SECURE POWER SOLUTION

SECURE POWER DIVISION – SCHNEIDER ELECTRIC

Gege Raharjo
VTI Technical Consultant – APC by Schneider

Confidential Property of Schneider Electric |


185 years of history
1999 2010
Groupe Schneider becomes Acquisition of Areva’s distribution activity (in
Schneider Electric, process)
focused on Power & Control 2008
Acquisition of
Xantrex
1996
2007
Modicon, historic leader in Automation,
becomes a Schneider brand Acquisition of APC corp. and Pelco
1836 2005
Creation of Schneider 1991 Acquisition of
at Le Creusot, France Square D joins Groupe
Power Measurement Inc.

Schneider 2003-2008
Targeted acquisitions in wiring devices and home
1988 automation
(Lexel, Clipsal, Merten, Ova, GET, etc.)
Telemecanique joins Groupe
Schneider 2003
Acquisition of
T.A.C
1975
Merlin Gerin joins Groupe 2000
Schneider Acquisition of
MGE UPS Systems

19th century 20th century 21st century


Long Journey of Schneider Electric Indonesia
Schneider Electric in Indonesia
Leading the digital transformation of energy management and automation Schneider Electric Indonesia
in homes, buildings, data centers, infrastructure, and industries. Cibis 9 Building, Jalan TB Simatupang No. 2
Cilandak, 12560 Jakarta

www.se.com/id

Established 1973
~4500 employees
Smart factories serving global / regional / local markets
• Batam (3 plants) – Transactional / products
• Cikarang – MV / LV equipment, LV adapted offers
2019 Indonesia 4.0 readiness trophy winner from R.I. President
Major sites
Jakarta, Batam, Cikarang,
Education / Vocational school (SKM) National Partner
Delivering state of the art training to Indonesian youths
Main office Distribution center Field / sales offices Manufacturing facilities

© 2019 Schneider Electric. All Rights Reserved I Page 4


Schneider Electric - Secure Power Division product
Product Solutions……

NetShelter SX
UPS RACK System
Cooling CRAC

Access Floor & Under Floor


Air Distribution for Comfort
Monitoring SW
Applications
Confidential Property of Schneider Electric | Page 5
Schneider Electric - Datacenter Solution
Enterprise Turnkey Solution
Network Connectivity
& Cable management
HV/MV & MV / LV
Transformers

MV and LV Switchboards Rack Systems


& Switchgears Power monitoring &
Energy Mgmt Software

Modular UPS Containment


System
Sensors&
Meters Precision cooling
InRow / Downflow
Busway

Software &
Analytics Chillers
Energy Automation

VSD Control

Modular UPS Lighting Access Control,


& PDU Control CCTV

Confidential Property of Schneider Electric | Page 6


Today Agenda

ECOSTRUXURE IT

UPS SYSTEM

COOLING SYSTEM

RACK SYSTEM

INDUSTRY APPLICATIONS
Connected Solutions

EcoStruxure™ Architecture

Building Data Center Industry Infrastructure

Apps, Analytics & Services


EcoStruxure IT Advisor EcoStruxure Asset Advisor
Cybersecurity
Cloud and/or
On Premise
End to End

Edge Control
EcoStruxure IT Expert

Connected Products
Prefabricated infraStruxure InRow Micro Data HyperPod APC APC rPDU Symmetra Galaxy
IT, Power, Cooling Center Xpress Netshelter Smart-UPS UPS UPS

EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure


Building Power IT Machine Plant Grid

Confidential Property of Schneider Electric | Page 8


Monitoring Critical Infrastructure
StruxureWare Data Center Expert

Overheat From Reactive to Proactive


Water Leak
Power Problem * Real-time Event Notification
UPS Problem * Minimizes response time to
Cooling Problem Humidity critical physical Infrastructure
Intruder situations
etc Temperature * Enables Operation team to
Power
reduce MTTR
* Improve efficiency and
Maximize uptime

Water Leak
DC, Branches, Remote site Surveillance

Fire Access Control


Cooling
Maintenance Team

Monitoring Room Send Alarm via SMS, Email, Beacon


Create Visibility & Predictability
Custom Dashboard
ECO CIM
Next Topic

ECOSTRUXURE IT

UPS SYSTEM

COOLING SYSTEM

RACK SYSTEM

INDUSTRY APPLICATIONS
DESIGN & POSITION OF UPS

Utility Power

ATS
UPS Critical Load

UPS Not A Primary Electrical Resource


Generator

Confidential Property of Schneider Electric | Page 13


CRITICAL LOAD

“Critical load based on Basic, Situation dan Needs”


APC UPS Product Range

Volt - Amps 20,000

10,000 Smart-UPS Symmetra


RT & SRT RM and LX
1-20 2-16
5,000 kVA kVA
Smart-UPS
SMT Smart-UPS
1,000 Back-UPS
Smart-UPS 750-5000
SC / SMC
SMX
500-1500 VA 750-3000
420-3000 VA
VA
VA
500
Home / Small Office Network Room

Confidential Property of Schneider Electric | Page 15


Single Phase Business Power Portfolio
Power availability and management for entry-level to high-performance servers, storage and business
networking systems
Home/Home-office Small-Medium Business
Enterprise

Smart-UPS
Smart-UPS
On-Line Symmetra
Feature Set

1kVA - 20kVA 2kVA - 16kVA N+1

Smart-UPS X
750VA – 3kVA

Smart-UPS
750VA - 5kVA
Smart-UPS C
420VA - 3000VA

Application Size
Confidential Property of Schneider Electric | Page 16
UPS 3 Phase
Full UPS Portfolio

HYPER MODULAR
Modular & Scalable UPS’s
to ease operation and
upgradability Symmetra PX48 Symmetra PX96/160 Symmetra PX250/500
(16 to 48kW) (16 to 160kW) (25 to 500kW)

OPTIMUM
Drive the Market through
innovation
Galaxy VS Galaxy VM Galaxy VL Galaxy VX
(20 to 150kVA) (160 & 200kVA) (250 & 500 kVA) (500 to 1500kW)

MEDIUM
Reach basic requirements of the
Market
EASY UPS 3S EASY UPS 3M EASY UPS 3L
(10 to 40kVA) (60 to 200kVA) (250 & 600 kVA)
Next Topic

ECOSTRUXURE IT

UPS SYSTEM

COOLING SYSTEM

RACK SYSTEM

INDUSTRY APPLICATIONS

Confidential Property of Schneider Electric | Page 19


| 2017 Indonesia Partner Bootcamp Training
Comfort Versus Precision Cooling
Precision Comfort
Application Technical Human
Nominal Unit Size 5-130 kW 2-30 kW
% Sensible Heat 85-100 % 50-70 %
Control Accuracy +/- 0.5 C, +/- 1-3% RH +/- 1-2 C
Humidity Regulation Controlled Humidity Unregulated Dehumidification
Air Volume 5,000-30,000 m3/h 300-2,000 m3/h
Air Outlet Speed 2-3 m/s 0.2-0.5 m/s
Noise Level in Room 45-70 dB(A) 20-40 dB(A)
Unit Customisation High Low
Operator Control Complex Simple
Operation Permanent Need based
Refresh Frequency Low, as needed High

Confidential Property of Schneider Electric | Page 20


Types of Cooling Systems
Types of Air Conditioning Systems

1. Air Cooled

2. Water Cooled

3. Twin Cooled

Schneider Electric – IT Business – Cooling LOB


Air Cooled System
with Vertical Air Discharge

Air Conditioning
Unit

Air Cooled
Condenser

Schneider Electric – IT Business – Cooling LOB


Water Cooled System
with Cooling Tower

Cooling
Tower

Air Conditioning
Unit

Schneider Electric – IT Business – Cooling LOB


Twin Cooled System
DX Air Cooled / Chilled Water

Air Cooled
Air /water Cooled Chiller
Condenser

Schneider Electric – IT Business – Cooling LOB


Types of Air Distribution
Airflow Configurations

UPFLOW

Bottom Suction Front Suction with


Front Suction with Rear Suction with
with Top Top Front Discharge
Top Discharge Top Discharge
Discharge (Plenum and Grille)
DOWNFLOW

Top Suction with Top Suction with


Bottom Bottom Discharge
Discharge (Plenum and
(Floorstand) Grille)
Schneider Electric – IT Business – Cooling LOB
Schneider Electric Cooling Complete Offer
Cooling Portfolio

Next Generation Room High Water Temperature Room


250/500 kW & Close Coupled DX Solutions
Air Economizer & Close Coupled Cooling

POD and Prefabricated Raised Floor & Under Floor


Aircooled & Watercooled Cooling Air Distribution for Comfort
Applications
Chillers
Confidential Property of Schneider Electric | Page 28
Downflow Cooling Product Range
InRow 300mm_ ACRC301S_CW InRow 600mm_ACRC600_CW

CW
300mm_ ACSC101_DX
InRow 300mm_ACRC301H_CW
InRow
Cooling DX
300mm_ ACRD101_DX

NEW 600mm_ ACRD600_DX Inverter

DX-Inverter
AM_SDCV/C – 5 models New _LE LDCV – 13 models _ Single/Dual coil

CW
New LE _HDCV / HT – 13 / 7 models _ Single/Dual coil

AM_SDAV/C – 6 models LE_TDAV/R – 16 models New _LE LDAV – 4 models

Downflow
Cooling DX
New _LE IXAV – 3 models

DX-Inverter
New LE _IDAV – 11 models

5KW Electric
Confidential Property of Schneider 10KW 15KW 20KW 30KW 40KW 50KW 60KW 70KW 80KW 90KW 100KW 140KW 170KW 250KW
InRow® Cooling Product Family_Gen2

Benefit: Places the cooler next to the heat source


 Energy and space efficient
 Simple and inexpensive
 Precise and powerful
 Small to large DC

Chilled Water: Standard and High Temp


(cools up to 8 racks)

Direct Expansion: Air/glycol cooled, self-contained


(cools up to 6 racks)

Cooling Unit
Next Topic

ECOSTRUXURE IT

UPS SYSTEM

COOLING SYSTEM

RACK SYSTEM

INDUSTRY APPLICATIONS
Rack Category
RACK POWER DISTRIBUTION
RACKS & ENCLOSURES RACK ACCESSORIES

Open Rack Closed ATS ENV LCD


Rack
PDU KVM

NSX NSV NCX Thermal


Managed Basic Power Cords Containment
PDU PDU

Metered Switched MBO with SWITCHING


Confidential Property of Schneider Electric 32
METERED-BY-OUTLET (MBO)
Eco Aisle HyperPod
RACK Netshelter SX

Confidential Property of Schneider Electric | Page 33


RACK CRITERIA….

A – AIRFLOW

P – POWER DISTRIBUTION 5 Years

C – CABLE MANAGEMENT

W – WEIGHT / LOAD CARRYING “Ease of use”


S – SECURITY
Flexibility &
Scalability
M – MANAGEMENT

L – LOGISTICS
Fits Like
AC – ADDITIONAL CRITERIA(UL) a Glove

Confidential Property of Schneider Electric 34


NetShelter ® SX – 1070 and 1200 mm deep
…sizes optimized to cover a wide range of applications

24U x 600mm 42U x 600mm 42U x 750mm 45 & 48U x 600mm 45 & 48U x 750mm
12U & 18U SX Cabinet Offering
AR3003 AR3003SP AR3103 AR3103SP AR3006 AR3006SP AR3106 AR3106SP

SKU Status Released! Released! Released! Released! Released! Released! Released! Released!
12U

18U

23.6"W (600mm)

35.42"D (900mm)

42.13"D (1070mm)
600lb (272kg) static/
dynamic weight capacity
900lb (408kg) static/
dynamic weight capacity
Shock Packaging/
ISTA tested

UL2416 Listed

Color-Black

Netbotz Compatible

Global Availability

All the standard features of the NetShelter SX in a smaller size!


Wall Mount Cabinets
Multiple Offers to be Launched in November

6U, 9U and 12U Horizontal Wall Mount 6U Vertical Wall Mount

Confidential Property of Schneider Electric | Page 37


NetShelter SX Enclosures
Sizes optimized to cover a wide range of applications
NetShelter SKU Height Width Depth Application
AR3100 42 600mm (24 in) 1070mm (42 in) Low-Med Density Servers
AR3200 42 600mm (24 in) 1070mm (42 in) 2 X 20U compartments for colocation
AR3300 42 600mm (24 in) 1200mm (47.5 in) Med-High Density Servers
AR3305 45 600mm (24 in) 1200mm (47.5 in) Med-High Density Servers
AR3105 45 600mm (24 in) 1070mm (42 in) Low-Med Density Servers
AR3107 48 600mm (24 in) 1070mm (42 in) Low-Med Density Servers
AR3307 48 600mm (24 in) 1200mm (47.5 in) Med-High Density Servers
AR3150 42 750mm (24 in) 1070mm (42 in) Netwworking and Blade Applications
AR3155 45 750mm (24 in) 1070mm (42 in) Netwworking and Blade Applications
AR3350 42 750mm (24 in) 1200mm (47.5 in) HD Netwworking and Blade Applications
AR3355 45 750mm (24 in) 1200mm (47.5 in) HD Netwworking and Blade Applications
AR1340 42 750mm (24 in) 1070mm (42 in) High Density Networking
AR3340 42 750mm (24 in) 1200mm (47.5 in) Very High Density Networking
AR3347 48 750mm (24 in) 1200mm (47.5 in) Very High Density Networking
AR3157 48 600mm (24 in) 1070mm (42 in) Neyworking and Blade Applications
AR3357 48 750mm (24 in) 1200mm (47.5 in) Neyworking and Blade Applications
AR3104 24 600mm (24 in) 1070mm (42 in) Remote Server Applications
AR3810 42 600mm (24 in) 825mm (36 in) Audio/Video Applications
AR3812 42 600mm (24 in) 825mm (36 in) Audio/Video Applications
AR3814 24 600mm (24 in) 825mm (36 in) Audio/Video Applications
AR3003 12 600mm (24 in) 900mm (35.42") Edge Applications
AR3006 18 600mm (24 in) 900mm (35.42") Edge Applications
AR3103 12 600mm (24 in) 1070mm (42.13") Edge Applications
AR3106 18 600mm (24 in) 1070mm (42.13") Edge Applications

Applications For Depth Applications For Width


Applications For Height
Schneider Electric
RACK Accesories

Confidential Property of Schneider Electric | Page 39


NetShelter SX Accessories
Horizontal and Vertical
Stabilization
Cable Management
Bolt-down brackets for UBC
Extensive line of options for
floor anchoring and anti-tip
vertical, horizontal and
plate for stand-alone
overhead cable management
applications

1U Toolless Airflow
Management
Recessed Rails
Blanking Panels Maximum flexibility for rack-
Modular toolless blanking mounting networking
panels allow for quick and equipment with servers in
easy installation to promote same rack
proper airflow

Shelving
Fixed and sliding shelves Overhead Cable
with weight capacities Management
ranging from 50-250 lbs. Provide overhead cable
(23-113 kg) management of power and
data cables in shielded
partitions

Schneider Electric Critical Power & Cooling Services – Amod Ranade – August 18, 2008
NetShelter SX Options and Related Products
Cooling Solutions Power Distribution
Fan products used to Diverse rack power distribution
minimize air mixing, offerings to meet the needs of
distribute cool air to entry-level networking
equipment, and remove equipment and high-density
heat from the rack or server environments
room
Monitoring & UPS
Management Rack-mount power protection
Centralized monitoring and solutions for data center
management of multiple applications
sites and racks

Rack LCD Console KVM Switches (8-


1U rackmountable integrated 16)
keyboard monitor mouse Manage multiple servers
with just one keyboard
monitor and mouse

Schneider Electric Critical Power & Cooling Services – Amod Ranade – August 18, 2008
Rack Power Distribution

Confidential Property of Schneider Electric | Page 42


Type Of Plug

IEC C13, C14 IEC C19, C20 Schuko / Euro Plug UK Plug

IEC 309/ Industrial Plug IEC 309/ Industrial Plug Terminal Block/ Terminal Block/
1Phase 3Phase Hardwire Hardwire
Confidential Property of Schneider Electric | Page 43
Rack Mount PDU
Power Distribution

• Rack mount PDU


• Metered
• Switched
• Metered By Outlet (MBO)
• Metered By Outlet with Switching
• Basic
• ATS for Single Corded Servers
that needs higher availability
(quick demo if needed)
• Up to 42 outlets x 2 = 84 outlets per rack
and with mounting possible on the same side of the Rack
• Metering of power consumption
within the rack allows planning for dual power supply
How to configure
Power Distribution

AP8853
Rack PDU 2G, Metered, ZeroU, 32A, 230V, (36) C13 & (6) C19

https://download.schneider-electric.com/files?
p_enDocType=Catalog&p_File_Name=998-
20849164_PDU+pocket+guide+FINAL.pdf&p_Doc_Ref=SPD_JKUR-8B2SG2_EN
https://www.apc.com/shop/id/en/tools/rack-
pdu-selector

https://www.apc.com/shop/id/en/
categories/power-distribution/N-9il763
Containment system

Confidential Property of Schneider Electric | Page 47


Schneider Value – We are more than just a manufacturer of components
End-to-end solutions and services to be the one-stop for a simple, fast, and predictable data center

EcoStruxure IT Expert with


Connected Components + Factory integration + On-site Services + options for remote
+ monitoring
& testing
and operation

Confidential Property of Schneider Electric | Page 48


RACS Flexibility


Modular System concept
Free to expand and grow
• Flexible to follow changing user
IT Usable Space – 38U needs.
• More Space to house
different type of IT
• Dedicated space for cable
routing & passthrough.
Inrow Cooling – 5kW
cooling
Redundancy • Intelegent CRAC.
• Flexible number of Cooling • Easy installation & service
and Power component • No need Outdoor Space
and piping

UPS 5 kVA – Power Input


• Rackmount UPS.
Environmental Monitoring • Easy installation & Service
• Temperature • Power back up for critical
• Relative Humidity components
• Smoke detection
• Door contact sensor

Battery Back up – 7.8 mins


(3kW load)
Monitoring • Provision to expand Battery
• Individual Display At UPS Backup till 4.5 hours
and Cooling
• Integrated Monitoring With
Data Center expert
software
Containment System
Ecoaisle Thermal Containment
• Ceiling panels support hot
or cold aisles

• Blank Panels
available for 300,
600, 700, and
750mm wide spaces

• Options available to support (900mm,


1200mm,1500mm, and 1800mm aisle widths ) • Safe Slide Doors support
• Panels Can also be modified in the field to fit hot or cold aisles
odd aisle sizes

Schneider Electric 50
Containment
Usage Flexibility
Introducing HyperPod
A rack-ready system designed to deploy IT at scale in increments of 8 to 12 racks

Benefits
1 Implement efficient data centers, while
maintaining flexibility and the ability to roll racks
in and out

Quickly install containment & infrastructure before


2 IT racks are delivered

Avoid costly, time consuming, and invasive


3
construction

Confidential Property of Schneider Electric | Page 52


Confidential Property of Schneider Electric | Page 53
Details of an All-In-One Data Center Module
ISO Containers have unique
Entrance Lobby/Electrical Room solutions to maximize space
• Isolated entrance room from IT space
constraints: Sliding track
• Main Input Electrical panels
system for racks and flexible
• Fire Suppression controls, alarm and tanks
cable trays allow racks to slide
(typically Novac 1230 system) forward and backward for easy
• Sub-system panels for cooling controls,
access and mounting of IT
emergency/security, house electrical (lighting equipment
and outlets)

Suspended Cable Trays & Fire Suppression

Hot/Cold Aisle Containment

Precision
UPS/Batt

Cooling
IT Racks

Items not clearly visible


• Cable trays suspended from ceiling
• Fire suppression piping
• Dehumidifier and optional humidifier
• Air recovery unit
• Monitoring/Management systems
• External condensers or chillers
BD01 – PFMICP027F1R005B

Easy UPS 3S EPDU1216M


Racks ER6202 (x5)
30kVA (N) / (2N) Metered (N) / (2N)

Container
Fire extinguishing
ISO20’ system Novec /
FM200
IT Load: 27kW
Uniflair Unisplit DX
(N+1)
5 Racks
Electrical Input (N) /
Rack density: (2N)
5,4kW

Confidential Property of Schneider Electric | Page 55


BD02 – PFMICP080F1R012B

Easy UPS 3M Racks ER6202 EPDU1232M


80kVA (N) / (2N) (x12) Metered (N) / (2N)

Container
ISO40’
Fire extinguishing
system Novec /
IT Load: 80kW FM200

Uniflair Unisplit DX
12 Racks (N+1)

Rack density: Electrical Input (N) /


6,7kW (2N)

Confidential Property of Schneider Electric | Page 56


Schneider Electric - Datacenter Solution
Enterprise Turnkey Solution
Network Connectivity
& Cable management
HV/MV & MV / LV
Transformers

MV and LV Switchboards Rack Systems


& Switchgears Power monitoring &
Energy Mgmt Software

Modular UPS Containment


System
Sensors&
Meters Precision cooling
InRow / Downflow
Busway

Software &
Analytics Chillers
Energy Automation

VSD Control

Modular UPS Lighting Access Control,


& PDU Control CCTV

Confidential Property of Schneider Electric | Page 57


95% of the Components in the Modules are Manufactured by Schneider

MV Switchgear

MV Switchboard

MV/LV Transformers
Access Control, CCTV
LV Switchboards
Busway
LV SwitchGear
Network connectivity
& Cable management

UPS Rack systems

Modular PDU Air Containment

Modular Row UPS

Lighting Control
Provides the best… Sensors & Meters
Room/Row/Rack
Design precision Cooling
Cooling VSD & Control
Service
Chillers
Performance
Indirect Free
Cooling