You are on page 1of 1

SEAL OF APPROVAL

FLOOR WISE FSI STATEMENT: A (HOME) FLOORS BUILDING WISE FSI STATEMENT BUILDING
A-1 (HOME) Total PARAPETWALLOUTLINE

COMM.
0.00 0.00 0.00 0.00 0.00

FSI AREA RESI. IND.


0.00 64.56 64.56 64.56 193.69 0.00 0.00 0.00 0.00 0.00

SPEC.
0.00 0.00 0.00 0.00 0.00

BALCONY PASSAGE
0.00 9.68 9.68 0.00 19.37 0.00 0.00 0.00 0.00 0.00

STAIR
0.00 7.40 7.40 7.40 22.20

LIFT
0.00 0.00 0.00 0.00 0.00

TENEMENTS
0 0 0 1 1

TOTAL FSI AREA


0.00 64.56 64.56 64.56 193.69

COMM.
0.00 0.00

FSI AREA RESI. IND.


193.69 193.69 0.00 0.00

SPEC.
0.00 0.00

BALCONY PASSAGE
19.37 19.37 0.00 0.00

STAIR
22.20 22.20

LIFT
0.00 0.00

TENEMENTS
1 1

TOTAL FSI AREA


193.69 193.69

SECOND FLOOR FIRST FLOOR GROUND FLOOR Total

AREA STATEMENT 1. AREA OF PLOT 2. DEDUTIONS (From Gross Plot Area) (a) ROAD SETBACK AREA (RW) (b) OTHERS Total (a+b) 3. BALANCE PLOT AREA 4. PERMISSIBLE F A R FACTOR PERMISSIBLE BUILT UP AREA 5. SPECIAL CASES F A R 6. TOTAL PERMISSIBLE BUILT UP AREA 7. PROPOSED AREAS (a) PROPOSED RESIDENTIAL AREA (b) PROPOSED COMMERCIAL AREA (c) PROPOSED INDUSTRIAL AREA (d) PROPOSED SPECIAL USE AREA TOTAL PROPOSED AREA (a+b+c+d) 8. EXCESS SERVICE AREA 9. EXISTING BUILT UP AREA 10. OTHERS (SUBSTRUCTURE/PROJECTIONS) 11. TOTAL BUILT UP AREA PROPOSED (7 to10) 12. CONSUMED FAR 13. TOTAL SLAB AREA 14. COVERAGE AREA PERMISSIBLE SPECIFICATIONS
10.74 10.74 10.74

SQ.M.

139.29 0.00 0.00 0.00 139.29 Not Allowed 0.00 0.00 0.00 193.69 0.00 0.00 0.00 193.69 0.00 0.00 0.00 193.69 1.3905 235.24 64.56 (46.35%)
PROPOSED

PARAPETWALLOUTLINE

SECOND FLOOR

PARAPET WALL .10 RCC SLAB


3.05

3.05

1.05

PARAPET WALL

GROUND FLOOR PLAN


6.70

9.91

NA

.10 RCC SLAB


3.05

.10 RCC SLAB COMPOUND WALL

2.15

FIRST FLOOR

S1 A-Block 3.44

PLINTH FRONT ELEVATION BACK ELEVATION SECTION A-A

GL

PLINTH

0.76

GROUND FLOOR

CERTIFICATE OF AREA PLINTH SECTION B-B Polygon A-Block S1 Total


6.70 6.70

Area 71.96 7.40 64.56

CERTIFIED THAT I HAVE SURVEYED THE PLOT UNDER REFERENCE ON _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ AND THAT THE DIMENTIONS OF THE SIDES, ETC. OF THE PLOT STATED ON THE PLAN ARE AS MEASURED ON THE SITE AND THE AREA SO WORKED OUT IS _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ SQUARE METRES AND TALLIES WITH THE AREA STATED IN THE DOCUMENT OF OWNERSHIP / TOWN PLANNING SCHEME RECORDS.

1.50

COVERED GARAGE

1.50

TYPICAL - 1& 2 FLOOR PLAN


6.70

SIGN OF ARCHITECT/ENGINEER/SUPERVISOR LEGEND PLOT BOUNDARY SHOWN THICK BLACK PROPOSED WORK SHOWN RED FILLED IN DRAINAGE LINE SHOWN RED DOTTED

2.44 5.00

2.15

150 MM C/C 6 MM
10.74 10.74

4 NO. 12 MM

10.74

S1 A-Block 3.44

WATERLINE SHOWN BLUE DOTTED EXISTING TO BE RETAINED HATCHED DEMOLISHION SHOWN HATCHED YELLOW PROJECT INFORMATION

2.44

MAIN PLOT
10.74

V1

V1

6.70

D1

W1

0.90

V1 TOILET 1.96x1.53 TOILET 1.96x1.53 D2 D1

6.70

W1

0.90

6.65

FOUNDATION
6.70

PLOT NO: ZONE : INDORE. (M.P.) Area 71.96 7.40 64.56 OWNER'S NAME AND SIGNATURE

WARD

A-1 (HOME) Building Height : 9.91 Mtrs No of Floors... BAL ABOVE

TOILET 1.26x2.13 STORE 1.50x3.16 D2 D2 1.26x1.03 D1


2.15

15.24(P)

V1 KITCHEN 3.54x3.16
3.55

COLONY:

3.55

D2

BED ROOM 4.44x3.16

6.70

V1

Polygon
SITE PLAN 1:300
2.15

P NO

P NO

A-Block S1 Total

W1
10.74 10.74

TERRACE

BALCONY 0.90x5.56

5.56

5.56

BAL ABOVE BAL ABOVE


3.00 6.70

D1 D1 D1

D1 D1 D1

OPEN

2.44

DINNING 6.50x3.47 SPLIT 101

STAIRCASE
10.74 10.74 3.44

W1

10.74

3.44

3.44

10.74

LIVING 6.50x3.47

STAIRCASE

2.15

STAIRCASE

OPEN

SPLIT 101

P NO.

OWNER P NO

BUILDER'S INFORMATION
P NO NO.

NAME : LICENSE NO: B.O. NAME : B. I. NAME : PREVIOUS SANCTION MEMO NO:

SITE PLAN W1 BED ROOM 3.23x3.71 FAMILY RM 3.17x3.71


2.53

W1

BED ROOM 3.23x3.71

FAMILY RM 3.17x3.71
2.53

OPEN

ARCHITECT NAME

9.14(P)

30.00 M WIDE ROAD D1 D1 BAL ABOVE


6.70 6.70

NORTH

0.90

0.90

30.00 M. WIDE ROAD

W1

W1
0.90

D1 W1 BALCONY 5.20x0.90
5.20 6.70

D1

W1
1.50

JOB NO.

DRG.NO.

SCALE 1:100

DRAWN BY CHECKED BY

LAYOUT PLAN ISO_A1_(841.00_x_594.00_MM)

GROUND FLOOR PLAN

0.90

TYPICAL - 1& 2 FLOOR PLAN

PARAPETWALLOUTLINE

5.15

1.50

INWARD NO INWD KEY NO 396

DATE

31-10-2012

SHEET NO 1 / 1

This is a system generated and scrutinized drawing as per the soft copy submitted by the Architect/ Engineer/ supervisor.

You might also like