You are on page 1of 10

Sheet 1 of 10 04-6224-3.

01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

Sheet 1 of 10 04-6224-3.01 Standard Alcatel-Lucent
Installation Guide Alcatel Lucent 9312 Compact Smart in 19 TIS ALU
W-CDMA
Alcatel-Lucent PROPRIETARY
This document contains proprietary information of Alcatel-Lucent and is not to be disclosed
or used except in accordance with applicable contracts or agreements
2009 Alcatel-Lucent All Rights Reserved
Design Control System
Used on
1. This is the preliminary issue
of 04-6241-2.01
2. This is the preliminary issue
of 04-6241-2.02 after
Internal review
3. Standard Version and 04-
6241 replaced by 04-6224-
301
20-08-09 03
APPD DRW Date
Issued
DRW
Issue
Installation Guide
Alcatel-Lucent 9312 Compact Smart in 19
Note: For site preparation requirements refer to:
IM 06-6228 Alcatel-Lucent 9312 Compact Smart NodeB Site Specification.
This document only covers W-CDMA modules/cables in the installed 19
Warning: In accordance with standard practice, cables must be installed so
that individual modules can be easily replaced without having to remove the cables.
C
!
Sheet 2 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

1. Hardware Installation
9326 d2U v2
NTYD0608
4 screws
3 screws on each side
4 screws
TRDU:
3JR21002AA
1U
A
B
C
Note: Perform the installation step in the correct order:
start with A, followed by B, and finally C
TRDU Subrack :
3JR08814AA
Sheet 3 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

TRDU3 Power in J 3 TRDU 3/6
TRDU2 Power in J 3 TRDU 2/5
TRDU1 Power in J 3 TRDU
TRDU TRDU ICO 1
3J R22039AA
TRDU6 Power in J 3 TRDU 3/6
TRDU5 Power in J 3 TRDU 2/5
TRDU4 Power in J 3 TRDU
TRDU TRDU ICO 2
3J R22039AA
2.RF and Power Cabling
Antenna
Torque wrench to 25 Nm
!
3
4
6
6
5
1
2
1 D2u GND NTU872GM 5
If two TRDU is used Up to 2 TRDU ICO power 3J R22057AA 4
2 meters or
3 meters
Up to 12 RF cable
TRDU to antenna
3BK05360CAAA or
3BK05360DAAA
6
3
2
1
TRCU power
TRDU power
d2U DC power
Remark Qty Ref
1 3J R22040AA
One per TRDU Up to 6 3J R22039AA
1 3J R08080AA
6
TRDU ICO
Breaker
Site
d2U
Breaker
Site
To GND Bar
Sheet 4 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

1AB382920001
TRDU 3 Data I/O Optic 3
TRDU 4 Data I/O Optic 4
TRDU 2 Data I/O Optic 2
TRDU 5 Data I/O Optic 5
TRDU 6 Data I/O
TRDU 1 Data I/O
Optic 6
Optic 1
1 RUC/xCCMu cable 3J R22028AC 9
1 PCM 100 Ohm T1 3J R30008AA
1 PCM cable 120 Ohm E1 NTU871MA 7
11
10
8
#
1 PCM adaptor 3J R22029AA
CPRI xCCM-U/TRDU cable
RUC/TRCU alarm cable
Designation
1 3J R22036AA
Up to 6 1AB382920001
Qty Ref
3.PCM and Digital Cabling
11
9
9 10
10
8
7
!
Warning
PCM DDF
Sheet 5 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

9
11
10
8
7
1 PCM 100 Ohm T1 3J R30008AA
1 RUC/TRCU alarm cable 3J R22036AA 10
1 RUC/xCCMu cable 3J R22028AC 9
1 PCM adaptor 3J R22029AA 8
1 PCM cable 120 Ohm E1 NTU871MA 7
1 GND M6 NTU872GP 12
1 TRCU Alarm out/d2U 3J R22038AA 11
2 Install Alarm 16 m NTBY6152 13
# Ref Qty Designation
13
12
4.Solution with Optional IEAM Module
PCM DDF Alarm DDF
To GND Bar
Sheet 6 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9
1 Inst PCM 120 Ohms NTBY60SF 15
1 Inst PCM 100 Ohms NTBY60TF
1 GND M6 NTU872GP 12
1 TRCU Alarm out/d2U 3J R22038AA 11
1 RUC/TRCU alarm cable 3J R22036AA 10
1 RUC/xCCMu cable 3J R22028AC 9
1 LPPCM OUT/XCCM IUB 3J R22030AA 14
Ref # Qty Designation
6.Solution with Optional LPPCM Module
9
11
10
14
15
12
PCM DDF
To GND Bar
Sheet 7 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

12
11
14
15
13
16
2 Install Alarm 16 m NTBY6152 13
1 Inst PCM 100 Ohms NTBY60TF
1 Inst PCM 120 Ohms NTBY60SF 15
1 LPPCM OUT/XCCM IUB 3J R22030AA 14
1 GND M6 NTU872GP 12
1 TRCU Alarm out/d2U 3J R22038AA 11
1 RUC/TRCU alarm cable 3J R22036AA 10
1 RUC/xCCMu cable 3J R22028AC 9
1 PCM/ALARM MOD CO NTA595QF 16
Ref # Qty Designation
10
9
7.Solution with optional IEAM+ LPPCM Module
PCM DDF
Alarm DDF
To GND Bar
Sheet 8 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

Up to 12 RF cable
TRDU to antenna
3BK05360CAAA or
3BK05360DAAA
6
Up to 2 TRDU ICO power 3J R22057AA 4
1 d2U DC power 3J R08080AA 1
2 Install Alarm 16 m NTBY6152 13
1 Inst PCM 100 Ohms NTBY60TF
1 Inst PCM 120 Ohms NTBY60SF 15
# Ref Qty Designation
15
8.Cabinet External Cabling Solution PCM 120 Ohms
1
13
4
DDF
Alarm
Tx/Rx
Customer
DC Box -48V
GND Site
Torque wrench to 25 Nm
!
17
Frame 19
17
GND Bar
Sheet 9 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

PCM Cable E1: NTBY60SF
The following pins: 19, 20, 29, 30 and 37 are not connected.
TX3- Red 36
TX3+
6
Blue 35
TX6- Red 34
TX6+
12
Blue 33
TX8- Red 32
TX8+
16
Blue 31
RX8- Red 28
RX8+
15
Blue 27
RX6- Red 26
RX6+
11
Blue 25
RX3- Red 24
RX3+
5
Blue 23
TX2- Red 22
TX2+
4
Blue 21
TX5- Red 18
TX5+
10
Blue 17
RX5- Red 16
RX5+
9
Blue 15
RX2- Red 14
RX2+
3
Blue 13
TX1- Red 12
TX1+
2
Blue 11
TX4- Red 10
TX4+
8
Blue 9
TX7- Red 8
TX7+
14
Blue 7
RX7- Red 6
RX7+
13
Blue 5
RX4- Red 4
RX4+
7
Blue 3
RX1- Red 2
RX1+
1
Blue 1
Signal Pair Conductor Color Pin
Note: If the color pairs are not as specified, the supplier must provide an
amendment to the above table, giving the actual cable colors used. This
information must be supplied on a notice delivered with each cable
9.Pin-Out 1/2
Alarm Cable: NTBY6152
Sheet 10 of 10 04-6224-3.01 Standard Alcatel-Lucent
Alcatel Lucent 9312 Compact Smart in MBI3+
SEE PROPRIETARY AND COPYRIGHT NOTICE ON COVER PAGE
N
a
m
e
:

C
h
r
i
s
t
i
a
n

M
o
r
e
a
u

O
b
j
e
c
t
:

I
G
-
0
4
-
6
2
2
4
-
3
.
0
1

D
a
t
e
:

A
u
g
u
s
t

2
0
,

2
0
0
9

PCM Cable T1: NTBY60TF
TX3- Green/White 36
TX3+
6
White/Green 35
TX6- Orange/Black 34
TX6+
12
Black/Orange 33
TX8- Violet/Black 32
TX8+
16
Black/Violet 31
RX8- Blue/Black 28
RX8+
15
Black/Blue 27
RX6- Red/Black 26
RX6+
11
Black/Red 25
RX3- Yellow/White 24
RX3+
5
White/Yellow 23
TX2- Orange/White 22
TX2+
4
White/Orange 21
TX5- Brown/Black 18
TX5+
10
Black/Brown 17
RX5- Gray/White 16
RX5+
9
White/Gray 15
RX2- Red/White 14
RX2+
3
White/Red 13
TX1- Brown/White 12
TX1+
2
White/Brown 11
TX4- Violet/White 10
TX4+
8
White/Violet 9
TX7- Green/Black 8
TX7+
14
Black/Green 7
RX7- Yellow/Black 6
RX7+
13
Black/Yellow 5
RX4- Blue/White 4
RX4+
7
White/Blue 3
RX1- Black/White 2
RX1+
1
White/Black 1
Signal Pair Conductor Color Pin
The following pins: 19, 20, 29, 30 and 37 are not connected.
9.Pin-Out 2/2
Note: If the color pairs are not as specified, the supplier must provide an
amendment to the above table, giving the actual cable colors used. This
information must be supplied on a notice delivered with each cable

You might also like