Professional Documents
Culture Documents
Digital Multimeter KM 859cf
Digital Multimeter KM 859cf
SUR
Digital Multimeter best in india Kusam Meco kusum meco railways multimeters indian mutimeter KM multimeters instruments meter kolkata calcutta Indian multimeter 859CF 6 digit multimeter measure at par fluke cat iv multimeter
A1
ELECTRICAL SPECIFICATIONS
ACCURACY IS (%Reading digits + number of digits) or otherwise specified, at 23C 5C & less than 75% relative humidity. True RMS voltage & current accuracies are specified from 5 % to 100% of range or otherwise specified, Maximum Crest Factor < 5:1 at full scale & <10:1 at half scale, and with frequency component within the specified frequency bandwidth for non-sinusoidal waveforms.
DC VOLTAGE
Range KM 857 KM859CF Accuracy
CAPACITANCE
Range Accuracy *
50.00nF 500.0nF 5.000mF 50.00mF 500.0mF 9999mF 0.8% +3d 0.8% +3d 1.0% +3d 2.0% + 3d 3.5% + 5d 5.0% +5d
AC & AC + DC VOLTAGE
Range KM857 Accuracy* 20Hz -- 45Hz KM859CF
1.5% rdg + 40 dgts Unspecd Unspecd
500.00mV,5.0000V, 0.02% rdg + 2 dgts 0.03% rdg + 2 dgts 50.000V 0.04% rdg + 2 dgts 0.05% rdg + 2 dgts 500.00V 0.05% rdg + 2 dgts 0.1% rdg + 2 dgts 1000.0V
NMRR : > 60dB @ 50/60Hz CMRR : > 120dB @ DC, 50/60Hz, Rs = 1kW Input Impedance : 10MW, 30pF nominal (80pF nominal for 500mV ranges)
500.00mV, 5.0000V, 50.000V 500.00V, 1000.0V 500.00mV, 5.0000V, 50.000V 500.00V, 1000.0V 500.00mV, 5.0000V, 50.000V 500.00V 1000.0V
45Hz -- 300Hz
0.3% rdg + 20 dgts 0.8% rdg + 20 dgts 0.4% rdg + 40 dgts 0.8% rdg + 60 dgts
%DIODE TESTER
Range 5.0000V Accuracy 1 %+1d Test Current Open Circuit (Typical) Voltage 0.8mA < 3.5 VDC
300Hz -- 5kHz
0.3% rdg + 10 dgts 0.4% rdg + 40 dgts 0.8% rdg + 40 dgts (300Hz--1kHz)
300Hz -- 1kHz
0.8% rdg + 40 dgts 2.0% rdg + 60 dgts 1.0% rdg + 40 dgts
dBm : At 600W, -11.76dBm to 54.25dBm, Accuracy : 0.25dB + 2d (@40Hz -- 20kHz) Input Impedance : 10MW, 30pF nominal Selectable reference impedance values of 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, 1200W Crest mode (Instantaneous Peak Hold) : Accuracy : Specified accuracy 100 digits for changes > 0.8ms in duration
OHMS
Range
500.00 W 5.0000 kW 50.000 kW 500.00 kW 5.0000 MW 50.000 MW
5kHz -- 20kHz
KM859CF KM857 Accuracy
0.07% + 10d 0.07% +2d 0.2% +6d 2.0% +6d 0.1%+6d 0.4% +6d 2.0% +6d
1kHz -- 20kHz
1dB* * 2dB* * 3dB* * Unspecd
0.5% rdg + 20 dgts 0.8% rdg + 20 dgts 0.5% rdg + 20 dgts Unspecd
20kHz -- 100kHz
500.00mV, 5.0000V, 50.000V 500.00V 1000.0V Unspecd *From 5% to 10% of range : accuracy % of reading (or in dB) + 80d * *From 5% to 10% of range : accuracy % of reading (or in dB) + 180d * * From 10% to 15% of range : accuracy % of reading (or in dB) + 100d CMRR : > 90dB @ DC to 60Hz, Rs = 1kW Input Impedance : 10MW, 30pF nominal (80pF nominal for 500mV range) Residual reading less than 50 digits with test leads shorted. 2.0% rdg + 40 dgts 4.0% rdg + 40 dgts* * Unspecd
AC & AC + DC CURRENT
Range KM859CF KM857
Burden Voltage
Accuracy
0.3% + 1C 0.3% + 2F
40Hz -- 1kHz
500.00mA 5000.0mA 50.000mA 500.00mA 5.0000A 10.000A*
DC CURRENT
Range
500.00mA 5000.0mA 50.000mA 500.00mA 5.0000A 10.000A*
Accuracy
0.15% rdg + 20 dgts 0.1% rdg + 20 dgts 0.15% rdg + 10dgts 0.1% rdg + 20 dgts 0.5% rdg + 10 dgts 0.5% rdg + 20 dgts
Burden Voltage
0.15mV/mA 0.15mV/mA 3.3mV/mA 3.3mV/mA 0.03V/A 0.03V/A
1kHz -- 10kHz
500.00mA 5000.0mA 50.000mA 500.00mA 5.0000A 10.000A*
Unspecd
Unspecd
* 10A continuous, 20A for 30 second max with 5 minutes cool down interval
*10A continuous, 20A for 30 second max with 5 minutes cool down interval
Accuracy
3d/kHz+2d
Office : 54. Ezra Street, Kolkata - 700 001, India. Tel. : (033) 3291 6080, 22356676 Fax : (033) 3022 2923 E-mail : info@industrialindia.com, Website : www.industrialindia.com A1