You are on page 1of 3

3.

6 POWER CONSUMED BY EXISTING ESP UNIT


There are 4 paths (A & B) and 7 fields in each path. 1electronic controller for each field, 28
electronic controllers are installed for each unit.

Power consumption by field A

Voltage (KV)

A1

A2

A3

A4

A5

A6

A7

37

51

47

45

53

52

47

200

120

100

210

250

210

100

7400

6120

4700

9450

13250

10920

4700

V
Current (mA)
I
Power (watt)
V*I

Total Power consumed by field A:


=7400+6120+4700+9450+13250+10920+4700
=56540 watt

Power consumption by field B

Voltage (KV)

B1

B2

B3

B4

B5

B6

B7

45

39

45

43

40

36

21

240

160

120

140

160

210

220

10800

6240

5400

6020

6400

7560

4620

V
Current (mA)
I
Power (watt)
V*I

Total Power consumed by field B:


10800+6240+5400+6020+6400+7560+4620=
=47040

Power consumption by field C

Voltage (KV)

C1

C2

C3

C4

C5

C6

C7

31

42

70

55

44

47

48

200

120

130

110

110

130

120

6200

5040

9100

6050

4840

6110

5707

V
Current (mA)
I
Power (watt)
V*I

Total Power consumed by field A:


=6200+5040+9100+6050+4840+6110+5707
=43100 watt

Power consumption by field D

Voltage (KV)

D1

D2

D3

D4

D5

D6

D7

40

41

34

24

48

41

79

220

180

190

140

110

160

110

8800

7380

6460

3360

5280

6560

8690

V
Current (mA)
I
Power (watt)
V*I

Total Power consumed by field A:


=8800+7380+6460+3360+5280+6560+8690
=46530 watt

Total power consumed by 4 fields

=56540+47040+43100+46530
=193210watt
=193KW