Beam-column example 1 Rolled Universal Column Problem


Select a suitable UKC in S275 steel to carry safely a combination of 840kN in direct compression and a uniform bending moment about the minor axis of 12 kNm, over an unsupported height of 3.6 m.

_I
W

Try 2 0 . 7 x20.3 x 60 UKC in S275 steel member capacity tables suggest a minor axis buckling resistance Nh,i,Hd of approximately 1400 kN will provide correct sort o,f margin to carry the moment.
~

Steel Building Design: Design Data

Partial factors:
7/uo = 1.0; 7/Ul = 1.0

U K N A to BS EN 1993-1-1

Geometric properties:
h b = 205.8mm; c , / t , =17.1; i, = 8.96 cm = 89.6mm; iz = 5.20 cm WIJl,, = 656 cm' = 656 x 10' mm ' ;
cl /ti = 6.20;
= 209.6mm;

t , = 9.4mm; ti =14.2mm; A = 76.4 cm2 = 7640mm2; = 52.0mm; WIJl,? = 305 cm' = 305 x l O'mm ' ;

Steel Building Design: Design Data

Material properties. Yield strength f ,


= 275 N/mmz since

ti < 16mm

B S EN 10025-2

Check cross-section classijkation: For a Class I outstand flange in compression ct /tie 5 9 BS EN 1993-1-1 Table 5.2