You are on page 1of 1

EG 15-5-1.

1 LEVEL INSTRUMENTS, GAUGE GLASS COLUMNS


Page 1 of 1 Rev. 0 April, 1995

SCOPE
I

1.1

This guide lists the pressure/temperature ratings for level gauge as specified in paragraph 8.8 of RP 15-5-1. DESIGN

2.1

For general service, gauge glass columns shall be specified suitable for pressure/temperature ratings found in Table 1. The column type and pressure/temperature rating shall be specified on installation drawings. TABLE 1 GAUGE GLASS COLUMN PRESSURE/TEMPERATURE RATINGS
DESIGN TEMPERATURE, _F THRU-VISION PRESSURE RATING, PSIG (NOTE 1) 100 200 300 400 500 600 1,000 950 900 800 750 650 (NOTE 2) 2,000 1,900 1,750 1,650 1,450 1,300 REFLEX-TYPE PRESSURE RATING, PSIG (NOTE 3) 2,000 1,900 1,750 1,650 1,450 1,300 (NOTE 4) 3,000 2,800 2,650 2,450 2,250 2,000

Notes: (1) Brand equals are Daniel 9_TMWA, Jerguson_9TC20, Penberthy_TM9, and Strahman SVT_4. (2) Brand equals are Daniel 9_THWA, Jerguson_9TC30, Penberthy_YH9, and Strahman SVT_6. (3) Brand equals are Daniel 9_RMWA, Jerguson_9RC20, Penberthy_RM9, and Strahman SVR_3. (4) Brand equals are Daniel 9_RHWA, Jerguson_9RC30, Penberthy_RH9, and Strahman SVR_5. (5) The blank space in each model number shall be filled in with the number of gauge glass sections required; e.g., (SVT24) from one through five sections. Five sections are the maximum permitted from one set of process connections.

(6)

Gauges for pressures and temperatures higher than noted above shall be considered special, and Owners Engineer shall be consulted.

Revision Memo 4/95 Rev. 0 Original Issue

E Exxon Company, U.S.A., Exxon Chemical Americas, 1995

EXXON REGIONAL ENGINEERING GUIDE