You are on page 1of 1

3.

In Control
X
double
bar
Sx
z
zSx

4.02069
0.00518
3
0.01554
4

UCL
LCL

4.03623
4.00514

Pre Problem
X
double
bar
Sx
z
zSx
UCL
LCL

4.01880
0.00556
3
0.01668
4.03548
4.00212

Post Problem
X
double
bar
Sx
z
zSx
UCL
LCL

4.02236
0.00599
3
0.01797
4.04033
4.00439

a) It is reasonable to aim for an expected diameter size of 4.02 mm as it is


between UCL and LCL.
b) A few samples were not in the acceptable range between LCL and UCL.
c) No, the process is still not in control after adjustments, as the min and max
values have been swinging from 3.98846 and 4.06524.
d) Repair must be taken up and other solutions arent solving the problem.

You might also like