Professional Documents
Culture Documents
Practical CSWIP 3.1
Practical CSWIP 3.1
Date 16/07
TECHNOLOGY
Slag
Inclusion
L= 10,W=4
Cap Undercut
25 Intermittent
L= 15 ,D= 1.0 max
Cap Undercut
Intermittent
15 L= 30,D= 1.6
50
Cluster
Porosity
L=5 w = 3
100
Lack of
sidewall fusion
160
L= 10
Cap Undercut
Intermittent
L= 15 ,D= 1.0 max
10
Final Report
After you have completed your thumb print report sketch of
your test plate the next step is to complete your final report
again the report must be completed in ink (no pencil).
The report must be completed to your thumb print sketch,
do not leave any boxes empty, every box must be
completed or dashed out. You must also make any
comments you feel are necessary regarding any defects
observed.
The report form used in CSWIP will look like the following
example.
Reinforcement (Height)
Reinforcement (App)
Incomplete filling
Inadequate weld width
Slag inclusions
Undercut
Surface porosity
Cracks
Lack of fusion
Arc strikes
Mechanical damage
Laps/Laminations
Misalignment
Pipe/plate
Accumulative
Maximum
section no
Total
Table
A-C
L= 10 , D = 3.0
2.0
Accept/Reject
Rejected