You are on page 1of 2

1 W HGR Hanger Design Load Case 2 W+T3+P1 HGR Hanger Design Load Case 3 WW+HP+H HYD Hydrotest 4 W+P1+H

SUS Sustained ( P1 = Design Presssure ) 5 W+T1+P1+H OPE Design Temp 6 W+T2+P1+H OPE Negative Design Temp/Minimum Ambient Temperature 7 W+T3+P1+H OPE Operating Temp 8 W+T3+P1+H+F1 OPE Operating + Slug Force 1 9 W+T3+P1+H+F2 OPE Operating + Slug Force 2 10 W+T3+P1+H+F3 OPE Operating + Slug Force 3 11 W+T3+P1+H+F4 OPE Operating + Slug Force 4 12 W+T3+P1+H+F5 OPE Operating + Slug Force 5 13 W+T3+P1+H+F6 OPE Operating + Slug Force 6 14 W+T3+P1+H+F7 OPE Operating + Slug Force 7 15 L8-L7 OCC Algebraic Slug Force 1 only 16 L9-L7 OCC Algebraic Slug Force 2 only 17 L10-L7 OCC Algebraic Slug Force 3 only 18 L11-L7 OCC Algebraic Slug Force 4 only 19 L12-L7 OCC Algebraic Slug Force 5 only 20 L13-L7 OCC Algebraic Slug Force 6 only 21 L14-L7 OCC Algebraic Slug Force 7 only 22 L15+L4 OCC Scalar Sustained + Slug Force 1 23 L16+L4 OCC Scalar Sustained + Slug Force 2 24 L17+L4 OCC Scalar Sustained + Slug Force 3 25 L18+L4 OCC Scalar Sustained + Slug Force 4 26 L19+L4 OCC Scalar Sustained + Slug Force 5 27 L20+L4 OCC Scalar Sustained + Slug Force 6 28 L21+L4 OCC Scalar Sustained + Slug Force 7 29 L5-L4 EXP Algebraic T1 30 L6-L4 EXP Algebraic T2 31 L7-L4 EXP Algebraic T3 32 L5-L6 EXP Algebraic T1-T2 (Maximum Stress Range) Please see my attachment. Since our slug force is over 15KN, case 22 to 28 have problem (over stresses).

Attachments

You might also like