You are on page 1of 1

1

8
CONTRACT / PURCHASE ORDER
NUMBER

FI
001

001

From:LP-steam distribution pipe

400-S(5.0)-369-002

21.0 t/h/171.0 C

A1-2629 M-369-06-0033

FW tank heating steam

52.0 t/h/171.0 C

TI

369-FI-002
369-FIT-002

TIT

002

007

FIT

TE

002

200-V3242
369-004

M
200-WTDM-369-003
200-V1245
369-002

65-VEN-369-001

369-ZSC-003
369-ZSC-003
369-ZSO-003
369-ZSO-003

ZSC

ZSC

003

003

HS
003
ZSO

ZSO

003

003

369-HS-003
369-HV-003

189.0 t/h/95.0 C

PIC
400

80-V3236
369-881

350

N10

N9

150

N8

65

150-V3236
369-027

N7

N11

N12

N13

3.3 m x 19.8 m
101.2 m
22 min
159 C / 5 bar(g)

N23A

N23B

N21

TE
005

TI

TIT

N20

N22

N16

RESERVE

1003

A1-2629 M-369-06-0035

Amine from pumps

15

From:Feedwater pump 2

50-WDH-369-036

FW pump 2 balance flow

A1-2629 M-369-06-0003
From:Feedwater pump 1

50-WDH-369-035

FW pump 1 balance flow

A1-2629 M-369-06-0003

ISSUED

DATE

APP`D

ISSUED FOR

APP`D

ISSUED FOR

REV.

REV.

ISSUED

ISSUED

DATE

DATE

APP`D

APP`D

ISSUED FOR

ISSUED FOR

REV.

REV.

ISSUED

ISSUED

DATE

DATE

1/3/2011

APP`D

APP`D

ARN

ISSUED FOR

ISSUED FOR

OPERATION MANUAL
FINAL ISSUE

REV.

REV. 6

ISSUED

DATE

APP`D

27/10/10

ARN

ISSUED

DATE

APP`D

12/07/10

ARN

ISSUED FOR

REV. 5

OPERATION MANUAL
PRELIMINARY ISSUE
ISSUED FOR

CERTIFIED

15

CLIENT PROJ.MGR.

DRAW REV APR

CERTIFICATE FOR CONSTRUCTION

8-WD-369-009

To:Feedwater tank sample

Feedwater tank sample

A1-2629 M-369-06-0034

250-WD-369-007

To:Feedwater to pump 2

Feedwater to pump 2

A1-2629 M-369-06-0003

250-WD-369-006

To:Feedwater to pump 1

Feedwater to pump 1

A1-2629 M-369-06-0003

100-WD-369-005

To:Blowdown tank

Feedwater tank drain

A1-2629 M-369-06-0011

ISSUED

D
REV. 4

ISSUED

DATE

31/05/10
DATE

30/04/10

APP`D

ARN
APP`D

ARN

ISSUED FOR

REV. 3

REVIEW AND COMMENTS


ISSUED FOR

REV. 2

REVIEW AND COMMENTS

ISSUED

B
ISSUED

DATE

APP`D

23/02/10 ARN
DATE

APP`D

03/12/09 ARN

ISSUED FOR

PRELIMINARY

AREA NAME

369

BIOMASS BOILER No 2

TITLE

REV. 1

Biomass Boiler No 2
Process and Instrument Diagram
FEEDWATER DEAERATION
SCALE

S/E
REV. 0

PROJ.MGR.

C-626

REVIEW
ISSUED FOR

DEPT.MGR.

CELULOSA

CERTIFIED
DATE

DESCRIPTION

DATE

REV

AREA

ISSUED

EMISION N

ADDITIONAL
FW PUMP

15

6-TAM-369-005

N18 N25A N25A

From:Amine from pump 1

TI
005

N15B N15A

O2-scavenger from pumps

N17

15-V3222A
369-030

This document is the exclusive intellectual property of Metso Corporation and/or its subsidiaries and is furnished solely for operating and
maintaining the specific project. Re-use of the document for any other project or purpose is prohibited. The document or the information
shall not be reproduced, copied or disclosed to a third party without prior written consent of the company.

A1-2629 M-369-06-0035

369-TI-005
369-TIT-005
369-TE-005

INSTRUMENTO
LOCAL
369-PI-1002
369-TI-1003
369-LI-1001

MAN DOOR
N24B 20"

005

6-CHYD-369-005

N14B

369-22-001

004B

From:O2-scavenger from pump 1

N14A

VENDOR NUMBER

REV.

FI110108-00142
7

NAME
PROJ.
K. SILTA
DRAW. J. NISKAVAARA
REV.
K. SILTA
APR.
A. RANTEE

SIGN

DATE

KSI
JNIS

1.3.2011
1.3.2011

KSI
ARN

1.3.2011
1.3.2011

CMPC NUMBER

REV.

A1-2629 M-369-06-0002
8

$DATE$

25-V1556
369-007

N5C

DIGITAL INPUT
369-ZSO-003
369-ZSC-003
DIGITAL OUTPUT
369-HV-003

FEEDWATER TANK

50-V1556
369-017

50-V1236
369-009

N5B

RESERVE

FECHA EMISION

25-V2556A
369-013

N5A

25-V2556A
369-024

HORA

25-V2556A
369-011

N2B

25-V2556A
369-023

$TIME$

25-V2556A
369-022

A1-2629 M-369-06-0003

15-V1556
369-034

25-V2556A
369-015

N1

006C

A1-2629 M-369-06-0003
From:FW pump 1 min. flow

FW pump 1 min. flow

15-WD-369-008

004A

N2A

006B

ANALOGO INPUT
369-FIT-001
369-FIT-002
369-TIT-007
369-PIT-006A
369-PIT-006B
369-PIT-006C
369-LIT-004A
369-LIT-004B
369-LIT-004C
369-TIT-005
ANALOGO OUTPUT
369-LV-001
369-PV-002

From:FW pump 2 min. flow

80-WDH-369-008

FW pump 2 min. flow

100

50-V1556
369-016

006A

A1-2629 M-369-06-0011

150

25-V2556A
369-014

N19A
N4 N6
N3
369-LIC-004
369-LI-004A
369-LI-004B
LIT
LIT
369-LI-004C
MAN DOOR
369-LIT-004A
N24A 20"
369-LIT-004B
N19B
50-WD-369-002
369-LIT-004C
369-LV-004

PIT

To:Blowdown tank vent

FW tank SV blowout

80-WDH-369-007

100-V1236
369-029

25-V2556A
369-035

PIT

150-S(5.0)-369-002

004B

PIT

350-S(5.0)-369-002

004A

25369-036

H
H
L
L

HH
H
H
L

PI
006C

200-VEN-369-002

SRV
369-028
7.70 bar(g)

200

LIT
004C

LI

H
H
L
L

HH
H
H
L

PI
006B

150

25-V2556A
369-010

1001

LI

50-WD-369-002
25-V2556A
369-012

LI

CALC

HH
H
H
L

PI
006A

150-S(5.0)-369-002

004

50-V2556
369-879

25-V1556
369-006

004C

H
H
L
L 50-V1236
369-008

1002

25-VEN-369-001

PI

LIC
LI

50-VEN-369-001

2.60 t/h/160.0 C

CALC

25-V2556
369-021

CBD tank flash steam

25-V2556
369-018

150-S(5.0)-369-020

A1-2629 M-369-06-0011

25-VEN-369-001

From:Continuous blowdown tank

006

80-S(5.0)-369-002

0.90 t/h/160.0 C

150-V1236
369-026

50

65

FC

369-005

369-PV-006

208.0 t/h/110.0 C 200-V1245

15-V4454
369-033

Condensate return

15-V3222A
369-032

A1-2629 M-369-06-0013

369-PIC-006
369-PI-006A
369-PI-006B
369-PI-006C
369-PIT-006A
369-PIT-006B
369-PIT-006C
369-PV-006

40-V3222A
369-880

15-V4454
369-031

40-WCC-369-049

369-863

200-V1245
369-003

From:Condensate pump 1

Deaerator vent

369-864

FO
369-LV-004

400-V3236
369-025

200-V1245
369-001

Demiwater/Clean condensate to FW tank

369-001

DESCRIPTION

007

FC

REFERENCES / STANDARDS
NUMBER

369-HV-003

200-WTDM-096-0052

Demin. water & Clean condensate


A1-2629-365-06-001

369-TI-007
369-TIT-007
369-TE-007

007

FI

BIOMASS BOILER NO 2

369-FI-001
369-FIT-001

FIT

DESCRIPTION

C-626