You are on page 1of 10

Maritime University of the Caribbean.

Spring Marine Management.


Professional Internship.
MT- Kizomba.

LIFE SAVING APPLIANCE / FIREFIGHTING EQUIPMENTS.

CAPTAIN: DCDT:
Sanchez C. Landaeta Ramón
CHIEF OFFICER.
Zamora M.
CHIEF ENGINEER.
Miceli M.
MT KIZOMBA.
•FLAG:…………………………………………………………. LIBERIA.
•PORT OF REGISTRY:………………………………… MONROVIA
•CALL SIGN:…………………………………………………. D5NR3
•IMO N·:……………………………………………………… 9433901
•TYPE OF SHIP: …DOUBLE HULL OIL & CHEMICAL TANKER.
•DELIEVERY:………………………………………………….2009

•LOA: …………………………………………………………..183.31M
•BREADTH MOULDED: …………………………………32.20MTH
•DEPTH MOULDED: …………………………………… 19.10M
SOLAS.

LIFE SAVING APPLIANCE FIREFIGHTING EQUIPMENT


1794

CHAPTER III: CHAPTER II-2:


Contains the requirements for life-saving appliances Fire protection, detection and extinction of firetinction

1.2.2.5 LSA CODE


LIFE SAVING APPLIANCE

PERSONAL LIFE-SAVING APPLIANCES: -


Lifejackets
- Life-ring
- Immersion suits.

VISUAL SIGNALS
- Rocket parachute flares
- Hand flares
- Buoyant smoke signals

SURVIVAL
- Life boat
- Liferaft
- Line-throwing
- Embarkation ladder

SEARCH AND RESCUE:


- SART
- EPIRB
FIREFIGHTING EQUIPMENTS
EQUIPMENTS:

- Fire Hose and Nozzles


- Fire Hydrants
- Portable Fire Extinguishers ( CO2, FOAM , DRY POWDER,WET CHEMICAL)
- CO2 System
- Monitors
- SCBA
- EEBD
- Fire blanket
- Foam applicator
- Water Sprinkler / Water imst
3. THE FLOW OF EACH PROTECTED AREAS
Water Mist Protected areas
Nozzle type Total Flow
x pes (l/min)
Main Engine HL x 9 126
No.1,2 G/E LL x 4 60
1. Applied Rule &
No. 3 G/E LL x2 30
Regulation.
• SOLAS Ch. 111-2, Reg. 10.5.6
Aux. Boiler LL x 1 15
H.F.O Purifier LL x 2 30
Incinerator LL x 1 15
I.G.G ELL x 1 33
2. REQUIRED FRESH WATER Total nozzle Q´ty HL : 9 Sets LL : 10 Sets ELL : 1 Set
QUANTITY.
Max. Total Flow x 20min x 120% (allowance)
=1261/min x 20 x 1.2 = 3,024 liter ≡ 4m³ 4. WATER MIST PUMP CAPACITY.
A. Required Flow ≥ Max total Flow = 1261/min ≡ 8m³/lt
B. Required pressure = Nozzle desing presure + Max pressure drop
= 8 + 0.802 = 8.802bar
C. Pump model: CALPEDA MXV 40-807-60 ( 133,31/min X 101m X 5.5 kW
Fire pump and
emergency fire
pump
•Start is posible from
following locations:

1. Bridge.
2. Foam room ( fire station)
3. Switchboard in steering
room.
4. Locally from area where
pump is located.

• Bilge fire & g/s pump


CO2 FIRE •The fire Extinguishing system extinguishes the fire by means
EXTINGUIS of carbon dioxide gas. The system consists essentially of CO2
cylinders main isolating valve(s) manifold, CO2 nozzles in
HER compartment protected and pipe lines connecting these
main parts.
SYSTEM
THANK YOU.

You might also like