You are on page 1of 1

OPERATION AND OPTIMIZATION GUIDE

Fault: The cell only transmits traffic on handovers Investigation: After conventional operation investigation Sheet No.: O-20

Counters affected: Type 1 Traffic counters Ref. A B C Precaution: Counters C 1 NBR_DCCH_TERM_TRANS C 2 NBR_DCCH_ORIG_TRANS C 15 NBR_HO_RTCH_SEIZ Formulas / Thresholds Zero value Zero value Zero value

Check for system stability during the measurement period (alarm output). The counters are affected by the reloading of some SBLs.

Verification:

1 - Make sure the cell is not Barred 2 - Check Access control Class Barring flag

Actions :

Note:

These actions should be performed sequentially. Perform verification after each command. The last command may be used in emergencies.

1 - If cell Barred : debar Cell 2 - debar Access Control Class Otherwise execute following action, in sequence if previous action not succeeded : 3DISABLE - INIT BTS_TEL / RESET TCU supporting the BCCH (a spontaneous RESTART of the FU supporting the BCCH may occur) RESET FU supporting the BCCH RESET BTS

Date : 24/12/2013

Rfrence : 3DF 00963 2020 TQZZA

Version : 2.0

Page : 1 / 1