Design calculation of weld thickness for Bracing connection

Project : Meja Thermal Power Project (2x660MW)


Client : National Thermal Power Project
Sub Consultant : Engineering Consultancy Services
Document No. : 0360-315A-PVC-U-006-SH-01 (R-1)
S. MEMBER
No.

ISMC 150
(BOX)
2
ISMC 200
(BOX)
3
ISMC 250
(BOX)
4
ISMC 300
(BOX)
6
ISMC 400
(BOX)
7 ISMC400+
plt. 300x10
(BOX)
8
BOX
400x250x20
x20
9
BOX
400x250x16
x16
10
BOX
400x250x12
x12

AREA OF
SINGLE
MEMBER
(CM2)

LOAD
WELD
TOTAL
TOTAL PROVIDED
CARRY
SIZE
WELD
WELD
WELD
CAPACIT (MM)
LENGTH
LENGTH LENGTH
Y OF
REQD. FOR
REQD.
FOR BOX
SINGLE
SINGLE
FOR
SECTION /
MEMBER
MEMBER OR DOUBLE SINGLE
(kN)
HALF BOX MEMBER MEMBER
(MM)
(MM)
(MM)

21.3

319.5

855.89

1711.78

1750.00

28.5

427.5

858.90

1717.81

1750.00

39

585

10

940.27

1880.55

1900.00

46.3

694.5

10

1116.27

2232.54

2250.00

63.8

957

12

1281.82

2563.65

2600.00

93.8

1407

12

1884.56

3769.13

3800.00

122

1830

16

1838.35

3676.71

3700.00

98.88

1483.2

16

1489.97

2979.94

3000.00

75.12

1126.8

14

1293.65

2587.30

2600.00

You might also like