ATTACHMENT- 1. FT4C-3 Twin Pac A.

. The liquid fueled, Model FT4C-3 Twin Pac, Electric Generating Plant consists of two FT4C-3 gas turbine drivers, one (1) generator with the following equipment: 1. Two (2) P&WA Model FT4C-3 gas turbine, S/Ns 686768, and 686744, each including an FT4C-3 free turbine S/Ns 600628 & 600574: a) Operating Controls b) Lubrication system c) Fuel control and fuel system d) Starter e) Ignition system f) Flexible coupling g) Mounts and base h) A CO2 fire protection system i) Dual Pall Trinity Filters 2. One (1) Synchronous generator (Mitsubishi S/N 2A1250Y0101), with the following accessories: a) One (1) Generator lubrication system consisting of an oil tank, an AC motor-driven oil pump, a DC motor-driven pump for emergency use, two oil pressure switches, and oil-to-air heat exchanger, and an oil level switch. b) Twelve (12) Resistance type temperature detectors for monitoring generator stator temperature. c) One (1) Set of high oil temperature alarm contacts for each bearing and for oil to bearings. d) One (1) Set of bearing oil thermometers on generator bearings. e) One (1) Set of high air temperature alarm contacts for generator. discharge air. f) Three (3) Current transformers. g) One (1) Generator grounding transformer and resistor. 3. One (1) Prefabricated 3-phase cable/duct bus assembly. To connect generator output terminals to generator circuit breaker. 4. One (1) 15kV metal-clad line-up containing the following: a) One (1) Generator air circuit breaker. b) Four (4) Potential transformers (PT) Draw-out type. c) Twelve (12) Current transformers (CT). d) Three (3) Surge capacitors (SC). e) Three (3) Lighting arresters (LA). f) One (1) set of space heaters.

5. One (1) turbine-generator control switchboard consisting of the following panels: a) Relay protection panel

b) c) d) e) f) g) h) i)

Auxiliary relay panel Metering and control Turbine instrument panel One (1) Station battery, 125 VDC. One (1) Master terminal board One (1) PLC based Control System Six (6) Lube oil pressure gages, located on engine base. One (1) Motor control center including the following: (1) One (1) Main circuit breaker. (2) Two (2) Free Turbine oil cooling fan motor starters. (3) Four (4) Engine oil cooling fan motor starters. (4) One (1) Generator AC oil pump motor starter. (5) One (1) Generator DC emergency pump motor starter. (6) One (1) Potential transformer. (7) One (1) Generator space heater contractor. (8) One (1) AC distribution panel board, multi-circuit. (9) One (1) DC distribution panel board, multi-circuit. (10) One (1) Generator space heater contractor. (11) One (1) Battery charge, static type.

2.

FT4C-3F/A-11 Power Pac A. The liquid fueled, Model FT4C-1/A-11 Power Pac Electric Generating Plant consists of one FT4A-11 gas turbine driver, one (1) generator with the following equipment:

1) One (1) P&WA Model FT4A-11 gas turbine S/N 685129, each including an FT4C3F Free Turbine S/N 600709: a) Operating Controls b) Lubrication system c) Fuel control and fuel system d) Starter e) Ignition system f) Flexible coupling g) Mounts and base h) A CO2 fire protection system i) Dual Pall Trinity Filters 2) One (1) Synchronous generator (EM Generator S/N 270144711), with the following accessories: a) One (1) Generator lubrication system consisting of an oil tank, an AC motor-driven oil pump, a DC motor-driven pump for emergency use, two oil pressure switches, and oil-to-air heat exchanger, and an oil level switch. b) Twelve (12) Resistance type temperature detectors for monitoring generator stator temperature. c) One (1) Set of high oil temperature alarm contacts for each bearing and for oil to bearings. d) One (1) Set of bearing oil thermometers on generator bearings. e) One (1) Set of high air temperature alarm contacts for generator. discharge air.

f) One (1) Set of leveling screws. g) Six (6) Current transformers. h) One (1) Generator grounding transformer and resistor. 3) One (1) Prefabricated 3-phase cable/duct bus assembly. To connect generator output terminals to generator circuit breaker. 4) One (1) 15kV metal-clad line-up containing the following: a) One (1) Generator air circuit breaker. b) Four (4) Potential transformers (PT) Draw-out type. c) Nine (9) Current transformers (CT). d) Three (3) Surge capacitors (SC). e) Three (3) Lighting arresters (LA). f) One (1) set of space heaters. 5) One (1) turbine-generator control switchboard consisting of the following panels: a) Relay protection panel b) Auxiliary relay panel c) Metering and control d) Turbine instrument panel e) One (1) Station battery, 125 VDC. f) One (1) Master terminal board g) One (1) PLC based Control System h) Six (6) Lube oil pressure gages, located on engine base. i) One (1) Motor control center including the following: (1) One (1) Main circuit breaker. (2) Two (2) Free Turbine oil cooling fan motor starters. (3) Four (4) Engine oil cooling fan motor starters. (4) One (1) Generator AC oil pump motor starter. (5) One (1) Generator DC emergency pump motor starter. (6) One (1) Potential transformer. (7) One (1) Generator space heater contractor. (8) One (1) AC distribution panel board, multi-circuit. (9) One (1) DC distribution panel board, multi-circuit. (10) One (1) Generator space heater contractor. (11) One (1) Battery charge, static type. B. 3. One (1) gas turbine inlet air filter.

FT4A-11/9 Mobile Pac A. The liquid fueled, Model FT4A-11/A-9 Mobile Pac Electric Generating Plant consists of one FT4A-9 gas turbine, one (1) generator with the following equipment: 1. One (1) P&WA Model FT4A-9 gas turbine S/N 672418, each including an FT4A-11 Free Turbine S/N 600450): a) Operating Controls b) Lubrication system c) Fuel control and fuel system d) Starter e) Ignition system

f) g) h) i)

Flexible coupling Mounts and base A CO2 fire protection system Dual Pall Trinity Filters

2. One (1) Synchronous generator (EM Generator S/N 272214101), with the following accessories: a) One (1) Generator lubrication system consisting of an oil tank, an AC motor-driven oil pump, a DC motor-driven pump for emergency use, two oil pressure switches, and oil-to-air heat exchanger, and an oil level switch. b) Twelve (12) Resistance type temperature detectors for monitoring generator stator temperature. c) One (1) Set of high oil temperature alarm contacts for each bearing and for oil to bearings. d) One (1) Set of bearing oil thermometers on generator bearings. e) One (1) Set of high air temperature alarm contacts for generator. discharge air. f) Three (3) Current transformers. g) One (1) Generator grounding transformer and resistor. 3. One (1) Prefabricated 3-phase bus duct assembly. To connect generator output terminals to generator circuit breaker. 4. One (1) 15kV metal-clad line-up containing the following: a) One (1) Generator air circuit breaker. b) Four (4) Potential transformers (PT) Draw-out type. c) Twelve (12) Current transformers (CT). d) Three (3) Surge capacitors (SC). e) Three (3) Lighting arresters (LA). f) One (1) set of space heaters. 5. One (1) turbine-generator control switchboard consisting of the following panels: a) Relay protection panel b) Auxiliary relay panel c) Metering and control d) Turbine instrument panel e) One (1) Station battery, 125 VDC. (shared with Power Pac) f) One (1) Master terminal board g) One (1) PLC based Control System h) Six (6) Lube oil pressure gages, located on engine base. i) One (1) Motor control center including the following: (1) One (1) Main circuit breaker. (2) Two (2) Free Turbine oil cooling fan motor starters. (3) Four (4) Engine oil cooling fan motor starters. (4) One (1) Generator AC oil pump motor starter. (5) One (1) Generator DC emergency pump motor starter. (6) One (1) Potential transformer. (7) One (1) Generator space heater contractor. (8) One (1) AC distribution panel board, multi-circuit. (9) One (1) DC distribution panel board, multi-circuit.

(10) One (1) Generator space heater contractor. (11) One (1) Battery charge, static type. 4. Barge: One 300 feet by 90 feet by 20 feet deep steel hull barge with platform for three gas turbine power plants. Switchyard A. B. C. D. E. F. G. H. I. J. K. L. M. 5. (4) Main Power Transformers (13.8kV to 69kV) (1) Oil Circuit Breaker Dead End Structure Lighting Arrestors Suspension Insulators Post Insulators Potential Transformers Open Delta Current Transformers located in OCB & Main Power Xfmr (3 each, 1 per phase) Disconnect switches Non segregated buss duct or cable Switchgear to MPT Air Insulated Cable 1200 MCM w/compression terminal lugs NEMA 2 hole, includes wire for interconnect, but not for transmission line Fire Suppression System Fire walls separating each transformer

5.

Balance of Plant A. B. C. D. E. Balance of plant control room (Switchyard monitoring & relays, BOP MCCs, locker room, bathroom) Fuel treatment system (Westfalia centrifuge system: 4 centrifuges to supply 133% of plant need) Treated fuel storage tank (Onboard storage of 12 hours of fuel at base load) Oily water separation system and storage (located below deck) Plant lighting, barge obstruction lighting, fog horn, life boars, life vests