’y, Power Splitter (DC)
4. BJ Dwg. C 47643, Cable Ass’y, Pressure (90 degrees one end)
5. BJ Dwg. C 35838, Cable Ass’y, Flow (1 conn.) Mag Pick-up

6. BJ Dwg. C 39540, Cable Ass’y, Pressure (6 cond.) Offshore


7. BJ Dwg. C 39542, Cable Ass’y, Flow (Offshore)
8. ACC II Screen Types
9. ACC II Control Panel
10. ACC II Back Panel Connections
11. Keypad Key Definitions
12. Explanation of Main Screen on ACC Module
13. ACC II Function Definitions
14. ACC II Key Definitions

2.11
1. ACC II Programming the Job
2. Programming BATCH Stage
3. Programming STAGE 1
4. Setting Ramp and Freeze Times
5. Reviewing the Programmed STAGES
6. Zeroing the DBIV Densimeter
7. Calibrating the Bulk Load Cell
8. Performing Slurry Operations

2.12
1. Introduction Sheet PID Basics - Proportional/Integral/Derivative
Control
2. Factory (Defaults) Presets
3. Calibration Menu
4. Utilities Menu
5. ACC II Module Screens

07/20/23

EDC TOMBALL, TEXAS


2.13
1. Troubleshooting: Water Valve “Does not work in MANUAL”
2. Troubleshooting: Water Valve “Works in MANUAL, but not in AUTO”
3. Troubleshooting: “Water valve is erratic”
4. Troubleshooting: Bulk Valve “Does not work in MANUAL”
5. Troubleshooting: Bulk Valve “Works in MANUAL, but not in AUTO”
6. Troubleshooting: “Bulk Valve is erratic”
7. Troubleshooting: Knife gate “Does not work in MANUAL”
8. Troubleshooting: Knife gate “Works in MANUAL, but not in “AUTO”
9. Troubleshooting: “Knife gate is erratic”10. Troubleshooting: Valve
10. Position drifts with Hydraulic Power and ACC turned off
11. Troubleshooting: Loss of Bulk Supply
12. Troubleshooting: Loss of Water Supply
13. Troubleshooting: Loss of Knife Gate Control

07/20/23

EDC TOMBALL, TEXAS

You might also like