You are on page 1of 5

SOLDERABILITY TEST – EXPIRED MATERIAL

1. Material information

Row Labels HW Date code Telit quality direction

perform solderability solderability test on both sides:


1FF0102018.03 3990401814 2117/2122 Fih interface: solderability test
End customer side: solderability test after reflow, baking
SOLDERABILITY TEST – EXPIRED MATERIAL

2. Factory interface
2.1 Process flow

Check material Solder printing VQ Reflow Result

2.2 Result

1FF0102018.03
Solder paste before reflow Solder paste after reflow
Date code: 2117

Bag 1

Bag 2

 Conclusion: Solder cover over 95% copper pad  OK


SOLDERABILITY TEST – EXPIRED MATERIAL

2. End customer interface


2.1 Process flow

Reflow 2nd Baking 16h Solder printing VQ Reflow Result

2.2 Result

1FF0102018.03
Solder paste before reflow Solder paste after reflow
Date code: 2117

Bag 3

Bag 4

 Conclusion: Solder cover over 95% copper pad  OK


SOLDERABILITY TEST – EXPIRED MATERIAL

2. Factory interface
2.1 Process flow

Check material Solder printing VQ Reflow Result

2.2 Result

1FF0102018.03
Solder paste before reflow Solder paste after reflow
Date code: 2122

Bag 1

Bag 2

 Conclusion: Solder cover over 95% copper pad  OK


SOLDERABILITY TEST – EXPIRED MATERIAL

2. End customer interface


2.1 Process flow

Reflow 2nd Baking 16h Solder printing VQ Reflow Result

2.2 Result

1FF0102018.03
Solder paste before reflow Solder paste after reflow
Date code: 2122

Bag 3

Bag 4

 Conclusion: Solder cover over 95% copper pad  OK

You might also like