You are on page 1of 107

Thickness of

Wood
1CM
Chapel
Hospital
48
Filament
3110
Taal Lake
38.18
“A-B.”
0.42
“-10 , -15”
+5
Two pass tube
18,200
1513 tubes
Coefficient of
Vena
Contraction
0.69
Gearbox
1.2(Heat
Transfer)
58.8KW (Power)
Clever Brooks
52, 217:
892.12
Clever Brooks
52,000:
873 something
Blasius
0.114lbf
50 kgs air
emee, sagot -
0.58
Saddle:
353
2.04
0.04 (∆S)
Dancing
319
Largest Volume:
Crank End
Smallest Volume:
Head End
Paddle wheel
0.44
353
A boy pulls
20kg
6W
Designer
20
Ammonia
210
1200
11.88
Paddle wheel
0.44
353
Sink Temp –
6.22C
Fictitious:
Mean Effective
Pressure
Indicated
HP/ton
0.94 HP/TR
Black body
100
951
16
Creamery
20,000 liters
38.5 tor
40,000 liters
33
Thermoelectric

130
Pv^n=C If
n=0 "isobaric"
n=1 "isothermal"
Philippines
32m- 573
30- 504
A group of 30
person "33.1"
"Mass of
water"
111
Mindanao
AK-47
Astronaut
4810
a duct 0.40 m
high and 0.80
wide =
341 Pa
Not
combustible
"Oxygen"
Nuclear
MAY 7 SA
CHOICES
Not found in
flue gas
"Hydrogen"
Iligan NPC
545 ft., 93.16

500 ft., 85.47


Drag force
Sphere,
1.95
"Electrical
Energy, 45L"
4.36
Fluid
travelled
parallel
laminar
Flooded:
Float Valve
Debris:
Trash Rack
gearbox:
-1.2,
58.8
New Cummins:
36.08
Slab of Iron,
860 cal
Masonite
4750
"load factor" =
average load/peak
load
"Diversity factor" =
"Indiv
demand/overall
demand"
"Demand factor" =
Sum of
demand/connected
load
Four cycle
*2-stroke"
Buoyancy:
Archimedes Law
Ethane
96.96
Modern: Methane
R-1150: Ethene
Code 3542:
54.32
Phase out –
2030 AD
Determine the average velocity through a circular
section in
which the velocity distribution is given by 𝑣 = 𝑣𝑚𝑎𝑥
(1−(𝑟/𝑟𝑜)
2). The distribution is symmetric with respect to the
longitudinal
axis, r = 0, ro is the outer radius, vmax is the
velocity along the
longitudinal axis. Assume flow is laminar.

"Vmax/2"
Thrust: 36, 077
During an
experiment:
12302. 41
CHCLF2 –
R22
A suspension of a
finely divide fluid in
another- Emulsion
stratrosphere - CL
shits
R744 - carbon
dioxide
hotwire manometer-
gas velocities
"Boil Water hrs" –
0.6
75 MW: 21.15
85 MW: 29.15
95 MW: 41.15
Flat plate: 3.33
Self igniting
cartridges - 190
Temperature
required to ignite
fuel –
800 - 1000
Air pressure
required to produce
ignition temperature
350 -500
Blades - Runners
circular disk -25.
A liquid with a specific gravity of 1.26 is being
pumped in a pipeline from A to B. At A, the pipe
diameter is 60 cm and the pressure is 300 kN/m2 . At
B, the pipe diameter is 30 cm and the pressure is 330
kN/m2. Point B is 1.0 m lower than A. Find the flow
rate if the pump puts 16 kW into the flow. Neglect
head loss.

A and B: 0.42
VCR: 14.4
The sound power level Of a VAV Box (Variable Air
Volume) depends mainly on Volume flow of supply
air for a specific size box, configuration of
the VAV box, flexible ducts, diffusers and what
other factor?
A. Difference in static pressure across the VAV
in WC.
B. Configuration of the Damper actuator of the
VAV box.
C. Psychrometric properties of air entering the
VAV box.
D. Fan speed in RPM of the VAV fan.
Carnot cycle A, B
and C are connected
in series
A. 111.44 kW
An Otto cycle has a
clearance of 8% and heat
added of 1000 kJ. Find the
heat rejected.

B. 353
Water is being heated in a closed pan on
top of a range while being stirred by a
paddle wheel. During the process, 30 kJ of
heat is transferred to the water, and 5 kJ
of heat is lost to the surrounding air.
The paddle wheel work amounts to 500 N-m.
Determine the final energy of the system
if its initial energy is 10 kJ.

35.5
What should be the cooling requirement due to
emission of human body to maintain a comfortable
temperature in a dance hall with an attendance
of 1500 people of which 75% of the people will
be dancing and others will be seated? Take note
that an adult will give off 71.8 W of sensible
heat while engaging in moderate dancing, and
57.1 W of sensible heat while sitting. The
latent heat emissions for similar situations are
177.3 W for dancers and 45.5 W for sitters

319
In an ammonia condensing
machine (compressor plus
condenser) the water used for
condensing is 55°F and the
evaporator is at 15°F.
Calculate the ideal COP.

11.875
Compute the humidity ratio of air
at 70% relative humidity and 25°C
when the barometric pressure is
101.325 kPa.

A. 0.014 kgwater vapor/kgdry air


B. 1.4 kgwater vapor/kgdry air
C. 0.14 kgwater vapor/kgdry air
D. 0.0014 kgwater vapor/kgdry air
Determine the air-fuel ratio
on a molar basis for the
complete combustion of octane,
with theoretical amount of
air.
A. 95.5 kgair/kgfuel
B. 59.5 kgair/kgfuel
C. 59.9 kgair/kgfuel
D. 55.9 kgair/kgfuel
Critical temp of mercury

1460 C
critical pressure of
mercury
108 mpa
A 4 kg of air enters a turbine
with enthalpy of 600 kJ and
velocity of 250 m/s. The
enthalpy at exit is 486 kJ and
velocity of 170 m/s. What is
the work developed if there is
a heat loss of 10 kJ?
171.2
Type of coal formed
after anthracite –
Graphite
Contains 90% gasoline
and 10% ethanol
GASOHOL
Energy in transition -
Heat
7000ft - 447,000
8000ft - 512,000
Brown Coal - Lignite
Diesel ~ cetane
Gasoline ~ Octane
Piping, fittings and valve
materials found suitable for
use in Ammonia refrigerant
are manufactured from
Iron and steel
gas na hindi mag
mimix chemically -
Dalton's law of
partial pressure
Most common
secondary
refrigerant
BRINE
Bone tube with
narrow bone
CAPILLARY TUBE
Behave like
pure substance
AZEOTOPES
Freezing method

BLAST FREEZING
Shut off valve
SOLENOID VALVE
the velocity of
fluid is zero
VISCOUS EFFECT
Vent or hole in the
end surface
FUMAROLE
A water tube boiler has a capacity of 1000 kg/hr of
steam. The factor of evaporation is 1.3, boiler rating is
200%, boiler efficiency is 65% and heating surface area
is 0.91 m2 per bo.Hp. And the heating value of fuel is
18,400 kCal/kg. The total coal available in the bunker is
50,000 kg. Determine the no. of hrs. to consume the
available fuel.

853.36
A vapor compression refrigeration system is designed to have
a capacity of 150 tons of refrigeration. It produces chilled
water from 22°C to 2°C. Its actual coefficient of performance
is 5.86 and 35% of the power supplied to the compressor is
lost in the form of friction and cylinder cooling losses.
Determine the condenser cooling water required for a
temperature rise of 10°C.

14.75 KG/S

You might also like