You are on page 1of 1

QUALITY CONTROL

Howden UK

INSPECTION REPORT FAN CASING


CLIENT/SITE: NAME OF EQUIPMENT: PROJECT NUMBER:

PO 038669 Essar Steel (Minnesota) BREAKE PEDESTAL


DRAWING NUMBER:

H007780/02.076009 Rev.1

No.

Position Dwg.Dimension Actual Dimension

A 115 113 M 60 60 A 115 114 M 60 60

B 89 88 N 60 58 B 89 89 N 60 59

C 523 522 O 170 168 C 523 523 O 170 179

D 581 580 P 11 11 D 581 580 P 11 11

E 180 181 Q 11 11 E 180 180 Q 11 11

F 35 34

G 250 248

H 150 148

I 51 51

J 51 51

K 50 50

L 50 50

Remark

1 No.

Position Dwg.Dimension Actual Dimension Position Dwg.Dimension Actual Dimension

F 35 35

G 250 249

H 150 149

I 51 51

J 51 51

K 50 49

L 50 50

Position Dwg.Dimension Actual Dimension

*** REMARK: Tolerrence up to 2 m. 2 mm. APPROVED BY : WITNESSED DATE : ________ QC SUP/ENGINEER INSPECTED BY : QC INSPECTOR

DATE

RESULT

ACCEPTED UNACCEPTED