You are on page 1of 6

Project

Client Made by Date


RUJ UB 4-5-14
Checked Revision
- -
Design in accordance with BS 6399 : Part 2 : 1997
Ss Sp
Kb H (m) Cr
2 6 0.030 equ (C.2) 1.00 1.00
152
1.152 equ (9)
I II III IV
0 90 180 270
Direction factor Sd 1.000 1.000 1.000 1.000
Site Wind Speed (m/s) Vs 95.62 95.62 95.62 95.62 equ (8)
Average height (m) Ho 6 6 6 6
Upwind spacing (m) X 20 20 20 20
He 2.80 2.80 2.80 2.80
Distance to sea (km) 3 3 3 3
Terrain town town town town
Sb 1.29 1.29 1.29 1.29
Ve 123.16 123.16 123.16 123.16 equ (12)
qs 9298.7 9298.7 9298.7 9298.7 equ (1)
Cr okay - proceed with design
83
Wind Direction
Reference height
Hr (m) Vb (m/s)
6
Wind Loading Calculations
Camp LeVieux, Rose Hill J ob No
Universite des Mascareignes PFE - Structure Metallique
1
Page No
01 Wind Design Workbook 2000-2002 Chris Buczkowski Unregistered Copy for Evaluation
Dynamic Pressure (N/m)
Effective Height (m)
Description
Terrain and building factor
Effective Wind Speed (m/s)
Nearby
buildings
Site altitude,
S
(m)
Altitude factor, Sa
Dynamic Augmentation
Factor (Cr) Basic Wind Speed
Standard Wind Speeds
Standard values:
Ss=1.0 Sp=1.0
Altitude factor for non significant topography

N
I
II
III
IV
Wind directions
Building orientation unknown
Nearby buildings ignored
Project
Client Made by Date
RUJ UB 4-5-14
Checked Revision
- -
Design in accordance with BS 6399 : Part 2 : 1997
Ss Sp
Kb H (m) Cr
2 6 0.030 equ (C.2) 1.00 1.00
Z (m) 152
L
U
(m) 3003

U 0.051
e 0.051 X (m) LD X/LD H/Le s
L
e
(m) 3003 3000 2000 1.500 0.002 0.072
152
75
1.152 equ (10)
1.079 equ (11)
1.152
I II III IV
Wind direction 0 90 180 270
Direction factor Sd 0.865 0.765 0.965 1.000
Site Wind Speed (m/s) Vs 82.71 73.15 92.27 95.62 equ (8)
Average height (m) Ho 6 6 6 6
Upwind spacing (m) X 20 20 20 20
He 2.80 2.80 2.80 2.80
Distance to sea (km) 3 3 3 3
Terrain town town town town
Sb 1.29 1.29 1.29 1.29
Ve 106.54 94.22 118.85 123.16 equ (12)
qs 6957.5 5441.8 8659.1 9298.7 equ (1)
Wind Direction
Dynamic Augmentation
Factor (Cr) Basic Wind Speed Reference height
Feature Hill/ridge
Dynamic Pressure (N/m)
Nearby
buildings
Effective Height (m)
Terrain and building factor
Effective Wind Speed (m/s)
Altitude factor, Sa
Site location Downwind
Base altitude,

(m)
1 +0.001
S
1 +0.001

+1.2es
Upwind Slope
Parameters
Wind Design Workbook 2000-2002 Chris Buczkowski Unregistered Copy for Evaluation 02
1
Page No
Wind Loading Calculations
Camp LeVieux, Rose Hill
Universite des Mascareignes PFE - Structure Metallique
Description
J ob No
Site altitude,
S
(m)
Vb (m/s) Hr (m)
83 6
Cr okay - proceed with design
Topographic Location Factor, s
Non Significant !
Altitude factor for significant topography
Standard values:
Ss=1.0 Sp=1.0

N
I
II
III
IV
Standard Wind Speeds
Wind directions
Building orientation unknown
Nearby buildings ignored
Wind
Hr
X
Ho
Building under
consideration
Effective heights in towns
Project
Client Made by Date
RUJ UB 4-5-14
Checked Revision
- -
Design in accordance with BS 6399 : Part 2 : 1997
20 8 6
Kb H (m) Cr
2 6 0.030
equ (C.2)
Effective height, He (m)
Distance to sea (km)
fig 4
pe P pe P
N/m kN N/m kN
6588.45 790.61 5733.79 275.22
-2353.02 -282.36 -1285.16 -61.69
- 939.67 - 295.05 equ (7)
Note. -ve sign indicates suction.
equ (7a)
equ (7a)
Wind Design Workbook 2000-2002 Chris Buczkowski Unregistered Copy for Evaluation
A
21.541
Terrain
3 3
Site exposure type
16
Pf (kN/m height)
21.541
town town
6 6
Area, As (m/m width) 2 16
Is depth D>b/2 ? Yes Yes
Zone length D (m) 2
Pf (kN/m width) 0.676 5.410
Frictional drag coefficient, Cf 0.04 0.04
Ca
Diagonal dim. (m)
A
0.909 0.909
4.066
Frictional Drag on roof
Frictional drag coefficient, Cf 0.04 0.04
Ca 0.957 0.911
0.000
Zone length C (m) 0 12
Area, As (m/m height) 0 12
Frictional Drag on side walls
Is depth D>b ? No Yes
Overall horizontal loads
on building
Front face, P
front
Rear face, P
rear
Overall load, P
Diagonal dimension (m) 20.881 10.000
Ca 0.911 0.957
Site exposure type A A
0.778 0.644
Leeward (rear) face -0.278 -0.144
Windward (front) face
Scaling length, b 12 8
Span ratio, D/H 1.33
Size effect factor for external pressures, Ca
WIND NORMAL TO: LONG FACE SHORT FACE Building Dimensions
20
3.33
9298.7 9298.7 Width
W (m)
Height
H (m)
Inwind depth D (m) 8 20
Breadth B (m) 8
Length
L (m)
Description
1
Page No
External pressure coefficients Cpe for vertical walls
03
Dynamic Augmentation
Factor (Cr)
Dynamic Pressure, qs (N/m)
PFE - Structure Metallique
Wind Loading Calculations
Camp LeVieux, Rose Hill J ob No
Universite des Mascareignes
Standard Pressure Coefficients
Standard Wind Loads
Overall Building Loads
Project
Client Made by Date
RUJ UB 4-5-14
Checked Revision
- -
Design in accordance with BS 6399 : Part 2 : 1997
20 8 6
Wind on: Long Short
Side Face: (short wall) (long wall)
Exposure Zone A Zone A 2.4 1.6
Isolated Zone B Zone B 5.6 6.4
Isolated Zone C Zone C 0 12
Surface: External Internal External Internal Height Length
Effective height, He (m) h (m) l (m)
Distance to sea (km)
Site exposure type A A A A
5.000 95.828 5.000 95.828
Ca 1.000 0.816 1.000 0.816 880
Net Surface Pressures On External Walls
case (i) case (ii) case (i) case (ii) case (i) case (ii) case (i) case (ii) case (i) case (ii)
pe (N/m) 7232.3 - -2583.0 - -12088.3 - -7439.0 - - -
pi (N/m) -2276.5 - -2276.5 - -2276.5 - -2276.5 - - -
p (N/m) 9508.8 - -306.5 - -9811.8 - -5162.4 - - -
Note: -ve sign indicates suction or outward pressure, +ve sign indicates inward pressure
case (i) case (ii) case (i) case (ii) case (i) case (ii) case (i) case (ii) case (i) case (ii)
pe (N/m) 5992.5 - -1343.1 - -12088.3 - -7439.0 - -3719.5 -
pi (N/m) -2276.5 - -2276.5 - -2276.5 - -2276.5 - -2276.5 -
p (N/m) 8269.0 - 933.4 - -9811.8 - -5162.4 - -1443.0 -
Net Pressure On Internal Walls
Wind on: Long Short
Cp - -
p (N/m) - -
Dynamic Pressure, qs (N/m)
Inwind depth D (m) 8 20
Breadth B (m) 20 8
Enter storey volume
Description
Side Wall Zone Lengths (m)
town town
9298.7
-0.3
-0.3
-0.3
Wind On Long Face
Elevation:
Zone B Zone C
Windward (front) Leeward (rear)
Zone A
Sides
Internal Volume (m) Diagonal dimension (m)
Panel Dimensions
Terrain
6
3
Size effect factor, Ca
6
3
Both opposite walls:
-0.3
-0.3
Impermeable
Windward (front) face -0.3
Leeward (rear) face
Side Faces
-1.3
Side face
-1.3
-0.8 -0.8
-0.4
Universite des Mascareignes PFE - Structure Metallique
Wind Loading Calculations
J ob No Camp LeVieux, Rose Hill
1.33 3.33
2001
Page No
04
9298.7
Wind Design Workbook 2000-2002 Chris Buczkowski Unregistered Copy for Evaluation
Impermeable
Internal pressure coefficients Cpi for enclosed buildings
Span ratio, D/H
Scaling length, b
0.778 0.644
Leeward (rear) face -0.278 -0.144
Length
L (m)
External pressure coefficients Cpe for vertical walls
12
Windward (front) face
WIND NORMAL TO: LONG FACE SHORT FACE
8
Width
W (m)
Height
H (m)
Building Dimensions
Wind On Short Face
Elevation: Windward (front) Leeward (rear) Sides
Zone A Zone B Zone C
Vertical Walls of Rectangular Plan Buildings
Standard Pressure Coefficients
Internal layout generally open
Multi-room building
Standard Wind Loads
Project
Client Made by Date
RUJ UB 4-5-14
Checked Revision
- -
Design in accordance with BS 6399 : Part 2 : 1997
20 8 6
-1.35 -
-0.84 - Wind on: Long Short
-0.33 - Zone A 1.20 0.80
Zone B 1.20 0.80
Zone C 2.80 3.20
Zone D 16.00
Zone E 1.20
Zone F 1.20
Zone G 2.80
880
Surface: External Internal External Internal
Effective height, He (m)
Distance to sea (km)
Width Length
Site exposure type w (m) l (m)
21.541 95.828 21.541 95.828 8 20
Ca 0.909 0.816 0.909 0.816
Net Surface Pressures On Flat Roof
Zone E Zone F Zone G
case (i) case (ii) case (i) case (ii) case (i) case (ii)
pe (N/m) -11411.3 - -7100.4 - -2789.4 - -8790.9 -7100.4 -4057.4
pi (N/m) 1517.7 - 1517.7 - 1517.7 - 1517.7 1517.7 1517.7
p (N/m) -12929.0 - -8618.1 - -4307.1 - -10308.6 -8618.1 -5575.0
Note: -ve sign indicates suction or outward pressure, +ve sign indicates inward pressure
Zone A Zone B Zone C Zone D
pe (N/m) -13862.6 -12341.1 -5071.7 -2620.4
pi (N/m) -2276.5 -2276.5 -2276.5 -2276.5
p (N/m) -11586.1 -10064.6 -2795.2 -343.9
Wind On Short Face
Zone A Zone B Zone C
Wind On Long Face
Roof Dimensions
A A
Diagonal dimension (m)
3 3
Terrain town town
Internal Volume (m)
Enter storey volume
6 6
Roof 0.2 -0.3
Size effect factor, Ca
Permeability of the two walls
normal to wind
Equally permeable Impermeable
Internal pressure coefficients Cpi for enclosed buildings
Zone E
Zone F
Zone G -0.48
Zone C -0.60
Zone B -1.46
Zone D -0.31
Height
H (m)
Zone Lengths (m)
Breadth B (m) 20 8
Inwind depth D (m) 8
Zone A -1.64
External pressure coefficients Cpe for duopitch roofs
20 Building Dimensions
Scaling length, b 12
Dynamic Pressure, qs (N/m) 9298.7 9298.7
8 Length
L (m)
Width
W (m)
Universite des Mascareignes PFE - Structure Metallique Wind Loading Calculations
Camp LeVieux, Rose Hill
WIND NORMAL TO: LONG FACE SHORT FACE
Wind Design Workbook 2000-2002 Chris Buczkowski Unregistered Copy for Evaluation
14
1
Page No
07
Pitch angle
J ob No
Description
-1.04
-0.84
Wind on Duopitch Roofs
Standard Pressure Coefficients
Standard Wind Loads
Roof permeable