Professional Documents
Culture Documents
HILTI - Anchor Fastening Technology Manual
HILTI - Anchor Fastening Technology Manual
com
03.02.2009
11:22 Uhr
Hilti = registered trademark of Hilti Corp., Schaan | W 3638 0209 0-en | Printed in Germany | 2009 | Right of technical and programme changes reserved S. E. & O.
P14829_FTM_US.qxd
Seite 1
Anchor Fastening
Technology Manual
Foreword
Foreword
Dear customer,
As it is our ambition to be the worldwide leader in fastening technology we are
constantly striving to provide you with state-of-the-art technical information
reflecting the latest developments in regulations, codes and approvals.
This Fastening Technology Manual on the one side reflects our continuous
investment in long term basic research, regulation development as well as
approval implementation in various parts of the world and on the other side our
excellent understanding of the fastening needs of our customers. Profound
technical know-how paired with passion for quality will help you to be more
productive in your daily work without any compromise regarding reliability and
safety.
This Fastening Technology Manual will be a reliable support tool when solving
design and fastening tasks. You are working with a partner aware of the
demanding requirements of modern fastening technology.
As the fastening technology will further develop in future we would very much
appreciate your feedback. We are available at any time to answer additional
questions that even go beyond this content.
Rainer Httenberger
Senior Vice-President
Business Unit Anchor
1 / 2009
Important notice
Important notice
1. Construction materials and conditions vary on different sites. If it is suspected that the base
material has insufficient strength to achieve a suitable fastening, contact the Hilti Technical
Advisory Service.
2. The information and recommendations given herein are based on the principles, formulae
and safety factors set out in the Hilti technical instructions, the operating manuals, the setting
instructions, the installation manuals and other data sheets that are believed to be correct at
the time of writing. The data and values are based on the respective average values
obtained from tests under laboratory or other controlled conditions. It is the users
responsibility to use the data given in the light of conditions on site and taking into account
the intended use of the products concerned. The user has to check the listed prerequisites
and criteria conform with the conditions actually existing on the job-site. Whilst Hilti can give
general guidance and advice, the nature of Hilti products means that the ultimate
responsibility for selecting the right product for a particular application must lie with the
customer.
3. All products must be used, handled and applied strictly in accordance with all current
instructions for use published by Hilti, i.e. technical instructions, operating manuals, setting
instructions, installation manuals and others.
4. All products are supplied and advice is given subject to the Hilti terms of business.
5. Hiltis policy is one of continuous development. We therefore reserve the right to alter
specifications, etc. without notice.
6. The given mean ultimate loads and characteristic data in the Anchor Fastening Technology
Manual reflect actual test results and are thus valid only for the indicated test conditions.
Due to variations in local base materials, on-site testing is required to determine
performance at any specific site.
7. Hilti is not obligated for direct, indirect, incidental or consequential damages, losses or
expenses in connection with, or by reason of, the use of, or inability to use the products for
any purpose. Implied warranties of merchantability or fitness for a particular purpose are
specifally excluded.
Hilti Corporation
FL-9494 Schaan
Principality of Liechtenstein
www.hilti.com
1 / 2009
Contents
1 / 2009
Contents
Contents
Anchor technology and design ........................................................................... 7
Anchor selector...........................................................................................................................8
Legal environment ....................................................................................................................20
Approvals..................................................................................................................................22
Base material............................................................................................................................26
Anchor design...........................................................................................................................32
Design examples ......................................................................................................................48
Corrosion ..................................................................................................................................58
Dynamic....................................................................................................................................62
Resistance to fire ......................................................................................................................68
1 / 2009
Contents
1 / 2009
Anchor technology
and design
1 / 2009
Anchor technology
and design
1 / 2009
Anchor selector
Anchor selector
Base material
Application
Fire tested
Fastening heavy loads e.g. from
columns, high racks, machines
Approval
Aerated concrete
Lightweight concrete
Uncracked concrete
Cracked concrete
Anchor type
HDA-T/ -TR/TF/-P/-PR/-PF
undercut anchor
= very suitable
1) redundant fastening
1 / 2009
Anchor selector
Automatic undercutting
Small edge distances and
spacings
Small setting depth
Quick and simple setting
operation
Setting mark
Safety wedge for certain follow
up expansion
Two setting depths
Setting mark
Extremely ductile steel for high
bending capacity
Quick and simple setting
operation
1 / 2009
Through-fastening
80
96
108
132
144
156
160
Page
Pre-setting
Internal thread
Setting
External thread
Automatic undercutting
High load capacity
Approved for dynamic loads
Specification
Steel, sheradised, hot dipped galv.
Drill bit
diameter resp.
anchor size
Steel, galvanised
Advantages
166
Anchor selector
Application
1)
1)
Fire tested
Approval
Aerated concrete
Uncracked concrete
Lightweight concrete
Base material
Cracked concrete
Anchor type
Various applications
Various applications
= very suitable
10
1)
1) redundant fastening
1 / 2009
Anchor selector
Page
Through-fastening
Pre-setting
Internal thread
Setting
External thread
Specification
Steel, sheradised, hot dipped galv.
Drill bit
diameter resp.
anchor size
Steel, galvanised
Advantages
168
188
202
208
Fast setting
Flexibility of screw length
An anchor for every base
material
Fast setting
Flexibility of screw length
An anchor for every base
material
Flexibility of screw length
Resilient toggling action to suit
every base material
228
234
242
248
1 / 2009
238
11
Anchor selector
Fire tested
Approval
Aerated concrete
Lightweight concrete
Application
Uncracked concrete
Base material
Cracked concrete
Anchor type
HSP/HFPdrywall plug
1)
1)
1)
HTB
= very suitable
12
1) redundant fastening
1 / 2009
Anchor selector
Page
Through-fastening
Pre-setting
Internal thread
External thread
Setting
260
4 8 mm
Controlled setting
Deliverable with or without
prefitted screw
Self-drilling tip
One bit for anchor and screw
Removable
272
276
280
Approved (DIBt)
Fire resistance
Immediately loadable
286
Without
predrilling
Thread:
M6 M10
Drill bit dia.:
10 14 mm
Thread:
M6 M10
Drill bit dia.:
13 14 mm
1 / 2009
Specification
Steel, sheradised, hot dipped galv.
Drill bit
diameter resp.
anchor size
Steel, galvanised
Advantages
264
266
268
292
296
13
Anchor selector
Fire tested
Approval
Aerated concrete
IDP insulation
fastener
Cracked concrete
Lightweight concrete
Application
Base material
Uncracked concrete
Anchor type
Insulation fasteners
= very suitable
14
1 / 2009
Anchor selector
Corrosion resistant
No heat bridge
Reliable bonding of plaster
1 / 2009
Page
Through-fastening
Pre-setting
Internal thread
Setting
External thread
Specification
Steel, sheradised, hot dipped galv.
Drill bit
diameter resp.
anchor size
Steel, galvanised
Advantages
300
304
308
15
Anchor selector
HIT-RE
500SD
HIT-RE
500
Fire tested
HVU
adhesive
anchor
Approval
Application
Lightweight concrete
HVZ
adhesive
anchor
Aerated concrete
Uncracked concrete
Base material
Cracked concrete
Anchor type
Adhesive anchor
systems
Foil capsule systems
Heavy-duty fastenings with small
spacing and edge distances
Adhesive anchor
= very suitable
16
1 / 2009
Anchor selector
Page
Through-fastening
Pre-setting
External thread
Internal thread
No expansion pressure
M10 M20
Small edge distances and
spacing
A strong and flexible foil capsule
Setting
Specification
Steel, sheradised, hot dipped galv.
Drill bit
diameter resp.
anchor size
Steel, galvanised
Advantages
314
No expansion pressure
Small edge distances and
spacing
A strong and flexible foil capsule
HAS M8 M39
HIS-M8 - M20
Rebar dia.
8 40 mm
328
HAS M8 M30
HIS-M8 - M20
Rebar dia.
8 32 mm
352
No expansion pressure
Flexibility in terms of drill bit
diameter and annular gap
Flexibility in terms of working
time
HAS M8 M39
HIS-M8 - M20
Rebar dia.
8 40 mm
410
1 / 2009
17
Anchor selector
Fire tested
Approval
Application
Lightweight concrete
Aerated concrete
Uncracked concrete
Base material
Cracked concrete
Anchor type
HIT-TZ
injection
adhesive
anchor
HIT-HY
150
Adhesive anchor
Adhesive anchor
HIT ICE
HIT-HY
70
= very suitable
18
1 / 2009
Anchor selector
Easy setting
Flexibility in use and planning
Setting by hand
M8 M20
No expansion pressure
No styrene content
No plasticizer content
Environmental protection due to
the minimized packaging
HAS M8 M30
HIS-M8 - M20
Rebar dia.
8 25 mm
No expansion pressure
HAS M8 M24
HIS-M8 - M20
Rebar dia.
8 25 mm
No expansion pressure
mortar filling control
with HIT-SC sleeves
1 / 2009
466
514
526
Through-fastening
Pre-setting
Internal thread
HAS M8 M30
HIS-M8 - M20
Rebar dia.
8 25 mm
Page
External thread
No expansion pressure
No styrene content
No plasticizer content
Environmental protection due to
the minimized packaging
Steel, galvanised
Setting
Specification
Stainless steel A2 (1.4303)
Drill bit
diameter resp.
anchor size
Advantages
574
622
19
Legal environment
Legal environment
Technical data
The technical data presented in this Anchor Fastening Technology Manual are all based on
numerous tests and evaluation according to the state-of-the art. Hilti anchors are tested in our
test labs in Kaufering (Germany), Schaan (Principality of Liechtenstein) or Tulsa (USA) and
evaluated by our experienced engineers and/or tested and evaluated by independent testing
institutes in Europe and the USA. Where national or international regulations do not cover all
possible types of applications, additional Hilti data help to find customised solutions.
In addition to the standard tests for admissible service conditions and suitability tests, for safety
relevant applications fire resistance, shock, seismic and fatigue tests are performed.
1 / 2009
Legal environment
The European Technical Approval Guidelines including related Technical Reports set out the
requirements for anchors and the acceptance criteria they shall meet.
The general assessment approach adopted in the Guideline is based on combining relevant
existing knowledge and experience of anchor behaviour with testing. Using this approach,
testing is needed to assess the suitability of anchors.
The requirements in European Technical Approval Guidelines are set out in terms of objectives
and of relevant actions to be taken into account. ETAGs specify values and characteristics, the
conformity with which gives the presumption that the requirements set out are satisfied,
whenever the state of art permits to do so. The Guidelines may indicate alternate possibilities
for the demonstration of the satisfaction of the requirements.
1 / 2009
21
Approvals
Approvals
International Approvals: Europe
Anchor type
Description
Authority /
Laboratory
No. /
Date of issue
HDA / HDA-R
CSTB, Paris
ETA-99/0009
25.03.2008
CSTB, Paris
ETA-02/0042
10.01.2008
CSTB, Paris
ETA-02/0027
20.09.2007
DIBt, Berlin
ETA-98/0001
18.11.2008
CSTB, Paris
ETA-99/0001
13.03.2008
DIBt, Berlin
ETA-08/307
12.12.2008
DIBt, Berlin
ETA-06/0159
26.07.2006
DIBt, Berlin
ETA-06/0047
30.11.2007
DIBt, Berlin
ETA-02/0032
10.10.2007
DIBt, Berlin
ETA-07/0219
17.12.2012
DIBt, Berlin
ETA-06/0179
13.09.2006
DIBt, Berlin
ETA-04/0043
30.04.2009
ETA-03/0032
03.01.2007
DIBt Berlin
ETA-05/0255
20.01.2006
DIBt Berlin
ETA-05/0256
20.01.2006
HSL-3
HSC / HSC-R
HST / HST-R /
HST-HCR
HSA / HSA-R
HUS HR
6/8/10/14
HUS H
10.5/12.5
HKD / HKD-R
HKD / HKD-R
HRD-U-8
DBZ
HK
HVZ / HVZ-R /
HVZ-HCR
HVU with
HAS / HIS-N
HVU with
HAS-R / HIS-RN
22
DIBt, Berlin
Languages
g
e
f
1 / 2009
Approvals
Anchor type
Description
HVU with
HAS-HCR
DIBt Berlin
Adhesive anchor, rod made out of
highly corrosion resistant steel
(Valid until 20.01.2011)
Injection adhesive anchor, rod made DIBt Berlin
of galvanised, stainless or highly
corrosion resistant steel
(Valid until 08.11.2012)
ETA-05/0257
20.01.2006
ETA-07/0260
12.01.2009
ETA-04/0027
08.01.2008
ETA-08-352
18.12.2008
ETA-04/0084
03.01.2007
ETA-05/0051
20.12.2007
HIT-RE 500-SD
with HIT-V/
HIS-N/
HIT-V-R/ HISRN/ HIT-V-HCR/
rebar BSt 500S
HIT-RE 500 with
HIT-V/ HAS-(E)/
HIS-N/
HIT-V-R/ HAS(E)R/ HIS-RN/
HIT-V-HCR/
HAS-(E)HCR
HIT-HY 150 MAX
with HIT-V/ HAS(E)/ HIS-N/
HIT-V-R/ HAS(E)R/ HIS-RN/
HIT-V-HCR/
HAS-(E)HCR
HIT-TZ /
HIT-RTZ
HIT-HY 150 with
HIT-V/ HAS-(E)/
HIS-N/
HIT-V-R/ HAS(E)R/ HIS-RN/
HIT-V-HCR/
HAS-(E)HCR
Authority /
Laboratory
No. /
Date of issue
Languages
g
e
f
France
Anchor type
Description
Authority /
Laboratory
HPS-1
HIT-HY 70
1 / 2009
No. /
Date of issue
Languages
g
23
Approvals
Germany
Anchor type
Description
Authority /
Laboratory
No. /
Date of issue
HDA
DIBt, Berlin
Z-21.1-1696
01.09.2008
DIBt, Berlin
Z-21.1-1693
12.04.2007
DIBt, Berlin
Z-21.2-599
25.10.2007
DIBt, Berlin
Z-21.1-1710
19.07.2007
Z-21.1-88
10.12.2003
Z-21.1-1721
29.08.2006
DIBt, Berlin
Z-21.1-1729
18.04.2007
DIBt, Berlin
Z-21.1-1722
14.03.2007
DIBt, Berlin
Z-21.3-1692
11.04.2007
DIBt, Berlin
Z-21.8-1648
01.12.2004
Z-21.8-1790
29.11.2007
Z-21.3-1830
17.07.2007
HDA- Dynamic
HRD
HUS,-H/-A 7,5
HA 8-R1
HK
HPD
HKH
HVZ-Dynamic
HIT-HY 150
HIT-RE 500
HIT-HY 70
24
DIBt, Berlin
DIBt, Berlin
DIBt, Berlin
DIBt, Berlin
Languages
g
1 / 2009
Approvals
Switzerland
Anchor type
Description
Authority /
Laboratory
No. /
Date of issue
HDA / HDA-R
Bundesamt fr
Zivilschutz, Bern
BZS D 04-221
02.09.2004
Bundesamt fr
Bevlkerungsschutz, Bern
BZS D 08-601
30.06.2008
Bundesamt fr
Zivilschutz, Bern
BZS D 06-601
17.07.2006
Bundesamt fr
Zivilschutz, Bern
BZS D 03-207/8
13.06.2003
Bundesamt fr
Zivilschutz, Bern
BZS D 04-220
02.09.2004
Description
Authority /
Laboratory
No. /
Date of issue
ICC-ES
1546
01.08.2004
5608
01.02.2004
1545
01.08.2005
5369
01.01.2007
1682
01.01.2006
6010
01.08.2003
1562
1.12..2006
5193
01.01.2007
HSL-3
HSL-3-G
HSL-3-B
HSL-3-SK
HSL-3-SH
HSC-I(R)
HSC-A(R)
HST / HST-R
HVZ / HVZ-R
Languages
g
e
f
USA
Anchor type
HDA
1 / 2009
ICC-ES, ICBO
ICC-ES
ICC-ES
ICC-ES
ICC-ES
ICC-ES
ICC-ES
Languages
g
25
Base materials
Base material
General
Different anchoring conditions
Concrete
A mixture of cement,
aggregates and water
b, D
b, Z
fct
26
1 / 2009
Base materials
Masonry
Masonry is a heterogeneous base material. The hole being drilled for an
anchor can run into mortar joints or cavities. Owing to the relatively low
strength of masonry, the loads taken up locally cannot be particularly high.
A tremendous variety of types and shapes of masonry bricks are on the
market, e.g. clay bricks, sand-lime bricks or concrete bricks, all of different
shapes and either solid or with cavities. Hilti offers a range of different
fastening solutions for this variety of masonry base material, e.g. the HPS1, HRD, HUD, HIT, etc.
If there are doubts when selecting a fastener / anchor, your local Hilti sales
representative will be pleased to provide assistance.
When making a fastening, care must be taken to ensure that a lay of
insulation or plaster is not used as the base material. The specified
anchorage depth (depth of embedment) must be in the actual base
material.
Aerated concrete
Lightweight concrete: This is concrete which has a low density, i.e. 1800
kg/m, and a porosity that reduces the strength of the concrete and thus the
loading capacity of an anchor. Hilti offers the HRD, HUD, HGN, etc anchor
systems for this base material.
Lightweight concrete
1 / 2009
Jobsite tests
27
Base materials
Working principles
There are three basic working principles which make an anchor hold in a building material:
Friction
Keying
Bonding
Combination of working
principles
Many anchors obtain their holding power from a combination of the above
mentioned working principles.
For example, an anchor exerts an expansion force against wall of its hole
as a result of the displacement of a cone relative to a sleeve. This permits
the longitudinal force to be transferred to the anchor by friction. At the same
time, this expansion force causes permanent local deformation of the base
material, above all in the case of metal anchors. A keying action results
which enables the longitudinal force in the anchor to be transferred
additionally to the base material
Force-controlled and
displacement-controlled
expansion anchors
In the case of expansion anchors, a distinction is made between forcecontrolled and movement-controlled types. The expansion force of forcecontrolled expansion anchors is dependent on the tensile force in the
anchor (HSL-3 heavy-duty anchor). This tensile force is produced, and thus
controlled, when a tightening torque is applied to expand the anchor.
In the case of movement-controlled types, expansion takes place over a
distance that is predetermined by the geometry of the anchor in the
expanded state. Thus an expansion force is produced (HKD anchor) which
is governed by the modulus of elasticity of the base material.
Adhesive/resin anchor
28
The synthetic resin of an adhesive anchor infiltrates into the pores of the
base material and, after it has hardened and cured, achieves a local keying
action in addition to the bond.
1 / 2009
Base materials
Failure modes
Effects of static loading
The failure patterns of anchor fastenings subjected to a continually
increased load can be depicted as follows:
1.
2.
3.
3a.
Failure patterns
4.
The weakest point in an anchor fastening determines the cause of failure.
Modes of failure, 1. break-out, 2. anchor pull-away and, 3., 3a., failure of
anchor parts, occur mostly when single anchors that are a suitable
distance from an edge or the next anchor, are subjected to a pure tensile
load. These causes of failure govern the max. loading capacity of anchors.
On the other hand, a small edge distance causes mode of failure 4. edge
breaking. The ultimate loads are then smaller than those of the previously
mentioned modes of failure. The tensile strength of the fastening base
material is exceeded in the cases of break-out, edge breaking and splitting.
Causes of failure
Basically, the same modes of failure take place under a combined load.
The mode of failure 1. break-out, becomes more seldom as the angle
between the direction of the applied load and the anchor axis increases.
Combined load
Shear load
1 / 2009
29
Base materials
Influence of cracks
Very narrow cracks are not It is not possible for a reinforced concrete structure to be built which does
not have cracks in it under working conditions. Provided that they do not
defects in a structure
Efficient utilisation of
reinforcement
Loadbearing mechanisms
a) Non-cracked concrete
b) Cracked concrete
30
1 / 2009
Base materials
Since international testing conditions for anchors are based on the abovementioned crack widths, no theoretical relationship between ultimate
tensile loads and different crack widths has been given.
The statements made above apply primarily to static loading conditions. If
the loading is dynamic, the clamping force and pretensioning force in an
anchor bolt / rod play a major role. If a crack propagates in a reinforced
concrete component after an anchor has been set, it must be assumed that
the pretensioning force in the anchor will decrease and, as a result, the
clamping force from the fixture (part fastened) will be reduced (lost). The
properties of this fastening for dynamic loading will then have deteriorated.
To ensure that an anchor fastening remains suitable for dynamic loading
even after cracks appear in the concrete, the clamping force and
pretensioning force in the anchor must be upheld. Suitable measures to
achieve this can be sets of springs or similar devices
1 / 2009
Pretensioning force in
anchor bolts / rods
31
Anchor design
Anchor design
Safety concept
Depending on the application and the anchor type one of the following two concepts can be applied:
For anchors for use in concrete
having an European Technical
Approval (ETA) the partial safety
factor concept according to the
European
Technical
Approval
Guidelines ETAG 001 or ETAG 020
shall be applied. It has to be shown,
that the value of design actions does
not exceed the value of the design
resistance: Sd Rd.
For the characteristic resistance
given in the respective ETA, reduction factors due to e.g. freeze/thaw,
service temperature, durability, creep
behaviour and other environmental
or application conditions are already
considered.
According ETAG 001, Annex C, the
partial safety factor is G = 1,35 for
permanent actions and Q = 1,5 for
variable actions. In addition to the
design resistance, in this manual
recommended loads are given, using
an overall partial safety factor for
action = 1,4.
32
5% fractile
environmental
conditions
(temperature,
durability)
characteristic
partial safety resistance
(ETA)
factor
design
action
characteristic
value of action
Rd
partial safety
factors
for action
action
mean ultimate
resistance
Sd
for material
(anchor,
base material) design
resistance
recommended
load
resistance
mean ultimate
resistance
5% fractile
characteristic
resistance
(basic value)
global
safety factor
recommended
load
characteristic
value of action
action
resistance
1 / 2009
Anchor design
Design methods
Anchors for use in other base materials and for special applications
If no special calculation method is given, the basic load values given in this manual are valid, as long as the
application conditions (e.g. base material, geometrie, environmental conditions) are observed.
Resistance to fire
When resistance to fire has to be considered, the load values given in the section resistance to fire should be
observed. The values are valid for a single anchor.
1 / 2009
33
Anchor design
NRd,s
NRd,p
NRd,c
NRd,sp
= NRk,s / Ms
*
NRk,s:
Ms:
= (NRk,p / Mp) c
NRk,p:
Mp:
** fB:
c:
34
1 / 2009
Anchor design
where
** fB:
k:
Mc:
+ A0c,N:
+ Ac,N:
+ s,N:
+ re,N:
+ ec,N:
influence of excentricity
** f3,N:
** fre,N:
hef:
1 / 2009
35
Anchor design
where
** fB:
k:
Mc:
++ A0c,N:
++ Ac,N:
+ s,N:
+ re,N:
+ ec,N:
influence of excentricity
** f3,sp:
** f h,sp:
** fre,N:
hef:
36
1 / 2009
Anchor design
VRd,s
VRd,cp
VRd,c
= VRk,s / Ms
VRk,s:
Ms:
1 / 2009
37
Anchor design
NRd,c
where
*
Mc:
+ A0c,N:
+ Ac,N:
+ s,N:
+ re,N:
++ ec,N:
influence of excentricity
** fre,N:
hef:
k:
38
1 / 2009
Anchor design
where
*
Mc:
+ A0c,V:
** f:
** f h:
** f4:
+ Ac,V:
+ s,V:
+ h,V:
++ ,V:
++ ec,V:
influence of excentricity
dnom:
l f:
edge distance
1 / 2009
39
Anchor design
With
N 1
V = VSd / VRd
V 1
N + V 1,2 or N + V 1
2,0
1,5
1,5
NRd,s
NRd,p
NRd,c
NRd,sp
= NRk,s / Ms
*
NRk,s:
Ms:
40
1 / 2009
Anchor design
where
** fh,p:
** fre,N:
Mp:
0
+ A
p,N:
+ Ap,N:
c:
d:
anchor diameter
hef:
Rk:
s:
anchor spacing
scr,Np:
n:
k:
1 / 2009
41
Anchor design
where
*
** fB:
Mc:
** fh,N:
** fre,N:
+ A
c,N:
+ Ac,N:
+ s,N:
+ re,N:
+ ec,N:
influence of excentricity
k1:
hef:
42
1 / 2009
Anchor design
where
*
** fB:
Mc:
** f h,N:
** fre,N:
++ A
c,N:
++ Ac,N:
+ s,N:
+ re,N:
+ ec,N:
influence of excentricity
k1:
+ h,sp:
hef:
embedment depth
1 / 2009
43
Anchor design
VRd,s
VRd,cp
VRd,c
= VRk,s / Ms
VRk,s:
Ms:
NRk,p / Mp
NRd,c
NRk,c / Mc
NRd,p:
NRk,c:
Mp:
Mc:
k:
NRk,c:
** k:
44
1 / 2009
Anchor design
where
** fB:
** f:
** f h:
** f4:
** f hef:
** fc:
= 0,1 (d / c1)0,2
*
Mc:
0
+ A
c,V:
+ Ac,V:
+ s,V:
+ h,V:
++ ,V:
++ ec,V:
influence of excentricity
++ re,V:
influence of reinforcement
k1:
d:
anchor diameter
edge distance
1 / 2009
45
Anchor design
With
N 1
V = VSd / VRd
V 1
N + V 1,2 or N + V 1
46
2,0
1,5
1,5
1 / 2009
Anchor design
1 / 2009
47
Design examples
Design examples
Example 1: mechanical anchor in non-cracked concrete
Anchoring conditions
Non-cracked concrete C40/50
concrete
Group of two anchors close to the edge
number of anchors
base material thickness
h
250 mm
anchor spacing
s
300 mm
edge distance
c
120 mm
shear load direction perpendicular to free edge
90
NSd
TENSION design action (fixing point)
55,0 kN
SHEAR design action (fixing point)
TENSION design action per anchor
VSd
20,0 kN
(1)
27,5 kN
(1)
10,0 kN
NSd
VSd
anchor
effective anchorage depth
hef
scr,sp
380 mm
scr,N
300 mm
ccr,sp
190 mm
ccr,N
150 mm
smin
c
cmin
s
100 mm
240 mm
100 mm
240 mm
minimum spacing
for
HSL-3-G M16
100 mm
General remarks
According ETAG 001, Annex C, concrete cone, splitting, pryout and concrete edge design
resistance must be verified for the anchor group. Steel and pull-out design resistance must be
verified for the most unfavourable anchor of the anchor group.
According to the simplified design method given in this Fastening Technology Manual all
anchors of a group are loaded equally, the design resistance values given in the tables are valid
for one anchor.
48
1 / 2009
Design examples
Tension loading
Design steel resistance
NRd,s =
83,7 kN
N
non-cracked concrete C40/50 fB
Rd,p
NRd,p = N Rd,p fB = -
N
non-cracked concrete C40/50 fB
33,6 kN
Rd,c
1,41
f1,N
0,94
c = 120 mm
ccr,N = 150 mm
c/ccr,N = 0,80
f2,N
0,90
s = 300 mm
anchor
scr,N = 300 mm
s/scr,N = 1,00
HSL-3-G M16
fre,N
1,00
NRd,c = N
f3,N
1,00
=
40,1 kN
N
non-cracked concrete C40/50 fB
1,41
f1,sp
0,89
f2,sp
0,82
f3,sp
2/3
[h/(2hef)] = 2,5 fh,sp
HSL-3-G M16 fre,N
0,89
33,6 kN
Rd,c
c/ccr,sp = 0,63
NRd,sp = N
s/scr,sp = 0,79
1,16
1,00
=
35,7 kN
1 / 2009
NRd = 35,7 kN
49
Design examples
Shear loading
Design steel resistance
VRd,s =
68,6 kN
67,2 kN
basic resistance
V
non-cracked concrete C40/50 fB
concrete
0,94
f2,N
0,90
f3,N
fre,N
1,00
ccr,N = 150 mm
c/ccr,N = 0,80
s = 300 mm
anchor
scr,N = 300 mm
s/scr,N = 1,00
HSL-3-G M16
VRd,cp = V
1,41
f1,N
c = 120 mm
Rd,cp
1,00
80,2 kN
basic resistance
V
non-cracked concrete C40/50 fB
concrete
shear load direction
perpendicular to free edge
h = 250 mm
c = 120 mm
s = 300 mm
1,41
h/c = 2,08 fh
c/hef = 1,20
f4
s/hef = 3,00
90
c = 120 mm
hef = 100 mm
hef = 100 mm
13,7 kN
Rd,c
VRd,c = V
1,20
Rd,c fB f fh f4
46,4 kN
VRd = 46,4 kN
The following equation must be satisfied for combined tension and shear
loads:
1,5
1,5
(Eq. 1)
(N) + (V) 1
N (V ) ratio between design action and design
resistance for tension (shear) loading
According to ETAG 001, Annex C, the following simplified equation may
be applied:
(Eq. 2)
N + V 1,2 and N 1, V 1
0,216
0,986
1,2
3
3
3
0,776
27,5 kN
N = NSd /NRd =
10,0 kN
V = VSd /VRd =
N + V =
NRd =
35,7 kN
VRd =
46,4 kN
50
0,770
(1)
(1)
NSd
VSd
(N)
1,5
+ (V)
1,5
1,2
1
(Eq. 1)
(Eq. 2)
0,8
0,6
0,4
0,2
0
(1)
(1)
1 / 2009
Design examples
Anchoring conditions
Cracked concrete C30/37
concrete
Group of two anchors close to the edge
number of anchors
base material thickness
h
150 mm
anchor spacing
s
70 mm
edge distance
c
120 mm
shear load direction perpendicular to free edge
90
NSd
TENSION design action (fixing point)
10,0 kN
SHEAR design action (fixing point)
VSd
10,0 kN
(1)
5,0 kN
(1)
5,0 kN
NSd
VSd
anchor
effective anchorage depth
hef
scr,sp
270 mm
scr,N
210 mm
ccr,sp
135 mm
ccr,N
105 mm
smin
c
cmin
s
70 mm
100 mm
70 mm
160 mm
minimum spacing
for
HSL-3-SK M10
70 mm
General remarks
According ETAG 001, Annex C, concrete cone, splitting, pryout and concrete edge design
resistance must be verified for the anchor group. Steel and pull-out design resistance must be
verified for the most unfavourable anchor of the anchor group.
According to the simplified design method given in this Fastening Technology Manual all
anchors of a group are loaded equally, the design resistance values given in the tables are valid
for one anchor.
1 / 2009
51
Design examples
Tension loading
Design steel resistance
NRd,s =
30,9 kN
Rd,p
10,7
Rd,p fB
13,1 kN
N
Cracked concrete C30/37 fB
NRd,p = N
1,22
=
N
Cracked concrete C30/37 fB
c = 120 mm
ccr,N = 105 mm
c/ccr,N = 1,14
s = 70 mm
anchor
scr,N = 210 mm
s/scr,N = 0,33
HSL-3-SK M10
0
NRd,c = N
14,1 kN
Rd,c
1,22
f1,N
1,00
f2,N
1,00
fre,N
0,67
f3,N
0,85
=
9,8 kN
N
Cracked concrete C30/37 fB
70 mm scr,sp = 270 mm
hef = 70 mm
h = 150 mm
anchor
1,22
f1,sp
0,97
f2,sp
0,94
f3,sp
2/3
[h/(2hef)] = 2,14 fh,sp
HSL-3-SK M10 fre,N
0,63
c/ccr,sp = 0,89
14,1 kN
Rd,c
NRd,sp = N
s/scr,sp = 0,26
1,05
0,85
=
8,8 kN
52
NRd =
8,8 kN
1 / 2009
Design examples
Shear loading
Design steel resistance
VRd,s =
39,4 kN
28,1 kN
basic resistance
V
Cracked concrete C30/37 fB
concrete
ccr,N = 105 mm
c/ccr,N = 1,14
s = 70 mm
anchor
scr,N = 210 mm
s/scr,N = 0,33
HSL-3-SK M10
0
VRd,cp = V
1,22
f1,N
1,00
f2,N
1,00
f3,N
fre,N
0,67
c = 120 mm
Rd,cp
0,85
19,5 kN
basic resistance
V
Cracked concrete C30/37 fB
concrete
shear load direction
perpendicular to free edge
h = 150 mm
c = 120 mm
s=
70 mm
1,22
h/c = 1,25 fh
c/hef = 1,71
f4
s/hef = 1,00
0,88
90
c = 120 mm
hef = 70 mm
hef = 70 mm
4,6 kN
Rd,c
VRd,c = V
1,34
Rd,c fB f fh f4
13,2 kN
VRd = 13,2 kN
The following equation must be satisfied for combined tension and shear
loads:
1,5
1,5
(Eq. 1)
(N) + (V) 1
N (V ) ratio between design action and design
resistance for tension (shear) loading
According to ETAG 001, Annex C, the following simplified equation may
be applied:
(Eq. 2)
N + V 1,2 and N 1, V 1
0,567
(1)
0,378
0,945
1,2
3
3
3
0,659
5,0 kN
N = NSd /NRd =
(1)
5,0 kN
V = VSd /VRd =
N + V =
NSd
NRd =
8,8 kN
VRd =
13,2 kN
1 / 2009
( N)
1,5
+ ( V)
1,5
1,2
1
(Eq. 1)
(Eq. 2)
0,8
0,6
0,4
0,2
0
(1)
(1)
53
Design examples
Anchoring conditions
concrete
Non-cracked concrete C50/60
service temperature
temperature range II
range of base material
Group of two anchors close to the edge
number of anchors
base material thickness
h
100 mm
anchor spacing
s
150 mm
edge distance
c
100 mm
shear load direction perpendicular to free edge
0
NSd
TENSION design action (fixing point)
15,0 kN
SHEAR design action (fixing point)
VSd
NSd
VSd
hef
15,0 kN
(1)
7,5 kN
(1)
7,5 kN
70 mm
smin
60 mm
minimum spacing
cmin
60 mm
70 mm
210 mm
critical edge distance for concrete cone failure ccr,N and critical edge distance for
combined pull-out and concrete cone failure ccr,Np
hef =
70 mm
h = 100 mm
hef =
105 mm
for h 2 hef
70 mm
h/hef = 1,43
ccr,sp =
scr,sp = 2 ccr,sp =
142 mm
284 mm
General remarks
According EOTA Technical Report TR 029, concrete cone, combined concrete cone and pullout, splitting, pryout and concrete edge design resistance must be verified for the anchor group.
Steel design resistance must be verified for the most unfavourable anchor of the anchor group.
According to the simplified design method given in this Fastening Technology Manual all
anchors of a group are loaded equally, the design resistance values given in the tables are valid
for one anchor.
1 / 2009
54
Design examples
Tension loading
Design steel resistance
NRd,s =
28,0 kN
basic resistance
concrete
hef = 70 mm hef,typ =
N Rd,p
Non-cracked concrete C50/60 fB,p
fh,p = hef/hef,typ =
110 mm
29,9 kN
1,09
0,64
c = 100 mm
ccr,N = 105 mm
c/ccr,N = 0,95
f1,N
0,99
f2,N
0,97
s = 150 mm
hef = 70 mm
scr,N = 210 mm
s/scr,N = 0,71
f3,N
fre,N
0,86
NRd,p = N
1,00
=
17,1 kN
N
Non-cracked concrete C50/60 fB
concrete
hef = 70 mm
hef,typ = 110 mm
c = 100 mm
ccr,N = 105 mm
c/ccr,N = 0,95
s = 150 mm
hef = 70 mm
scr,N = 210 mm
s/scr,N = 0,71
1,55
fh,N = (hef/hef,typ)
NRd,c = N
32,4 kN
Rd,c
1,5
0,51
f1,N
0,99
f2,N
0,97
fre,N
0,86
f3,N
1,00
=
21,1 kN
N
Non-cracked concrete C50/60 fB
hef,typ = 110 mm
32,4 kN
Rd,c
fh,N = (hef/hef,typ)
1,55
1,5
0,51
f1,sp
0,91
c = 100 mm
ccr,sp = 142 mm
c/ccr,sp = 0,70
f2,sp
0,85
s = 150 mm
hef = 70 mm
scr,sp = 284 mm
s/scr,sp = 0,53
f3,sp
fre,N
0,76
NRd,sp = N
1,00
=
15,0 kN
1 / 2009
NRd =
15,0 kN
55
Design examples
Shear loading
Design steel resistance
VRd,s =
16,8 kN
17,1 kN
V =
k
0
VRd,cp = k V =
70 mm
2
34,3 kN
basic resistance
V
Non-cracked concrete C50/60 fB
concrete
shear load direction
perpendicular to free edge
h = 100 mm
c = 100 mm
s = 150 mm
hef = 70 mm
c=
100 mm
c = 100 mm
hef = 70 mm
hef = 70 mm
d=
12 mm
d=
12 mm
1,55
1,00
h/c = 1,00 fh
c/hef = 1,43
f4
s/hef = 2,14
0,82
1,28
fhef
c/d = 8,33 fc
hef/d = 5,83
0
VRd,c = V
11,6 kN
Rd,c
0,97
0,67
Rd,c fB f fh f4 fhef fc
12,3 kN
VRd =
12,3 kN
The following equation must be satisfied for combined tension and shear
loads:
1,5
1,5
(Eq. 1)
(N) + (V) 1
N (V ) ratio between design action and design
resistance for tension (shear) loading
According to ETAG 001, Annex C, the following simplified equation may
be applied:
(Eq. 2)
N + V 1,2 and N 1, V 1
(1)
(1)
=
=
7,5 kN
7,5 kN
NRd =
15,0 kN
VRd =
12,3 kN
56
(1)
N = NSd /NRd =
(1)
V = VSd /VRd =
N + V =
( N)
1,5
+ ( V)
1,5
(Eq. 1)
(Eq. 2)
0,8
0,6
0,4
0,2
0
0,500
0,612
1,112
1,2
3
3
3
0,832
1 / 2009
Design examples
1 / 2009
57
Corrosion
Corrosion
Material recommendations to counteract corrosion
Application
General conditions
Recommendations
Temporary fastening:
Forming, site fixtures,
scaffolding
Galvanised or coated
Structural fastening:
Brackets, columns, beams
Hot-dipped galvanised /
sherardized
min. 45 microns
Inside
application
Outside
application
Hot-dipped galvanised /
sherardized min. 45 microns
Insulating
materials
Town / city
atmosphere:
High SO2 and Nox
contents, chlorides
from road salt can
accumulate/
concentration on
parts not weathered
directly
Inside
application
Outside
application
Hot-dipped galvanised /
sherardized min. 45 microns,
Hilti-HCR if chlorides exist
Insulating
materials
A4 (316) steels
Industrial
atmosphere: High
SO2 content and
other corrosive
substances (without
halides)
Inside
application
Outside
application
A4 (316) steels
Insulating
materials
A4 (316) steels
Coastal atmosphere:
High content of
chlorides, combined
with industrial
atmosphere
Inside
application
Outside
application
Hilti-HCR
Insulating
materials
Hilti-HCR
Initial/carcass construction
Composite construction
Interior finishing
Drywalls, suspended ceilings,
windows, doors, railings /
fences, elevators, fire escapes
Facades / roofing
Profiled metal sheets, curtain
wall cladding, insulation
fastenings, facade support
framing
58
Rural atmosphere
(without emissions)
1 / 2009
Corrosion
Application
General conditions
Recommendations
Hot-dipped galvanised /
sherardized min. 45 microns
Hot-dipped galvanised /
sherardized min. 45 microns, A4
(316) steels, Duplex steel or
austenitic steel with approx. 4-5%
Mo
Hilti HCR
Hilti-HCR
Hot-dipped galvanised
Hilti-HCR
A4 (316) steels
A4 (316) steels
A4 (316) steels
Installations
Conduit installation, cable runs,
air ducts
Electrical systems:
Runs, lighting, aerials
Industrial equipment:
Crane rails, barriers, conveyors,
machine fastening
Tunnel construction
Tunnel foils / sheeting,
reinforcing mesh, traffic signs,
lighting, tunnel wall cladding /
lining, air ducts, ceiling
suspensions, etc.
Dock/harbour/port facilities /
off-shore rigs
Fastenings to quaysides, dock /
harbour
Power plants
Fastenings relevant to safety
1 / 2009
59
Corrosion
Application
General conditions
Recommendations
Hot-dipped galvanised/sherardized
min. 45 microns A4 (316) steels
Hilti-HCR
Hot-dipped galvanised/sherardized
min. 45 microns A4 (316) steels
Hilti-HCR
Hilti-HCR
Hilti-HCR
In rural atmosphere
Hot-dipped galvanised /
sherardized min. 45 microns
Hot-dipped galvanised /
sherardized min. 45 microns A4
(316) steels
Inaccessible fastenings
A4 (316) steels
Smokestacks of waste
incineration plants
Fastening of, for example,
service ladders, lightening
conductors
60
1 / 2009
Corrosion
The following table shows the suitability of the respective metal couple. It also shows which two
metals in contact are permissible in field practice and which should rather be avoided.
Metal couples
1 / 2009
61
Dynamic
Dynamic
Dynamic design for anchors
Detailed informations are available from your local Hilti partner or in the brochure:
Dynamic Design for Anchors, Hilti AG, 2001 W 2611 0601 20-e
Actions
Static loads
Dynamic actions
Fatigue loads
Seismic loads
Shock loads
Two main groups of fatigue type loading can be identified:
Actions causing fatigue have a large number of load cycles which produce
changes in stress in the affected fastening. These stresses result in a
decrease in strength, which is all the greater the larger the change in stress
and the larger the number of load cycles are (fatigue). When evaluating
actions causing fatigue, not only the type of action, but also the planned or
anticipated fastening life expectancy is of major importance.
Earthquakes /
seismic actions
62
1 / 2009
Dynamic
Shock
Material behaviour
The behaviour is described essentially by the strength (tensile and
compressive) and the elastic-plastic behaviour of the material. These
properties are generally determined by carrying out simple tests with
specimens.
1 / 2009
63
Dynamic
Anchor behaviour
Fatigue
Earthquakes
Shock
In this respect, more recent investigations show that the base material
(cracked or non-cracked concrete), has no direct effect on the load-bearing
behaviour.
Both mechanical and chemical anchors are basically suitable for fastenings
subjected to fatigue loading. Hilti manufactures the HDA and HVZ anchors
of special grades of steel resistant to fatigue and has also subjected them
to suitable tests.
64
1 / 2009
Dynamic
row of
load-bearing
anchors
edge of
concrete
member
V
row of
non load-bearing
anchors
Concrete
failure surface
The second row of anchors can be activated only after a considerable slip
of the anchoring plate. This slip normally takes place after the edge failure
of the outside row. The effect of the clearance hole gap on the internal load
distribution increases if the shear load direction changes during the service
life. To make anchors suitable for alternating shear loads, Hilti developed
the so called Dynamic Set. This consists of a special washer, which permits
HIT injection adhesive to be dispensed into the clearance hole, a spherical
washer, a nut and a lock nut.
Dynamic Set
perspective
Injection
washer
Injection washer:
plan view
spherical
washer
nut
lock
nut
Improvements
with Dynamic Set
1 / 2009
65
Dynamic
Shear resistance improvement By using the dynamic set for static fastenings, the shear resistance is
improved significantly. The unfavourable situation that only one row of
with Dynamic Set
anchors takes up all loads no longer exists and the load is distributed
uniformly among all anchors. A series of experiments has verified this
assumption. An example from this test programme, double fastenings with
HVZ M10 anchors with and without the Dynamic Set are shown to compare
resulting shear resistance and stiffness.
not injected
injected
Member edge
With
Dynamic Set
(extended Hilti
method)
Without
Dynamic Set
(ETAG)
The test results show clearly that according to the current practice the
second row of anchors takes up the load only after significant deformation
of the plate, when the concrete edge has already failed. The injection and
the Dynamic Set resulted in a continuous load increase until the whole
multiple fastening fails.
When carrying out a simple fastening design, it may be assumed if the
Dynamic Set is used the overall load bearing capacity of the multiple
fastening is equal to the resistance of the first row of anchors multiplied by
the number of rows in the fastening. In addition to that it must be checked
whether the concrete edge resistance of the farest row is smaller than the
above metioned resistance. If injection with the Dynamic Set is used, the
ETAG restrictions on more than 6 anchor fastenings can be overcome.
66
1 / 2009
Dynamic
1 / 2009
67
Resistance to fire
Resistance to fire
Tested fasteners
for passive structural fire prevention
Tested according to the international standard temperature curve
MFPA Leipzig
GmbH
Anchor / fastener
HDA
HDA-R
HSL-3
68
Size
F60
F90
F120
M10
4,5
2,2
1,3
1,0
M12
10,0
3,5
1,8
1,2
M16
15,0
7,0
4,0
3,0
M20
25,0
9,0
7,0
5,0
M10
4,5
2,2
1,3
1,0
M12
10,0
3,5
1,8
1,2
M16
15,0
7,0
4,0
3,0
Warringtonfire
WF Report No 166402
M10
20,0
9,0
4,0
2,0
IBMB Braunschweig
UB 3039/8151
M12
30,0
12,0
5,0
3,0
M16
50,0
15,0
7,5
6,0
M8
3,0
1,1
0,6
0,4
M10
7,0
2,0
1,3
0,8
M12
10,0
3,5
2,0
1,2
M16
19,4
6,6
3,5
2,2
M20
30,0
10,3
5,4
3,5
M24
43,0
14,8
7,9
5,0
IBMB Braunschweig
UB 3039/8151
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3039/8151
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3041/1663-CM
Warringtonfire
WF Report No 166402
1 / 2009
Resistance to fire
Anchor / fastener
HSL-3-G
HSL-3-B
HSL-3-SH
HSL-3-SK
HSC-A
HSC-I
HSC-AR
HSC-IR
HST
1 / 2009
Size
F60
F90
F120
3,0
1,1
0,6
0,4
M10
7,0
2,0
1,3
0,8
M12
10,0
3,5
2,0
1,2
M16
19,4
6,6
3,5
2,2
M20
30,0
10,3
5,4
3,5
M24
43,0
14,8
7,9
5,0
M12
10,0
3,5
2,0
1,2
M16
19,4
6,6
3,5
2,2
M20
30,0
10,3
5,4
3,5
M24
43,0
14,8
7,9
5,0
M8
1,9
1,1
0,6
0,4
M10
4,5
2,0
1,3
0,8
M12
8,5
3,5
2,0
1,2
Warringtonfire
WF Report No 166402
M8
3,0
1,1
0,6
0,4
IBMB Braunschweig
report No. 3041/1663-CM
M10
7,0
2,0
1,3
0,8
M12
10,0
3,5
2,0
1,2
M8x40
M8x50
M10x40
1,5
1,5
1,5
M12x60
3,5
2,0
M8x40
M10x50
M10x60
1,5
2,5
2,5
M12x60
2,0
M8x40
M8x50
M10x40
M12x60
M8x40
M10x50
M10x60
1,5
1,5
1,5
3,5
1,5
2,5
2,5
3,0
-
M12x60
3,5
3,0
M8
M10
M12
M16
M20
M24
0,9
2,5
5,0
9,0
15,0
20,0
0,7
1,5
3,5
6,0
10,0
15,0
0,6
1,0
2,0
3,5
6,0
8,0
0,5
0,7
1,0
2,0
3,5
5,0
M8
IBMB Braunschweig
report No, 3041/1663-CM
Warringtonfire
WF Report No 166402
IBMB Braunschweig
report No. 3041/1663-CM
Warringtonfire
WF Report No 166402
IBMB Braunschweig
report No. 3041/1663-CM
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3177/1722-1
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3177/1722-1
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3177/1722-1
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3177/1722-1
Warringtonfire
WF Report No 166402
DIBt Berlin
ETA-98/0001
Warringtonfire
WF Report No 166402
69
Resistance to fire
Anchor / fastener
HST-R
HST-HCR
HSA
HSA-R
HLC-Standard
HLC-H
Size
F60
F90
F120
M8
M10
M12
M16
M20
M24
4,9
11,8
17,2
32,0
49,9
71,9
3,6
8,4
12,2
22,8
35,5
51,2
2,4
5,0
7,3
13,5
21,1
30,4
1,7
3,3
4,8
8,9
13,9
20,0
M8
4,9
3,6
2,4
1,7
M10
11,8
8,4
5,0
3,3
M12
17,2
12,2
7,3
4,8
M16
32,0
22,8
13,5
8,9
M6
M8
M10
M12
M16
M20
M6
M8
M10
M12
M16
6,5 (M5)
8 (M6)
10 (M8)
12(M10)
16(M12)
20(M16)
0,9
1,5
4,5
10,0
15,0
25,0
2,6
6,0
9,5
14,0
26,0
0,5
0,9
1,9
3,0
4,0
4,0
0,5
0,8
2,2
3,5
7,0
9,0
1,3
3,0
4,7
7,0
13,0
0,29
0,5
0,99
1,5
2,2
3,7
0,3
0,5
1,3
1,8
4,0
7,0
0,8
1,8
3,0
4,0
7,5
0,2
0,37
0,6
1,0
1,5
2,7
0,25
0,4
1,0
1,2
3,0
5,0
0,6
1,2
2,5
3,0
6,0
0,17
0,3
0,5
0,8
1,1
2,2
8 (M6)
0,9
0,5
0,37
0,3
10 (M8 )
1,9
0,99
0,6
0,5
12(M10)
3,0
1,5
1,0
0,8
16(M12)
4,0
2,2
1,5
70
Warringtonfire
WF Report No 166402
DIBt Berlin
ETA-98/0001
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3049/8151
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3049/8151
Warringtonfire
WF Report No 166402
IBMB Braunschweig
PB 3093/517/07CM
Warringtonfire
WF Report No 166402
IBMB Braunschweig
PB 3093/517/07-CM
Warringtonfire
1,18 WF Report No 166402
HLC-L
HLC-EC
DIBt Berlin
ETA-98/0001
10 (M8)
1,9
0,99
0,67
0,5
8 (M6)
0,9
0,5
0,37
0,3
10 (M8)
1,9
0,99
0,67
0,5
16(M12)
3,0
1,5
1,0
IBMB Braunschweig
PB 3093/517/07-CM
Warringtonfire
WF Report No 166402
IBMB Braunschweig
PB 3093/517/07-CM
Warringtonfire
WF Report No 166402 &
0,79 WF Report No 172920
1 / 2009
Resistance to fire
Anchor / fastener
Size
HUS -HR
(concrete and solid brick)
HUS-H/HUS-HF
HKD-S
HKD-SR
HRD-U10
1 / 2009
HKD-E
HKD-ER
F60
F90
F120
5,5
3,5
1,4
0,4
DIBt Berlin
ETA-08/0307
9,3
6,3
3,2
1,7
18,5
12,0
5,4
2,4
14
41,7
26,9
12,2
5,4
10,5
7,0
2,6
1,5
1,0
IBMB Braunschweig
UB 3574/5146
9,0
3,3
1,8
1,2
Warringtonfire
WF Report No 166402
7,5
1,2
0,7
0,5
0,4
-H 7,5
1,3
0,8
0,6
0,5
-A 7,5
1,8
1,2
0,8
0,7
16,5
HUS
(gas concrete, plates and bricks,
strength catgegory > 6 )
F30
10
12,5
HUS
(concrete and solid brick)
7,5
-H 7,5
1,0
0,6
0,4
0,3
M6
2,0
M8
3,0
M10
5,0
M12
8,5
M16
11,5
M20
18,8
S M6x30
0,7
E M6x30
S M8x30
0,8
E M8x30
S M10 x30 0,9
S M8x40
1,0
E M8x40
S M10x40
1,5
E M10x40
S M12x50
1,5
E M12x50
M8x30
0,8
1,0
1,1
2,0
3,5
7,5
14,0
0,4
0,6
1,3
2,0
4,0
7,0
0,3
0,4
0,8
1,2
3,0
5,0
0,6
0,4
0,3
0,6
0,4
0,3
0,9
0,7
0,4
0,6
0,4
0,3
1,3
0,7
0,4
1,5
1,5
1,2
0,6
0,4
0,3
M10x40
1,5
1,3
0,7
0,4
M12x50
1,5
1,5
1,5
1,2
load angle
10
70
1,6
1,6
1,6
1,6
0,8
1,4
0,8
90
1,6
1,6
1,6
0,8
-A 7,5
IBMB Braunschweig
UB 3574/5146
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3574/5146
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3027/0274-4 &
Br.082/Nau; Br. 078/97-Nau-;
Br. 080/97-Nau
Warringtonfire
WF Report No 166402
DIBt Berlin
ETA-06/0047 acc. Part 6
Warringtonfire
WF Report No 166402
DIBt Berlin
ETA-06/0047 acc. Part 6
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB 3613/3891-1 -Nau-
71
Resistance to fire
Anchor / fastener
Size
load angle
10
70
90
HRD-S10
HRD-U8x80/30
only shear
loads
F60
F90
1,2
1,2
1,2
0,8
1,4
1,6
0,8
0,8
1,9
1,4
1,0
0,7
0,20
0,10
0,6
0,5
0,3
0,2
6/4,5
6/35
0,8
0,4
0,2
0,1
IBMB Braunschweig
UB 3794/7949-1
HT 8 L
0,85
0,44
0,27
0,74
0,41
0,3
6/4,5
6/35
HT 10 L
HT 10 S
HK + HK L
M6
0,8
0,5
0,3
0,2
HK
M8
1,4
1,0
0,6
0,4
M6
M8
M10
M12
0,85
1,4
2,2
2,2
1,2
0,5
0,7
1,3
1,3
0,65
0,35
0,45
0,95
0,95
0,45
0,3
0,35
0,75
0,75
0,35
IBMB Braunschweig
UB 3077/3602 -Nau-
M6
M8
M10
IBMB Braunschweig
1,8
0,95 0,65
0,5 UB 3606 / 8892
Warringtonfire
3,0
1,55 1,05 0,85 WF Report No 166402
0,45 0,35 DIBt Zulassung
0,65
0,5
0,8
0,8 Z-21.1-1722
IBMB Braunschweig
Tested withTektalan-slabs
PB 3136/2315
classification according to DIN
EN 13 502-2:2003 for REI 90
and RE 90 recommended
M10
M12
M16
M20
M10
M12
M16
M20
4,5
10,0
15,0
25,0
10,0
15,0
20,0
35,0
2,2
3,5
7,0
9,0
4,5
7,5
11,5
18,0
1,3
1,8
4,0
7,0
2,7
4,0
7,5
11,5
1,0
1,2
3,0
5,0
1,7
3,0
6,0
9,0
IBMB Braunschweig
UB 3357/0550-1
HPD
HKH/HKH-L
M6
M8
M10
IDMS/IDMR
HVZ + HAS-TZ
HVZ + HAS-R/HAS-HCR-TZ
72
MFPA Leipzig
PB III/B-07-306
0,35
HT
IBMB Braunschweig
UB 3613/3891-2 -Nau-
IBMB Braunschweig
UB 3245/1817-5
0,05
Warringtonfire
WF Report No 166402
HA 8 R1
DBZ
F120
Warringtonfire
WF Report No 166402
Warringtonfire
WF Report No 166402
1 / 2009
Resistance to fire
Anchor / fastener
HVU + HAS
HVU + HAS-R/HAS-E-R +
HVU + HAS-HCR/HAS-E-HCR
HVU + HIS-N
HVU + HIS-RN
1 / 2009
Size
F60
F90
F120
1,5
4,5
10,0
15,0
25,0
35,0
40,0
50,0
60,0
70,0
85,0
2,0
6,0
10,0
20,0
36,0
56,0
65,0
85,0
1,5
4,5
10,0
15,0
0,8
2,2
3,5
5,0
9,0
12,0
13,5
17,0
20,0
24,0
29,0
0,8
3,5
6,0
13,5
25,5
38,0
44,0
58,0
68,0
82,0
96,0
0,8
2,2
3,5
5,0
0,5
1,3
1,8
4,0
7,0
9,5
11,0
14,0
16,5
19,5
23,5
0,5
1,5
3,0
7,5
15,0
24,0
27,0
36,0
42,0
51,0
60,0
0,5
1,3
1,8
4,0
0,4
0,9
1,0
3,0
5,0
8,0
9,0
11,0
13,5
16,0
19,5
0,4
1,0
2,5
6,0
10,0
16,0
18,0
24,0
28,0
34,0
40,0
0,4
0,9
1,0
3,0
M20
25,0
9,0
7,0
5,0
M8
M10
M12
M16
10,0
20,0
30,0
50,0
5,0
9,0
12,0
15,0
1,8
4,0
5,0
7,5
1,0
2,0
3,0
6,0
M20
65,0
35,0
15,0
10,0
M8
M10
M12
M16
M20
M24
M27
2,3
3,7
5,3
10,0
15,6
22,5
29,2
1,08
1,9
2,76
5,4
8,46
15,8
0,5
0,96
1,59
3,1
4,5
7,0
9,1
0,28
0,59
1,0
1,97
2,79
4,4
5,7
M30
35,7
19,3
11,1
7,0
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
M8
M10
M12
M16
100,0
120,0
140,0
12,19
IBMB Braunschweig
UB- 3333/0891-1
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB- 3333/0891-1
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB- 3333/0891-1
Warringtonfire
WF Report No 166402
IBMB Braunschweig
UB- 3333/0891-1
Warringtonfire
WF Report No 166402
MFPA Leipzig
GS-lll/B-07-070
Warringtonfire
WF Report No 172920
Loads for standard embedment
depth, for variable embedment
depth see test report.
73
Resistance to fire
Anchor / fastener
HIT-RE 500-SD +
HIT-VR/HIT-V-HCR
74
Size
F60
F90
F120
M8
M10
M12
M16
M20
M24
M27
2,42
3,8
6,5
12,1
18,8
27,2
35,3
1,08
1,9
4,2
8,6
15,9
23,0
29,9
0,5
0,96
2,3
4,8
12,2
18,8
24,4
0,28
0,59
1,5
3,2
10,5
16,7
21,7
M30
43,2
36,5
29,9
26,5
M8
2,3
1,26
0,73
M10
3,7
2,0
1,15
M12
5,3
2,9
1,68
M16
10,0
5,4
3,1
1,06 Warringtonfire
WF Report No 172920
1,97
M20
15,6
8,4
4,87
3,08
M8
2,4
1,88
1,3
M10
3,8
2,98
2,1
M12
6,5
5,5
4,5
4,0
M16
12,1
10,2
8,3
7,4
M20
18,8
15,9
13,0
11,6
8 mm
10 mm
12 mm
14 mm
16 mm
20 mm
25 mm
28 mm
32 mm
36 mm
40 mm
2,35
5,6
12,7
24,6
39,1
48,9
95,7
1,02
2,4
5,3
10,8
21,3
26,6
67,8
0,47
1,3
2,97
6,1
11,9
14,9
48,4
0,26
0,8
2,0
4,19
8,1
10,1
34,3
259,0
225,1
200,1
182,2
327,8
290,5
262,5
242,3
404,7
364,3
333,1
310,7
MFPA Leipzig
GS-lll/B-07-070
Warringtonfire
WF Report No 172920
Loads for standard embedment
depth, for variable embedment
depth see test report.
Warringtonfire
WF Report No 172920
MFPA Leipzig
GS-lll/B-07-070
Warringtonfire
WF Report No 172920
1 / 2009
Resistance to fire
Anchor / fastener
1 / 2009
Size
F60
F90
F120
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
2,3
3,7
5,3
10,0
15,6
22,5
29,2
35,7
44,2
58,5
62,2
2,4
3,8
6,5
12,1
18,8
27,2
35,3
43,2
53,4
70,6
75,2
1,26
2,0
2,9
5,4
8,4
12,1
15,8
19,3
23,9
31,6
33,6
1,88
2,98
5,5
10,2
15,9
23,0
29,9
36,5
45,2
59,7
63,6
0,73
1,15
1,68
3,1
4,8
7,0
9,1
11,1
13,8
18,2
19,4
1,34
2,1
4,5
8,3
13,0
18,8
24,4
29,9
37,0
48,9
52,0
0,46
0,73
1,06
1,97
3,08
4,4
5,7
7,0
8,7
11,5
12,2
1,07
1,69
4,0
7,4
11,6
16,7
21,7
26,5
32,8
43,4
46,2
IBMB Braunschweig
PB 3588/4825-CM,
& supplement letter 412/2008
M8
2,3
1,2
0,7
0,4
M10
3,7
2,0
1,1
0,7
IBMB Braunschweig
PB 3588/4825-CM Brunswick
M12
5,3
2,9
1,68
M16
10,0
5,4
3,1
M20
15,6
8,4
4,87
1,06 Warringtonfire
WF Report No 166402 &
1,97
WF Report No 172920
3,08
M8
2,3
1,2
0,7
0,4
M10
3,8
2,98
2,1
1,69
M12
6,5
5,5
4,5
4,0
M16
12,1
10,2
8,3
7,4
M20
18,9
15,9
13,0
11,6
M8
1,9
0,5
0,25
M10
6,0
1,1
0,4
M12
9,0
2,5
1,2
0,7
M16
17,0
6,5
3,7
2,5
M20
20,0
11,0
7,7
6,0
Warringtonfire
WF Report No 166402 &
WF Report No 172920
IBMB Braunschweig
Test Report 3565 / 4595,
& supplement letter 414/2008
Warringtonfire
WF Report No 166402 &
WF Report No 172920
IBMB Braunschweig
PB 3588/4825-CM Brunswick
Warringtonfire
WF Report No 166402 &
WF Report No 172920
Warringtonfire
WF Report No 166402
75
Resistance to fire
Anchor / fastener
HIT-HY 70 hef = 80 mm
(HLz, MVz, KSL, KSV)
Size
M8
M10
M12
M16
M20
M24
M27
M30
M8
M10
M12
M16
M20
M24
M27
M30
M8
F60
F90
F120
2,7
3,6
6,0
7,0
12,5
16,0
28,5
34,5
2,7
3,6
6,0
7,0
12,5
16,0
29,9
36,5
1,1
1,9
3,5
5,0
10,0
12,5
24,0
29,3
1,3
1,9
4,6
5,0
10,0
12,5
24,0
29,3
0,5
1,0
2,0
3,2
7,0
10,0
14,8
18,1
0,5
1,0
2,3
3,2
8,0
10,0
14,8
18,1
0,4
0,6
1,2
2,0
5,0
8,0
10,2
12,5
0,4
0,6
1,6
2,0
6,5
8,5
10,2
12,5
2,0
0,4
0,2
IBMB Braunschweig
UB 3027/0274-6
& supplement letters
Br. 080/Nau & 416/2008
Warringtonfire
WF Report No 166402 &
WF Report No 172920
IBMB Braunschweig
UB 3027/0274-6
& supplement letters
Br. 080/Nau & 416/2008
Warringtonfire
WF Report No 166402 &
WF Report No 172920
MFPA Leipzig
PB III/B-07-157
Warringtonfire
WF Report No 166402
76
M10
2,0
0,4
0,2
M12
2,0
0,4
0,2
M8
M10
M12
M8
M10
M12
M8
M10
M12
2,0
3,6
5,9
2,0
2,0
2,0
2,0
2,0
2,0
1,2
1,9
3,0
0,4
0,4
0,4
0,8
1,0
1,2
0,7
1,1
1,5
0,2
0,2
0,2
0,6
0,8
1,0
M6
0,7
0,4
0,2
MFPA Leipzig
PB III/B-07-157
Warringtonfire
WF Report No 166402
1 / 2009
Resistance to fire
Tested fasteners
for passive structural fire prevention
Tested according to the german tunnel temperature curve
Anchor / fastener
Size
HST-HCR
M10
1,0
M12
1,5
M16
2,5
M20
6,0
M20
0,20 a)
0,30 a)
0,50 a)
1,10 a)
0,5
0,8
2,5
5,0
6,0
M10
1,5
M12
2,5
M16
6,0
M20
8,0
M8
0,5
M10
1,5
M12
1,5
M16
5,0
HUS-HR
8
10
14
HKD-SR
M8
M10
M12
M16
HVU-TZ + HAS-HCR
HVU + HAS-HCR
a)
1 / 2009
Authority/No.
IBMB Braunschweig
UB 3332/0881-2-CM
& supplement letter 13184/2006
Warringtonfire
WF-Report No 166402
MFPA Leipzig
PB III/08-354
IBMB Braunschweig
UB 3027/0274-4
& supplement letter 133/00-NauWarringtonfire
WF-Report No 166402
IBMB Braunschweig
UB 3357/0550-2
Warringtonfire
WF-Report No 166402
IBMB Braunschweig
UB 3333/0891-2
Warringtonfire
WF-Report No 166402
77
Mechanical anchoring
systems
78
1 / 2009
Mechanical anchoring
systems
1 / 2009
79
HDA-P
HDA-PR
HDA-PF
Anchor for presetting
HDA-T
HDA-TR
HDA-TF
Anchor for
through-fasting
Concrete
Tensile
zone
Nuclear
power plant
approval
European
Technical
Approval
Performance
of a headed
stud
CE
conformity
Small edge
distance
and spacing
Fire
resistance
Fatigue
Shock
Seismic
Corrosion
resistance
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
ICC-ES report
Shockproof fastenings in civil
defence installations
Nuclear power plants
Dynamic loads
Fire test report
Assessment report (fire)
Authority / Laboratory
CSTB, Paris
ICC evaluation service
DIBt, Berlin
DIBt, Berlin
IBMB, Braunschweig
warringtonfire
Z-21.1-1696 / 2008-09-01
Z-21.1-1693 / 2007-10-25
UB 3039/8151-CM / 2001-01-31
WF 166402 / 2007-10-26
a) All data for HDA-P(R) and HDA-T(R) given in this section according ETA-99/0009, issue 2008-03-25.
Sherardized versions HDA-PF and HDA-TF anchors are not covered by the approvals.
80
1 / 2009
M10
M12
M16
M20
Cracked concrete
a)
M10
M12
M16
M20 a)
Tensile NRu,m
HDA-P(F), HDA-T(F) b)
[kN]
48,7
70,9
133,3
203,2
29,4
41,1
88,1
111,6
HDA-PR, HDA-TR
[kN]
48,7
70,9
133,3
203,2
29,4
41,1
88,1
111,6
HDA-P, HDA-PF b)
[kN]
23,3
31,7
65,6
97,4
23,3
31,7
65,6
97,4
HDA-PR
[kN]
24,3
36,0
66,7
24,3
36,0
66,7
[kN]
68,8
84,7
148,2
216,9
68,8
84,7
148,2
216,9
Shear VRu,m
HDA-T, HDA-TF
b) c)
c)
HDA-TR
[kN]
75,1
92,1
160,9
75,1
92,1
160,9
a) HDA M20: only a galvanized 5m version is available
b) HDA-PF and HDA-TF anchors are not covered by ETA-99/0009
c) Values are valid for minimum thickness of the base plate tfix,min without use of centering washer (see page 88)
Characteristic resistance
Non-cracked concrete
Anchor size
M10
M12
M16
M20
Cracked concrete
a)
M10
M12
M16
M20 a)
Tensile NRk
HDA-P(F), HDA-T(F) b)
[kN]
46
67
126
192
25
35
75
95
HDA-PR, HDA-TR
[kN]
46
67
126
25
35
75
M10
M12
M16
M20 a)
22
30
62
92
23
34
63
Shear VRk
HDA-P, HDA-PF b)
[kN]
HDA-PR
for tfix
HDA-T, HDA-TF b)
[mm]
[mm]
10 15
<15 20
10
<15
15
<20
20
50
[kN]
65 c)
80 c)
80
100 140 c) 140 155 170 190 205 c) 205 235 250
[mm]
[mm]
10 15 10 15 20 30
<15 20 <15 <20 <30 50
65
15 20 25 30 35 20 25 40 55
<20 <25 <30 <35 60 <25 <40 <55 100
20
<25
25
<30
30
<35
35
60
HDA-TR
[kN]
71 c) 71 87 c) 87 94 109 152 c)
a) HDA M20: only a galvanized 5m version is available
b) HDA-PF and HDA-TF anchors are not covered by ETA-99/0009
c) With use of centering washer (t = 5 mm) only
152
158
170
for tfix
1 / 2009
81
Design resistance
Non-cracked concrete
Anchor size
M10
M12
M16
M20
Cracked concrete
a)
M10
M12
M16
M20 a)
Tensile NRd
HDA-P(F), HDA-T(F) b)
[kN]
30,7
44,7
84,0
128,0
16,7
23,3
50,0
63,3
HDA-PR, HDA-TR
[kN]
28,8
41,9
78,8
16,7
23,3
50,0
M10
M12
M16
M20 a)
17,6
24,0
49,6
73,6
17,3
25,6
47,4
Shear VRd
HDA-P, HDA-PF b)
[kN]
HDA-PR
[mm]
[mm]
10 15
<15 20
10
<15
15
<20
20
50
15 20 25 30 35 20 25 40 55
<20 <25 <30 <35 60 <25 <40 <55 100
[kN]
43 c)
53 c)
53
67
93 c)
[mm]
[mm]
10 15 10 15 20 30
<15 20 <15 <20 <30 50
20
<25
25
<30
30
<35
35
60
HDA-TR
[kN]
53 c) 53 65 c) 65 71 82
a) HDA M20: only a galvanized 5m version is available
b) HDA-PF and HDA-TF anchors are not covered by ETA-99/0009
c) With use of centering washer (t = 5 mm) only
114 c)
114
119
128
for tfix
HDA-T, HDA-TF b)
for tfix
43
93
Recommended loads
Non-cracked concrete
Anchor size
M10
M12
M16
M20
Cracked concrete
a)
M10
M12
M16
M20
a)
Tensile NRec b)
HDA-P(F), HDA-T(F) c)
[kN]
21,9
31,9
60,0
91,4
11,9
16,7
35,7
45,2
HDA-PR, HDA-TR
[kN]
20,5
29,9
56,3
11,9
16,7
35,7
M10
M12
M16
M20 a)
12,6
17,1
35,4
52,6
12,3
18,2
33,8
Shear VRec b)
HDA-P, HDA-PF c)
[kN]
HDA-PR
for tfix
HDA-T, HDA-TF c)
for tfix
a)
b)
c)
d)
82
[mm]
[mm]
10 15
<15 20
10
<15
15
<20
20
50
15 20 25 30 35 20 25 40 55
<20 <25 <30 <35 60 <25 <40 <55 100
[kN]
31 d)
38 d)
38
48
67 d)
[mm]
[mm]
10 15 10 15 20 30
<15 20 <15 <20 <30 50
31
20
<25
67
25
<30
74
81
30
<35
90
35
60
98 d)
98
112 119
-
HDA-TR
[kN]
38 d) 38 47 d) 47 50 59 82 d)
82
85
91
HDA M20: only a galvanized 5m version is available
With overall partial safety factor for action F = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
HDA-PF and HDA-TF anchors are not covered by ETA-99/0009
With use of centering washer (t = 5 mm) only
1 / 2009
Materials
Mechanical properties of HDA
Anchor size
M10
HDA-P(F), HDA-T(F)
M12
M16
M20 a)
HDA-PR, HDA-TR
M10
M12
M16
Anchor bolt
Nominal tensile strength fuk [N/mm]
800
800
800
800
800
800
800
Yield strength fyk
[N/mm]
640
640
640
640
600
600
600
Stressed cross-section As [mm]
58,0
84,3
157
245
58,0
84,3
157
Moment of resistance Wel [mm]
62,3
109,2
277,5
540,9
62,3
109,2
277,5
Characteristic bending
[Nm]
60
105
266
519
60
105
266
resistance without sleeve
M0Rk,s b)
Anchor sleeve
Nominal tensile strength fuk [N/mm]
850
850
700
550
850
850
700
Yield strength fyk
[N/mm]
600
600
600
450
600
600
600
a) HDA M20: only a galvanized 5m version is available
b) The recommended bending moment of the HDA anchor bolt may be calculated from Mrec = MRd,s / F =
MRk,s / (Ms . F) = = (1,2 . Wel . fuk) / (Ms . F) , where the partial safety factor for bolts of grade 8.8 is MS = 1,25,
for A4-80 equal to 1,33 and the partial safety factor for action may be taken as F = 1,4. In case of HDA-T/TR/TF
the bending capacity of the sleeve is neglected, only the capacity of the bolt is taken into account.
Material quality
Part
Material
HDA-P / HDA-T (Carbon steel version)
Sleeve:
Machined steel with brazed tungsten carbide tips, galvanised to min. 5 m
Cold formed steel, grade 8.8, galvanised to min. 5 m
Bolt M10 - M16:
Cone machined, rod grade 8.8, galvanised to min. 5 m
Bolt M20:
HDA-PR / HDA-TR (Stainless steel version)
Sleeve:
Machined stainless steel with brazed tungsten carbide tips
Bolt M10 - M16:
Cone/rod: machined stainless steel
HDA-PF / HDA-TF (Sherardized version)
Sleeve:
Machined steel with brazed tungsten carbide tips, shearadized
Bolt M10 - M16:
Cold formed steel, grade 8.8, shearadized
Anchor dimensions
HDA-P / HDA-PR / HDA-PF
dS
dB
lS
SW
lB
HDA-T / HDA-TR / HDA-TF
dS
lS
lB
1 / 2009
dB
SW
83
Dimensions of HDA
Anchor size
lB
dB
[mm]
[mm]
ls
ls
[mm]
[mm]
100
120
dS
[mm]
19
21
29
35
dw
Sw
[mm]
[mm]
27,5
17
33,5
19
45,5
24
50
30
125
155
125
175
190
230
190
250
250
300
250
350
Setting
Drilling
The stop drill is required for drilling in order to achieve the correct hole depth.
Anchor
HDA-P/ PF/ PR M10x100/20
HDA-T/ TF/ TR M10x100/20
HDA-P/ PF/ PR M12*125/30
HDA-P/ PF/ PR M12*125/50
HDA-T/ TF/ TR M12*125/30
HDA-T/ TF/ TR M12*125/50
Setting
Drilling hammer
Setting tool
The setting system (tool and setting tool) is required for transferring the specific energy for the undercutting
process.
84
1 / 2009
HDA-P/T20-M10*100/20
HDA-P/T 22-M12*125/30
HDA-P/T 22-M12*125/50
TE 76 b)
TE 76-ATC b)
TE 70 b)
TE 70-ATC b)
b)
TE 75
TE 50
TE 40
TE 40 AVR
TE 35
a)
TE 24
TE 25 a)
TE 56 b)
TE 56-ATC b)
3,5 - 4,9
6,5 - 7,5
3,5 - 4,9
250 - 555
480 - 500
250 - 555
TE-Y-HDA-ST 22 M12
6,5 - 7,5
480 - 500
HDA-P/T 37-M20*250/50
HDA-P/T 37-M20*250/100
a) 1st gear
b) max. impact energy
TE-Y-HDA-ST 30 M16
8,0 - 11,0
250 - 360
TE-Y-HDA-ST 37 M20
8,3 - 11,0
280 - 360
HDA-PR/TR 22-M12*125/30
HDA-PR/TR 22-M12*125/50
TE 76 b)
TE 76-ATC b)
TE 70 b)
TE 70-ATC b)
TE 75 b)
TE 40
TE 40 AVR
TE 56 b)
TE 56-ATC b)
TE 35
TE 50
TE 24 a)
TE 25 a)
HDA-PR/TR 30-M16*190/40
HDA-PR/TR 30-M16*190/60
a) 1st gear
b) max. impact energy
TE-Y-HDA-ST 22 M12
6,5 - 7,5
480 - 500
TE-Y-HDA-ST 30 M16
8,0 - 11,0
250 - 360
Setting tool
TE 76 b)
TE 76-ATC b)
TE 70 b)
TE 70-ATC b)
TE 75 b)
TE 56 b)
TE 56-ATC b)
TE 50
TE 40
TE 40 AVR
TE 35
TE 24 a)
TE 25 a)
Setting tool
Single
Speed
impact
under load
energy [J]
[1/min]
TE-C-HDA-ST 20 M10
TE-Y-HDA-ST 20 M10
TE-C-HDA-ST 22 M12
HDA-P/T 30-M16*190/40
HDA-P/T 30-M16*190/60
HDA-PR/TR20-M10*100/20
Setting tool
Single
Speed
impact under load
energy [J]
[1/min]
HDA-PF/TF 20-M10*100/20
TE-C-HDA-ST 20 M10
3,5 4,0
610 - 630
HDA-PF/TF 22-M12*125/30
HDA-PF/TF 22-M12*125/50
TE-C-HDA-ST 22 M12
3,5 4,0
610 - 630
TE-Y-HDA-ST 30 M16
8,0 - 11,0
250 - 360
HDA-PF/TF 30-M16*190/40
HDA-PF/TF 30-M16*190/60
a) 1st gear
b) max. impact energy
1 / 2009
85
Setting instruction
HDA-P, HDA-PR, HDA-PF
86
1 / 2009
For detailed information on installation see instruction for use given with the package of the product.
Setting details
hS
HDA-P / HDA-PR / HDA-PF
df
tfix
hef
h1
hmin
hS
Marking
df
hef
tfix
h1
hmin
1 / 2009
87
Anchor size
Head marking
Nominal drill bit
diameter
Cutting diameter
of drill bit
Depth of drill hole a)
Anchorage depth
Sleeve recess
Torque moment
For HDA-P/-PF/-PR
Clearance hole
Minimum base
material thickness
Fixture thickness
[mm]
20
22
30
37
dcut,min
dcut,max
h1
hef
hs,min
hs,max
Tinst
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[Nm]
20,10
20,55
107
100
2
6
50
22,10
22,55
133
125
2
7
80
30,10
30,55
203
190
2
8
120
37,15
37,70
266
250
2
8
300
df
[mm]
12
14
18
22
hmin
[mm]
180
200
270
350
tfix,min
tfix,max
[mm]
[mm]
0
20
0
30
0
50
40
0
60
50
100
For HDA-T/-TF/-TR
Clearance hole
df
[mm]
21
23
32
40
Minimum base
hmin
[mm] 200-tfix
230-tfix
250-tfix
310-tfix
330-tfix
400-tfix
450-tfix
material thickness
Min. fixture thickness
-Tension load only!
tfix,min [mm]
10
10
15
20
50
-Shear load - without
t
[mm]
15
15
20
25
50
use of centering washer fix,min
-Shear load - with
b)
t
[mm]
10
10
15
20
use of centering washer fix,min
Max. fixture thickness
tfix,max [mm]
20
30
50
40
60
50
100
a) use specified stop drill bit
b) with use of centering washer a reduction of tfix,min is possible for shear loading, details see ETA-99/0009
88
1 / 2009
Setting parameters
Anchor size
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
Critical edge distance
for splitting failure
Critical spacing for
concrete cone failure
Critical edge distance
for concrete cone
failure
smin
[mm]
cmin
[mm]
80
100
150
200
scr,sp
[mm]
300
375
570
750
ccr,sp
[mm]
150
190
285
375
scr,N
[mm]
300
375
570
750
ccr,N
[mm]
150
190
285
375
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked
concrete only the critical spacing and critical edge distance for concrete cone failure are decisive.
1 / 2009
89
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
= N0Rd,p fB
NRd,c
HDA-P(F), HDA-T(F)
[kN]
M10
M12
M16
M20 a)
30,7
44,7
84,0
128,0
41,9
78,8
[kN]
HDA-PR, HDA-TR
28,8
HDA M20: only a galvanized 5m version is available
a)
N
a)
b)
M10
M12
M16
Cracked concrete
M20**
[kN]
Design pull-out resistance is not decisive in non-cracked concrete
HDA M20: only a galvanized 5m version is available
Rd,p
M10
M12
M16
M20 b)
25
35
75
95
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
Non-cracked concrete
M20**
M10
M12
M16
M20 b)
[kN]
58,1
81,2
152,2
229,7
Splitting resistance must only be considered for non-cracked concrete
HDA M20: only a galvanized 5m version is available
41,5
58,0
108,7
164,0
Anchor size
0
N
a)
b)
Cracked concrete
M10
M12
M16
Rd,c
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
90
C 45/55
C 50/60
1,48
1,55
1 / 2009
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
2/3
2,2
2,4
2,6
2,8
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
Influence of reinforcement
Anchor size
M8
a)
M10
a)
M12
M16
M20
M24
a)
0,8
0,85
0,9
1
1
1
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
1 / 2009
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
91
M12
M16
M20 a)
[kN]
12,6
17,1
35,4
52,6
[kN]
12,3
18,2
33,8
[kN]
31,0
38,1
66,7
97,6
Anchor size
HDA-P, HDA-PF
VRd,s
HDA-PR
HDA-T, HDA-TF
b)
b)
HDA-TR
[kN]
38,1
46,7
81,6
a) HDA M20: only a galvanized 5m version is available
b) Values are valid for minimum thickness of the base plate tfix,min. For characteristic resistance to shear loads with
thicker base plates see ETA-99/0009 or use PROFIS software.
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Anchor size
M10
M16
M20*
M10
M12
M16
M20 a)
202,9
306,2
55,3
77,3
144,9
218,7
M12
V0Rd,cp
[kN]
77,5
108,3
a) HDA M20: only a galvanized 5m version is available
Cracked concrete
M12
M16
M20**
M10
M12
M16
M20 b)
[mm]
80
100
150
200
80
100
150
200
[kN]
8,5
12,8
26,1
45,0
6,1
9,2
18,6
32,1
Anchor size
cmin
V
Rd,c
Cracked concrete
a) For anchor groups with more than two anchors only the anchors close to the edge must be considered.
b) HDA M20: only a galvanized 5m version is available
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
92
1 / 2009
M8
0,8
M10
a)
0,85
M12
a)
0,9
M16
M20
M24
a)
This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
93
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-99/0009, issue 2008-03-25.
All data applies to concrete C 20/25 fck,cube =25 N/mm.
HDA-PF and HDA-TF anchors are not covered by the approval. For HDA-T and HDA-TR anchors the resistance to
shear loads is calculated for the minimum thickness of the base plate given in chapter setting details page 87.
Design resistance
Single anchor, no edge effects, shear without lever arm
Non-cracked concrete
Anchor size
Min. base material thickness hmin [mm]
HDA-T: Min. fixture thickness tfix [mm]
Tensile NRd
Cracked concrete
M10
180
15
M12
200
15
M16
270
20
M20
350
25
M10
180
15
M12
200
15
M16
270
20
M20
350
25
HDA-P(F), HDA-T(F)
[kN]
30,7
44,7
84,0
128,0
16,7
23,3
50,0
63,3
HDA-PR, HDA-TR
Shear VRd
HDA-P, HDA-PF
HDA-PR
HDA-T, HDA-TF
HDA-TR
[kN]
28,8
41,9
78,8
16,7
23,3
50,0
[kN]
[kN]
[kN]
[kN]
17,6
17,3
43,3
53,4
24,0
25,6
53,3
65,4
49,6
47,4
93,3
114,3
73,6
136,7
-
17,6
17,3
43,3
53,4
24,0
25,6
53,3
65,4
49,6
47,4
93,3
114,3
73,6
136,7
-
Single anchor, min. edge distance (c = cmin), shear without lever arm
Non-cracked concrete
Cracked concrete
Anchor size
Min. base material thickness hmin [mm]
HDA-T: Min. fixture thickness tfix [mm]
Min. edge distance cmin [mm]
Tensile NRd
HDA-P(F), HDA-T(F)
HDA-PR, HDA-TR
Shear VRd
HDA-P, HDA-PF
HDA-PR
HDA-T, HDA-TF
HDA-TR
M10
180
15
80
M12
200
15
100
M16
270
20
150
M20
350
25
200
M10
180
15
80
M12
200
15
100
M16
270
20
150
M20
350
25
200
[kN]
25,5
35,9
66,4
100,9
16,7
23,3
47,4
63,3
[kN]
8,5
12,8
26,1
45,0
6,1
9,2
18,6
32,1
Double anchor, no edge effects, min. spacing (s = smin), shear without lever arm
(load values are valid for one anchor)
Non-cracked concrete
Cracked concrete
Anchor size
Min. base material thickness hmin [mm]
HDA-T: Min. fixture thickness tfix [mm]
Min. spacing smin [mm]
Tensile NRd
HDA-P(F), HDA-T(F)
HDA-PR, HDA-TR
Shear VRd
HDA-P, HDA-PF
HDA-PR
HDA-T, HDA-TF
HDA-TR
94
M10
180
15
100
M12
200
15
125
M16
270
20
190
M20
350
25
250
M10
180
15
100
M12
200
15
125
M16
270
20
190
M20
350
25
250
[kN]
25,8
36,0
67,6
102,1
16,7
23,3
48,3
63,3
[kN]
[kN]
[kN]
[kN]
17,6
17,3
43,3
51,6
24,0
25,6
53,3
65,4
49,6
47,4
93,3
114,3
73,6
136,7
-
17,6
17,3
36,9
36,9
24,0
25,6
51,4
51,4
49,6
47,4
93,3
96,6
73,6
136,7
1 / 2009
Recommended loads
Single anchor, no edge effects, shear without lever arm
Non-cracked concrete
Anchor size
in. base material thickness hmin [mm]
HDA-T: Min. fixture thickness tfix [mm]
Tensile Nrec
M10
180
15
M12
200
15
M16
270
20
M20
350
25
Cracked concrete
M10
180
15
M12
200
15
M16
270
20
M20
350
25
HDA-P(F), HDA-T(F)
[kN]
21,9
31,9
60
91,4
11,9
16,6
35,7
45,2
HDA-PR, HDA-TR
Shear Vrec
HDA-P, HDA-PF
HDA-PR
HDA-T, HDA-TF
HDA-TR
[kN]
20,6
29,9
56,3
11,9
16,6
35,7
[kN]
[kN]
[kN]
[kN]
12,6
12,4
30,9
38,1
17,1
18,3
38,1
46,7
35,4
33,9
66,6
81,6
52,6
97,6
-
12,6
12,4
30,9
38,1
17,1
18,3
38,1
46,7
35,4
33,9
66,6
81,6
52,6
97,6
-
Single anchor, min. edge distance (c = cmin), shear without lever arm
Non-cracked concrete
Cracked concrete
Anchor size
Min. base material thickness hmin [mm]
HDA-T: Min. fixture thickness tfix [mm]
Min. edge distance cmin [mm]
Tensile Nrec
HDA-P(F), HDA-T(F)
HDA-PR, HDA-TR
Shear Vrec
HDA-P, HDA-PF
HDA-PR
HDA-T, HDA-TF
HDA-TR
M10
180
15
80
M12
200
15
100
M16
270
20
150
M20
350
25
200
M10
180
15
80
M12
200
15
100
M16
270
20
150
M20
350
25
200
[kN]
18,2
25,7
47,4
72,1
11,9
16,7
33,9
45,2
[kN]
6,1
9,2
18,6
32,1
4,4
6,5
13,3
22,9
Double anchor, no edge effects, min. spacing (s = smin), shear without lever arm
(load values are valid for one anchor)
Non-cracked concrete
Cracked concrete
Anchor size
Min. base material thickness hmin [mm]
HDA-T: Min. fixture thickness tfix [mm]
Min. spacing smin [mm]
Tensile Nrec
HDA-P(F), HDA-T(F)
HDA-PR, HDA-TR
Shear Vrec
HDA-P, HDA-PF
HDA-PR
HDA-T, HDA-TF
HDA-TR
M10
180
15
100
M12
200
15
125
M16
270
20
190
M20
350
25
250
M10
180
15
100
M12
200
15
125
M16
270
20
190
M20
350
25
250
[kN]
18,4
25,7
48,3
72,9
11,9
16,6
34,5
45,2
[kN]
[kN]
[kN]
[kN]
12,6
12,4
30,9
36,9
17,1
18,3
38,1
46,7
35,4
33,9
66,6
81,6
52,6
97,6
-
12,6
12,4
26,4
26,4
17,1
18,3
36,7
36,7
35,4
33,9
66,6
69,0
52,6
97,6
-
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
95
HSL-3
Heavy duty anchor
Benefits
- suitable for non-cracked and
cracked concrete C 20/25 to
C 50/60
- high loading capacity
- force-controlled expansion
- reliable pull-down of the part
fastened
- no rotation in hole when
tightening bolt
HSL-3
Bolt version
HSL-3-G
Threaded rod
version
HSL-3-B
Safety cap
version
HSL-3-SH
Hexagonal
socked head
screws
HSL-3-SK
Countersunk
version
Concrete
Tensile
zone
Fire
resistance
Fatigue
Shock
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
ICC-ES report
Shockproof fastenings in civil
defence installations
Dynamic loads
Fire test report
Assessment report (fire)
Authority / Laboratory
CSTB, Paris
ICC evaluation service
Bundesamt fr
Bevlkerungsschutz, Bern
Construction research laboratory,
University of Dortmund
IBMB, Braunschweig
warringtonfire
96
1 / 2009
HSL-3
Heavy duty anchor
Cracked concrete
M8
M8
[kN]
31,1
39,2
47,9
66,9
122,9
15,9
21,2
34,2
47,8
66,8
HSL-3, HSL-3-B,
HSL-3-SKa), HSL-3-SH a)
[kN]
43,0
68,0
95,8
40,0
56,0
68,4
95,6
133,6 175,6
HSL-3-Gb)
[kN]
36,1
48,1
75,1
118,5 187,0
36,1
48,1
68,4
95,6
133,6
Tensile NRu,m
93,5
87,8
Shear VRu,m
Characteristic resistance
Non-cracked concrete
Anchor size
Cracked concrete
M8
M8
[kN]
23,4
29,5
36,1
50,4
92,6
12,0
16,0
25,8
36,0
50,3
HSL-3, HSL-3-B,
HSL-3-SKa), HSL-3-SH a)
[kN]
31,1
49,2
71,7
30,1
42,2
51,5
72,0
100,6 132,3
HSL-3-Gb)
[kN]
26,1
34,8
54,3
85,7
26,1
34,8
51,5
72,0
100,6
Tensile NRk
70,4
66,1
Shear VRk
140,9
Design resistance
Non-cracked concrete
Anchor size
Cracked concrete
M8
M8
[kN]
15,6
19,7
24,0
33,6
47,0
61,7
6,7
10,7
17,2
24,0
33,5
44,1
HSL-3, HSL-3-B,
HSL-3-SKa), HSL-3-SH a)
[kN]
24,9
39,4
48,1
67,2
93,9
123,5
20,1
28,1
34,3
48,0
67,1
88,2
HSL-3-Gb)
[kN]
20,9
27,8
43,4
67,2
93,9
20,1
27,8
34,3
48,0
67,1
Tensile NRd
Shear VRd
Recommended loads
Non-cracked concrete
Anchor size
Cracked concrete
M8
M8
[kN]
11,2
14,1
17,2
24,0
33,5
44,1
4,8
7,6
12,3
17,1
24,0
31,5
HSL-3, HSL-3-B,
[kN]
HSL-3-SKa), HSL-3-SHa)
17,8
28,1
34,3
48,0
67,1
88,2
14,3
20,1
24,5
34,3
47,9
63,0
Tensile Nrec
Shear Vrec
c)
c)
HSL-3-Gb)
[kN]
14,9 19,9 31,0 48,0 67,1
14,3 19,9 24,5 34,3 47,9
a) HSL-3-SK and HSL-3-SH is only available up to M12
b) HSL-3-G is only available up to M20
c) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
97
HSL-3
Heavy duty anchor
Materials
Mechanical properties of HSL-3, HSL-3-G, HSL-3-B, HSL-3-SH, HSL-3-SK
Anchor size
Nominal tensile strength fuk
Yield strength fyk
Stressed cross-section As
Moment of resistance W
Design bending resistance
without sleeve MRd,s
[N/mm]
[N/mm]
[mm]
[mm]
M8
800
640
36,6
31,3
M10
800
640
58,0
62,5
M12
800
640
84,3
109,4
M16
800
640
157
277,1
M20
830
640
245
540,6
M24
830
640
353
935,4
[Nm]
24,0
48,0
84,0
212,8
415,2
718,4
Material quality
Part
Bolt, threaded rod
Material
steel grade 8.8 according ISO 898-1, galvanised to min. 5 m
Anchor dimensions
Dimensions of HSL-3, HSL-3-G, HSL-3-B, HSL-3-SH, HSL-3-SK
Anchor
version
HSL-3
HSL-3-G
HSL-3
HSL-3-G
HSL-3-B
Thread
size
tfix [mm]
ds
[mm]
l1
[mm]
l2
[mm]
l3
[mm]
min
l4 [mm]
max
p
[mm]
min
max
M8
200
11,9
12
32
15,2
19
214
M10
200
14,8
14
36
17,2
23
218
M12
200
17,6
17
40
20
28
223
M16
10
200
23,6
20
54,4
24,4
34,5
224,5
M20
10
200
27,6
20
57
31,5
51
241
HSL-3
HSL-3-B
M24
10
200
31,6
22
65
39
57
247
HSL-3-SH
M8
11,9
12
32
15,2
19
M10
20
14,8
14
36
17,2
38
M12
25
17,6
17
40
20
48
HSL-3-SK
98
11,9
12
32
15,2
M10
M8
10
20
20
14,8
14
36
17,2
18,2
32,2
28,2
M12
25
17,6
17
40
20
40
1 / 2009
HSL-3
Heavy duty anchor
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
M8
M10
M12
M16
M20
TE2 TE16
TE40 TE70
hammer, torque wrench, blow out pump
M24
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
Setting details: depth of drill hole h1 and effective anchorage depth hef
M8
M10
M12
M16
M20
M24
do
[mm]
12
15
18
24
28
32
dcut
[mm]
12,5
15,5
18,5
24,55
28,55
32,7
h1
[mm]
80
90
105
125
155
180
df
[mm]
14
17
20
26
31
35
hef
[Nm]
60
70
80
100
125
150
Torque moment
Tinst
[mm]
25
50
80
120
200
250
Width across
SW
[mm]
13
17
19
24
30
36
1 / 2009
99
HSL-3
Heavy duty anchor
M8
M10
M12
M16
M20
do
[mm]
12
15
18
24
28
dcut
[mm]
12,5
15,5
18,5
24,55
28,55
h1
[mm]
80
90
105
125
155
df
[mm]
14
17
20
26
31
hef
[mm]
60
70
80
100
125
Torque moment
Tinst
[Nm]
20
35
60
80
160
Width across
SW
[mm]
13
17
19
24
30
M12
M16
M20
M24
do
[mm]
18
24
28
32
dcut
[mm]
18,5
24,55
28,55
32,7
h1
[mm]
105
125
155
180
df
[mm]
20
26
31
35
hef
[mm]
80
100
125
150
[mm]
24
30
36
41
M8
M10
M12
Width across
SW
The torque moment is controlled by the safety cap
do
[mm]
12
15
18
dcut
[mm]
12,5
15,5
18,5
h1
[mm]
85
95
110
df
[mm]
14
17
20
hef
[mm]
60
70
80
Torque moment
Tinst
[Nm]
25
35
60
Width across
SW
[mm]
10
100
1 / 2009
HSL-3
Heavy duty anchor
M8
M10
M12
do
[mm]
12
15
18
dcut
[mm]
12,5
15,5
18,5
h1
[mm]
80
90
105
df
[mm]
14
17
20
dh =
[mm]
22,5
25,5
32,9
hef
[mm]
60
70
80
Torque moment
Tinst
[Nm]
25
50
80
SW
[mm]
Setting parameters
Anchor size
Minimum base
material thickness
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
Critical edge distance
for splitting failure
Critical spacing for
concrete cone failure
Critical edge distance
for concrete cone
failure
M8
M10
M12
M16
M20
M24
hmin
[mm]
120
140
160
200
250
300
smin
for c
cmin
for s
[mm]
[mm]
[mm]
[mm]
60
100
60
100
70
100
70
160
80
160
80
240
100
240
100
240
125
300
150
300
150
300
150
300
scr,sp
[mm]
230
270
300
380
480
570
ccr,sp
[mm]
115
135
150
190
240
285
scr,N
[mm]
180
210
240
300
375
450
ccr,N
[mm]
90
105
120
150
187,5
225
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked
concrete only the critical spacing and critical edge distance for concrete cone failure are decisive.
1 / 2009
101
HSL-3
Heavy duty anchor
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
[kN]
M8
19,5
M10
30,9
M12
44,9
M16
83,7
M20
130,7
M24
188,3
Design pull-out resistance NRd,p = N0Rd,p fB (only M8, M10 in cracked concrete)
Non-cracked concrete
Anchor size
0
Rd,p
M8
[kN]
Cracked concrete
M8
6,7
10,7
No pull-out failure
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
Non-cracked concrete
Anchor size
M8
Cracked concrete
M8
N Rd,c
[kN]
15,6 19,7 24,0 33,6 47,0 61,7 11,2 14,1 17,2 24,0 33,5 44,1
a) Splitting resistance must only be considered for non-cracked concrete
102
1 / 2009
HSL-3
Heavy duty anchor
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
2/3
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
Influence of reinforcement
Anchor size
M8
a)
M10
a)
M12
M16
M20
M24
a)
0,8
0,85
0,9
1
1
1
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
1 / 2009
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
103
HSL-3
Heavy duty anchor
M8
M10
HSL-3, HSL-3-B,
24,9
39,4
a)
a) [kN]
VRd,s HSL-3-SK , HSL-3-SH
HSL-3-G
[kN]
20,9
27,8
a) HSL-3-SK and HSL-3-SH is only available up to M12
M12
M16
M20
M24
57,4
80,9
113,5
141,9
43,4
68,6
113,5
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Anchor size
V
[kN]
Rd,cp
Cracked concrete
M8
M8
28,1
39,4
20,1
28,1
48,1
67,2
93,9
123,5
34,3
48,0
67,1
88,2
M8
Cracked concrete
M8
V0Rd,c
[kN]
4,7
6,5
8,6 13,7 20,9 29,7 3,3
a) For anchor groups only the anchors close to the edge must be considered.
6,1
9,8
15,0
21,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
Influence of reinforcement
Anchor size
M8
a)
M10
a)
M12
M16
M20
M24
a)
0,8
0,85
0,9
1
1
1
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
104
1 / 2009
HSL-3
Heavy duty anchor
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-02/0042, issue 2008-01-10.
All data applies to concrete C 20/25 fck,cube =25 N/mm. HSL-3-SK and HSL-3-SH is only available up to M12.
1 / 2009
105
HSL-3
Heavy duty anchor
Design resistance
Single anchor, no edge effects
Non-cracked concrete
Anchor size
M8
Min. base material thickness hmin [mm] 120
Tensile NRd
HSL-3, HSL-3-B,
HSL-3-S), HSL-3-SH
[kN] 15,6
HSL-3-G
Shear VRd, without lever arm
HSL-3, HSL-3-B,
[kN] 24,9
HSL-3-SK , HSL-3-SH
HSL-3-G
[kN] 20,9
Cracked concrete
M8
120
19,7
24,0
33,6
47,0
61,7
6,7
10,7
17,2
24,0
33,5
44,1
39,4
48,1
67,2
93,9
123,5
20,1
28,1
34,3
48,0
67,1
88,2
27,8
43,4
67,2
93,9
20,1
27,8
34,3
48,0
67,1
M8
120
60
12,8
15,9
22,0
33,9
40,4
6,7
10,5
12,9
18,0
28,4
33,1
6,5
8,6
13,7
27,5
29,7
3,3
4,6
6,1
9,8
19,7
21,2
Cracked concrete
106
Cracked concrete
M8
120
60
12,4
15,2
21,2
29,6
39,0
6,7
9,4
11,4
16,0
22,4
29,4
26,2
32,1
44,8
62,6
82,3
13,4
18,7
22,9
32,0
44,7
58,8
1 / 2009
HSL-3
Heavy duty anchor
Recommended loads
Single anchor, no edge effects
Non-cracked concrete
Anchor size
M8
Min. base material thickness hmin [mm] 120
Tensile Nrec
HSL-3, HSL-3-B,
HSL-3-SK, HSL-3-SH [kN] 11,2
HSL-3-G
Shear Vrec, without lever arm
HSL-3, HSL-3-B,
[kN] 17,8
HSL-3-SK, HSL-3-SH
HSL-3-G
[kN] 14,9
Cracked concrete
M8
120
14,1
17,2
24,0
33,5
44,1
4,8
7,6
12,3
17,1
24,0
31,5
28,1
34,3
48,0
67,1
88,2
14,3
20,1
24,5
34,3
47,9
63,0
19,9
31,0
48,0
67,1
14,3
19,9
24,5
34,3
47,9
M8
120
60
Cracked concrete
9,1
11,3
15,7
24,2
28,9
4,8
7,5
9,2
12,9
20,3
23,6
4,6
6,1
9,8
15,0
21,2
2,4
3,3
4,4
7,0
10,7
15,2
Cracked concrete
M8
120
60
8,9
10,9
15,2
21,1
27,8
4,8
6,7
8,2
11,4
16,0
21,0
18,7
22,9
32,0
44,7
58,8
9,6
13,4
16,4
22,9
31,9
42,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
107
Benefits
Bolt version
HSC-A Carbon Steel
version
HSC-AR Stainless
steel version
Concrete
Tensile
zone
Small edge
distance
and spacing
Fire
resistance
Shock
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
Authority / Laboratory
European technical approval a)
CSTB, Paris
Shockproof fastenings in civil
Bundesamt fr Zivilschutz, Bern
defence installations
Fire test report
IBMB, Braunschweig
Assessment report (fire)
warringtonfire
a) All data given in this section according ETA-02/0027 issue 2008-09-20
108
1 / 2009
Cracked concrete
M12x60
Tensile NRu,m
HSC-A
HSC-AR
[kN]
16,6
16,6
23,3
30,6
13,3
13,3
18,6
24,5
HSC-A
[kN]
19,0
19,0
30,2
43,8
19,0
19,0
30,2
43,8
HSC-AR
[kN]
16,6
16,6
26,4
38,4
16,6
16,6
26,4
38,4
Shear VRu,m
Characteristic resistance
Non-cracked concrete
Anchor size
Cracked concrete
M12x60
Tensile NRk
HSC-A
[kN]
12,8
12,8
17,8
23,4
9,1
9,1
12,7
16,7
HSC-AR
[kN]
12,8
12,8
17,8
23,4
9,1
9,1
12,7
16,7
HSC-A
[kN]
14,6
23,2
14,6
33,7
14,6
18,2
14,6
33,5
HSC-AR
[kN]
12,8
20,3
12,8
29,5
12,8
18,2
12,8
29,5
Shear VRk
Design resistance
Non-cracked concrete
Anchor size
Cracked concrete
M12x60
Tensile NRd
HSC-A
[kN]
8,5
8,5
11,9
15,6
6,1
6,1
8,5
11,2
HSC-AR
[kN]
8,5
8,5
11,9
15,6
6,1
6,1
8,5
11,2
HSC-A
[kN]
11,7
17,0
11,7
27,0
11,7
12,1
11,7
22,3
HSC-AR
[kN]
8,2
13,0
8,2
18,9
8,2
12,1
8,2
18,9
Shear VRd
Recommended loads
Non-cracked concrete
Anchor size
Tensile Nrec
Cracked concrete
M12x60
a)
[kN]
6,1
6,1
8,5
11,2
4,3
4,3
6,1
8,0
[kN]
6,1
6,1
8,5
11,2
4,3
4,3
6,1
8,0
HSC-A
[kN]
8,3
12,1
8,3
19,3
8,3
8,7
8,3
15,9
HSC-AR
[kN]
5,9
9,3
5,9
13,5
5,9
8,7
5,9
13,5
HSC-A
HSC-AR
Shear Vrec
a)
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
109
Materials
Mechanical properties
Anchor size
Nominal tensile strength fuk [N/mm]
HSC
M8x40
M10x40
M8x50
M12x60
-A
800
800
800
800
-AR
700
700
700
700
-A
640
640
640
640
-AR
450
450
450
450
[N/mm]
[mm]
-A, AR
36,6
58,0
36,6
84,3
Moment of resistance W
[mm]
-A, AR
31,2
62,3
31,2
109,2
-A
24
48
24
84
-AR
16,7
33,3
16,7
59,0
Material quality
HSC-AR
HSC-A
Part
Material
Cone bolt with , with internal
or external thread
Expansion sleeve and washer
Hexagon nut
Cone bolt with , with internal
or external thread
Expansion sleeve and washer
Hexagon nut
Anchor dimensions
Dimensions of HSC-A and HSC-AR
Anchor version
Thread size
tfix [mm]
max
b
[mm]
ls
[mm]
d
[mm]
e
[mm]
HSC-A(R) M8x40
M8
150
13,5
40,8
13,5
16
HSC-A(R) M10x40
M10
200
15,5
40,8
15,5
20
HSC-A(R) M8x50
M8
150
13,5
50,8
13,5
16
HSC-A(R) M12x60
M12
200
17,5
60,8
17,5
24
110
1 / 2009
Setting
Installation equipment
HSC-A/AR
M8x40
Anchor size
TE-C-HSC-B
TE-C-HSC-MW
HSC-A/AR
M8x50
14x50
14
HSC-A/AR
M10x40
TE 7-C; TE 7-A;
TE 25; TE 35
16x40
16
HSC-A/AR
M12x60
TE 16; TE 16-C; TE 16-M;
TE 25; TE 35;
TE 40; TE 40-AVR
18x60
18
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
Setting details: depth of drill hole h1 and effective anchorage depth hef
1 / 2009
111
M8x40
M10x40
M8x50
M12x60
do
[mm]
14
16
14
18
dcut
[mm]
14,5
16,5
14,5
18,5
h1
[mm]
46
46
56
68
df
[mm]
12
10
30
hef
[mm]
40
40
50
60
tfix
[mm]
15
20
15
20
Torque moment
Tinst
[Nm]
10
20
10
30
Width across
SW
[mm]
13
17
13
19
M8x40
M10x40
M8x50
M12x60
hmin
[mm]
100
100
100
130
smin
[mm]
40
40
50
60
cmin
[mm]
40
40
50
60
scr,N
[mm]
120
120
150
180
ccr,N
[mm]
60
60
75
90
scr,sp
[mm]
130
120
170
180
ccr,sp
[mm]
65
60
85
90
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked
concrete only the critical spacing and critical edge distance for concrete cone failure are decisive.
112
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
M8x40
M10x40
M8x50
M12x60
HSC-A
[kN]
19,5
30,9
19,5
44,9
HSC-AR
[kN]
13,7
21,7
13,7
31,6
1 / 2009
Cracked concrete
No pull-out failure
No pull-out failure
113
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
Non-cracked concrete
Anchor size
Cracked concrete
N Rd,c
[kN]
8,5
8,5
11,9
15,6
a) Splitting resistance must only be considered for non-cracked concrete
6,1
6,1
8,5
11,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
2/3
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
Influence of reinforcement
Anchor size
M8x40
a)
M10x40
M8x50
M12x60
114
a)
a)
1 / 2009
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
M8x40
M10x40
M8x50
M12x60
HSC-A
[kN]
11,7
18,6
11,7
27,0
HSC-AR
[kN]
8,2
13,0
8,2
18,9
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Anchor size
V0Rd,cp
Cracked concrete
17,0
17,0
23,8
31,2
12,1
12,1
17,0
22,3
Cracked concrete
V Rd,c
[kN]
2,5
2,6
3,6
5,3
a) For anchor groups only the anchors close to the edge must be considered.
1,8
1,8
2,6
3,8
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
1 / 2009
115
s/scr,N
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
Influence of reinforcement
Anchor size
M8x40
M10x40
a)
M8x50
a)
M12x60
a)
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
116
1 / 2009
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-02/0042, issue 2008-01-10.
All data applies to concrete C 20/25 fck,cube =25 N/mm.
1 / 2009
117
Design resistance
Single anchor, no edge effects
Non-cracked concrete
Cracked concrete
Anchor size
M8x40 M10x40 M8x50 M12x60 M6x40
Min. base material thickness hmin [mm]
100
100
100
130
100
Tensile NRd
HSC-A
HSC-AR
[kN]
8,5
8,5
11,9
15,6
6,1
6,1
8,5
11,2
[kN]
11,7
17,0
11,7
27,0
11,7
12,1
11,7
22,3
HSC-AR
[kN]
8,2
13,0
8,2
18,9
8,2
12,1
8,2
18,9
Cracked concrete
Anchor size
M8x40 M10x40 M8x50 M12x60 M6x40
Min. base material thickness hmin [mm]
100
100
100
130
100
Min. edge distance cmin [mm]
40
40
50
60
40
Tensile NRd
HSC-A
HSC-AR
[kN]
6,1
6,4
8,3
11,7
4,6
4,6
6,4
8,4
2,6
3,6
5,3
1,8
1,8
2,6
3,8
[kN]
2,5
Cracked concrete
Anchor size
M8x40 M10x40 M8x50 M12x60 M8x40 M10x40 M8x50 M12x60
Min. base material thickness hmin [mm]
100
100
100
130
100
100
100
130
Min. spacing smin [mm]
40
40
50
60
40
40
50
60
Tensile NRd
HSC-A
HSC-AR
118
[kN]
5,6
5,7
7,7
10,4
4,0
4,0
5,7
7,4
11,3
11,7
20,8
8,1
8,1
11,3
14,9
HSC-AR
11,3
8,2
18,9
8,1
8,1
8,2
14,9
[kN]
8,2
1 / 2009
Recommended loads
Single anchor, no edge effects
Non-cracked concrete
Cracked concrete
Anchor size
M8x40 M10x40 M8x50 M12x60 M8x40 M10x40 M8x50 M12x60
Min. base material thickness hmin [mm]
100
100
100
130
100
100
100
130
Tensile Nrec
HSC-A
HSC-AR
[kN]
6,1
6,1
8,5
11,2
4,3
4,3
6,1
8,0
12,1
8,3
19,3
8,3
8,7
8,3
15,9
HSC-AR
9,3
5,9
13,5
5,9
8,7
5,9
13,5
[kN]
5,9
Cracked concrete
Anchor size
M8x40 M10x40 M8x50 M12x60 M6x40
Min. base material thickness hmin [mm]
100
100
100
130
100
Min. edge distance cmin [mm]
40
40
50
60
40
Tensile Nrec
HSC-A
HSC-AR
[kN]
4,3
4,6
5,9
8,4
3,3
3,3
4,5
6,0
1,8
2,6
3,8
1,3
1,3
1,8
2,7
[kN]
1,8
Cracked concrete
Anchor size
M8x40 M10x40 M8x50 M12x60 M8x40 M10x40 M8x50 M12x60
Min. base material thickness hmin [mm]
100
100
100
130
100
100
100
130
Min. spacing smin [mm]
40
40
50
60
40
40
50
60
Tensile Nrec
HSC-A
HSC-AR
[kN]
4,0
4,0
5,5
7,4
2,9
2,9
4,0
5,3
[kN]
8,1
8,1
8,3
14,9
5,8
5,8
8,1
10,6
HSC-AR
[kN]
5,9
8,1
5,9
13,5
5,8
5,8
5,9
10,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
119
Concrete
Tensile
zone
Small edge
distance
and spacing
Fire
resistance
Shock
European
Technical
Approval
Corrosion
resistance
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Shockproof fastenings in civil
defence installations
Fire test report
Assessment report (fire)
-
Authority / Laboratory
CSTB, Paris
IBMB, Braunschweig
warringtonfire
UB 3177/1722-1 / 2006-06-28
WF 166402 / 2007-10-26
120
M6x
40
M8x
40
[kN]
[kN]
16,6
14,8
16,6
16,6
23,3
23,3
30,6
30,6
[kN]
[kN]
10,4
9,1
15,9
13,9
19,8
17,3
19,8
17,3
Cracked concrete
M6x
40
M8x
40
30,6
30,6
13,3
13,3
13,3
13,3
18,6
18,6
24,5
24,5
24,5
24,5
23,4
20,8
10,4
9,1
15,9
13,9
19,8
17,3
19,8
17,3
23,4
20,8
1 / 2009
M6x
40
M8x
40
[kN]
[kN]
12,8
12,8
12,8
12,8
17,8
17,8
23,4
23,4
[kN]
[kN]
8,0
7,0
12,2
10,7
15,2
13,3
15,2
13,3
Cracked concrete
M6x
40
M8x
40
23,4
23,4
9,1
9,1
9,1
9,1
12,7
12,7
16,7
16,7
16,7
16,7
18,2
16,0
8,0
7,0
12,2
10,7
15,2
13,3
15,2
13,3
18,2
16,0
M6x
40
M8x
40
[kN]
[kN]
8,5
7,5
8,5
8,5
11,9
11,9
15,6
14,2
[kN]
[kN]
6,4
4,5
9,8
6,9
12,2
8,5
12,2
8,5
Cracked concrete
M6x
40
M8x
40
15,6
15,6
6,1
6,1
6,1
6,1
8,5
8,5
11,2
11,2
11,2
11,2
14,6
10,3
6,4
4,5
9,8
6,9
12,2
8,5
12,2
8,5
14,6
10,3
M6x
40
M8x
40
Cracked concrete
M6x
40
M8x
40
Tensile Nrec a)
HSC-I
[kN]
6,1
6,1
8,5
11,2
11,2
4,3
4,3
6,1
8,0
8,0
HSC-IR
[kN]
5,4
6,1
8,5
10,1
11,2
4,3
4,3
6,1
8,0
8,0
Shear Vrec a)
HSC-I
[kN]
4,6
7,0
8,7
8,7
10,4
4,6
7,0
8,7
8,7
10,4
HSC-IR
[kN]
3,2
4,9
6,1
6,1
7,3
3,2
4,9
6,1
6,1
7,3
- With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety
factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Materials
Mechanical properties
Anchor size
HSC
-I
M6x40
800
M8x40
800
M10x50
800
M10x60
800
M12x60
800
-IR
600
600
700
700
700
-I
640
640
640
640
640
-IR
355
355
350
350
340
[mm]
-I,IR
22,0
28,3
34,6
34,6
40,8
[mm]
-I,IR
20,1
36,6
58,0
58,0
84,3
[mm]
-I,IR
-I
12,7
9,6
31,2
24
62,3
48
62,3
48
109,2
84
-IR
7,1
16,7
33,3
33,3
59,0
[N/mm]
121
Material quality
HSC-IR
HSC-I
Part
Material
Cone bolt with , with internal
or external thread
Expansion sleeve and washer
Hexagon nut
Cone bolt with , with internal
or external thread
Expansion sleeve and washer
Hexagon nut
Anchor dimensions
Dimensions of HSC-I and HSC-IR
Anchor version
Thread size
b
[mm]
ls
[mm]
d
[mm]
lb
[mm]
HSC-II M6x40
M6
13,5
40,8
13,5
43,3
HSC-II M8x40
M8
15,5
40,8
15,5
43,8
HSC-II M10x50
M10
17,5
50,8
17,5
54,8
HSC-II M10x60
M10
17,5
60,8
17,5
64,8
HSC-II M12x60
M12
19,5
60,8
19,5
64,8
Setting
Installation equipment
HSC-I/IR
M6x40
Anchor size
122
TE-CHSC-B
TE-C HSC-MW
TE-C HSC-EW
HSC-I/IR
M8x40
HSC-I/IR
M10x50
HSC-I/IR
M10x60
16x40
16
16
18x50
18
18
18x60
18
18
HSC-I/IR
M12x60
TE 16; TE 16-C; TE 16-M;
TE 25, TE 35; TE 40;
TE 40-AVR
20x60
20
20
1 / 2009
Setting instruction
For HSC-I: fastening carbon steel screw or threaded rod. Minimum strength class 8.8 according to ESO 8898-1
For HSC-IR: fastening stainless steel screw or threaded rod: minimum strength class A4-70 according to EN ISO
3506
For detailed information on installation see instruction for use given with the package of the product.
Setting details: depth of drill hole h1 and effective anchorage depth hef
1 / 2009
123
Setting details
Anchor version
M6x40
M8x40
M10x50
M10x60
M12x60
d0
[mm]
14
16
18
18
20
dcut
[mm]
14,5
16,5
18,5
18,5
20,5
h1
[mm]
46
46
56
68
68
df
[mm]
12
12
14
hef
[mm]
40
40
50
60
60
Screwing depth
min s
[mm]
10
10
12
max s
[mm]
16
22
28
28
30
Width across
SW
[mm]
10
13
17
17
19
Installation torque
Tinst
[Nm]
10
10
20
30
30
M6x40
M8x40
M10x50
M10x60
M12x60
hmin
[mm]
100
100
110
130
130
smin
[mm]
40
40
50
60
60
cmin
[mm]
40
40
50
60
60
scr,N
[mm]
120
120
150
180
180
ccr,N
[mm]
60
60
75
90
90
scr,sp
[mm]
130
120
170
180
180
ccr,sp
[mm]
65
60
85
90
90
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked
concrete only the critical spacing and critical edge distance for concrete cone failure are decisive.
124
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
M6x40
M8x40
M10x50
M10x60
M12x60
HSC-I
[kN]
10,7
16,3
20,2
20,2
24,3
HSC-IR
[kN]
7,5
11,4
14,2
14,2
17,1
1 / 2009
M6x
40
[kN]
M8x
40
No pull-out failure
Cracked concrete
M6x
40
M8x
40
No pull-out failure
125
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
Non-cracked concrete
Anchor size
M6x
40
M8x
40
Cracked concrete
M6x
40
M8x
40
N0Rd,c
[kN]
8,5
8,5
11,9 15,6 15,6
6,1
- Splitting resistance must only be considered for non-cracked concrete
6,1
11,2
11,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
fB =
-
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
2/3
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
Influence of reinforcement
Anchor size
M6x40
M8x40
M10x50
M10x60
M12x60
126
1 / 2009
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
M6x40
M8x40
M10x50
M10x60
M12x60
HSC-I
[kN]
6,4
9,8
12,2
12,2
14,6
HSC-IR
[kN]
4,5
6,9
8,5
8,5
10,3
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Anchor size
V0Rd,cp
[kN]
Cracked concrete
M6x
40
M8x
40
M6x
40
M8x
40
17,0
17,0
23,8
12,1
12,1
17,0
31,2
31,2
22,3
22,3
M6x
40
M8x
40
Cracked concrete
M6x
40
M8x
40
V0Rd,c
[kN]
2,5
2,6
3,9
5,3
5,4
1,8
- For anchor groups only the anchors close to the edge must be considered.
1,8
3,8
3,9
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
fB =
-
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
127
s/scr,N
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
Influence of reinforcement
Anchor size
M6x40
M8x40
a)
M10x50
a)
M10x60
a)
M12x60
a)
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
c/hef
0,50
0,75
1,00
1,25
1,50
1,75
2,00
2,25
2,50
2,75
3,00
3,25
3,50
3,75
4,00
4,25
4,50
4,75
5,00
5,25
5,50
-
128
Single
anchor 0,75 1,50 2,25 3,00 3,75
0,35
0,27 0,35 0,35 0,35 0,35
0,65
0,43 0,54 0,65 0,65 0,65
1,00
0,63 0,75 0,88 1,00 1,00
1,40
0,84 0,98 1,12 1,26 1,40
1,84
1,07 1,22 1,38 1,53 1,68
2,32
1,32 1,49 1,65 1,82 1,98
2,83
1,59 1,77 1,94 2,12 2,30
3,38
1,88 2,06 2,25 2,44 2,63
3,95
2,17 2,37 2,57 2,77 2,96
4,56
2,49 2,69 2,90 3,11 3,32
5,20
2,81 3,03 3,25 3,46 3,68
5,86
3,15 3,38 3,61 3,83 4,06
6,55
3,51 3,74 3,98 4,21 4,44
7,26
3,87 4,12 4,36 4,60 4,84
8,00
4,25 4,50 4,75 5,00 5,25
8,76
4,64 4,90 5,15 5,41 5,67
9,55
5,04 5,30 5,57 5,83 6,10
10,35 5,45 5,72 5,99 6,27 6,54
11,18 5,87 6,15 6,43 6,71 6,99
12,03 6,30 6,59 6,87 7,16 7,45
12,90 6,74 7,04 7,33 7,62 7,92
The anchor spacing and the edge distance
the minimum edge distance cmin.
1 / 2009
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-02/0042, issue 2008-01-10.
All data applies to concrete C 20/25 fck,cube =25 N/mm.
1 / 2009
129
Design resistance
Single anchor, no edge effects
Non-cracked concrete
Anchor size
M6x
40
M8x
40
100
100
110
130
8,5
8,5
11,9
HSC-IR
[kN]
7,5
Shear VRd, without lever arm
8,5
HSC-I
[kN]
6,4
HSC-IR
[kN]
4,5
[kN]
Cracked concrete
M6x
40
M8x
40
130
100
100
110
130
130
15,6
15,6
6,1
6,1
8,5
11,2
11,2
11,9
14,2
15,6
6,1
6,1
8,5
11,2
11,2
9,8
12,2
12,2
14,6
6,4
9,8
12,2
12,2
14,6
6,9
8,5
8,5
10,3
4,5
6,9
8,5
8,5
10,3
[kN]
M6x
40
M8x
40
100
40
100
40
110
50
130
60
6,1
6,4
4,2
2,6
3,9
Cracked concrete
M6x
40
M8x
40
130
60
100
40
100
40
110
50
130
60
130
60
11,7
11,7
4,6
4,6
6,4
8,4
8,4
5,3
5,4
1,8
1,8
2,8
3,8
3,9
[kN]
2,5
[kN]
M6x
40
M8x
40
100
60
100
70
110
80
130
100
5,6
5,7
7,7
Cracked concrete
M6x
40
M8x
40
130
125
100
60
100
70
110
80
130
100
130
125
10,4
10,4
4,0
4,0
5,7
7,4
7,4
130
HSC-I
[kN]
6,4
9,8
12,2
12,2
14,6
6,4
8,1
11,3
12,2
14,6
HSC-IR
[kN]
4,5
6,9
8,5
8,5
10,3
4,5
6,9
8,5
8,5
10,3
1 / 2009
Recommended loads
Single anchor, no edge effects
Non-cracked concrete
Anchor size
M6x
40
M8x
40
100
100
110
130
6,1
6,1
8,5
5,4
6,1
[kN]
[kN]
3,2
Cracked concrete
M6x
40
M8x
40
130
100
100
110
130
130
11,2
11,2
4,3
4,3
6,1
8,0
8,0
8,5
10,1
11,2
4,3
4,3
6,1
8,0
8,0
7,0
8,7
8,7
10,4
4,6
7,0
8,7
8,7
10,4
4,9
6,1
6,1
7,3
3,2
4,9
6,1
6,1
7,3
[kN]
M6x
40
M8x
40
100
40
100
40
110
50
130
60
4,3
4,6
5,9
1,8
2,8
Cracked concrete
M6x
40
M8x
40
130
60
100
40
100
40
110
50
130
60
130
60
8,4
8,4
3,3
3,3
4,5
6,0
6,0
3,8
3,9
1,3
1,3
2,0
2,7
2,8
[kN]
1,8
[kN]
M6x
40
M8x
40
100
60
100
70
110
80
130
100
4,0
4,0
5,5
Cracked concrete
M6x
40
M8x
40
130
125
100
60
100
70
110
80
130
100
130
125
7,4
7,4
2,9
2,9
4,0
5,3
5,3
[kN]
4,6
7,0
8,7
8,7
10,4
4,6
5,8
8,1
8,7
10,4
HSC-IR
[kN]
3,2
4,9
6,1
6,1
7,3
3,2
4,9
6,1
6,1
7,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
131
Benefits
- suitable for non-cracked and
cracked concrete C 20/25 to
C 50/60
- quick and simple setting
operation
- safety wedge for certain follow up
expansion
HST
Carbon steel
HST-R
Stainless steel
HST-HCR
High corrosion
resistance steel
Concrete
Tensile
zone
Fire
resistance
Shock
Corrosion
resistance
High
corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
Authority / Laboratory
European technical approval a)
DIBt, Berlin
Shockproof fastenings in civil
Bundesamt fr Zivilschutz, Bern
defence installations
Fire test report
DIBt, Berlin
Fire test report ZTV-Tunnel
IBMB, Braunschweig
Assessment report (fire)
warringtonfire
a) All data given in this section according ETA-98/0001, issue 2008-11-18.
132
1 / 2009
Cracked concrete
M8
M8
[kN]
[kN]
[kN]
16,6
18,1
15,2
22,3
26,7
22,7
35,2
35,1
32,4
48,7
49,8
45,5
76,0
77,4
-
86,1
79,1
-
10,3
12,7
13,8
11,6
18,4
16,2
21,9
20,1
21,5
31,1
36,0
32,4
44,9
55,1
-
[kN]
[kN]
[kN]
17,6
15,8
17,6
27,8
24,4
27,8
40,5
35,4
40,5
67,8
61,2
75,4
102,9 112,3
95,6 137,7
-
17,6
15,8
17,6
27,8
24,4
27,8
40,5
35,4
40,5
67,8
61,2
75,4
102,9 112,3
95,6 137,7
-
60,2
70,5
-
Characteristic resistance
Non-cracked concrete
Anchor size
Tensile NRk
HST
HST-R
HST-HCR
Shear VRk
HST
HST-R
HST-HCR
Cracked concrete
M8
M8
[kN]
[kN]
[kN]
9,0
9,0
9,0
16,0
16,0
16,0
20,0
20,0
20,0
35,0
35,0
35,0
50,0
50,0
-
60,0
60,0
-
5,0
5,0
5,0
9,0
9,0
9,0
12,0
12,0
12,0
20,0
25,0
25,0
30,0
30,0
-
40,0
40,0
-
[kN]
[kN]
[kN]
14,0
13,0
13,0
23,5
20,0
20,0
35,0
30,0
30,0
55,0
50,0
55,0
84,0
60,0
-
94,0
80,0
-
14,0
13,0
13,0
23,5
20,0
20,0
35,0
30,0
30,0
55,0
50,0
53,5
84,0
60,0
-
94,0
80,0
-
Design resistance
Non-cracked concrete
Anchor size
Tensile NRd
HST
HST-R
HST-HCR
Shear VRd
HST
HST-R
HST-HCR
Cracked concrete
M8
M8
[kN]
5,0
6,0
6,0
10,7
10,7
10,7
13,3
13,3
13,3
23,3
23,3
23,3
33,3
33,3
-
40,0
40,0
-
2,8
3,3
3,3
6,0
6,0
6,0
8,0
8,0
8,0
13,3
16,7
16,7
20,0
20,0
-
26,7
26,7
-
[kN]
[kN]
[kN]
11,2
10,4
10,4
18,8
16,0
16,0
28,0
24,0
24,0
44,0
38,5
44,0
67,2
41,7
-
62,7
55,6
-
11,2
10,4
10,4
18,8
16,0
16,0
28,0
24,0
24,0
44,0
35,6
35,6
60,9
41,7
-
62,7
55,6
-
[kN]
Recommended loads
Non-cracked concrete
Cracked concrete
Anchor size
M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile Nreca)
HST
[kN]
3,6 7,6 9,5 16,7 23,8 28,6 2,0 4,3 5,7 9,5 14,3 19,0
HST-R
[kN]
4,3 7,6 9,5 16,7 23,8 28,6 2,4 4,3 5,7 11,9 14,3 19,0
HST-HCR
[kN]
4,3 7,6 9,5 16,7
2,4 4,3 5,7 11,9
Shear Vrec a)
HST
[kN]
8,0 13,4 20,0 31,4 48,0 44,8 8,0 13,4 20,0 31,4 43,5 44,8
HST-R
[kN]
7,4 11,4 17,1 27,5 29,8 39,7 7,4 11,4 17,1 25,5 29,8 39,7
HST-HCR
[kN]
7,4 11,4 17,1 31,4
7,4 11,4 17,1 25,5
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
133
Materials
Mechanical properties of HST, HST-R, HST-HCR
Anchor size
Nominal
tensile
strength fuk
Yield strength
fyk
HST
HST-R
HST-HCR
HST
HST-R
HST-HCR
Stressed crosssection As
Moment of
resistance W
Char. bending
resistance
M0Rk,s
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
800
720
800
640
575
640
M10
800
700
800
640
560
640
M12
800
700
800
640
560
640
M16
720
650
800
580
500
640
M20
700
650
560
450
-
M24
530
650
451
450
-
[mm]
36,6
58,0
84,3
157
245
353
[mm]
31,2
62,3
109,2
277,5
540,9
935,5
30
27
30
60
53
60
105
92
105
240
216
266
454
422
-
595
730
-
HST [Nm]
HST-R [Nm]
HST-HCR [Nm]
Material quality
Part
Bolt
HST
HST-R
HST-HCR
Material
Carbon steel, galvanised to min. 5 m
Stainless steel
High corrosion resistant steel
Anchor dimensions
Anchor size
M8
M10
M12
M16
M20
M24
tfix,min
[mm]
tfix,max
[mm]
195
200
200
235
305
330
dR
[mm]
5,5
7,2
8,5
11,6
14,6
17,4
l1,min
[mm]
75
90
115
140
170
200
l1,max
[mm]
260
280
295
350
450
500
l2
[mm]
14,8
18,2
22,7
24,3
28,3
36
HST
M..
dR
l1
l2
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
134
M8
M10
M12
M16
M20
M24
TE2 TE16
TE40 TE70
hammer, torque wrench, blow out pump
1 / 2009
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
HST
M
Setting details: depth of drill hole h1 and effective anchorage depth hef
Tinst
hef
h1
Setting details HST, HST-R, HST-HCR
M8
M10
M12
M16
M20
M24
do
[mm]
10
12
16
20
24
dcut
[mm]
8,45
10,45
12,5
16,5
20,55
24,55
h1
[mm]
65
80
95
115
140
170
df
[mm]
12
14
18
22
26
hef
[mm]
47
60
70
82
101
125
Torque moment
Tinst
[Nm]
20
45
60
110
240
300
Width across
SW
[mm]
13
17
19
24
30
36
1 / 2009
135
Setting parameters
Anchor size
Minimum base material thickness
HST
Minimum spacing
in non-cracked
concrete
HST-R
HST-HCR
HST
Minimum spacing
in cracked concrete
HST-R
HST-HCR
Minimum edge
distance
in non-cracked
concrete
Minimum edge
distance
in cracked concrete
HST
HST-R
HST-HCR
HST
HST-R
HST-HCR
hmin
smin
for c
smin
for c
smin
for c
smin
for c
smin
for c
smin
for c
cmin
for s
cmin
for s
cmin
for s
cmin
for s
cmin
for s
scr,sp
scr,N
ccr,sp
ccr,N
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
M8
100
60
50
60
60
60
50
40
50
40
50
40
50
50
60
60
60
60
60
45
50
45
50
M10
120
55
80
55
70
55
70
55
70
55
65
55
70
55
115
50
115
55
115
55
90
50
90
M12
140
60
85
60
80
60
80
60
75
60
75
60
75
55
145
55
145
55
145
55
120
55
110
M16
160
70
110
70
110
70
110
70
100
70
100
70
100
85
150
70
160
70
160
70
150
60
160
M20
200
100
225
100
195
100
160
100
130
140
270
140
210
100
225
100
160
M24
250
125
255
125
205
125
180
125
130
170
295
150
235
125
240
125
140
[mm]
141
180
210
246
303
375
[mm]
71
90
105
123
152
188
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
1 / 2009
Valid for a group of two anchors. (The method may also be applied for anchor groups
with more than two anchors or more than one edge. The influencing factors must then be
considered for each edge distance and spacing. The calculated design loads are then on
the save side: They will be lower than the exact values according ETAG 001, Annex C.
To avoid this, it is recommended to use the anchor design software PROFIS anchor)
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
HST
HST-R
HST-HCR
M8
12,7
11,3
12,9
[kN]
[kN]
[kN]
M10
21,3
18,7
21,5
M12
28,7
26,7
30,5
M16
50,0
44,2
56,3
M20
50,0
63
-
M24
90,0
90,2
-
Rd,p
HST
HST-R
HST-HCR
[kN]
[kN]
[kN]
Cracked concrete
M8
M8
5,0
6,0
6,0
10,7
10,7
10,7
2,8
3,3
3,3
13,3
13,3
13,3
23,3
23,3
23,3
33,3
33,3
-
40,0
40,0
-
8,0
8,0
8,0
13,3
16,7
16,7
20,0
20,0
-
26,7
26,7
-
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
Non-cracked concrete
Anchor size
M8
HST
[kN]
9,0 15,6 19,7 24,9 34,1
47
HST-R
[kN]
10,8 15,6 19,7 24,9 34,1
47
HST-HCR [kN]
10,8 15,6 19,7 24,9
a) Splitting resistance must only be considered for non-cracked concrete
N0Rd,c
1 / 2009
Cracked concrete
M8
6,4
7,7
7,7
11,2
11,2
11,2
14,1
14,1
14,1
17,8
17,8
17,8
24,4
24,4
-
33,5
33,5
-
137
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
2/3
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
Influence of reinforcement
Anchor size
M8
M10
a)
M12
a)
a)
M16
M20
M24
a)
0,74
0,8
0,85
0,91
1
1
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
138
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
1 / 2009
M8
M10
M12
M16
M20
M24
HST
[kN]
11,2
18,8
28,0
44,0
67,2
62,7
HST-R
[kN]
10,4
16,0
24,0
38,5
41,7
55,6
HST-HCR [kN]
10,4
16,0
24,0
44,0
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Anchor size
M8
HST
HST-R
HST-HCR
V0Rd,cp
[kN]
[kN]
[kN]
Cracked concrete
M8
21,6 31,2 43,3 62,4 85,3 117,4 15,5 22,3 30,9 44,5 60,9 83,8
21,6 31,2 39,4 49,9 68,2 93,9 15,5 22,3 28,1 35,6 48,7 67,1
21,6 31,2 39,4 49,9
15,5 22,3 28,1 35,6
-
M8
Cracked concrete
M8
HST
[kN]
3,0 3,9 4,2 9,1 21,5 31,7 1,8
0
V Rd,c
HST-R
[kN]
3,9 3,4 4,2 6,8 21,5 26,3 1,8
HST-HCR [kN]
3,9 3,9 4,2 6,8
1,8
a) For anchor groups only the anchors close to the edge must be considered.
3,0
3,0
3,0
4,9
3,9
3,9
9,3
9,3
-
14,3
14,3
-
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1/2 a)
fB =
(fck,cube/25N/mm)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f1,N =
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1 / 2009
139
Influence of reinforcement
Anchor size
M8
M10
a)
M12
a)
M16
a)
M20
M24
a)
0,74
0,8
0,85
0,91
1
1
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
140
1 / 2009
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-98/0001, issue 2008-11-18.
All data applies to concrete C 20/25 fck,cube =25 N/mm.
Design resistance
Single anchor, no edge effects
Non-cracked concrete
Anchor size
M8
Min. base material thickness hmin [mm] 100
Tensile NRd
HST
[kN]
5,0
HST-R
[kN]
6,0
HST-HCR
[kN]
6,0
Shear VRd, without lever arm
HST
[kN] 11,2
HST-R
[kN] 10,4
HST-HCR
[kN] 10,4
Cracked concrete
M8
100
10,7
10,7
10,7
13,3
13,3
13,3
23,3
23,3
23,3
33,3
33,3
-
40,0
40,0
-
2,8
3,3
3,3
6,0
6,0
6,0
8,0
8,0
8,0
13,3
16,7
16,7
20,0
20,0
-
26,7
26,7
-
18,8
16,0
16,0
28,0
24,0
24,0
44,0
38,5
44,0
67,2
41,7
-
62,7
55,6
-
11,2
10,4
10,4
18,8
16,0
16,0
28,0
24,0
24,0
44,0
35,6
35,6
60,9
41,7
-
62,7
55,6
-
M8
100
45
45
45
10,7
10,5
10,7
12,9
12,9
12,9
19,1
17,0
17,0
32,1
32,1
-
40,0
39,7
-
2,8
3,3
3,3
6,0
6,0
6,0
8,0
8,0
8,0
12,2
11,2
11,2
18,2
18,2
-
25,2
25,2
-
3,9
3,4
3,9
4,2
4,2
4,2
9,1
6,8
6,8
20,8
20,8
-
31,3
26,3
-
1,8
1,8
1,8
2,8
2,4
2,4
3,0
3,0
3,0
4,9
3,9
3,9
9,3
9,3
-
14,3
14,3
-
Cracked concrete
1 / 2009
Cracked concrete
M8
100
40
10,2
10,2
10,2
12,7
12,7
12,7
16,0
16,0
16,0
22,7
22,7
-
31,3
31,3
-
2,8
3,3
3,3
6,0
6,0
6,0
8,0
8,0
8,0
11,4
11,4
11,4
16,2
16,2
-
22,4
22,4
-
18,8
16,0
16,0
27,8
24,0
24,0
40,1
32,0
32,0
56,7
41,7
-
62,7
55,6
-
9,9
9,9
9,9
14,6
14,6
14,6
19,9
18,1
18,1
22,9
22,9
22,9
40,5
32,4
-
55,9
44,7
-
141
Recommended loads
Single anchor, no edge effects
Non-cracked concrete
Anchor size
M8
Min. base material thickness hmin [mm] 100
Tensile Nrec
HST
[kN]
3,6
HST-R
[kN]
4,3
HST-HCR
[kN]
4,3
Shear Vrec, without lever arm
HST
[kN]
8,0
HST-R
[kN]
7,4
HST-HCR
[kN]
7,4
Cracked concrete
M8
100
7,6
7,6
7,6
9,5
9,5
9,5
16,6
16,6
16,6
23,8
23,8
-
28,6
28,6
-
2,0
2,4
2,4
4,3
4,3
4,3
5,7
5,7
5,7
9,5
11,9
11,9
14,3
14,3
-
19,0
19,0
-
13,4
11,4
11,4
20,0
17,1
17,1
31,4
27,5
31,4
48,0
29,8
-
44,8
39,7
-
8,0
7,4
7,4
13,4
11,4
11,4
20,0
17,1
17,1
31,4
25,5
25,5
43,5
29,8
-
44,8
39,7
-
M8
100
45
45
45
Cracked concrete
7,6
7,5
7,6
9,2
9,2
9,2
13,6
12,1
12,1
22,9
22,9
-
28,6
28,4
-
2,0
2,4
2,4
4,3
4,3
4,3
5,7
5,7
5,7
8,7
8,0
8,0
13,0
13,0
-
18,0
18,0
-
2,8
2,4
2,8
3,0
3,0
3,0
6,5
4,9
4,9
14,9
14,9
-
22,4
18,8
-
1,3
1,3
1,3
2,0
1,7
1,7
2,2
2,2
2,2
3,5
2,8
2,8
6,6
6,6
-
10,2
10,2
-
Cracked concrete
M8
100
40
7,3
7,3
7,3
9,1
9,1
9,1
11,4
11,4
11,4
16,2
16,2
-
22,4
22,4
-
2,0
2,4
2,4
4,3
4,3
4,3
5,7
5,7
5,7
8,2
8,2
8,2
11,6
11,6
-
16,0
16,0
-
13,4
11,4
11,4
19,9
17,1
17,1
28,6
22,9
22,9
40,5
29,8
-
44,8
39,7
-
7,1
7,1
7,1
10,4
10,4
10,4
14,2
12,9
12,9
16,4
16,4
16,4
28,9
23,1
-
39,9
31,9
-
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
142
1 / 2009
1 / 2009
143
Benefits
- two setting depths
HSA
Carbon steel
- setting mark
HSA-R
Stainless steel
HSA-F
Carbon steel, hot-dip
galvanised
Concrete
Fire
resistance
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
Authority / Laboratory
No. / date of issue
European technical approval a)
CSTB, Paris
ETA-99/0001 / 2008-03-13
Fire test report
IBMB, Braunschweig
UB 3049/8151 / 2006-05-03
Assessment report (fire)
warringtonfire
WF 166404/ 2007-10-26
a) All data given in this section for HSA and HSA-R M6 to M12 according ETA-99/0001, issue 2008-03-13. HSA-F
and HAS-R M16 + M20 have no approval.
144
M6
M8
M6
M8
[kN]
[kN]
[kN]
12,5
11,2
11,1
20,1
17,2
18,3
20,6
20,1
25,3
39,7
33,6
38,3
62,5
52,3
45,6
100,1
69,0
64,4
9,2
9,2
10,4
12,8
12,8
14,2
18,3
18,3
20,8
19,8
19,8
26,8
38,3
30,0
39,8
44,4
43,0
54,1
[kN]
[kN]
[kN]
8,7
7,2
8,7
15,8
13,2
15,8
25,1
20,9
25,1
36,4
30,3
36,4
63,1
61,2
63,1
105,8
95,6
105,8
8,7
8,7
15,8
15,8
25,1
25,1
36,4
36,4
63,1
63,1
105,8
-105,8
1 / 2009
Characteristic resistance
Anchor size
Tensile NRk
HSA
HSA-R
HSA-F
Shear VRk
HSA
HSA-R
HSA-F
M6
M8
M6
M8
[kN]
[kN]
[kN]
6
6
6
12
12
12
16
12
16
25
25
25
38,8
38,7
35
52,7
44,1
50
5
4
9
7,5
9
12
12
12
17,8
17,8
16
25,8
23,0
20
34,7
33,0
30
[kN]
[kN]
[kN]
6,5
6,0
6,5
12
11,0
12
19,5
17,0
19,5
30,5
25,0
30,5
55,0
35,0
55,0
85,0
50,0
85,0
6,5
6,5
12,0
10,4
12,0
19,5
13,7
19,5
30,5
17,8
30,5
55,0
35,0
55,0
85,0
50,0
85,0
Design resistance
Anchor size
Tensile NRd
HSA
HSA-R
HSA-F
Shear VRd
HSA
HSA-R
HSA-F
M6
M8
M6
M8
[kN]
[kN]
[kN]
3,3
3,3
3,3
8,0
6,7
6,7
10,7
6,7
7,6
16,7
11,9
11,9
25,9
18,1
23,3
35,1
20,6
33,3
2,8
1,9
6,0
4,2
6
8,0
5,7
6,7
11,9
8,5
7,6
17,2
10,8
13,3
23,1
15,4
20
[kN]
[kN]
[kN]
5,2
4,0
5,2
9,6
7,3
9,6
15,6
11,3
15,6
24,4
16,7
24,4
44,0
38,5
44,0
68,0
41,7
68,0
5,2
5,2
9,6
7,0
9,6
15,6
9,1
15,6
23,8
11,9
23,8
44,0
38,5
44,0
68,0
41,7
68,0
Recommended loads
Standard embedment depth
Anchor size
M6 M8 M10 M12 M16 M20 M6 M8 M10 M12 M16 M20
Tensile Nreca)
HSA
[kN]
2,4
5,7
7,6 11,9 18,5 25,1 2,0
4,3
5,7
8,5 12,3 16,5
HSA-R
[kN]
2,4
4,8
4,8
8,5 12,9 14,7
3,0
4,1
6,1
7,7 11,0HSA-F
[kN]
2,4
4,8
5,4
8,5 16,6 23,8 1,4
4,3
4,8
5,4
9,5 14,3
Shear Vrec a)
HSA
[kN]
3,7
6,9 11,1 17,4 31,4 48,6 3,7
6,9 11,1 17,0 31,4 48,6
HSA-R
2,9
5,2
8,1 11,9 27,5 29,8
5,0
6,5
8,5 27,5 29,8
HSA-F
[kN]
3,7
6,9 11,1 17,4 31,4 48,6 3,7
6,9 11,1 17,0 31,4 48,6
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Materials
Mechanical properties of HSA, HSA-R, HSA-F
Anchor size
Nominal
tensile
strength fuk
Yield strength
fyk
HSA
HSA-R
HSA-F
HSA
HSA-R
HSA-F
Stressed crosssection As
Moment of
resistance W
Char. bending HSA
resistance
HSA-R
M0Rk,s
HSA-F
1 / 2009
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M6
720
600
720
576
400
576
M8
720
600
720
576
400
576
M10
720
600
720
576
400
576
M12
720
600
720
576
400
576
M16
670
450
670
536
536
M20
720
400
720
576
576
[mm]
20,1
36,6
58,0
84,3
157
245
[mm]
12,7
31,2
62,3
109,2
277,5
540,9
[Nm]
[Nm]
[Nm]
11
9
11
27
22
27
54
45
54
94
79
94
223
150
223
454
252
454
145
Material quality
Part
Material
Bolt
HSA
HSA-R
Stainless steel
HSA-F
Anchor dimensions
Standard embedment depth
Anchor size
M6
M8
[mm]
tfix,max [mm]
45
72
dR
[mm]
4,2
l1,max
l2
tfix,min
M16
M20
M6
M8
10
70
205
125
30
55
85
77
225
145
55
5,8
7,6
12,2
15,4
4,2
5,8
7,6
[mm] 100
137
140
300
240
170
100
137
140
300
240
170
[mm]
24,8
29
8,2
29
8,2
M10 M12
12,2 15,4
dR
Minimum thickness of
fixture
Maximum thickness of
fixture
Shaft diameter at the
cone
Maximum length of the
anchor
Length of expansion
sleeve
l1
l2
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
M6
M8
M10
M12
M16
TE2 TE16
M20
TE40
TE70
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
146
1 / 2009
Setting details: depth of drill hole h1 and effective anchorage depth hef
Tinst
hef
h1
M6
M8
8
M10 M12
Nominal diameter of
drill bit
do
[mm]
Cutting diameter of
drill bit
dcut
[mm]
6,4
h1
[mm]
55
65
70
df
[mm]
hef
[mm]
40
Torque moment
Tinst
[Nm]
Width across
SW
[mm]
Diameter of clearance
hole in the fixture
Effective anchorage
depth
1 / 2009
10
12
M16
M20
M6
M8
16
20
12
16
20
16,5 20,55
6,4
95
115
130
45
50
60
70
90
105
12
14
18
22
12
14
18
22
48
50
70
84
103
30
35
42
50
64
78
15
30
50
100
200
15
30
50
100
200
10
13
17
19
24
30
10
13
17
19
24
30
147
Setting parameters
Anchor size
Minimum base material
[mm]
thickness hmin
Minimum spacing smin
HSA
[mm]
HSA-R
[mm]
HSA-F
[mm]
Minimum edge distance cmin
HSA
[mm]
HSA-R
[mm]
HSA-F
[mm]
Critical spacing for splitting failure
scr,sp
HSA
[mm]
HSA-R
[mm]
HSA-F
[mm]
Critical edge distance for splitting
failure ccr,sp
HSA
[mm]
HSA-R
[mm]
HSA-F
[mm]
Critical spacing for concrete cone
failure scr,N
HSA
[mm]
HSA-R
[mm]
HSA-F
[mm]
Critical edge distance for concrete
cone failure ccr,N
HSA
[mm]
HSA-R
[mm]
HSA-F
[mm]
M6
M8
M6
M8
100
100
100
140
170
210
100
100
100
100
130
160
40
40
50
50
55
65
75
100
90
-
105
-
35
-
35
35
55
55
100
100
100
-
100
-
120
145
150
210
250
310
90
105
125
150
190
235
50
50
60
60
60
72
65
75
75
90
100
105
105
126
125
155
40
45
45
45
53
65
65
63
100
100
75
100
96
115
117
200
200
240
240
270
270
378
380
454
500
556
620
150
-
300
420
500
620
180
270
270
300
422
470
290
226
230
252
346
380
240
176
180
210
380
470
100
100
120
120
120
145
135
135
150
189
190
210
227
250
250
278
310
310
75
90
88
90
105
113
115
125
135
135
150
173
190
190
211
235
235
120
120
144
150
150
150
210
210
252
250
309
310
90
-
150
210
250
310
90
150
150
150
234
235
145
126
130
125
192
190
120
105
110
105
190
235
60
60
60
72
75
72
75
75
75
105
105
105
126
126
126
155
155
155
45
45
53
55
53
63
65
63
75
100
75
96
96
96
117
117
117
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
148
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
HSA
HSA-R
[kN]
[kN]
M6
M8
M10
M12
M16
M20
6,3
6,9
12,0
12,5
21,0
21,9
29,7
30,6
50,7
-
89,3
-
1 / 2009
HSA
HSA-R
[kN]
[kN]
M6
M8
M6
M8
3,3
3,3
8
6,7
10,7
6,7
2,8
-
6,0
8,0
4,2
5,7 no p/o
16,7
11,9
No pull-out
-
149
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
Standard embedment depth
M6
M6
M8
HSA
[kN]
7,1 11,2 11,9 19,7 25,9 35,1
HSA-R
[kN]
7,1
9,3
9,9 14,1
a) Splitting resistance must only be considered for non-cracked concrete
4,6
-
7,0
5,8
Anchor size
M8
N0Rd,c
11,9
8,5
17,2
-
23,1
-
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
2/3
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
Influence of reinforcement
Anchor size
M6
M8
M10
0,70 a)
0,74 a)
0,75 a)
a)
a)
a)
M12
M16
M20
a)
0,92 a)
a)
a)
150
0,85
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
M6
M8
M10
M12
M16
M20
HSA
[kN]
5,2
9,6
15,6
24,4
44
68
HSA-R
[kN]
7,3
11,3
16,7
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Anchor size
HSA
HSA-R
V0Rd,cp
[kN]
[kN]
M6
M8
M6
M8
8,5
8,5
11,2
11,2
23,8
11,9
5,5
-
10,4
7,0
18,3
9,1
39,4
39,4
51,7
-
70,2
-
23,8
11,9
49,9
-
81,0
-
M6
M6
M8
HSA
[kN]
2,7
4,0
4,8
8,8 12,6 18,2 1,8
HSA-R
[kN]
2,7
4,0
6,0 10,4
a) For anchor groups only the anchors close to the edge must be considered.
2,4
2,4
Anchor size
M8
V0Rd,c
9,7
9,7
11,1
-
15,2
-
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
1 / 2009
151
s/scr,N
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
Influence of reinforcement
Anchor size
M6
M8
M10
M12
M16
M20
0,70 a)
0,74 a)
0,75 a)
0,85 a)
0,92 a)
a)
a)
a)
a)
a)
0,65
0,68
0,71
0,75
0,82
0,89 a)
Reduced embedment depth
This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
152
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
1 / 2009
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-98/0001, issue 2008-02-12.
All data applies to concrete C 20/25 fck,cube =25 N/mm.
1 / 2009
153
Design resistance
Single anchor, no edge effects
Standard embedment depth
M6
M8
M6
M8
100
100
140
170
210
100
100
100
100
130
160
8,0
10,7
16,7
25,9
35,1
2,8
6,0
8,0
11,9
17,2
23,1
6,7
6,7
11,9
4,2
5,7
8,5
Anchor size
HSA-R
[kN]
3,3
9,6
11,9
24,4
44,0
68,0
5,2
7,0
9,1
11,9
34,4
46,3
HSA-R
7,3
11,3
16,7
7,0
9,1
11,9
[kN]
4,0
M6
M8
M6
M8
100
100
100
140
170
210
100
100
100
100
130
160
[mm]
[mm]
50
50
60
60
65
75
90
100
105
-
125
-
40
-
45
45
65
65
100
100
100
-
115
-
HSA
[kN]
3,3
7,1
7,4
12,2
15,9
21,3
2,8
4,5
6,3
9,5
11,9
15,4
HSA-R
[kN]
3,3
5,9
6,7
9,2
3,7
4,4
6,8
Anchor size
Min. base material
thickness hmin
Min. edge
HSA
distance cmin
HSA-R
[mm]
Tensile NRd
[kN]
2,7
4,0
4,8
8,8
12,6
18,2
1,8
2,4
4,6
7,4
10,1
14,5
HSA-R
[kN]
2,7
4,0
5,5
9,9
2,4
4,6
7,4
M6
M8
M6
M8
100
50
50
100
55
65
140
75
100
170
90
-
210
105
-
100
35
-
100
35
35
6,8
7,1
11,8
15,5
20,9
2,8
4,2
5,7
8,1
11,1
14,3
3,3
5,6
6,1
8,9
3,5
4,0
5,8
7,5
15,6
24,4
35,1
47,0
3,8
6,9
13,1
19,8
37,9
57,8
HSA-R
7,3
8,5
16,7
4,6
6,5
8,9
HSA-R
154
[kN]
[kN]
4,0
1 / 2009
Recommended loads
Single anchor, no edge effects
Standard embedment depth
M6
M8
M6
M8
100
100
140
170
210
100
100
100
100
130
160
Anchor size
5,7
7,6
11,9
18,5
25,1
2,0
4,3
5,7
8,5
12,3
16,5
2,4
4,8
4,8
8,5
3,0
4,1
6,1
6,9
8,5
17,4
31,4
48,6
3,7
5,0
6,5
8,5
24,6
33,1
HSA-R
5,2
8,1
11,9
5,0
6,5
8,5
HSA-R
[kN]
[kN]
2,9
M6
M8
M6
M8
100
100
100
140
170
210
100
100
100
100
130
160
[mm]
[mm]
50
50
60
60
65
75
90
100
105
-
125
-
40
-
45
45
65
65
100
100
100
-
115
-
[kN]
2,4
5,1
5,3
8,7
11,3
15,2
2,0
3,2
4,5
6,8
8,5
11,0
[kN]
2,4
4,2
4,8
6,6
2,6
3,2
4,9
2,8
3,4
6,3
9,0
13,0
1,3
1,7
3,3
5,3
7,2
10,3
HSA-R
2,8
3,9
7,1
1,7
3,3
5,3
Anchor size
Min. base material
thickness hmin
Min. edge
HSA
distance cmin
HSA-R
Tensile Nrec
HSA
HSA-R
[mm]
[kN]
1,9
M6
M8
M6
M8
100
50
50
100
55
65
140
75
100
170
90
-
210
105
-
100
35
-
100
35
35
4,8
5,1
8,4
11,1
14,9
2,0
3,0
4,1
5,8
7,9
10,2
Anchor size
2,4
4,0
4,4
6,3
2,5
2,9
4,2
HSA-R
5,4
11,1
17,4
25,1
33,6
2,7
5,0
9,4
14,1
27,1
41,3
HSA-R
5,2
6,1
11,9
3,3
4,6
6,4
[kN]
[kN]
2,9
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
155
Benefits
- torque-controlled mechanical
expansion allows immediate load
application
- long thread length accommodates
various
- cold formed to prevent breaking if
bent
- raised impact section prevents
thread damage during
installation.
- anchor size is the same as drill bit
size for easy installation.
Concrete
M8
M10
M12
M16
Tensile NRu,m
[kN]
14
14,4
27,8
43,8
Shear VRu,m
[kN]
10,8
15,7
24,6
44,3
M8
M10
M12
M16
Characteristic resistance
Anchor size
Tensile NRk
[kN]
8,4
11,2
17,5
24,5
Shear VRk
[kN]
7,0
11,2
16,1
27,3
M8
M10
M12
M16
Design resistance
Anchor size
Tensile NRd
[kN]
4,8
6,3
8,4
16,2
Shear VRd
[kN]
4,5
7,0
9,9
18,5
156
1 / 2009
Recommended loads
Anchor size
Tensile Nrec
Shear Vrec
a)
a)
M8
M10
M12
M16
[kN]
3,4
4,5
6,0
11,6
[kN]
3,2
5,0
7,1
13,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations.
Materials
Mechanical properties of HSV
Anchor size
Nominal tensile strength
Yield strength
Stressed cross-section
Moment of resistance
Char. bending resistance
fuk
fyk
As
W
M0Rk,s
[N/mm]
[N/mm]
[mm]
[mm]
[Nm]
M8
M10
M12
M16
520
410
36,6
31,2
19
520
410
58,0
62,3
39
520
410
84,3
109,2
68
430
340
157
277,5
143
M8
M10
M12
M16
Material quality
Part
Material
Bolt
Anchor dimensions
Anchor size
tfix,min
[mm]
tfix,max
[mm]
10
20
10
45
dR
[mm]
5,8
7,6
12,2
l1
[mm]
75
90
100
140
l2
[mm]
11,5
15,4
19,1
24,8
dR
l1
l2
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
1 / 2009
M8
M10
M12
TE2 TE16
hammer, torque wrench, blow out pump
M16
157
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
Setting details: depth of drill hole h1 and effective anchorage depth hef
Tinst
hef
h1
M10
M12
M16
do
[mm]
10
12
16
dcut
[mm]
8,45
10,45
12,5
16,5
h1
[mm]
65
70
95
115
df
[mm]
12
14
18
hef
[mm]
48
50
70
84
Torque moment
Tinst
[Nm]
15
30
50
100
Width across
SW
[mm]
13
17
19
24
M8
M10
M12
M16
Setting parameters
Anchor size
Minimum base material thickness
hmin
[mm]
100
120
140
170
Minimum spacing
smin = scr
[mm]
200
200
280
340
cmin = ccr
[mm]
150
150
210
250
158
1 / 2009
1 / 2009
159
Concrete
Solid brick
HLC
HLC-H
Bolt version
with washer
HLC-L
Torx round
head
HLC-SK
Torx Counter
sunk head
HLC-EC
Loop hanger
head, eyebold
closed
HLC-EO
Loop hanger
head, eyebold
open
HLC-T
Ceiling hanger
Benefits
HLC offers various head shapes
and fastening thicknesses.
Fire
resistance
Approvals / certificates
Description
Fire test report
Authority / Laboratory
IBMB, Braunschweig
warringtonfire
160
1 / 2009
Characteristic resistance
Anchor size
6,5
10
12
16
20
Tensile NRk
[kN]
2,1
3,5
4,5
7,2
10,0
13,2
Shear VRk
[kN]
3,2
7,0
8,8
14,4
20,0
20,0
6,5
10
12
16
20
Design resistance
Anchor size
Tensile NRd
[kN]
1,2
2,0
2,5
4,0
5,6
7,4
Tensile NRd
[kN]
1,8
3,9
4,9
8,0
11,1
11,1
6,5
10
12
16
20
[kN]
0,8
1,4
1,8
2,9
4,0
5,3
[kN]
1,3
2,8
3,5
5,7
7,9
7,9
Recommended loads
Anchor size
Tensile Nrec
Shear
a)
Vreca)
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Materials
Material quality
Part
Anchor
1 / 2009
Material
HLC
HLC-EC
HLC-EO
HLC-H
HLC-L
HLC-SK
HLC-T
161
Anchor dimensions
Anchor version
Thread size
hef
[mm]
d
[mm]
l
[mm]
lc
[mm]
tfix
[mm]
30
25
45
40
20
6,5 x 60/40
65
60
40
8 x 40/10
46
40
10
61
55
25
76
70
40
8 x 85/55
91
85
55
10 x 40/5
48
40
10 x 50/15
58
50
15
68
60
25
10 x 80/45
88
80
45
10 x 100/65
108
100
65
12 x 55/15
65
55
15
85
75
35
110
100
60
72
60
10
6,5 x 25/5
6,5 x 40/20
8 x 55/25
8 x 70/40
10 x 60/25
12 x 75/35
16
26
31
33
M5
M6
M8
M10
12 x 100/60
16 x 60/10
16 x 100/50
41
M12
112
100
50
152
140
90
95
80
25
130
115
60
20 x 150/95
165
150
95
6,5 x 45/20
45
16 x 140/90
20 x 80/25
20 x 115/60
6,5 x 65/40
41
16
M16
M5
40
6,5 x 85/60
85
60
8 x 60/25
60
25
8 x 75/40
26
M6
75
40
8 x 90/55
90
55
10 x 45/5
45
10 x 85/45
10 x 105/65
31
M8
10 x 130/95
12 x 55/15
162
65
20
85
105
130
33
M10
80
45
65
95
35
1 / 2009
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
6,5
10
12
16
TE 2 TE 16
hammer, torque wrench, blow out pump
20
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
[mm]
6,5
10
12
16
20
do
[mm]
6,5
(1/4)
10
12
16
20
dcut
[mm]
6,4
8,45
10,45
12,5
16,5
20,55
h1
[mm]
30
40
50
65
75
85
HLC
SW
[mm]
HLC-H
SW
[mm]
10
13
19
24
HLS-SK
Driver
PZ 3
T 30
T 40
T 40
10
12
14
18
21
15
17
df
[mm]
hef
[mm]
16
26
31
33
41
41
Tinst
[Nm]
25
40
50
80
Tinst
[Nm]
2,5
13
20
25
1 / 2009
163
6,5
10
12
16
20
hmin
[mm]
60
70
80
100
100
120
scr
[mm]
60
100
120
130
160
160
[mm]
30
50
60
65
80
80
Recommended loadsa)
Hilti
6,5
10
12
16
[mm]
16
26
31
33
41
Tensile Nrec c)
[kN]
0,3
0,5
0,6
0,7
0,8
Shear Vrec c)
[kN]
0,45
1,0
1,2
1,4
1,6
0,4
0,5
0,6
0,8
0,8
0,65
1,0
1,2
1,6
1,6
Base material
Anchor size
hnom
a)
b)
c)
d)
164
DIN 105/
EN 771-1
fb b) 12 N/mm
DIN 106/
EN 771-2
fb b) 12 N/mm
Tensile Nrec d)
Shear Vrec d)
[kN]
[kN]
Recommended load values for German base materials are based on national regulations.
fb = brick strength
Values only valid for Mz (DIN 105) with brick strength 19 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 11,5cm)
Values only valid for KS (DIN 106) with brick strength 29 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 11,5cm)
1 / 2009
5.5 cm
11 cm
5.5 cm
5.5 cm
11 cm
5.5 cm
5.5 cm
24 cm
1 / 2009
165
Benefits
HAM
Concrete
Solid brick
M8x60
M10x80
M12x90
[kN]
4,0
4,8
5,8
8,7
[kN]
4,6
8,4
13,3
19,3
M6x50
M8x60
M10x80
M12x90
Thread Diameter
[mm]
Tension
Nrec
Shear
Vrec
[mm]
Tension
Nrec
[kN]
Shear
Vrec
[kN]
Materials
Part
HAM Anchor
166
Material
Sleeve
Carbon steel
Hex head
Bolt
Washer
1 / 2009
Anchor dimensions
Anchor version
M6 x 50
hef
[mm]
30
d
[mm]
12
ls
[mm]
30
l1
[mm]
40
l2
[mm]
50
tfix
[mm]
10
M8 x 60
35
14
35
50
60
10
M10 x 80
43
16
43
60
80
20
M12 x 90
55
19
55
70
90
20
Anchor
HAM
Setting
Installation equipment
Anchor size
Rotary hammer
Drill bit
Other tools
M6x50
TE-C3X
12
M8x60
M10x80
TE 2 TE 16
14
16
hammer, torque wrench, blow out pump
M12x90
20
For detailed information on installation see instruction for use given with the package of the product.
[mm]
M6x50
M8x60
M10x80
M12x90
do
[mm]
12
14
16
20
dcut
[mm]
12,5
14,5
16,5
20,55
h1
[mm]
65
80
90
110
SW
[mm]
10
13
17
19
df
[mm]
12
14
hef
[mm]
16
26
31
33
Tinst
[Nm]
10
25
45
75
Tinst
[Nm]
10
20
30
1 / 2009
167
Concrete
Tensile
zone
Small edge
distance
and spacing
Solid brick
Anchor version
Benefits
HUS-HR
Stainless steel
Concrete Screw
Autoclaved
aerated
concrete
Fire
resistance
Corrosion
Resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Fire test report
Fire test report ZTV Tunnel (EBA)
Authority / Laboratory
DIBt, Berlin
DIBt, Berlin
MFPA, Leipzig
a) Data for HUS-HR 6,8,10 and 14 is given in this section according ETA-08/0307 issue 2008-12-12
168
1 / 2009
Cracked concrete
HUS-HR
10
14
10
14
[mm]
30
50
60
30
50
60
a)
6,7
10,0
a)
22,5
30,0
[kN]
[kN]
a)
a)
12,0
16,0
31,5
41,9
Reduced embedment
hnom
[mm]
60
70
70
60
70
70
Tensile NRu,m
[kN]
16,0
21,3
25,2
8,0
12,0
16,0
Shear VRu,m
[kN]
34,7
44,0
50,4
30,9
38,1
36,0
hnom
[mm]
55
80
90
110
55
80
90
110
Tensile NRu,m
[kN]
12,0
21,3
33,3
53,6
6,7
16,0
21,3
33,3
Shear VRu,m
[kN]
22,7
34,7
44,0
102,7
21,7
a) Please refer to resistance table in all load directions for multiple use fastenings
34,7
44,0
76,6
Standard embedment
Characteristic resistance
Non-cracked concrete
Anchor size
Cracked concrete
HUS-HR
10
14
10
14
[mm]
30
50
60
30
50
60
a)
5,0
7,5
a)
16,9
22,5
[kN]
[kN]
a)
a)
9,0
12,0
23,6
31,4
Reduced embedment
(ETA-08/0307)
hnom
[mm]
60
70
70
60
70
70
Tensile NRk
[kN]
12,0
16,0
18,9
6,0
9,0
12,0
Shear VRk
[kN]
26,0
33,0
37,8
23,2
28,6
27,0
hnom
[mm]
55
80
90
110
55
80
90
110
Tensile NRk
[kN]
9,0
16,0
25,0
40,2
5,0
12,0
16,0
25,0
Shear VRk
[kN]
17,0
26,0
33,0
77,0
16,3
a) Please refer to resistance table in all load directions for multiple use fastenings
26,0
33,0
57,4
Standard embedment
(ETA-08/0307)
1 / 2009
169
Design resistance
Non-cracked concrete
Anchor size
Cracked concrete
HUS-HR
10
14
10
14
[mm]
30
50
60
30
50
60
a)
2,8
4,2
a)
11,2
15,0
[kN]
Shear VRd
[kN]
a)
a)
5,0
6,7
15,7
21,0
Reduced embedment
(ETA-08/0307)
hnom
[mm]
60
70
70
60
70
70
Tensile NRd
[kN]
6,7
8,9
10,5
3,3
5,0
6,7
Shear VRd
[kN]
17,3
22,0
25,2
15,5
19,0
18,0
hnom
[mm]
55
80
90
110
55
80
90
110
Tensile NRd
[kN]
4,3
8,9
13,9
22,3
2,4
6,7
8,9
13,9
Shear VRd
[kN]
11,3
17,3
22,0
51,3
10,9
a) Please refer to resistance table in all load directions for multiple use fastenings
17,3
22,0
38,3
Standard embedment
(ETA-08/0307)
Recommended loads
Non-cracked concrete
Anchor size
Cracked concrete
HUS-HR
10
14
10
14
[mm]
30
50
60
30
50
60
2,0
3,0
8,0
10,7
a)
a)
[kN]
[kN]
3,6
4,8
11,2
15,0
Reduced embedment
(ETA-08/0307)
hnom
Tensile Nrec
Shear Vrec
a)
a)
[mm]
60
70
70
60
70
70
[kN]
4,8
6,3
7,5
2,4
3,6
4,8
[kN]
12,4
15,7
18,0
11,0
13,6
12,9
Standard embedment
(ETA-08/0307)
hnom
[mm]
55
80
90
110
55
80
90
110
Tensile Nrec a)
[kN]
3,1
6,3
9,9
16,0
1,7
4,8
6,3
9,9
[kN]
8,1
12,4
15,7
36,7
7,8
12,4
15,7
27,3
Shear Vrec
a)
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
b) Please refer to resistance table in all load directions for multiple use fastenings
170
1 / 2009
Hilti Technical data for multiple use resistance in all load directions, in cracked and noncracked concrete: fc,cube 25 N/mm2
Anchor
hnom
Characteristic
Design
Recommended
[mm]
30
2,0
1,0
0,7
HUS-HR 6
a)
Minimum number
of fixing points
Minimum number
of anchors per fixing point
2 kN
1
3 kN
4
The value for maximum design load of actions per fastening point NSd is valid in general that means all
fastening points are considered in the design of the redundant structural system. The value NSd may be
increased if the failure of one (= most unfavourable) fixing point is taken into account in the design
(serviceability and ultimate limit state) of the structural system e.g. suspended ceiling.
Recommended loadsa)
Hilti
Base material
Germany, Austria, Switzerland
Solid clay brick
Mz12/2,0
a)
b)
c)
d)
HUS-HR 6
HUS-HR 8
HUS-HR 10
[mm]
55
60
70
Tensile Nrec b)
[kN]
0,9
1,0
1,1
Shear Vrec b)
[kN]
1,4
2,0
2,3
0,6
0,6
1,0
0,9
1,1
1,7
0,2
0,2
0,4
0,4
0,4
0,9
Anchor size
DIN 105/
EN 771-1
fb a) 12 N/mm
hnom
DIN 106/
EN 771-2
fb a) 12 N/mm
Tensile Nrec c)
DIN 4165/
EN 771-4
fb a) 6 N/mm
Tensile Nrec d)
Shear Vrec c)
Shear Vrec d)
[kN]
[kN]
[kN]
[kN]
fb = brick strength
Values only valid for Mz (DIN 105) with brick strength 24 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 11,5cm)
Values only valid for KS (DIN 106) with brick strength 29,4 N/mm, density 2,0 kg/dm, minimum brick size
NF (24,0cm x 11,5cm x 11,5cm)
Values only valid for KS (DIN 4165) with brick strength 7,6 N/mm, density 0,04 kg/dm
1 / 2009
171
Materials
Mechanical properties
Anchor size
Nominal tensile strength fuk [N/mm]
HUS-HR 6
HUS-HR 8
HUS-HR 10
HUS-HR 14
1040
870
950
820
Stressed cross-section As
[mm]
23
39
55
125
Moment of resistance W
[mm]
15,5
34,4
58,2
196,4
19,3
35,9
66,3
193,2
Part
Stainless steel hexagonal
head concrete screw
172
Material
Stainless steel (grade A4)
1 / 2009
Anchor dimensions
Dimensions
Anchor version
ls
[mm]
ds
[mm]
dk
[mm]
HUS-HR 6
35 70
7,5
5,4
HUS-HR 8
55 105
10,1
7,1
HUS-HR 10
65 130
12,3
8,4
HUS-HR 14
80 135
16,5
12,6
Setting
Recommended installation equipment
Anchor size
Rotary hammer
drill bit
Socket wrench insert
Impact screw driver
HUS-HR 6
Hilti TE 6
TE-C3X 6/17
S-NSD 13 (L)
Hilti SIW 144 or 121
Hilti TKI 2500
HUS-HR 8
Hilti TE 6
TE-C3X 8/17
S-NSD 13 (L)
HUS-HR 10
Hilti TE 16
TE-C3X 10/22
S-NSD 15 (L)
HUS-HR 14
Hilti -TE 16
TE-C3X 14/22
S-NSD 21
Hilti SI 100
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
173
Setting details: depth of drill hole h1 and effective anchorage depth hef
Setting details
Anchor version
HUS-HR
30
8
55
50
60
10
80
60
70
14
90
70
110
hnom
[mm]
do
[mm]
10
14
dcut
[mm]
6,4
8,45
10,45
14,5
h1
[mm]
df
[mm]
hef
[mm]
tfix
[mm]
Concrete
Tinst
Solid m. Mz 12
Solid m. KS 12
40
65
60
70
90
70
12
23
45
38
47
[Nm]
20
Tinst
[Nm]
b)
Tinst
[Nm]
- b)
80
100
80
14
64
46
120
18
54
71
52
86
ls hnom
35
a)
- a)
45
45
45
65
65
10
b)
16
16
20
20
b)
- b)
10
- b)
16
16
20
20
- b)
- b)
Aerated conc.
Tinst
[Nm]
- b)
4
- b)
a) Hilti recommends machine setting only in concrete
b) Hilti does not recommend this setting process for this application.
10
10
- b)
- b)
Max.
installation
torque
174
a)
1 / 2009
HUS-HR 6
HUS-HR 8
HUS-HR 10
HUS-HR 14
Nominal embedment
hnom
depth
[mm]
30
55
50
60
80
60
70
80
70
110
Minimum base
hmin
material thickness
non-cracked concrete
[mm]
100
100
100
100
120
120
120
140
140
160
Minimum spacing
smin
[mm]
40
40
45
45
50
50
50
50
50
60
cmin
[mm]
40
40
45
45
50
50
50
50
50
60
scr,N =
scr,sp
[mm]
69
135
114
141
192
166
194
256
187
310
ccr,N =
ccr,sp
[mm]
35
68
57
71
96
83
97
128
94
155
Minimum edge
distance
Critical spacing for
concrete cone and
splitting failure
Critical edge distance
for concrete cone
and splitting failure
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced (see system design resistance).
Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked
concrete only the critical spacing and critical edge distance for concrete cone failure are decisive.
1 / 2009
175
TENSION loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
HUS-HR 6
HUS-HR 8
HUS-HR 10
HUS-HR 14
17,0
24,3
37,6
73,0
[kN]
Cracked concrete
10
14
10
14
[mm]
30
50
60
30
50
60
Tensile NRd
[kN]
5,0
6,7
2,8
4,2
hnom
[mm]
60
70
70
60
70
70
Tensile NRd
[kN]
6,7
8,9
10,5
3,3
5,0
6,7
hnom
[mm]
55
80
90
110
55
80
90
110
Tensile NRd
[kN]
4,3
8,9
13,9
22,3
2,4
6,7
8,9
13,9
Reduced embedment
Standard embedment
176
1 / 2009
Cracked concrete
10
14
10
14
[mm]
30
50
60
30
50
60
[kN]
6,6
8,7
4,7
6,2
[mm]
60
70
70
60
70
70
[kN]
9,0
11,1
10,5
6,4
7,9
7,5
[mm]
55
80
90
110
55
80
90
110
N Rd,c
[kN]
7,2
14,3
16,8
22,3
a) Splitting resistance must only be considered for non-cracked concrete
5,2
10,2
12,0
16,0
Anchor size
Extra reduced embedment
(Hilti Tech Data)
hnom
0
Rd,c
Reduced embedment
hnom
0
Rd,c
Standard embedment
hnom
0
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
0,5 a)
fB =
(fck,cube/25N/mm)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
1 / 2009
177
2/3
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
Influence of reinforcement
Anchor size
HUS-HR 6
HUS-HR 8
HUS-HR 10
HUS-HR 14
hnom
[mm]
30
55
50
60
80
60
70
80
70
110
hef
[mm]
23
45
38
47
64
46
54
71
52
86
0,62 0,73 0,69 0,74 0,82 0,73 0,77 0,86 0,76 0,93
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
SHEAR loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
HUS-HR 6
HUS-HR 8
HUS-HR 10
HUS-HR 14
[kN]
11,3
17,3
22,0
VRd,s
[kN]
17,3
22,0
36,7
VRd,s
[kN]
11,3
17,3
22,0
51,3
Extra reduced
embedment
VRd,s
Reduced
embedment
Standard
embedment
178
1 / 2009
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Anchor size
Cracked concrete
10
14
10
14
[mm]
30
60
60
30
60
60
[kN]
15,7
21,0
11,2
15,0
[mm]
60
70
70
60
70
70
[kN]
21,7
26,7
25,2
15,5
19,0
18,0
[mm]
55
80
90
110
55
80
90
110
[kN]
15,2
34,4
40,2
53,6
10,9
24,6
28,7
38,3
HUS-HR
Rd,cp
Reduced embedment
hnom
V
Rd,cp
Standard embedment
hnom
V
Rd,cp
Cracked concrete
HUS-HR
10
14
10
14
[mm]
30
60
60
30
60
60
[kN]
2,3
4,6
1,7
3,3
[mm]
60
70
70
60
70
70
[kN]
1,9
2,8
3,8
1,4
2,0
2,7
[mm]
55
80
90
110
55
80
90
110
[kN]
2,3
2,7
5,9
9,0
1,7
1,9
4,2
6,4
Rd,c
Reduced embedment
hnom
V
Rd,c
Standard embedment
hnom
V
Rd,c
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,5 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
179
s/scr,N
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
Influence of reinforcement
Anchor size
HUS-HR 6
HUS-HR 8
HUS-HR 10
HUS-HR 14
hnom
[mm]
30
55
50
60
80
60
70
80
70
110
hef
[mm]
23
45
38
47
64
46
54
71
52
86
0,62 0,73 0,69 0,74 0,82 0,73 0,77 0,86 0,76 0,93
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,00
1,07
1,14
1,23
1,35
1,50
1,71
2,00
180
-1/3
{h/(1,5 c)}
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
2,15
1,71
1,49
1,36
1,26
1,19
1,13
1,08
1,04
1 / 2009
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-08/0307, issue 2008-12-12.
All data applies to concrete C 20/25 fck,cube =25 N/mm. Hilti technical data for the extra reduced embedment
depth is not part of the approval.
1 / 2009
181
Design resistance
Single anchor, no edge effects (c ccr), shear without lever arm
Non-cracked concrete
Cracked concrete
Anchor size
HUS-HR
10
14
10
14
[mm]
30
60
60
30
60
60
80
100
120
80
100
120
Tensile NRd
[kN]
5,0
6,7
2,8
4,2
Shear VRd
[kN]
15,7
21,0
11,2
15,0
[mm]
60
70
70
60
70
70
100
120
140
100
120
140
Reduced embedment
hnom
Tensile NRd
[kN]
6,7
8,9
10,5
3,3
5,0
6,7
Shear VRd
[kN]
17,3
22,0
25,2
15,5
19,0
18,0
[mm]
55
80
90
110
55
80
90
110
100
120
140
160
100
120
140
160
Standard embedment
hnom
182
Tensile NRd
[kN]
4,3
8,9
13,9
22,3
2,4
6,7
8,9
13,9
Shear VRd
[kN]
11,3
17,3
22,0
51,3
10,9
17,3
22,0
38,3
1 / 2009
Single anchor, min. edge distance (c = cmin), shear without lever arm
Non-cracked concrete
Cracked concrete
Anchor size
HUS-HR
10
14
10
14
[mm]
30
60
60
30
60
60
80
40
100
45
120
50
80
40
100
45
120
50
Tensile NRd
[kN]
5,0
6,7
2,8
4,2
Shear VRd
[kN]
2,3
4,6
1,7
3,3
Reduced embedment
[mm]
60
70
70
60
70
70
100
45
120
50
140
50
100
45
120
50
140
50
hnom
Tensile NRd
[kN]
6,6
7,2
6,9
3,3
5,0
4,9
Shear VRd
[kN]
1,9
2,8
3,8
1,4
2,0
2,7
Standard embedment
hnom
[mm]
1 / 2009
55
80
90
110
55
80
90
110
100
40
120
50
140
50
160
60
100
40
120
50
140
50
160
60
Tensile NRd
[kN]
4,3
8,9
9,5
12,6
2,4
6,7
6,8
9,0
Shear VRd
[kN]
2,3
2,7
5,9
9,0
1,7
1,9
4,2
6,4
183
Double anchor, no edge effects (c ccr), min. spacing (s = smin), shear without lever arm
(load values are valid for one anchor)
Non-cracked concrete
Cracked concrete
Anchor size
HUS-HR
10
14
10
14
30
60
60
30
60
60
80
40
100
45
120
50
80
40
100
45
120
50
hnom
Tensile NRd
[kN]
4,6
5,7
2,8
4,1
Shear VRd
[kN]
9,1
11,4
6,5
8,1
[mm]
60
70
70
60
70
70
100
45
120
50
140
50
100
45
120
50
140
50
Reduced embedment
hnom
Tensile NRd
[kN]
6,0
7,0
6,7
3,3
5,0
4,8
Shear VRd
[kN]
11,9
14,0
13,3
8,5
10,0
9,5
[mm]
55
80
90
110
55
80
90
110
100
40
120
50
140
50
160
60
100
40
120
50
140
50
160
60
Standard embedment
hnom
184
Tensile NRd
[kN]
4,3
8,9
10,0
13,3
2,4
6,5
7,2
9,5
Shear VRd
[kN]
7,0
17,3
20,0
26,7
5,0
12,9
14,3
19,0
1 / 2009
Recommended loads
Single anchor, no edge effects (c ccr), shear without lever arm
Non-cracked concrete
Cracked concrete
Anchor size
HUS-HR
10
14
10
14
[mm]
30
60
60
30
60
60
80
100
120
80
100
120
Tensile Nrec
[kN]
3,6
4,8
2,0
3,0
Shear Vrec
[kN]
11,2
15,0
8,0
10,7
[mm]
60
70
70
60
70
70
100
120
140
100
120
140
Reduced embedment
hnom
Tensile Nrec
[kN]
4,8
6,3
7,5
2,4
3,6
4,8
Shear Vrec
[kN]
12,4
15,7
18,0
11,0
13,6
12,9
[mm]
55
80
90
110
55
80
90
110
100
120
140
160
100
120
140
160
Standard embedment
hnom
1 / 2009
Tensile Nrec
[kN]
3,1
6,3
9,9
16,0
1,7
4,8
6,3
9,9
Shear Vrec
[kN]
8,1
12,4
15,7
36,7
7,8
12,4
15,7
27,3
185
Single anchor, min. edge distance (c = cmin), shear without lever arm
Non-cracked concrete
Cracked concrete
Anchor size
HUS-HR
10
14
10
14
[mm]
30
60
60
30
60
60
80
40
100
45
120
50
80
40
100
45
120
50
Tensile Nrec
[kN]
3,6
4,4
2,0
3,0
Shear Vrec
[kN]
1,7
3,3
1,2
2,4
Reduced embedment
[mm]
60
70
70
60
70
70
100
45
120
50
140
50
100
45
120
50
140
50
hnom
Tensile Nrec
[kN]
4,7
5,1
4,9
2,4
3,6
3,5
Shear Vrec
[kN]
1,4
2,0
2,7
1,0
1,4
2,0
Standard embedment
hnom
[mm]
186
55
80
90
110
55
80
90
110
100
40
120
50
140
50
160
60
100
40
120
50
140
50
160
60
Tensile Nrec
[kN]
3,1
6,3
6,8
9,0
1,7
4,8
4,9
6,5
Shear Vrec
[kN]
1,7
1,9
4,2
6,4
1,2
1,4
3,0
4,6
1 / 2009
Double anchor, no edge effects (c ccr), min. spacing (s = smin), shear without lever arm
(load values are valid for one anchor)
Non-cracked concrete
Cracked concrete
Anchor size
HUS-HR
10
14
10
14
30
60
60
30
60
60
80
40
100
45
120
50
80
40
100
45
120
50
hnom
Tensile Nrec
[kN]
3,3
4,1
2,0
2,9
Shear Vrec
[kN]
6,5
8,1
4,7
5,8
[mm]
60
70
70
60
70
70
100
45
120
50
140
50
100
45
120
50
140
50
Reduced embedment
hnom
Tensile Nrec
[kN]
4,3
5,0
4,8
2,4
3,6
3,4
Shear Vrec
[kN]
8,5
10,0
9,5
6,1
7,1
6,8
[mm]
55
80
90
110
55
80
90
110
100
40
120
50
140
50
160
60
100
40
120
50
140
50
160
60
Standard embedment
hnom
[kN]
3,1
6,3
7,2
9,5
1,7
4,6
5,1
6,8
Shear Vrec
[kN]
5,0
12,4
14,3
19,0
3,6
9,2
10,2
13,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
187
Concrete
Tensile
zone
Small edge
distance
and spacing
Anchor version
Benefits
HUS-H
Carbon steel
Concrete Screw
Autoclaved
aerated
concrete
Solid brick
Fire
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
IBMB, Brunswick
warringtonfire
a) Data for HUS-H 10,5 and HUS-H 12,5 given in this section according ETA-06/0159 issue 2006-06-26
Cracked concrete
Hilti
ETA
Hilti
10,5
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
60
70
50
60
110
90
70
60
70
50
60
90
hnom
[mm]
Tensile NRu,m
[kN]
Shear VRu,m
[kN]
19,9 27,1 19,9 27,1 73,4 71,3 61,1 19,9 27,1 19,9 27,1 71,3
188
7,6
12,3 34,7
1 / 2009
Characteristic resistance
Cracked concrete
Non-cracked concrete
ETA
Anchor size
Hilti
ETA
Hilti
10,5
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
60
110
90
70
60
70
50
60
90
5,0
7,5
3,9
6,4
14,3
hnom
[mm]
60
70
50
Tensile NRk
[kN]
9,0
12,0
8,4
Shear VRk
[kN]
15,4 21,6 15,4 21,6 51,2 51,2 35,6 15,4 21,6 15,4 21,0 39,5
Design resistance
Non-cracked concrete
ETA
Anchor size
Cracked concrete
Hilti
ETA
Hilti
10,5
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
90
70
60
70
50
60
90
2,8
4,2
2,2
3,6
9,5
hnom
[mm]
60
70
50
60
110
Tensile NRd
[kN]
5,0
6,7
4,7
6,7
Shear VRd
[kN]
10,3 14,4 10,3 14,4 34,1 34,1 23,8 10,3 14,4 10,3 14,0 26,3
Recommended loads
Non-cracked concrete
ETA
Tensile Nrec
Shear Vrec
a)
a)
ETA
Hilti
10,5
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
[mm]
60
70
50
60
110
90
70
60
70
50
60
90
[kN]
3,6
4,8
3,3
4,8
20,0 13,2
8,5
2,0
3,0
1,6
2,6
6,8
[kN]
7,3
10,3
7,3
7,3
10,3
7,3
10,0 18,8
Anchor size
hnom
Cracked concrete
Hilti
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
ETA: Data according ETA-06/0159 issue 2006-06-26
1 / 2009
189
Recommended loadsa)
Hilti
Base material
Anchor size
hnom
Tensile Nrec c)
a)
b)
c)
d)
e)
190
DIN 105/
EN 771-1
fb b) 12 N/mm
Shear Vrec
c)
DIN 106/
EN 771-2
fb b) 12 N/mm
Tensile Nrec d)
DIN 4165/
EN 771-4
fb b) 6 N/mm
Tensile Nrec e)
Shear Vrec d)
Shear Vrec e)
10,5
12,5
[mm]
60
70
[kN]
1,0
1,1
[kN]
2,0
2,3
0,6
1,0
1,1
1,7
0,2
0,4
0,4
0,9
[kN]
[kN]
[kN]
[kN]
Recommended load values for German base materials are based on national regulations.
fb = brick strength
Values only valid for Mz (DIN 105) with brick strength 24 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 11,5cm)
Values only valid for KS (DIN 106) with brick strength 29,4 N/mm, density 2,0 kg/dm, minimum brick size
NF (24,0cm x 11,5cm x 11,5cm)
Values only valid for KS (DIN 4165) with brick strength 7,6 N/mm, density 0,04 kg/dm
1 / 2009
Recommended loads
Non-cracked concrete
Hilti
16,5
16,5
16,5
[mm]
110
90
70
[kN]
7,5
5,5
3,5
Anchor size
hnom
Tensile Nrec
a)
a)
Shear Vrec
[kN]
16,5
14,0
11,5
a) Values serve as a reference, onsite testing is recommended to determine actual loading potential of the anchors
1 / 2009
191
Materials
Mechanical properties
Anchor size
HUS-H 10,5
HUS-H 12,5
HUS-H 16,5
1000
1000
770
[N/mm]
900
900
700
Stressed cross-section As
[mm]
38,5
54,1
143,1
Moment of resistance W
[mm]
33,7
56,1
191,7
40,4
67,4
179,3
Material quality
Part
Carbon steel hexagonal head
concrete screw
Material
steel according DIN EN 10263-4, 1.5523, galvanised to min. 5 m
Anchor dimensions
Dimensions
Anchor version
ls, min
[mm]
ds
[mm]
d
[mm]
HUS-H 10,5
55
9,75
7,1
HUS-H 12,5
65
12,2
8,4
HUS-H 16,5
80
16,5
12,6
Setting
Recommended installation equipment
Anchor size
Rotary hammer
drill bit
Socket wrench insert
Impact screw driver
192
HUS-H 10,5
HUS-H 12,5
HUS-H 16.5
TE 6
TE-C3X 8/17
S-NSD 13 (L)
SI 100
TE 6
TE-C3X 10/22
S-NSD 15 (L)
SI 100
TE 16
TE-C3X 14/22
S-NSD 21
SI 100
1 / 2009
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
Setting details: depth of drill hole h1 and effective anchorage depth hef
1 / 2009
193
Setting details
Anchor version
HUS-H
10,5
10,5
12,5
12,5
16,5
16,5
16,5
hnom
[mm]
60
50
70
60
110
90
70
do
[mm]
10
10
14
14
14
dcut
[mm]
8,45
8,45
10,45
10,45
14,5
14,5
14,5
h1
[mm]
70
60
80
70
120
100
80
df
[mm]
12
12
14
14
18
18
18
hef
[mm]
45
36
53
44
90
67
50
tfix
[mm]
ls - 60
ls - 50
ls - 70
ls - 60
ls - 110
ls - 90
ls - 70
Concrete
Tinst
[Nm]
35
35
45
45
65
65
65
Solid m. Mz 12
Tinst
[Nm]
10
Solid m. KS 12
Tinst
[Nm]
16
16
Aerated conc.
Tinst
[Nm]
10
10
Max.
installation
torque
10,5
10,5
12,5
12,5
16,5
16,5
16,5
[mm]
60
50
70
60
110
90
70
hmin
[mm]
110
100
130
110
210
170
130
hmin
[mm]
100
100
110
110
170
smin
[mm]
55
55
65
65
80
80
80
cmin
[mm]
55
55
65
65
60
60
60
scr,N
[mm]
135
108
159
132
270
201
150
scr,sp
[mm]
ccr,N
[mm]
67,5
54
79,5
66
135
100,5
75
Nominal embedment
hnom
depth
Minimum base
material thickness
non-cracked concrete
Minimum base
material thickness
cracked concrete
Minimum spacing
Minimum edge
distance
Critical spacing for
concrete cone failure
Critical spacing for
splitting failure
Critical edge distance
for concrete cone
failure
Critical edge distance
for splitting failure
ccr,sp
[mm]
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked
concrete only the critical spacing and critical edge distance for concrete cone failure are decisive.
194
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
Hilti
HUS-H 10,5
HUS-H 12,5
HUS-H 16,5
27,5
38,6
67,5
[kN]
Tensile N
Rd
Hilti
Hilti
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
[mm]
60
70
50
60
110
90
70
60
70
50
60
90
[kN]
5,0
6,7
4,7
6,7
2,8
4,2
2,2
3,6
9,5
ETA
10,5
Anchor size
hnom
Cracked concrete
195
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,sp fre,N
Cracked concrete
Non-cracked concrete
ETA
Anchor size
hnom
[mm]
Hilti
ETA
Hilti
10,5
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
60
70
50
60
110
90
70
60
70
50
60
90
6,0
7,7
4,3
5,8
13,2
N Rd,c
[kN]
8,5 10,8 6,0 8,2 28,7 18,4 11,9
a) Splitting resistance must only be considered for non-cracked concrete
ETA: Data according ETA-06/0159 issue 2006-06-26
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,4 a)
1
1,08
1,17
1,27
1,32
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,37
1,42
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
196
2/3
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
1 / 2009
Influence of reinforcement
Anchor size
HUS-H 10,5
hnom
[mm]
60
hef
[mm]
45
HUS-H 12,5
50
70
36
a)
53
a)
HUS-H 16,5
60
110
90
90
67
44
a)
a)
a)
0,73
0,68
0,77
0,72
0,95
0,84 a)
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
Hilti
HUS-H 10,5
HUS-H 12,5
HUS-H 16,5
10,3
14,4
36,7
[kN]
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Cracked concrete
ETA
Anchor size
hnom
[mm]
V0Rd,cp
[kN]
Hilti
ETA
10,5
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
60
70
50
60
110
90
70
60
70
50
60
90
20,3 14,5 25,9 19,6 57,4 36,9 23,8 20,3 14,5 25,9 19,6 36,9
Hilti
Cracked concrete
Hilti
ETA
Hilti
10,5
12,5
10,5
12,5
16,5
16,5
16,5
10,5
12,5
10,5
12,5
16,5
hnom
[mm]
60
70
50
60
110
90
70
60
70
50
60
90
[kN]
2,5
1,7
3,6
2,6
9,7
5,9
3,6
1,8
1,2
2,6
1,9
7,0
Rd,c
1 / 2009
197
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,4 a)
1
1,08
1,17
1,27
1,32
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,37
1,42
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
s/scr,N
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
Influence of reinforcement
Anchor size
HUS-H 10,5
HUS-H 12,5
HUS-H 16,5
hnom
[mm]
60
50
70
60
110
90
hef
[mm]
45
36
53
44
90
67
0,73
0,68
0,77
0,72
0,95
0,84
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,00
1,07
1,14
1,23
1,35
1,50
1,71
2,00
198
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
1 / 2009
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-02/0042, issue 2008-01-10.
All data applies to concrete C 20/25 fck,cube =25 N/mm.
1 / 2009
199
Design resistance
Single anchor, no edge effects
Non-cracked concrete
Anchor size
10,5
12,5
Cracked concrete
10,5
12,5
60
70
60
70
110
130
100
110
[kN]
5,0
6,7
2,8
4,2
Shear VRd,
[kN]
without lever arm
10,3
14,4
10,3
14,4
hnom
[mm]
Cracked concrete
Anchor size
10,5
12,5
10,5
12,5
60
70
60
70
110
55
130
65
100
40
110
50
[kN]
5,0
6,7
4,2
3,6
Shear VRd,
[kN]
without lever arm
2,5
3,6
1,8
2,6
hnom
[mm]
Cracked concrete
Anchor size
10,5
12,5
10,5
12,5
60
70
60
70
110
55
130
65
100
50
110
50
[kN]
5,0
6,7
4,1
3,6
Shear VRd,
[kN]
without lever arm
10,3
14,2
8,3
10,1
hnom
[mm]
200
1 / 2009
Recommended loads
Single anchor, no edge effects
Non-cracked concrete
Anchor size
10,5
12,5
Cracked concrete
10,5
12,5
60
70
60
70
110
130
100
110
[kN]
3,6
4,8
2,0
3,0
Shear Vrec,
[kN]
without lever arm
7,3
10,3
7,3
10,3
hnom
[mm]
Cracked concrete
Anchor size
10,5
12,5
10,5
12,5
60
70
60
70
110
55
130
65
100
40
110
50
[kN]
3,6
4,8
3,0
2,6
Shear Vrec,
[kN]
without lever arm
1,8
2,6
1,3
1,8
hnom
[mm]
Cracked concrete
Anchor size
10,5
12,5
10,5
12,5
60
70
60
70
110
55
130
65
100
50
110
50
[kN]
3,6
4,8
3,0
2,6
Shear Vrec,
[kN]
without lever arm
7,3
10,1
5,9
7,2
hnom
[mm]
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
201
Carbon
steel
Concrete
Screw
HUS-H 7,5
HUS-A 7,5
Redundant
fastening
Concrete
Solid brick
Hollow brick
Autoclaved
aerated
concrete
Fire
resistance
Benefits
- Quick and easy setting
- Low expansion forces in base
materials
- Through fastening
- Removable
- Forged-on washer and hexagon
head with no protruding thread
Small edge
distance
and spacing
Approvals / certificates
Description
Allgemeine bauaufsichtliche
Zulassung (national approval in
a)
Germany)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
Z-21.1-1710 / 2007-07-19
IBMB, Braunschweig
warringtonfire
UB 3574/5146 / 2006-05-20
WF 166402 / 2007-10-26
a) All data given in this section for HUS 7,5, HUS-H 7,5 and HUS-A 7,5 according Z-21.1-1710, issue 2007-07-19.
202
KS 12 solid lime block, compressive strength 12N/mm2, bulk density 2,0N/mm2, format
240/175/113 mm (length/width/height)
The core/material ratio in bricks and solid sand lime blocks may not exceed 15% of a bed oint
area. The brim area around holes must be at least 70mm
1 / 2009
Other Limits:
o
Applied loads to individual bricks/blocks without compression may not exceed 1.0 kN
Applied loads to individual bricks/blocks with compression may not exceed 1.4 kN
Data applies only to bricks/blocks, there is no test data available for loads in mortar joints. Hilti
recommends at least a 50% load reduction or on site testing, if the location of the anchor in relation
to the joint (see drawing) can not be specified because of wall plaster or insulation.
Plaster, gravelling, lining or levelling courses are regarded as non-bearing and may not be taken
into account for calculation of embedment depth.
Recommended loads
Noncracked
concrete
C20/25
KS sand
Lime
Block a)
Hlz 0.8/12
Hollow
Brick a)
PB2/PB4 b)
PB6
HUS 7,5
HUS 7,5
HUS 7,5
HUS 7,5
HUS 7,5
HUS 7,5
[mm]
34
44
44
64
64
64
c 60 mm
[kN]
1,0
0,2
1,0
0,1
0,2
0,2
c 60 mm
[kN]
1,6
0,4
1,1
0,4
0,3
0,6
Anchor size
hnom
Tensile Nrec
Shear Vrec
c)
c)
Aerated concrete
MZ 20
solid brick
a)
c)
Shear Vrec
c 30 mm
[kN]
0,5
0,3
0,4
0,2
0,1
0,2
a) Holes must be drilled using rotary action only (no hammering action)
b) No anchor hole drilling required in PB2/PB4 gas aerated concrete
c) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Materials
Mechanical properties
Anchor size
HUS 7,5
HUS-H 7,5
HUS-A 7,5
HUS-S 7,5
1000
1000
1000
1000
[N/mm]
900
900
900
900
Stressed cross-section As
[mm]
5,2
5,2
5,2
5,2
Moment of resistance W
[mm]
13,8
13,8
13,8
13,8
16,6
16,6
16,6
16,6
Material quality
Part
Screw anchor
1 / 2009
Material
Carbon Steel, galvanised to min. 5 m
203
Anchor dimensions
Dimensions
Anchor version
ls
[mm]
dk
[mm]
d
[mm]
dG
[mm]
lG
[mm]
HUS 7,5
35..220
7,5
HUS-H 7,5
35..120
7,5
HUS-S 7,5
100..220
7,5
M8
18
M10
21
45
65
45
65
5,3
7,5
Setting
Recommended installation equipment
Anchor size
Rotary hammer
Drill bit
Recommended Setting
Tool
Accessories
204
HUS 7,5
HUS-H 7,5
HUS-A 7,5
HUS-S 7,5
TE 6 / TE 7
TE-C3X 6/17
SID/SIW 121, SID/SIW 144, TKI 2500
S-B TXI 40 bit
S-NSD 13 1/2
socket or S-B
TXI 40 bit
S-NS 13 L Socket
1 / 2009
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
205
Setting details: depth of drill hole h1 and effective anchorage depth hef
Setting details
Anchor version
HUS-H
C20/25
Concrete
MZ 20
Brick/ KS
12 Block
Hollow
Brick
Aerated Concrete
PB2/PB4
PB6
hnom
[mm]
34
44
64
64
64
do
[mm]
dcut
[mm]
6,4
6,4
6,4
6,4
50
b)
a)
b)
70
ls - 70
ls - 60
ls - 110
h1
[mm]
df
[mm]
df
[mm]
tfix
[mm]
50
8,5
6,2
ls - 60
ls - 50
206
70
1 / 2009
1 / 2009
Distance to free edge free edge to solid masonry (Mz and KS) units 200 mm
Distance to free edge free edge to solid masonry (HLz and autoclaved aerated gas concrete) units 170
mm
The minimum distance to horizontal and vertical mortar joint (cmin) is stated in the recommended load
table.
Data applies only to bricks/blocks, there is no test data available for loads in mortar joints. Hilti
recommends at least a 50% load reduction or on site testing, if the location of the anchor in relation to the
joint (see drawing) can not be specified because of wall plaster or insulation.
Minimum anchor spacing (smin) in one brick/block is 2*cmin
207
Benefits
HKD-S(R)
Carbon steel,
stainless steel with
lip
HKD-E(R)
Carbon steel,
stainless steel
without lip
Concrete
Fire
resistance
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
Authority / Laboratory
No. / date of issue
European technical approval a)
DIBt, Berlin
ETA-02/0032 / 2007-10-10
Fire test report
IBMB, Braunschweig
UB 3027/0274-4 / 1994-06-30
Fire test report
IBMB, Braunschweig
Suppl. 133/00/2000-10-04
Assessment report (fire)
warringtonfire
WF 166402 / 2007-10-26
a) All data given in this section for HKD-S(R) and HKD-E(R), according ETA-02/0032, issue 2007-10-10.
208
1 / 2009
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
Tensile NRu,m
HKD-S, HKD-E
[kN]
8,2
10,6
10,8
16,6
10,8
16,6
23,3
34,5
47,1
HKD-SR, HKD-ER
[kN]
8,2
10,8
16,6
23,3
34,5
47,1
HKD-S, HKD-E
[kN]
6,5
6,5
9,1
9,1
9,6
10,4
18,3
28,5
45,1
HKD-SR, HKD-ER
[kN]
8,3
10,9
13,7
24,3
41,7
66,3
Shear VRu,m
Characteristic resistance
Hilti
tech
data
Anchor size
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
Tensile NRk
HKD-S, HKD-E
[kN]
6,3
8,3
8,3
8,3
9,0
12,8
17,8
26,4
36,1
HKD-SR, HKD-ER
[kN]
6,3
8,3
12,8
17,8
26,4
36,1
HKD-S, HKD-E
[kN]
5,0
5,0
7,0
7,4
7,0
8,0
14,1
21,9
34,7
HKD-SR, HKD-ER
[kN]
6,2
8,4
10,5
18,7
32,1
51,0
Shear VRk
Design resistance
Hilti
tech
data
Anchor size
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
4,6
5,0
7,1
9,9
17,6
24,0
7,1
9,9
17,6
24,0
6,4
11,3
17,5
27,8
6,9
12,3
21,1
33,6
Tensile NRd
HKD-S, HKD-E
[kN]
3,0
HKD-SR, HKD-ER
[kN]
3,0
HKD-S, HKD-E
[kN]
3,0
HKD-SR, HKD-ER
[kN]
4,1
4,6
4,6
4,6
Shear VRd
1 / 2009
3,0
5,5
5,5
5,9
5,5
209
Recommended loads
Hilti
tech
data
Anchor size
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
Tensile Nrec a)
HKD-S, HKD-E
[kN]
2,1
3,3
3,3
3,3
3,6
5,1
7,1
12,6
17,2
HKD-SR, HKD-ER
[kN]
2,1
3,3
5,1
7,1
12,6
17,2
HKD-S, HKD-E
[kN]
2,1
2,1
3,9
4,2
3,9
4,6
8,1
12,5
19,8
HKD-SR, HKD-ER
[kN]
2,9
3,9
4,9
8,8
15,1
24,0
Shear Vrec
a)
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Materials
Mechanical properties of HKD-S, HKS-E, HKD-SR and HKD-ER
Anchor size
Nominal
tensile
strength fuk
Yield strength
fyk
M6
M8
M10
M12
M16
M20
HKD-S
HKD-E
[N/mm]
560
560
510
510
460
460
HKD-SR
HKD-ER
[N/mm]
540
540
540
540
540
540
HKD-S
HKD-E
[N/mm]
440
440
410
410
375
375
HKD-SR
HKD-ER
[N/mm]
355
355
355
355
355
355
[mm]
20,9
26,1
58,7
102,8
163,8
[mm]
50
79
264
602
1191
Stressed crosssection As
Moment of
resistance W
a) hnom = 30 mm
b) hnom = 40 mm
28,8a)
31,6b)
110a)
120b)
Material quality
Part
Anchor Body
Tapered expansion
plug
210
Material
HKD-S
HKD-E
HKD-SR
HKD-ER
HKD-S
HKD-E
HKD-SR
HKD-ER
EN 10088-3
EN 10088-3
1 / 2009
Anchor dimensions
Anchor version
1 / 2009
Thread
size
M6x25
M6x30
M8x30
M10x30
M8x40
M10x40
M12x50
M16x65
M20x80
M6x25
M8x30
M10x40
M12x50
M16x65
M20x80
hef
[mm]
25
30
30
30
40
40
50
65
80
25
30
40
50
65
80
d1
[mm]
d2
[mm]
d3
[mm]
d4
[mm]
d5
[mm
l1
[mm]
8
9,95
11,8
9,95
11,95
14,9
19,8
24,8
5
8,2
-
3,9
7,55
-
6,5
6,5
8,2
10,3
13,8
16,5
5,8
5,8
7,1
9,3
12,9
15,5
15
12
12
12
16
20
29
30
9,95
11,95
14,9
19,8
24,8
6,5
8,2
10,3
13,8
17,5
5,3
7,1
9,3
12,9
16,4
12
16
20
29
30
211
Setting
Installation equipment
Anchor size
Rotary hammer
Machine setting tool
Hand Setting tool
Other tools
M6x25/
30
HSD-M
HSD-G
M6x25/
30
TE 16
TE 40 70
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
Setting details: depth of drill hole h1 and effective anchorage depth hef
M6
x30
M8x
30
M10
x30
M8x
40
M10
x40
M12
x50
M16
x65
M20
x80
do
[mm]
10
12
10
12
15
20
25
dcut
[mm]
8,45
8,45
10,45
12,5
10,45
12,5
15,5
20,55
25,55
h1
[mm]
27
32
33
33
43
43
54
70
85
ls,min
[mm]
7,5
7,5
9,5
12
9,5
11,5
14
18
23
ls,max
[mm]
12,5
12,5
14,5
12
15
18
22
28
34
df
[mm]
12
12
14
18
22
hef
[mm]
25
30
30
30
40
40
50
65
80
Tinst
[Nm]
15
15
35
60
120
Screwing depth
212
1 / 2009
Critical edge
distance for
splitting
failure and
concrete
cone failure
hmin
[mm]
smin
[mm]
smin
[mm]
cmin
cmin
M10x
M10x
M8x40
30
40
M12x
50
M16x
65
M20x
80
100
100
100
100
100
100
100
130
160
60
60
60
60
80
80
125
130
160
60
60
80
125
130
160
[mm]
88
105
105
105
140
140
175
227
280
[mm]
88
105
140
175
227
280
[mm]
176
210
210
210
280
280
350
455
560
HKD-SR
HKD-ER
[mm]
176
210
280
350
455
560
HKD-S
HKD-E
[mm]
75
90
90
90
120
120
150
195
240
[mm]
75
90
120
150
195
240
[mm]
176
105
105
105
140
140
175
227
280
[mm]
176
105
140
175
227
280
[mm]
37
45
45
45
60
60
75
97
120
[mm]
37
45
60
75
97
120
HKD-S
HKD-E
HKD-SR
HKD-ER
HKD-S
HKD-E
scr,sp
scr,N
ccr,sp
HKD-SR
HKD-ER
HKD-S
HKD-E
HKD-SR
HKD-ER
ccr,N
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
1 / 2009
213
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
NRd,p = N0Rd,p fB
NRd,s
214
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
HKD-S
HKD-E
[kN]
5,1
5,1
9,2
12,4
9,2
13,4
21,1
37,2
59,1
HKD-SR
HKD-ER
[kN]
6,9
9,2
11,5
20,4
35,1
55,7
1 / 2009
N0Rd,p
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
HKD-S
HKD-E
[kN]
5,0
HKD-SR
HKD-ER
[kN]
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fre,N
Design splitting resistancea) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp fh,sp fre,N
Non-cracked concrete
Hilti
tech
data
Anchor size
[kN]
3,0
4,6
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
4,6
7,1
7,1
9,9
17,6
24,0
7,1
9,9
17,6
24,0
4,6
Rd,c
HKD-SR
[kN]
3,0
4,6
HKD-ER
a) Splitting resistance must only be considered for non-cracked concrete
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
1 / 2009
215
0,1
s/scr,sp
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
2,0
2,2
2,4
2,6
2,8
3,0
3,2
3,4
3,6
3,68
1,07
1,13
1,19
1,25
1,31
1,37
1,42
1,48
1,5
2/3
Influence of reinforcement
Anchor size
M8
M10
a)
M12
a)
M16
a)
M20
M24
a)
0,74
0,8
0,85
0,91
1
1
fre,N = 0,5 + hef/200mm 1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
VRd,c = V0Rd,c fB f f h f4
VRd,s
216
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
HKD-S
HKD-E
[kN]
3,0
3,0
5,5
5,9
5,5
6,4
11,3
17,5
27,8
HKD-SR
HKD-ER
[kN]
4,1
5,5
6,9
12,3
21,1
33,6
1 / 2009
Design concrete pryout resistance VRd,cp = V0Rd,cp fB f1,N f2,N f3,N fre,N
Non-cracked concrete
Hilti
tech
data
Anchor size
V0Rd,cp
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
HKD-S
HKD-E
[kN]
6,0
9,2
9,2
9,2
14,2
14,2
19,8
35,2
48,1
HKD-SR
HKD-ER
[kN]
6,0
9,2
14,2
19,8
35,2
48,1
[kN]
4,4
6,9
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
7,8
12,1
12,8
20,0
40,7
62,1
12,8
20,0
40,7
62,1
7,4
Rd,c
HKD-SR
[kN]
6,2
7,4
HKD-ER
a) For anchor groups only the anchors close to the edge must be considered.
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1 / 2009
217
Influence of reinforcement
M10x
M10x M12x M16x M20x
M8x40
30
40
50
65
80
= 0,5 + hef/200mm 1
0,63 a) 0,65 a) 0,65 a) 0,65 a) 0,7 a)
0,7 a) 0,75 a) 0,83 a) 0,9 a)
This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Anchor size
fre,N
a)
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,00
1,07
1,14
1,23
1,35
1,50
1,71
2,00
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0.75 1.50 2.25 3.00 3.75 4.50 5.25 6.00 6.75 7.50 8.25 9.00 9.75 10.50 11.25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
218
1 / 2009
Precalculated values
Design resistance calculated according ETAG 001, Annex C and data given in ETA-98/0001, issue 2008-02-12.
All data applies to concrete C 20/25 fck,cube =25 N/mm.
Design resistance
Single anchor, no edge effects
Non-cracked concrete
Hilti
Tech
data
Anchor size
100
100
100
M10x
30
100
3,0
4,6
4,6
4,6
5,0
7,1
9,9
17,6
24,0
4,6
7,1
9,9
17,6
24,0
[kN]
100
M10x
40
100
M12x
50
100
M16x
65
130
M20x
80
160
M8x40
HKD-S HKD-E
[kN]
3,0
3,0
4,7
5,0
5,5
6,1
11,3
17,5
27,8
HKD-SR HKD-ER
[kN]
4,1
4,7
6,1
12,3
21,1
33,6
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
100
100
100
100
100
100
100
130
160
[mm]
88
105
105
105
140
140
175
227
280
[kN]
3,0
4,6
4,6
4,6
5,0
7,1
9,9
17,6
24,0
4,6
7,1
9,9
17,6
24,0
1 / 2009
HKD-S HKD-E
[kN]
3,0
3,0
5,5
5,9
5,5
6,4
11,3
17,5
27,8
HKD-SR HKD-ER
[kN]
4,1
5,5
6,9
12,3
21,1
33,6
219
100
50
100
60
100
60
M10x
30
100
60
1,9
3,0
3,0
3,0
4,6
4,6
6,7
11,3
15,5
3,0
4,6
6,7
11,3
15,5
[kN]
100
80
M10x
40
100
80
M12x
50
100
125
M16x
65
130
130
M20x
80
160
160
M8x40
HKD-S HKD-E
[kN]
3,0
3,0
5,5
5,9
5,5
6,4
11,3
17,5
27,8
HKD-SR HKD-ER
[kN]
4,1
5,5
6,9
12,3
21,1
33,6
Recommended loads
Single anchor, no edge effects
Non-cracked concrete
Hilti
Tech
data
Anchor size
100
100
100
M10x
30
100
2,1
3,3
3,3
3,3
3,6
5,1
7,1
12,6
17,2
3,3
5,1
7,1
12,6
17,2
[kN]
220
100
M10x
40
100
M12x
50
100
M16x
65
130
M20x
80
160
M8x40
HKD-S HKD-E
[kN]
2,1
2,1
3,9
4,2
3,9
4,6
8,1
12,5
19,8
HKD-SR HKD-ER
[kN]
2,9
3,9
4,9
8,8
15,1
24,0
1 / 2009
M10x
30
M8x40
M10x
40
M12x
50
M16x
65
M20x
80
100
100
100
100
100
100
100
130
160
[mm]
88
105
105
105
140
140
175
227
280
[kN]
2,1
3,3
3,3
3,3
3,6
5,1
7,1
12,5
17,2
3,3
5,1
7,1
12,5
17,2
[kN]
2,1
2,1
3,4
3,6
3,9
4,3
8,1
12,5
19,8
HKD-SR HKD-ER
[kN]
2,9
3,4
4,3
8,8
15,1
24,0
100
50
100
60
100
60
M10x
30
100
60
1,4
2,1
2,1
2,1
3,3
3,3
4,8
8,1
11,0
2,1
3,3
4,8
8,1
11,0
[kN]
100
80
M10x
40
100
80
M12x
50
100
125
M16x
65
130
130
M20x
80
160
160
M8x40
HKD-S HKD-E
[kN]
2,1
2,1
3,9
4,2
3,9
4,6
8,1
12,5
19,8
HKD-SR HKD-ER
[kN]
2,9
3,9
4,9
8,8
15,1
24,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
221
HKD-E(R)
Carbon steel, stainless
steel without lip
Concrete
a)
Tensile
zone a)
Redundant
fastening
Fire
resistance
Corrosion
resistance
European
Technical
Approval
Benefits
- simple and well proven
- approved, tested and confirmed
by everyday jobsite experience
- reliable setting thanks to simple
visual check
- versatile
- for medium-duty fastening with
bolts or threaded rods
- available in various materials and
sizes for maximized coverage of
possible applications
CE
conformity
Approvals / certificates
Description
a)
European technical approval
Fire test report
Assessment report (fire)
a)
Authority / Laboratory
DIBt, Berlin
DIBt, Berlin
warringtonfire
All data given in this section for HKD-S(R) and HKD-E(R), according ETA-06/0047, issue 2007-11-30. The
anchor is to be used only for redundant fastening for non-structural applications.
Basic loading data for all load directions according design method B of ETAG 001
All data in this section applies to
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Concrete C 20/25 fck,cube = 25 N/mm to C50/60, fck,cube = 60 N/mm
- Minimum base material thickness
- Anchors in redundant fastening
222
1 / 2009
M6x30
M8x30
M10x30
M8x40
M10x40
M12x50
Load FRk
HKD-S, HKD-E
[kN]
3,0
3,0
4,0
5,0
6,0
6,0
HKD-SR, HKD-ER
[kN]
6,0
6,0
M6x30
M8x30
M10x30
M8x40
M10x40
M12x50
[kN]
1,7
1,7
2,2
2,8
3,3
3,3
HKD-SR, HKD-ER
[kN]
1,7
3,3
3,3
M6x30
M8x30
M10x30
M8x40
M10x40
M12x50
[kN]
1,2
1,2
1,6
2,0
2,4
2,4
HKD-SR, HKD-ER
[kN]
1,2
2,4
2,4
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
a)
Minimum number
of fixing points
Minimum number
of anchors per fixing point
2 kN
3 kN
The value for maximum design load of actions per fastening point NSd is valid in general that means all
fastening points are considered in the design of the redundant structural system. The value NSd may be
increased if the failure of one (= most unfavourable) fixing point is taken into account in the design
(serviceability and ultimate limit state) of the structural system e.g. suspended ceiling.
1 / 2009
223
Materials
Mechanical properties of HKD-S, HKS-E, HKD-SR and HKD-ER
Anchor size
Nominal
tensile
strength fuk
Yield strength
fyk
M6
M8
M10
M12
HKD-S
HKD-E
[N/mm]
560
560
510
510
HKD-SR
HKD-ER
[N/mm]
540
540
540
540
HKD-S
HKD-E
[N/mm]
440
440
410
410
HKD-SR
HKD-ER
[N/mm]
355
355
355
355
[mm]
20,9
26,1
28,8a)
31,6b)
58.7
[mm]
50
79
110a)
120b)
264
19
37
65
26
52
92
Stressed
cross-section
As
Moment of
resistance W
HKD-S
HKD-E
[Nm]
Char. bending With 5.6
resistance for Gr. Steel
rod or bolt
HKD-SR
M0Rk,s
HKD-ER
[Nm]
with A4-70
a) hnom = 30 mm
b)
hnom = 40 mm
Material quality
Part
Anchor Body
Tapered expansion
plug
224
Material
HKD-S
HKD-E
HKD-SR
HKD-ER
HKD-S
HKD-E
HKD-SR
HKD-ER
EN 10088-3
EN 10088-3
1 / 2009
Anchor dimensions
Anchor version
1 / 2009
Thread
size
hef
[mm]
d1
[mm]
d2
[mm]
d3
[mm]
d4
[mm]
d5
[mm
l1
[mm]
M6x30
30
3,9
15
M8x30
30
9,95
6,5
5.8
12
M10x30
30
11,8
8,2
7,55
12
M8x40
40
9,95
6,5
5,8
12
M10x40
40
11,95
8,2
7,1
16
M12x50
50
14,9
10,3
9,3
20
M8x30
30
9,95
6,5
5,3
12
M10x40
40
11,95
8,2
7,1
16
M12x50
50
14,9
10,3
9,3
20
225
Setting
Installation equipment
Anchor size
Rotary hammer
Machine setting tool
Hand Setting tool
Other tools
HSD-M
HSD-G
M6x25/30
M8x30
M10x30
M8x40
TE 2 TE 16
M10x40
M12x50
M6x25/30
M8x30
M10x30
M10x40
M12x50
M8x40
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
Setting details: depth of drill hole h1 and effective anchorage depth hef
M6x30
M8x30
M10x
30
M8x40
M10x
40
M12x
50
do
[mm]
10
12
10
12
15
dcut
[mm]
8,45
10,45
12,5
10,45
12,5
15,5
h1
[mm]
32
33
33
43
43
54
ls,min
[mm]
7,5
9,5
12
9,5
11,5
14
ls,max
[mm]
12,5
14,5
12
15
18
22
df
[mm]
12
12
14
hef
[Nm]
30
30
30
40
40
50
Tinst
[mm]
15
15
35
Screwing depth
226
1 / 2009
HKD-S
HKD-E
cmin
[mm]
M6x30
M8x30
M10x
30
M8x40
M10x
40
M12x
50
100
100
100
100
100
100
60
60
60
80
80
125
60
80
125
105
105
105
140
140
175
105
140
175
80
80
80
80
200
200
200
200
200
200
HKD-SR
cmin [mm]
HKD-ER
For minimum thickness of concrete member
Minimum base material
hmin [mm]
80
thickness
smin [mm]
HKD-S
200
Minimum
HKD-E
spacing
smin [mm]
HKD-SR
HKD-ER
Minimum
edge
distance
HKD-S
HKD-E
cmin
[mm]
150
150
150
150
150
HKD-SR
HKD-ER
cmin
[mm]
150
150
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
1 / 2009
227
Benefits
- fast setting
- flexibility of screw length
- an anchor for every base material
Concrete
Solid brick
Hollow brick
Autoclaved
aerated
concrete
Drywall
228
1 / 2009
Characteristic resistance
Anchor size
5x25
d)
Screw type
6x30
8x40
10x50
12x60 14x70
W
Size 4
DIN 96
C
Size 4
W
Size 5
DIN 96
C
Size 5
W
Size 6
DIN 96
C
Size 6
W
Size 8
DIN 96
C
Size 8
W
W
Size 10 Size 12
DIN
DIN
571
571
NRk
VRk
NRk
Solid clay brick
Mz 20
VRk
Solid sand-lime brick NRk
KS 12
VRk
NRk
Hollow clay brick
HlzB 12
VRk
Hollow clay brick
NRk
HlzB 12 15mm
VRk
plastered
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
1,5
2
0,85
1,2
1,25
1,25
0,4
1,15
0,5
0,3
0,75
0,25
-
2,75
4,5
1,75
1,5
2,5
2,8
0,5
1,75
1,75
0,75
1,5
0,4
-
4,25
6,25
3
2,2
4,25
3,7
1
-
2,5
1,75
2
0,6
-
7
11
4
5
6,6
1,25
-
10
15
5
7,5
1,4
-
15
28
5 a)
7,5 a)
1,6
-
[kN]
0,4
0,25
0,75
0,5
1,25
0,75
1,5
1,75
[kN]
1,15
1,75
Autoclaved aerated
concrete
AAC 2
Autoclaved aerated
concrete
AAC 4
Gypsum board
Thickness 12,5mm
NRk
[kN]
0,3
0,2
0,5
0,3
0,75
0,5
1,25
1,5
VRk
[kN]
0,2
0,25
0,4
NRk
[kN]
0,5
0,3
0,75
0,5
1,5
2,5
VRk
[kN]
0,65
0,9
1,5
Concrete C16/20
NRk
VRk
[kN]
[kN]
0,2
0,45
0,3
-
0,25
0,7
0,4
-
0,3
-
0,5
-
0,75
-
b)
Gypsum board
NRk [kN]
0,3
0,3
0,4
0,4
0,5
0,5 0,75 b) 1 b)
1,5 c)
Thickness
VRk [kN] 0,45
0,7
2x12,5mm
Fibre reinforced
NRk [kN] 0,45
0,6
0,9
gypsum board
VRk [kN] 0,72
0,96
1,44
Thickness 12,5mm
Fibre reinforced
NRk [kN] 0,45
1,2
1,8
2,1
gypsum board
Thickness
1,92
2,88
3,36
VRk [kN] 0,72
2x12,5mm
a)
only with screw diameter 6mm
b)
only with screw diameter 8mm
c)
only with screw diameter 10mm
d)
Screw type:
W: Wood-screw
C: Chipboard screw
Load data are valid for the mentioned woodscrew type, if other types or different screws are used the load
capacity may decrease.
1 / 2009
229
Design resistance
Anchor size
5x25
Screw typed)
8x40
10x50
C
Size 4
W
Size 5
DIN 96
C
Size 5
W
Size 6
DIN 96
C
Size 6
W
Size 8
DIN 96
0,77
1,26
0,49
0,42
0,70
0,78
0,14
0,49
0,49
0,70
1,96
3,08
1,12
2,80
4,20
1,40
4,20
7,84
1,40 c)
2,10 c)
0,17
1,40
1,85
0,35
2,10
0,11
1,19
1,75
0,84
0,62
1,19
1,04
0,28
0,39
0,45
0,21
0,14
0,35
0,21
0,42
0,49
0,56
0,08
0,21
0,14
0,28
0,35
0,42
0,28
0,56
0,70
0,84
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
0,42
0,56
0,24
0,34
0,35
0,35
0,11
0,32
0,14
[kN]
0,11
0,07
[kN]
0,32
Autoclaved aerated
concrete
AAC 2
Autoclaved aerated
concrete
AAC 4
Gypsum board
Thickness 12,5mm
NRk
[kN]
0,08
VRk
[kN]
0,06
NRk
[kN]
0,14
VRk
[kN]
0,18
NRk
VRk
[kN]
[kN]
0,06
0,13
0,08
0,21
0,07
0,21
0,42
0,49
0,56
C
Size 8
12x60 14x70
W
Size 4
DIN 96
NRk
VRk
NRk
Solid clay brick
Mz 20
VRk
Solid sand-lime brick NRk
KS 12
VRk
NRk
Hollow clay brick
HlzB 12
VRk
Hollow clay brick
NRk
HlzB 12 15mm
VRk
plastered
Concrete C16/20
6x30
W
W
Size 10 Size 12
DIN
DIN
571
571
0,49
0,06
0,14
0,07
0,08
0,21
0,11
0,14
0,25
0,08
0,07
0,20
0,42
0,42
0,11
0,08
0,14
0,21 a)
Gypsum board
NRk [kN] 0,08
0,08
0,11
0,11
0,14
0,14 0,21 a) 0,28 a) 0,42 b)
Thickness
VRk [kN] 0,13
0,20
2x12,5mm
Fibre reinforced
NRk [kN] 0,13
0,17
0,25
gypsum board
VRk [kN] 0,20
0,27
0,40
Thickness 12,5mm
Fibre reinforced
NRk [kN] 0,13
0,34
0,50
0,59
gypsum board
Thickness
0,54
0,81
0,94
VRk [kN] 0,20
2x12,5mm
a)
only with screw diameter 6mm
b)
only with screw diameter 8mm
c)
only with screw diameter 10mm
d)
Screw type:
W: Wood-screw
C: Chipboard screw
Load data are valid for the mentioned woodscrew type, if other types or different screws are used the load
capacity may decrease.
230
1 / 2009
Recommended loads e)
Anchor size
Screw type d)
NRk [kN]
Concrete C16/20
VRk [kN]
N
[kN]
Solid clay brick
Rk
Mz 20
VRk [kN]
Solid sand-lime brick NRk [kN]
KS 12
VRk [kN]
N
[kN]
Hollow clay brick
Rk
HlzB 12
VRk [kN]
Hollow clay brick
NRk [kN]
HlzB 12 15mm
VRk [kN]
plastered
Autoclaved aerated
concrete
AAC 2
Autoclaved aerated
concrete
AAC 4
Gypsum board
Thickness 12,5mm
5x25
W
C
0,3
0,1
0,4
0,17
0,06
0,24
0,25
0,15
0,25
0,08
0,05
0,23
6x30
W
C
0,55
0,35
0,9
0,35
0,15
0,3
0,5
0,3
0,56
0,1
0,08
0,35
8x40
W
C
0,85
0,5
1,25
0,6
0,35
0,44
0,85
0,4
0,74
0,2
0,12
1
1,32
0,25
1,5
1,5
0,28
0,32
0,08
0,15
0,1
0,25
0,15
0,3
0,35
0,4
0,06
0,15
0,1
0,2
0,25
0,3
0,2
0,4
0,5
0,6
0,05
0,23
NRk
[kN]
0,06
VRk
[kN]
0,04
NRk
[kN]
0,1
VRk
[kN]
0,13
NRk
VRk
[kN]
[kN]
0,04
0,09
10x50
W
C
1,4
2,2
0,8
12x60 14x70
W
W
2
3
3
5,6
1
1
0,35
0,04
0,1
0,05
0,06
0,15
0,08
0,1
0,18
0,06
0,05
0,14
0,3
0,3
0,08
0,06
0,1
0,15
Gypsum board
NRk [kN] 0,06
0,06
0,08
0,08
0,1
0,1
0,15
0,2
0,3
Thickness
VRk [kN] 0,09
0,14
2x12,5mm
Fibre reinforced
NRk [kN] 0,09
0,12
0,18
gypsum board
VRk [kN] 0,14
0,19
0,29
Thickness 12,5mm
Fibre reinforced
NRk [kN] 0,09
0,24
0,36
0,42
gypsum board
Thickness
VRk [kN] 0,14
0,38
0,58
0,67
2x12,5mm
a)
only with screw diameter 6mm
b)
only with screw diameter 8mm
c)
only with screw diameter 10mm
d)
Screw type:
W: Wood-screw
C: Chipboard screw
Load data are valid for the mentioned woodscrew type, if other types or different screws are used the load
capacity may decrease.
e)
With overall global safety factor = 5 to the characteristic loads and a partial safety factor of = 1,4 to the
design values.
1 / 2009
231
Base material
temperature
Temperature range
-40 C to +80 C
Materials
Material quality
Part
Plastic sleeve
Material
Polyamide 6
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
5x25
6x30
8x40
10x50
12x60
14x70
TE 2 TE 16
Screwdriver
Setting instruction
Use only for wall and floor applications. Not applicable for ceiling and faade applications.
For detailed information on installation see instruction for use given with the package of the product.
232
1 / 2009
Setting details: depth of drill hole h1 and effective anchorage depth hef
5x25
6x30
8x40
10x50
12x60
14x70
do
[mm]
10
12
14
dcut
[mm]
5,35
6,4
8,45
10,45
12,5
14,5
h1
[mm]
35
40
55
65
80
90
hnom
[mm]
25
30
40
50
60
70
Anchor length
[mm]
25
30
40
50
60
70
tfix
[mm]
[C]
-10 to +40
Installation temperature
Woodscrew diameter
a)
1 / 2009
a)
d
[mm]
4,5 - 5
5-6
7-8
8 - 10
10 - 12
3,5 - 4
The basic loading data are depending on the woodscrew diameters, if other types or different screws are
used the load capacity may decrease. Highlighted diameters refer to basic loading data table, except
footnotes a),b),c) of basic loading data tables.
233
HUD-L 10
Concrete
Solid brick
Hollow brick
Autoclaved
aerated
concrete
Benefits
- universal plastic anchor for weak
base materials and renovation
- for many base materials
- daily application
- excellent setting behaviour
Drywall
Characteristic resistance
Anchor size
Screw type
c)
HUD-L 6x50
Woodscrew 4,5x80
DIN 96
HUD-L 8x60
Woodscrew 5x90
DIN 96
HUD-L 10x70
Woodscrew 8mm
DIN 571
Concrete
FRk [kN]
1,15
1,4
9,0
C16/20
Solid clay brick
FRk [kN]
0,85
1,0
Mz 12
Solid clay brick
7,0
FRk [kN]
Mz 20
Solid sand-lime brick
FRk [kN]
0,85
1,0
2
KS 12
Hollow clay brick
FRk [kN]
0,5
0,75
1,5
Hlz 12 a)
Hollow sand-lime brick
FRk [kN]
0,7
0,8
KSL 12
Autoclaved aerated concrete
FRk [kN]
0,25
0,55
2,0
AAC 2 a)
Gypsum board
0,3
0,7
0,6 b)
FRk [kN]
Thickness 2x12,5mm a)
a)
Drilling without hammering
b)
Suitable for fitting hexagonal screws by hand
c)
Load data are valid for the mentioned woodscrew type, if other types or different screws are used the load
capacity may decrease.
234
1 / 2009
Design resistance
Anchor size
Screw type
Concrete C16/20
FRk
c)
[kN]
HUD-L 6x50
Woodscrew 4,5x80
DIN 96
HUD-L 8x60
Woodscrew 5x90
DIN 96
HUD-L 10x70
Woodscrew 8mm
DIN 571
0,32
0,39
2,52
Recommended loads d)
Anchor size
Screw type c)
Concrete C16/20
FRk
[kN]
HUD-L 6x50
Woodscrew 4,5x80
DIN 96
HUD-L 8x60
Woodscrew 5x90
DIN 96
HUD-L 10x70
Woodscrew 8mm
DIN 571
0,23
0,28
1,8
1 / 2009
235
Base material
temperature
Temperature range
-40 C to +80 C
Materials
Material quality
Part
Plastic sleeve
Material
Polyamide 6
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
HUD-L
6x50
HUD-L
8x60
HUD-L
10x70
TE 2 TE 16
Screwdriver
Setting instruction
Use only for wall and floor applications. Not applicable for ceiling and faade applications.
For detailed information on installation see instruction for use given with the package of the product.
236
1 / 2009
Setting details: depth of drill hole h1 and effective anchorage depth hef
HUD-L
6x50
HUD-L
8x60
HUD-L
10x70
do
[mm]
10
dcut
[mm]
6,4
8,45
10,45
h1
[mm]
70
80
90
hnom
[mm]
47
57
70
Anchor length
[mm]
47
57
70
tfix
[mm]
[C]
-10 to +40
Installation temperature
Recommended length of screw in
base material
ld
[mm]
55
65
75
4,5 - 5
5-6
7-8
Woodscrew diameter a)
d
[mm]
a)
The basic loading data are depending on the woodscrew diameters, if other types or different screws are
used the load capacity may decrease. Highlighted diameters refer to basic loading data table.
1 / 2009
237
Benefits
- plastic undercut anchor
- simple setting
- esp. for drywall applications
HLD
Drywall
Characteristic resistance
Anchor size
HLD 2
HLD 3
HLD 4
Anchoring principle a)
Gypsum board
Thickness 12,5mm
FRk
[kN]
0,4
0,4
0,4
FRk
[kN]
0,3
FRk
[kN]
0,6
A/B
FRk
[kN]
0,75
0,75
FRk
[kN]
1,25
238
2,5
1 / 2009
Desgin resistance
Anchor size
Anchoring principle
HLD 2
HLD 3
HLD 4
a)
Gypsum board
Thickness 12,5mm
FRd
[kN]
0,11
0,11
0,11
FRd
[kN]
0,08
FRd
[kN]
0,17
A/B
FRd
[kN]
0,21
0,21
FRd
[kN]
0,35
0,56
0,70
HLD 2
HLD 3
HLD 4
Recommended loads b)
Anchor size
Anchoring principle
a)
Gypsum board
Thickness 12,5mm
Frec
[kN]
0,08
0,08
0,08
Frec
[kN]
0,06
Frec
[kN]
0,12
A/B
Frec
[kN]
0,15
0,15
Concrete C16/20
C
Frec
[kN]
0,25
0,4
0,5
a) See setting details
b) With overall global safety factor = 5 to the characteristic loads and a partial safety factor of = 1,4 to the
design values.
Base material
temperature
Temperature range
-40 C to +80 C
Materials
Material quality
Part
Sleeve
1 / 2009
Material
Polyamide PA 6
239
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
TE 2 TE 16
Screwdriver
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
HLD 2
HLD 3
HLD 4
do
[mm]
h1
[mm]
50
56
66
lS
[mm]
33 + tfix
40 + tfix
49 + tfix
(anchoring principle C)
lS
[mm]
40 + tfix
46 + tfix
56 + tfix
dS
[mm]
4-5
(anchoring principle C)
dS
[mm]
5-6
(anchoring principle A)
[mm]
4 - 12
15 - 19
24 28
(anchoring principle B)
[mm]
12 - 16
19 - 25
28 32
(anchoring principle C)
[mm]
35
42
50
Screw length
Screw diameter
240
[C]
10
-10 to +40
1 / 2009
1 / 2009
241
HRD-U 10 / -S 10 / -U 14
Frame anchor
Benefits
- universal frame anchor for
faade, steelwork, and
mechanical installation
- base material versatility
- excellent setting behaviour
HRD-U 14
Carbon steel
Stainless steel
Concrete
Solid brick
Hollow brick
Autoclaved
aerated
concrete
Fire
resistance
Approvals / certificates
Description
Allgemeine bauaufsichtliche
Zulassung
(national German approval) a)
Authority / Laboratory
DIBt, Berlin
Z-21.2-599 / 2007-10-25
IBMB, Braunschweig
242
1 / 2009
HRD-U 10 / -S 10 / -U 14
Frame anchor
Recommended loads
Anchor size
HRD-U 10
HRD-S 10
HRD-U 14
Concrete
C12/15
Frec
[kN]
1,6
1,2
1,8
Mz 12
Frec
[kN]
0,6
0,6
0,6
Mz 20
Frec
[kN]
1,2
0,8
1,25
KS 12/2,0
Frec
[kN]
0,6
0,6
0,6
V2
Frec
[kN]
0,25
0,25
0,5
Hlz 12 1,0
Frec
[kN]
0,3
0,5
KSL 6
Frec
[kN]
0,4
0,4
0,6
Hbl 2
Frec
[kN]
0,25
0,25
0,3
AAC 2
Frec
[kN]
0,2
0,2
0,3
AAC 4
Frec
[kN]
0,5
0,35
0,6
P 3,3
Frec
[kN]
0,2
0,2
0,3
P 4,4
Frec
[kN]
0,5
0,35
0,6
Plant Laussig
Frec
[kN]
0,3
Plant Parchim
Frec
[kN]
0,15
Frec
[kN]
0,6
0,6
Frec
[kN]
0,5
0,7
AAC blocks
AAC members
AAC acc. TGL
Thin skins of external wall
paneels
hwpLb acc. TGL
Base material
temperature
Temperature range
-40 C to +80 C
1 / 2009
243
HRD-U 10 / -S 10 / -U 14
Frame anchor
Materials
Mechanical properties of HRD-U 10 / S 10 / U 14
Anchor size
U 10
S 10
U 14
[N/mm]
600
Nominal tensile strength fuk
[N/mm]
580
500
[N/mm]
480
Yield strength fyk
[N/mm]
450
400
Stressed cross-section As
[mm]
31,2
56,8
Moment of resistance W
[mm]
24,6
60,4
Carbon steel [Nm]
17,7
43,5
Char. bending resistance M0Rk,s
Stainless steel [Nm]
17,1
36,2
The recommended bending moment shall be calculated by dividing the characteristic bending moment by 1,4 and
1,25
Carbon steel
Stainless steel
Carbon steel
Stainless steel
Material quality
Part
Sleeve
Screw
HRD
HRD-UG
HRD-UR
Material
Polyamide
Carbon steel, galvanised to min. 5 m
Stainless steel
Anchor dimensions
Anchor size
U 10
S 10
U 14
UP 14
tfix,min
[mm]
10
10
10
10
tfix,max
[mm]
160
130
280
250
dnom
[mm]
10
10
14
14
l1,min
[mm]
80
60
80
110
l1,max
[mm]
230
180
350
330
dS
[mm]
10
10
l2,min
[mm]
85
65
85
115
l2,max
[mm]
235
285
355
335
244
1 / 2009
HRD-U 10 / -S 10 / -U 14
Frame anchor
dnom
HRD-U 10
l1
dnom
HRD-S 10
l1
HRD-U 14
dnom
l1
ds
l2
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
U 10
S 10
U 14
TE16
TE2 TE16
TE40
hammer, screw driver
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
1 / 2009
245
HRD-U 10 / -S 10 / -U 14
Frame anchor
Setting details: depth of drill hole h1 and effective anchorage depth hnom
S 10
U 14
do
[mm]
10
10
14
dcut
[mm]
10,45
10,45
14,5
h1
[mm]
80
60
85
df
[mm]
10,5
10,5
14,5
hnom
[mm]
70
50
70
Installation temperature
246
[C]
-10 - +40
1 / 2009
HRD-U 10 / -S 10 / -U 14
Frame anchor
hmin
hmin
hmin
hmin
hmin
smin
smin
smin
smin
smin
smin
smin1
smin2
cmin
cmin
cmin
cmin
cmin
cmin
U 10
120
115
115
40
40
150
100
250
100a)
100
100
50
300
100
100
100
150
50
100
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
S 10
100
115
115
40
40
100
100
250
100
50
240
80
100
100
50
100
U 14
120
115
115
150
250
250
100
50
300
100
100
100
100
s2
s1
1 / 2009
247
Concrete
a)
Tensile
zone a)
Solid brick
Hollow brick
Anchor version
Benefits
HRD-U 8 Carbon
steel, Stainless steel
Autoclaved
aerated
concrete
Window
frame
Fire
resistance
European
Technical
Approval
CE
conformity
Approvals / certificates
Description
European technical approval a)
Fire test report
Window frame report
Authority / Laboratory
DIBt, Berlin
MFPA, Leipzig
Ift, Rosenheim
a) All data given in this section according ETA-07/0219, issue 2007-09-17. The anchor is to be used only for
redundant fastening for non-structural applications.
248
1 / 2009
U 8 / UR 8
NRk,0
[kN]
6,0
VRk,0
[kN]
6,9 / 6,6
NRk,0
[kN]
8,5
VRk,0
[kN]
6,9 / 6,6
NRk,0
[kN]
3,85
VRk,0
[kN]
6,9 / 6,6
NRk,0
[kN]
5,5
VRk,0
[kN]
6,9 / 6,6
fb 20 N/mm
FRk,0
[kN]
2,6
fb 10 N/mm
FRk,0
[kN]
1,75
fb 20 N/mm
FRk,0
[kN]
2,9
fb 10 N/mm
FRk,0
[kN]
2,0
fb 6 N/mm2
FRk,0
[kN]
0,70
FRk,0
[kN]
2,0
fb 12 N/mm2
FRk,0
[kN]
0,60
fb 12 N/mm2
FRk,0
[kN]
1,1
fb 2 N/mm2
FRk,0
[kN]
0,70
fb 22 N/mm
FRk,0
[kN]
1,6
fb 25 N/mm
FRk,0
[kN]
1,2
fb 40 N/mm
FRk,0
[kN]
0,95
fb 6 N/mm
FRk,0
[kN]
0,65
fb 4 N/mm
FRk,0
[kN]
0,75
fb 6 N/mm
FRk,0
[kN]
0,75
1 / 2009
249
U 8 / UR 8
NRk
[kN]
VRk
[kN]
NRk
[kN]
VRk
[kN]
NRk
[kN]
1,75
VRk
[kN]
6,9 / 6,6
NRk
[kN]
2,5
VRk
[kN]
6,9 / 6,6
fb 20 N/mm
FRk
[kN]
1,5
fb 10 N/mm
FRk
[kN]
1,2
fb 20 N/mm
FRk
[kN]
2,5
fb 10 N/mm
FRk
[kN]
2,0
fb 6 N/mm2
FRk
[kN]
0,50
FRk
[kN]
fb 12 N/mm2
FRk
[kN]
0,50
fb 12 N/mm2
FRk
[kN]
0,75
fb 2 N/mm2
FRk
[kN]
0,30
fb 22 N/mm
FRk
[kN]
1,5
fb 25 N/mm
FRk
[kN]
0,9
fb 40 N/mm
FRk
[kN]
0,60
fb 6 N/mm
FRk
[kN]
0,50
fb 4 N/mm
FRk
[kN]
fb 6 N/mm
FRk
[kN]
250
1 / 2009
Design resistance
Anchor size
U 8 / UR 8
1 / 2009
1,68
VRd
[kN]
5,52
NRd
[kN]
1,98
VRd
[kN]
5,52
NRd
[kN]
0,98
VRd
[kN]
5,52
NRd
[kN]
1,4
[kN]
5,52
fb 20 N/mm
FRd
[kN]
0,6
fb 10 N/mm
FRd
[kN]
0,48
fb 20 N/mm
FRd
[kN]
1,0
fb 10 N/mm
FRd
[kN]
0,8
fb 6 N/mm2
FRd
[kN]
0,20
FRd
[kN]
0,56
fb 12 N/mm2
FRd
[kN]
0,20
fb 12 N/mm2
FRd
[kN]
0,30
fb 2 N/mm2
FRd
[kN]
0,12
fb 22 N/mm
FRd
[kN]
0,6
fb 25 N/mm
FRd
[kN]
0,36
fb 40 N/mm
FRd
[kN]
0,24
fb 6 N/mm
FRd
[kN]
0,20
fb 4 N/mm
FRd
[kN]
0,21
fb 6 N/mm
FRd
[kN]
0,21
[kN]
VRd
NRd
251
Recommended loads a)
Anchor size
U 8 / UR 8
1,2
Vrec
[kN]
3,9
Nrec
[kN]
1,7
Vrec
[kN]
3,9
Nrec
[kN]
0,7
Vrec
[kN]
3,9
Nrec
[kN]
1,0
[kN]
3,9
fb 20 N/mm
Frec
[kN]
0,42
fb 10 N/mm
Frec
[kN]
0,34
fb 20 N/mm
Frec
[kN]
0,70
fb 10 N/mm
Frec
[kN]
0,57
fb 6 N/mm2
Frec
[kN]
0,14
Frec
[kN]
0,40
fb 12 N/mm2
Frec
[kN]
0,14
fb 12 N/mm2
Frec
[kN]
0,21
fb 2 N/mm2
Frec
[kN]
0,09
fb 22 N/mm
Frec
[kN]
0,43
fb 25 N/mm
Frec
[kN]
0,25
fb 40 N/mm
Frec
[kN]
0,17
fb 6 N/mm
Frec
[kN]
0,14
fb 4 N/mm
Frec
[kN]
0,15
fb 6 N/mm
Frec
[kN]
0,15
[kN]
Vrec
Nrec
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
252
1 / 2009
a)
Minimum number
of fixing points
Minimum number
of anchors per fixing point
3 kN
4,5 kN
The value for maximum design load of actions per fastening point NSd is valid in general that means all
fastening points are considered in the design of the redundant structural system.
Base material
temperature
Temperature range
-40 C to +80 C
Materials
Mechanical properties of HRD-U 8
Anchor size
HRD-UG
HRD-UR
HRD-UG
HRD-UR
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[mm]
[mm]
HRD-UG [Nm]
HRD-UR [Nm]
U 8 / UR 8
600
580
480
450
22,9
15,5
11,1
10,8
Material quality
Part
Sleeve
Screw
1 / 2009
HRD-U
HRD-UG
HRD-UR
Material
Polyamide
Carbon steel, galvanised to min. 5 m
Stainless steel
253
Anchor dimensions
Anchor size
U 8 / UR 8
tfix,min
[mm]
10
tfix,max
[mm]
90
dnom
[mm]
l1,min
[mm]
60
l1,max
[mm]
140
dS
[mm]
l2,min
[mm]
65
l2,max
[mm]
145
dnom
l1
l2
ds
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
254
TE2 TE16
hammer, screw driver
1 / 2009
Setting instruction
For detailed information on installation see instruction for use given with the package of the product.
Setting details: depth of drill hole h1 and nominal anchorage depth hnom
hnom
h1
ttol
tfix
hmin
1 / 2009
255
do
[mm]
dcut
[mm]
8,45
h1
[mm]
60
df
[mm]
8,5
hnom
[mm]
50
[C]
-10 - +40
Installation temperature
Setting parameters
Anchor size
Minimum base
material thickness
Minimum spacing of
single anchors
Minimum spacing in a
group in masonry
Concrete
Masonry
Concrete C16/20
Concrete C12/15
Masonry
Ital. Hollow brick Doppio Uni
Ital. Hollow brick Mattone
Other masonry
Concrete C16/20
Concrete C12/15
Minimum edge
Ital. Hollow brick Doppio Uni
distance
Ital. Hollow brick Mattone
Other masonry
Critical spacing in concretea)
Critical edge distance Concrete C16/20
in concreteb)
Concrete C12/15
hmin
hmin
smin
smin
smin
smin1
smin2
smin1
smin2
cmin
cmin
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
100
115
100
140
250
120
240
200
400
50
70
cmin
[mm]
60
cmin
scr,N
ccr,N
ccr,N
[mm]
[mm]
[mm]
[mm]
100
60
100
140
s2
s
s1
a)
b)
256
For spacing larger than the critical spacing each anchor in a group can be considered in design.
For edge distance smaller than critical edge distance the design loads have to be reduced.
1 / 2009
Design method
Design method according ETAG 020, Annex C. Design resistance according data given in ETA07/0219, issue 2007-09-17.
Valid for a group of two anchors
Influence of concrete strength
Influence of edge distance
Influence of spacing
The design method is based on the following simplifications:
Minimum base material thickness hmin
All data for concrete C20/25
No different loads are acting on individual anchors (no eccentricity)
The values are valid for a single anchor or a anchor group with spacing < scr,N (for anchor
groups with spacing scr,N each anchor can be considered).
For more complex fastening applications please use the anchor design software PROFIS Anchor.
NRd,s
NRd,p
HRD-U
HRD-UR
[kN]
[kN]
U8
7,3
6,8
[kN]
[kN]
U8
1,4
1,4
1 / 2009
HRD-U
HRD-UR
257
VRd,s
VRd,c = f1 c
1,5
/ 1000
VRd,s
U8
5,5
5,2
[kN]
[kN]
Design concrete pryout resistance VRd,c = f1 c1,5 / 1000 (c in [mm], result in [kN])
Influencing factors
Influence of edge distance
Anchor type
f1 =
U8
5,1
258
1 / 2009
1 / 2009
259
Concrete
Solid brick
Perforated
brick
Benefits
- impact anchor for light frames,
battens and profiles on solid base
materials
- impact and temperature resistant
- high quality plastic
Autoclaved
aerated
concrete
Approvals / certificates
Description
Authority / Laboratory
Fiche technique SOCOTEC a)
SOCOTEC, Paris
a) All data given in this section according SOCOTEC CX 5217 / 2000-08
260
1 / 2009
Recommended loads a)
Anchor size HPS-1
Concrete C16/20
NRd
4/0
5/0
5/5
5/15
6/0
6/25
6/30
6/40
8/0
8/10
8/40
8/60
8/100
[kN]
0,05
0,10
0,15
0,25
0,25
0,30
0,40
0,40
VRd
[kN]
0,15
0,30
0,35
0,55
0,35
0,50
0,90
0,50
Engineering brick,
12 hole, class B
NRd
[kN]
0,05
0,10
0,15
0,25
0,25
0,30
0,40
0,40
VRd
[kN]
0,15
0,30
0,35
0,55
0,35
0,50
0,90
0,50
Perforated brick, 3
hole cammon
NRd
[kN]
0,05
0,10
0,15
0,20
0,20
0,25
0,30
0,30
VRd
[kN]
0,15
0,30
0,35
0,55
0,35
0,50
0,90
0,55
[kN]
0,08
0,15
0,15
0,20
0,25
0,25
[kN]
0,15
0,25
0,15
0,40
0,40
0,25
[kN]
0,05
0,08
0,08
0,12
0,12
[kN]
0,10
0,15
0,10
0,25
0,15
Autoclaved aerated
concrete AAC 4,
AAC 6
NRd
[kN]
0,08
0,10
0,10
0,15
0,15
VRd
[kN]
0,10
0,12
0,10
0,30
0,20
[kN]
0,05
0,10
0,15
0,20
0,20
0,25
0,35
0,35
[kN]
0,15
0,25
0,30
0,40
0,25
0,50
0,90
0,55
a) With overall global safety factor = 5 to the characteristic loads and a partial safety factor of = 1,4 to the
design values.
Base material
temperature
Temperature range
-40 C to +80 C
Materials
Material quality
Part
Plastic sleeve
Screw
1 / 2009
Material
Polyamide 6.6
Carbon steel, galvanised to 5 m
or
Stainless steel, grade A2
or
Stainless steel, grade A2, copper-plated
261
Setting
Installation equipment
Anchor size
HPS-1 4
HPS-1 5
Rotary hammer
Other tools
HPS-1 6
HPS-1 8
TE2 TE16
Screwdriver
Setting instruction
Setting details: depth of drill hole h1 and effective anchorage depth hef
HPS-1 4
HPS-1 5
HPS-1 6
HPS-1 8
do
[mm]
dcut
[mm]
4,35
5,35
6,4
8,45
h1
[mm]
25
30
40
50
hnom
[mm]
20
20
25
30
Anchor length
[mm]
21,5
22 - 37
27 - 67
28,5
132,5
tfix
[mm]
15
40
100
Installation temperature
262
[C]
-10 to +40
1 / 2009
1 / 2009
s
c
[mm]
[mm]
HPS-1 4/
HPS-1 5/
HPS-1 6/
HPS-1 8/
20
20
25
25
30
30
35
35
263
Benefits
- metal undercut anchor with metric
screw, esp. for drywall
- metal to metal fastening
- reliable undercut
HHD-S
drywall
Recommended loads a)
Anchor size
Nrec [kN]
Hollow brick
web thickness 20mm
Vrec [kN]
Nrec [kN]
Gypsum board
Thickness 10mm
Vrec [kN]
Nrec [kN]
Gypsum board
Thickness 12,5mm
Vrec [kN]
Nrec [kN]
Gypsum board
Thickness 2x12,5mm
Vrec [kN]
Nrec [kN]
Fibre reinforced gypsum board
Thickness 10mm
Vrec [kN]
Nrec [kN]
Fibre reinforced gypsum board
Thickness 12,5mm
Vrec [kN]
Nrec [kN]
Fibre reinforced gypsum board
Thickness 2x12,5mm
Vrec [kN]
a) With overall global safety factor = 3 to the characteristic
design values.
M4
0,1
0,3
0,2
0,5
0,2
0,5
0,2
0,5
0,3
0,6
loads and a
M5
M6
M8
0,2
0,2
0,2
0,5
0,5
0,5
0,2
0,2
0,2
0,5
0,5
0,5
0,4
0,3
0,4
1
0,9
1
0,3
0,25
0,4
0,6
0,8
0,9
0,5
0,3
0,6
1
1
1,2
0,9
0,8
0,9
1,1
1,8
1,7
partial safety factor of = 1,4 to the
Materials
Material quality
Part
Sleeve
Screw
264
Material
Carbon steel, galvanised
Carbon steel, galvanised
1 / 2009
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
TE2 TE16
Screwdriver, HHD-SZ2 expansion tool
Setting instruction
Setting details:
1 / 2009
M4/4
M4/6
M4/12
M4/19
M5/8
M5/12
M5/25
do
[mm]
l
h
lS
d
hmin,max
[mm]
[mm]
[mm]
[mm]
20
4
25
M4
3-4
32
6
39
M4
6-7
38
12,5
45
M4
10 - 13
45
19
52
M4
18 - 20
38
8
45
M5
6-8
52
12,5
58
M5
11 - 13
65
25
71
M5
23 - 25
tfix
[mm]
15
25
25
25
25
30
30
M6/9
M6/12
M6/24
M6/40
M8/12
M8/24
M8/40
80
88
M6
38 - 40
54
12,5
60
M8
11 - 13
66
25
72
M8
23 - 25
83
40
90
M8
38 40
30
30
30
35
do
[mm]
l
h
lS
d
hmin,max
[mm]
[mm]
[mm]
[mm]
38
9
45
M6
7-9
52
12,5
58
M6
11 - 13
65
25
71
M6
23 - 25
tfix
[mm]
20
30
30
40
265
Benefits
HSP
HFP
drywall
Recommended loads
Anchor size
Gypsum board
Thickness 12,5 mm
Gypsum board
Thickness 2x12,5 mm
Gypsum panel
Thickness 100 mm a)
HSP
HFP
Nrec
[kN]
0,07
0,07
Vrec
[kN]
0,18
0,18
Nrec
[kN]
0,1
Vrec
[kN]
0,27
Nrec
[kN]
0,09
Vrec
[kN]
0,25
Materials
Material quality
Part
HFP
HSP
Screw
266
Material
Polyamide, fibre reinforced
Zinc die-casting
Carbon steel, galvanised to min. 5m
1 / 2009
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
Setting instruction
Setting details:
HSP
HFP
[mm]
15
10
39
tfix
Anchor length
[mm]
Screw length
[mm]
Screw diameter
[mm]
1 / 2009
29
15 + tfix
4,5
4,5
267
Benefits
- 8mm anchor for concrete ceilings
- hand-setting
- follow-up expansion
HA 8 H1
Concrete
Tensile
zone
Fire
resistance
Approvals / certificates
Description
Allgemeine bauaufsichtliche
Zulassung (national approval in
Germany) a)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
Z-21.1-88 / 2007-04-18
IBMB, Braunschweig
warringtonfire
UB 3245/1817-5 / 1997-12-12
WF 166402 / 2007-10-26
Recommended loads
Non-cracked concrete
Cracked concrete
(redundant fastening)
0,8
0,8
Anchor size
Tensile Nrec
268
[kN]
1 / 2009
Materials
Material quality
Part
Expansion sleeve
Bolt
Material
Carbon steel, galvanised to min. 5 m
Carbon steel, galvanised to min. 5 m
Mechanical properties of HA 8
Anchor size
Nominal tensile strength fuk [N/mm]
Yield strength fyk [N/mm]
HA 8 expansion sleeve
370
270
HA 8 bolt
460
220
Anchor dimensions
Anchor size
Bolt diameter
dR
[mm]
l1
[mm]
66
dR
l1
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
TE2 TE16
hammer, blow out pump
Setting instruction
1 / 2009
269
Setting details: depth of drill hole h1 and effective anchorage depth hef
Setting details HA 8
Nominal diameter of drill bit
do
[mm]
dcut
[mm]
8,45
h1
[mm]
50
hef
[mm]
40
270
hmin
s
c
ce
[mm]
[mm]
[mm]
[mm]
100
200
100
150
1 / 2009
1 / 2009
271
well proven
simple installation
small drill bit diameter
reliable setting thanks to simple
visual check
- for fixing in cracked concrete,
redundant fastening only, e.g.
suspended ceilings
DBZ
Carbon steel
Concrete
a)
Tensile
zone a)
Multiple
use
Fire
resistance
European
Technical
Approval
CE
conformity
Approvals / certificates
Description
European technical approval a)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt
DIBt
warringtonfire
a) All data given in this section for DBZ wedge anchor according ETA-06/0179, issue 2006-09-13. The anchor is
to be used only for redundant fastening for non-structural applications.
Basic loading data for all load directions according design method C of ETAG 001
All data in this section applies to
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Concrete C 20/25 fck,cube = 25 N/mm to C50/60, fck,cube = 60 N/mm
- Anchors in redundant fastening
272
[kN]
DBZ 6/4,5
DBZ 6/35
6,0
6,0
1 / 2009
DBZ 6/4,5
DBZ 6/35
4,0
4,0
DBZ 6/4,5
DBZ 6/35
2,2
2,2
DBZ 6/4,5
DBZ 6/35
1,6
1,6
[kN]
[kN]
[kN]
With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
a)
Minimum number
of fixing points
Minimum number
of anchors per fixing point
2 kN
3 kN
The value for maximum design load of actions per fastening point NSd is valid in general that means all
fastening points are considered in the design of the redundant structural system. The value NSd may be
increased if the failure of one (= most unfavourable) fixing point is taken into account in the design
(serviceability and ultimate limit state) of the structural system e.g. suspended ceiling.
Materials
Mechanical properties of DBZ
Anchor size
DBZ 6/4,5
DBZ 6/35
Nominal tensile
strength
fuk
[N/mm]
390
390
Yield strength
fyk
[N/mm]
310
310
Stressed crosssection
As
[mm]
26
26
Char. bending
resistance
M0Rk,s [Nm]
5,0
5,0
1 / 2009
273
Material
1 Anchor shank
2 Expansion pin
Marking
d1
l1
l2
Anchor dimensions
Anchor size
DBZ 6/4,5
DBZ 6/35
l1
[mm]
2,5
2,5
Max. distance
d1
[mm]
6,4
6,4
[mm]
37,5
68
DBZ 6/4,5
DBZ 6/35
Setting
Recommended installation equipment
Anchor size
Rotary hammer
Other tools
TE 2 TE 7
hammer, blow out pump
Setting instruction
274
1 / 2009
Member thickness
Thickness
of fixture
df
tfix
hef
Anchorage
h1
Setting details
Fixture
e.g. wire
Anchor size
Thickness of fixture
Depth of drill hole
Nominal diameter
of drill bit
Cutting diameter of
drill bit
Clearance hole
diameter
DBZ 6/4,5
tfix [mm]
DBZ 6/35
4,5
20 tfix 35
5 tfix < 20
h1 [mm]
40
55
70
d0 [mm]
dcut [mm]
6,4
6,4
df [mm]
DBZ 6/4,5
4,5
20 tfix 35
5 tfix < 20
hmin [mm]
80
80
100
hef [mm]
32
32
Critical spacing
scr [mm]
200
200
ccr [mm]
150
150
Minimum member
thickness
Effective anchorage
depth
a)
tfix [mm]
DBZ 6/35
The critical spacing (critical edge distance) shall be kept. Smaller spacing (edge distance) than critical spacing
(critical edge distance) are not covered by the design method.
1 / 2009
275
Concrete
Solid brick
Hollow brick
Autoclaved
aerated
concrete
Anchor version
Benefits
HT
Fire
resistance
Approvals / certificates
Description
Fire test report
Assessment report (fire)
Authority / Laboratory
IBMB, Braunschweig
warringtonfire
UB 3016/1114-CM / 2006-03-13
WF 166402 / 2007-10-26
Characteristic resistance
HT 8
HT10
NRk
[kN]
4,2
5,0
VRk
[kN]
6,6
7,0
NRk
[kN]
0,3
VRk
[kN]
0,5
NRk
[kN]
1,8
2,6
VRk
[kN]
5,0
NRk
[kN]
1,8
2,6
VRk
[kN]
5,0
NRk
[kN]
1,5
VRk
[kN]
0,5
276
1 / 2009
Recommended loads
HT 8
HT10
Nrec
[kN]
1,4
1,7
Vrec
[kN]
0,5
0,5
Nrec
[kN]
0,1
Vrec
[kN]
0,15
Nrec
[kN]
0,6
0,8
Vrec
[kN]
0,5
Nrec
[kN]
0,6
0,8
Vrec
[kN]
0,5
Nrec
[kN]
0,5
Vrec
[kN]
0,15
Materials
Material quality
Part
Bolt
Sleeve
Material
steel grade 4.8, zinc plated to 5 m
steel 02 DIN 17162, sendzimir zinc plated to 20 m
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
TE1 TE16
hammer, screwdriver
Setting instruction
Install anchor.
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
277
min. 50mm
Setting details HT
HT 8
8x72
8x92
8x112
do
[mm]
h1
[mm]
50
50
50
Anchorage depth
hnom
[mm]
30
30
30
Anchor length
[mm]
72
92
112
Torque moment
Tinst
[Nm]
hmin
[mm]
100
100
100
Drill bit
TE-CX-8/22
TE-CX-8/17
HT 8
8x132
8x152
8x182
do
[mm]
h1
[mm]
50
50
50
Anchorage depth
hnom
[mm]
30
30
30
Anchor length
[mm]
132
152
182
Torque moment
Tinst
[Nm]
hmin
[mm]
100
100
100
TE-CX-8/22
Drill bit
TE-CX-8/27
HT 10
10x72
10x92
10x112
do
[mm]
10
10
10
h1
[mm]
50
50
50
Anchorage depth
hnom
[mm]
30
30
30
Anchor length
[mm]
72
92
112
Torque moment
Tinsta)
[Nm]
8/4
8/4
8/4
hmin
[mm]
100
100
100
Drill bit
a) First value: solid base material, second value: hollow base material
278
TE-C-10/17
TE-C-10/22
1 / 2009
HT 10
10x132
10x152
10x182
10x202
do
[mm]
10
10
10
10
h1
[mm]
50
50
50
50
Anchorage depth
h0
[mm]
30
30
30
30
Anchor length
[mm]
132
152
182
202
[Nm]
8/4
8/4
8/4
8/4
[mm]
100
100
100
100
Torque moment
Tinst
hmin
a)
Drill bit
TE-C10/22
TE-C-10/27
TE-C10/37
a) First value: solid base material, second value: hollow base material
1 / 2009
279
HK | Ceiling anchor
HK Ceiling anchor
Anchor version
Benefits
- well proven
- small drill bit diameter
- for fixing in cracked concrete,
redundant fastening only, e.g.
suspended ceilings
HK
Carbon steel
HK I
Carbon steel
Concrete
a)
Tensile
zone a)
Multiple
use
Fire
resistance
European
Technical
Approval
CE
conformity
Approvals / certificates
Description
European technical approval a)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt
DIBt
warringtonfire
a) All data given in this section for HK Ceiling anchor according ETA-04/0043, 2006-10-06. The anchor is to be
used only for multiple use for non-structural applications.
HK+
HK L
a)
Resistance FRk
[kN]
2,5
5,0
a) for all load directions (tension, shear and combined tension and shear loads)
HK 8
5,0
HK+
a)
HK L
Resistance FRd
[kN]
1,4
2,0
a) for all load directions (tension, shear and combined tension and shear loads)
280
HK 8
2,0
1 / 2009
HK | Ceiling anchor
b)
[kN]
HK+
HK L
HK 8
1,0
1,4
1,4
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
b) for all load directions (tension, shear and combined tension and shear loads)
Special case: Groups of n=2 and/or n=4 anchors with small spacing
The basic loading data for a single
anchor is valid for one fixing point.
F
F
Single
anchors
scr
100
F
F
ccr
F
group of
2 anchors
ccr
scr
60
scr
group of
4 anchors
single anchors,
or
groups of 2 anchors
with s1 60 mm
or
groups of 4 anchors
with s1 100 mm and s2 100 mm
100
a)
Minimum number
of fixing points
Minimum number
of anchors per fixing point
2 kN
3 kN
The value for maximum design load of actions per fastening point NSd is valid in general that means all
fastening points are considered in the design of the redundant structural system. The value NSd may be
increased if the failure of one (= most unfavourable) fixing point is taken into account in the design
(serviceability and ultimate limit state) of the structural system e.g. suspended ceiling.
Materials
Mechanical properties of HK
Anchor size
Char. bending
resistance
1 / 2009
M0Rk,s [Nm]
HK+
HK L
HK 8
7,7
7,7
18
281
HK | Ceiling anchor
Material quality of HK
Part
Material
Anchor HK + / HK L / HK 8
Anchor dimension
K6L
K6L
K6L
h1
lp
lth
l1
da
Anchor size
Thread size
Length of thread
Length of projection
Diameter of sleeve
Length of sleeve
Embedment depth
lth
lp
da
l1
h1
[mm]
[mm]
[mm]
[mm]
[mm]
Anchor size
Thread size
Diameter of sleeve
Length of sleeve
Embedment depth
282
da [mm]
l1 [mm]
h1 [mm]
HK+
HK L
M6/tfix M8/tfix M6/tfix M8/tfix
I M6
external external external external Internal
M6
M8
M6
M8
M6
5 50
5 50
12
5 ... 300
5 ... 300
8
15
37
42
I M8
internal
M8
12
10
15
HK8
I M8
I M10
I M12 I M8/M10
internal internal internal internal
M8
M10
M12 M8/M10
10
12
14
12
15
20
20
25
43
1 / 2009
HK | Ceiling anchor
Setting
Recommended installation equipment
Anchor size
HK +
HK L
Rotary hammer
HK 8
TE 2 TE 16
SDS+
Setting tool
SDS 2
HSM / HSM I
Other tools
SDS 8
HSM 8 / HSM 8 I
Setting instruction
1 / 2009
Set anchor.
283
HK | Ceiling anchor
Setting details
h1
K6L
K6L
lp
l1
SDS 2
lth
K6L
h1
da
Setting tool
HSM..
Anchor size
Depth of drill hole
M6/tfix
a)
Nominal diameter
of drill bit
Stop drill bit b)
HK+
M8/tfix
I M6
42
d0 [mm]
Tmax [Nm]
Anchor size
Setting tool
Clearance hole
Max. torque moment
a)
b)
284
HK L
M8/tfix
I M6
37
Clearance hole
M6/tfix
h1 [mm]
SDS+
HSM 6 / HSM 8 / HSM I
tfix
tfix
M6
df [mm]
7
9
9
Setting tool
I M8
HSM-I
d0 [mm]
12
I M8
h1 [mm]
HSM I
M8
SDS 2
HSM 6 / HSM 8 / HSM I
tfix
tfix
M6
7
I M8
HSM I
M8
12
HK8
I M10
I M12 I M8/M10
43
8
SDS 8 x 43
HSM 8 I HSM 8 I HSM 8 I HSM 8 I
M8
M10
M12
M8
df [mm]
12
14
16
14
Tmax [Nm]
10
1 / 2009
HK | Ceiling anchor
HK +
hmin [mm]
hef [mm]
HK L
80
31
36
Critical spacing
scr [mm]
200
ccr [mm]
150
a)
HK 8
36
The critical spacing (critical edge distance) shall be kept. Smaller spacing (edge distance) than critical spacing
(critical edge distance) are not covered by the design method.
1 / 2009
285
HPD
Aerated concrete anchor
Autoclaved
aerated
concrete
Sprinkler
approved
Benefits
- anchor for autoclaved aerated
concrete
- maximum use of base material
capacity
- setting without drilling
Fire
resistance
Approvals / certificates
Description
Allgemeine bauaufsichtliche
Zulassung (national approval in
Germany) a)
Fire test report
Assessment report (fire)
Sprinkler
Authority / Laboratory
DIBt, Berlin
Z-21.1-1729 / 2003-12-10
IBMB, Braunschweig
warringtonfire
VdS, Cologne
UB 3077/3602-Nau- / 2002-02-05
WF 166402 / 2007-10-26
G 4981083 / 2008-01-01
286
1 / 2009
HPD
Aerated concrete anchor
Recommended loads
Non-cracked AAC a)
Anchor size
Cracked AAC
M6
M8
M10
M6
M8
M10
AAC 2
[kN]
0,4
0,4
0,6
AAC 4, AAC 6
[kN]
0,8
0,8
1,2
P 3,3
[kN]
0,6
0,6
0,8
P 4,4
[kN]
0,8
0,8
1,2
P 3,3
[kN]
0,6
0,6
0,8
P 4,4
[kN]
0,8
0,8
1,2
AAC 2
[kN]
0,4
0,4
0,6
AAC 4, AAC 6
[kN]
0,8
0,8
1,2
P 3,3
[kN]
0,6
0,6
0,8
P 4,4
[kN]
0,8
0,8
1,2
P 3,3
[kN]
0,6
0,6
0,8
P 4,4
[kN]
0,8
0,8
1,2
AAC 2
[kN]
0,6
0,6
0,8
AAC 4, AAC 6
[kN]
1,1
1,1
1,7
P 3,3
[kN]
0,8
0,8
1,1
P 4,4
[kN]
1,1
1,1
1,7
P 3,3
[kN]
0,8
0,8
1,1
P 4,4
[kN]
1,1
1,1
1,7
a) in case of small sized AAC blocks (<= 250mm x 500mm x thickness) the recommended load has to be reduced
with a factor 0,6.
Materials
Mechanical properties of HPD
Anchor size
M6
M8
M10
[N/mm]
800
500
500
Nominal tensile strength fuk
[N/mm]
750
565
565
[N/mm]
Yield strength fyk
[N/mm]
Stressed cross-section As
[mm]
20,1
36,6
58
Moment of resistance W
[mm]
12,7
31,2
62,3
Carbon steel [Nm]
12
19
37
Char. bending resistance
M0Rk,s
Stainless steel [Nm]
11
21
42
The recommended bending moment shall be calculated by dividing the characteristic bending moment by 1,4 and
1,25
Carbon steel
Stainless steel
Carbon steel
Stainless steel
1 / 2009
287
HPD
Aerated concrete anchor
Material quality
Part
All parts
HPD
HPD (stainless steel)
Material
Carbon steel, galvanised to min. 5 m
Stainless steel
Anchor dimensions
Anchor size
M6
M8
M10
tfix,min
[mm]
tfix,max
[mm]
30
20
30
Anchor diameter
d1
[mm]
9,8
11,8
13,8
lc
[mm]
70
ld
[mm]
12
Setting
Installation equipment
Anchor size
Setting tools
288
M6/10
HPE-G
6/10
M6/30
HPE-G
6/30
M8/10
HPE-G
8/10
M8/20
HPE-G
8/20
M10/10
M10/30
HPE-M
10/10
HPE-M
10/30
1 / 2009
HPD
Aerated concrete anchor
Setting instruction
Setting details: depth of drill hole h1 and effective anchorage depth hef
tfix
hef
hmin
M8
M10
df
[mm]
12
hef
[mm]
62
62
62
Torque moment
Tinst
[Nm]
Width across
SW
[mm]
10
13
17
1 / 2009
289
HPD
Aerated concrete anchor
M8
M10
175
10 / 20
600
[mm]
[mm]
[mm]
M12
[mm]
50
55
55
[mm]
60
50
55
cmin,1
smin,anchor
cmin,2
smin,group
hmin
cmin,1
cmin,1
smin,group
smin,anchor
cmin,1
Allowable fixing area for anchors of roof
and ceiling plates according DIN 4223
290
Width
of plate
1 / 2009
HPD
Aerated concrete anchor
1 / 2009
291
Sprinkler
approved
Fire
resistance
Anchor version
Benefits
HKH
Corrosion
resistance
Approvals / certificates
Description
Authority / Laboratory
Allgemeine bauaufsichtliche
Zulassung (national approval in
Germany for single point
fastening)a)
DIBt, Berlin
Z-21.1-1722 / 2007-03-14
DIBt, Berlin
Z-21.1-1722 / 2007-03-14
IBMB, Braunschweig
warringtonfire
WF 166402 / 2007-10-26
Sprinkler
VdS, Cologne
G 4961028 / 2006-09-05
a) All data given in this section according DIBt approval Z-21.1-1722, issue 2007-03-14.
292
1 / 2009
Recommended loads
Anchor size
M6
M8
M10
M6
M8
M10
M6
M8
M10
> 25
Tensile, Frec
[kN]
> 30
> 40
0,7
0,7
0,9
0,9
0,9
1,2
2,0
2,0
3,0
[kN]
0,9
0,9
1,2
1,2
1,2
1,6
2,5
2,5
4,0
[kN]
1,1
1,1
1,5
1,5
1,5
2,0
3,3
3,3
5,0
[kN]
1,2
1,2
1,6
1,6
1,6
2,1
3,5
3,5
5,3
[kN]
1,5
1,5
2,0
2,0
2,0
2,6
4,4
4,4
6,6
[kN]
1,9
1,9
2,5
2,5
2,5
3,3
5,5
5,5
8,3
The given loads are valid for tensile load, shear load and all load directions
All data applies to:
- Hollow decks, classification > C 45/55
- Hollow decks where bH < 4,2 bst
Materials
Mechanical properties of HKH
Anchor size
Nominal tensile strength fuk
admissible bending
resistance
Carbon steel
Stainless steel
Carbon steel
Stainless steel
[N/mm]
[N/mm]
[Nm]
[Nm]
M6
800
700
7,0
4,9
M8
500
700
10,7
12,1
M10
500
700
21,4
24,1
Material quality
Part
All parts
1 / 2009
Material
galvanised to min. 5 m
Stainless steel A4
293
Anchor dimensions
Anchor size
M6
M8
M10
tfix
[mm]
< 10
< 10
< 10
l1
[mm]
lh1
[mm]
10
10
10
[mm]
9,8
11,8
13,8
[mm]
86
88
93
lh
[mm]
55
Setting
Installation equipment
M6
M8
M10
10
12
14
Drill bit
TE-CX-10
TE-CX-12
TE-CX-14
Rotary hammer
Anchor size
Diameter of drill bit
Setting tools
Machine setting tool
294
d0
[mm]
Torque wrench
available
1 / 2009
Setting instruction
Setting mark
must be visible
M6
M8
M10
12
14
16
df
[mm]
hs
[mm]
55 to 65
Thickness of fixture
tfix
[mm]
10
Torque moment
Tinst
[Nm]
10
20
Width across
SW
[mm]
10
13
17
M8
150
100
M10
[mm]
[mm]
[mm]
300
M6
a)
c>
cmin >
a) For edge distance < 150 mm the recommended load has to be reduced with F = 0,75Frec
Specification: bH 4,2 bst
1 / 2009
295
HTB
Hollow wall metal anchor
Benefits
- Ingenious and strong for hollow
base materials
- Convincing simplicity when
setting
- Technical superiority with up to
92mm fixing thickness
- Load carried by strong metal
channel and screw
drywall
Characteristic resistance
Anchor size
Gypsum board
Thickness 10 mm
Gypsum board
Thickness 12,5 mm
Gypsum board
Thickness 2x12,5 mm
Fibre reinforced gypsum board
Thickness 10 mm
Fibre reinforced gypsum board
Thickness 12,5 mm
Hollow decks
Cavity to surface thickness 30,0 mm
Hollow brick "Parpaing Creux B40"
296
M5 / M6
NRk
[kN]
0,75
VRk
[kN]
0,45
NRk
[kN]
1,20
VRk
[kN]
0,90
NRk
[kN]
2,10
VRk
[kN]
0,90
NRk
[kN]
1,20
VRk
[kN]
1,80
NRk
[kN]
1,80
VRk
[kN]
3,00
NRk
[kN]
1,50
VRk
[kN]
NRk
[kN]
1,35
VRk
[kN]
2,70
1 / 2009
HTB
Hollow wall metal anchor
Design resistance
Anchor size
Gypsum board
Thickness 10 mm
Gypsum board
Thickness 12,5 mm
Gypsum board
Thickness 2x12,5 mm
Fibre reinforced gypsum board
Thickness 10 mm
Fibre reinforced gypsum board
Thickness 12,5 mm
Hollow decks
Cavity to surface thickness 30,0 mm
Hollow brick "Parpaing Creux B40"
M5 / M6
NRd
[kN]
0,35
VRd
[kN]
0,21
NRd
[kN]
0,56
VRd
[kN]
0,42
NRd
[kN]
0,98
VRd
[kN]
0,42
NRd
[kN]
0,56
VRd
[kN]
0,84
NRd
[kN]
0,84
VRd
[kN]
1,40
NRd
[kN]
0,70
VRd
[kN]
NRd
[kN]
0,63
VRd
[kN]
1,26
Recommended loads a)
Anchor size
Gypsum board
Thickness 10 mm
Gypsum board
Thickness 12,5 mm
Gypsum board
Thickness 2x12,5 mm
Fibre reinforced gypsum board
Thickness 10 mm
Fibre reinforced gypsum board
Thickness 12,5 mm
Hollow decks
Cavity to surface thickness 30,0 mm
Hollow brick "Parpaing Creux B40"
M5 / M6
Nrec
[kN]
0,25
Vrec
[kN]
0,15
Nrec
[kN]
0,40
Vrec
[kN]
0,30
Nrec
[kN]
0,70
Vrec
[kN]
0,30
Nrec
[kN]
0,40
Vrec
[kN]
0,60
Nrec
[kN]
0,60
Vrec
[kN]
1,00
Nrec
[kN]
0,50
Vrec
[kN]
Nrec
[kN]
0,45
Vrec
[kN]
0,90
a) With overall global safety factor = 3 to the characteristic loads and a partial safety factor of = 1,4 to the
design values
1 / 2009
297
HTB
Hollow wall metal anchor
Materials
Material quality
Part
Metal channel
Cap washer
Legs
Screw
Material
Carbon steel galvanized to 5 microns
Polypropylene copolymer
High impact polystyrene
Carbon steel galvanized to 3 microns
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
M5 / M6
TE2 TE16
Screwdriver
Setting instruction
Setting details:
298
1 / 2009
HTB
Hollow wall metal anchor
M5
M6
do
[mm]
13 - 14
min
h + tfix
[mm]
10
max
h + tfix
[mm]
92
[mm]
48
Screw length
[mm]
12 + h + tfix
Screw size
Tightening torque
Tinst
1 / 2009
[Nm]
M5
M6
299
Concrete
Solid brick
Hollow brick
- for insulating up to 15 cm
- simple setting
Insulation
Recommended loads a)
IDP
Concrete C16/20
Nrec
[kN]
0,14
Nrec
[kN]
0,14
Nrec
[kN]
0,14
Nrec
[kN]
0,04 b)
Nrec
[kN]
0,04
a) With overall global safety factor = 5 to the characteristic loads and a partial safety factor of = 1,4 to the
design values.
b) Drilling without hammering
300
1 / 2009
Mineral wool
density 150
kg/m3
thickness 150
mm
thickness 100
mm
thickness 150
6
mm
The data is only valid if no further material is applied on the insulation, e.g. plaster. Otherwise number of fasteners
have to be increased.
Materials
Material quality
Part
Plastic sleeve
Material
Polypropylene
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
IDP
TE2 TE16
Hammer
Setting instruction
1 / 2009
301
Setting details: depth of drill hole h1 and effective anchorage depth hnom
0/2
2/4
4/6
6/8
8/10
10/12
13/15
do
[mm]
dcut
[mm]
8,45
h1
[mm]
l tfix + 10 mm 40mm
hnom
[mm]
25
Anchor length
[mm]
50
70
90
110
130
150
180
tfix
[mm]
20
40
60
80
100
120
150
Installation temperature
302
[C]
0 to +40
1 / 2009
1 / 2009
303
IZ | Insulation fastener
IZ Insulation fastener
Anchor version
IZ
Concrete
Solid brick
Hollow brick
Benefits
- Insulation fastener esp. for
plastered surfaces
- 30mm setting depth
- perfect flush setting
Insulation
Recommended loads
IZ
Concrete C16/20
Solid clay brick
Mz 12 2,0
Solid sand-lime brick
KS 12 1,8
Hollow clay brick
Hlz 12 1,0
Hollow sand-lime brick
KSL 12 1,4
a) Drilling without hammering
Nrec
[kN]
0,2
Nrec
[kN]
0,2
Nrec
[kN]
0,2
Nrec
[kN]
0,13a)
Nrec
[kN]
0,17
0,15
thickness 40 mm
0,15
thickness 40 mm
0,15
thickness 40 mm
0,167
304
1 / 2009
IZ | Insulation fastener
Materials
Material quality
Part
Anchor sleeve
Expansion pin
Material
Polypropylene
Polyamide, fibre reinforced 50%,
Anchor dimensions
Anchor size
IZ
hD,min
[mm]
hD,max
[mm]
180
dnom
[mm]
l1,min
[mm]
70
l1,max
[mm]
210
l2,min
[mm]
65
l2,max
[mm]
205
l1
hnom
hef
60
dnom
l2
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
1 / 2009
IDP
TE2 TE16
Hammer, stepped-drill TE-C 8/12-370 is necessary when ttol > 30mm
305
IZ | Insulation fastener
Setting instruction
Setting details:
hef
ttol
hD
hnom
h1
h
306
1 / 2009
IZ | Insulation fastener
Setting details IZ
Anchor version
Nominal diameter of drill bit
do
[mm]
dcut
[mm]
8,45
h1
[mm]
50
hef
[mm]
30
hnom
[mm]
40
[C]
0 to +40
[mm]
[mm]
[mm]
100
100
100
Installation temperature
Setting parameters
Anchor size
Minimum base material thickness
Spacing
Edge distance
hmin
s
c
cmin
smin
cmin
1 / 2009
smin
hmin
307
IDMS / IDMR
Insulation fastener
Concrete
Solid brick
Hollow brick
Benefits
- for insulating material up to 15 cm
thick
- a non-flammable metal fastener
- IDMS-T / IDMR-T insulation plate
for non self-supporting insulation
material
Fire
resistance
Insulation
Approvals / certificates
Description
Fire test report
Authority / Laboratory
IBMB, Braunschweig
Recommended loads
IDMS / IDMR
Concrete C16/20
Nrec
[kN]
0,1
Nrec
[kN]
0,1
Nrec
[kN]
0,1
Nrec
[kN]
0,04a)
Nrec
[kN]
0,04
308
1 / 2009
IDMS / IDMR
Insulation fastener
density
thickness
40 kg/m3 150 mm
thickness
100 mm
Mineral wool
density
150
kg/m3
thickness
8
150 mm
The data is only valid if no further material is applied on the insulation, e.g. plaster. Otherwise number of fasteners
has to be increased.
Materials
Material quality
Part
IDMS
IDMR
Material
Carbon steel, galvanised to 16 m
Stainless steel, grade 1.4301
Setting
installation equipment
IDMS / IDMR
Rotary hammer
Other tools
TE2 TE16
Hammer
Setting instruction
1 / 2009
309
IDMS / IDMR
Insulation fastener
Setting details: depth of drill hole h1 and effective anchorage depth hnom
0/3
3/6
6/9
9/12
12/15
do
[mm]
dcut
[mm]
8,45
h1
[mm]
l tfix + 10 mm 60mm
hnom
[mm]
Anchor length
[mm]
80
110
140
170
200
tfix
[mm]
30
60
90
120
150
hmin
s
c
[mm]
[mm]
[mm]
l tfix
50
30 50
Setting parameters
Anchor size
Minimum base material thickness
Spacing
Edge distance
310
100
100
100
1 / 2009
IDMS / IDMR
Insulation fastener
1 / 2009
311
Adhesive anchoring
systems
312
1 / 2009
Adhesive anchoring
systems
1 / 2009
313
Benefits
Hilti
HVU-TZ foil
capsule
HAS-TZ
HAS-RTZ
HAS-HCRTZ
rod
Concrete
Tensile
zone
Fire
resistance
Corrosion
resistance
High
corrosion
resistance
Fatigue
Shock
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Approval for shockproof fastenings
in civil defence installations
Approval for dynamic loads
Fire test report ZTV-Tunnel
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
DIBt, Berlin
IBMB, Braunschweig
IBMB, Brunswick
warringtonfire
Z-21.3-1692 / 2007-11-04
UB 3357/0550-2 / 2001-06-26
UB 3357/0550-1 / 2001-04-17
WF 166402 / 2007-10-26
314
1 / 2009
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M10x75
M12x95
M16x105
M16x125
Embedment depth [mm]
75
95
105
125
Base material thickness [mm]
150
190
210
250
M20x170
170
340
Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HVZ
Anchor size
Non cracked concrete
Tensile NRu,m HVZ
M10x75
[kN]
36,8
53,3
72,4
94,1
149,2
Shear VRu,m
HVZ
Cracked concrete
Tensile NRu,m HVZ
[kN]
18,9
28,4
53,6
53,6
92,4
[kN]
31,2
44,4
51,6
67,1
106,4
Shear VRu,m
[kN]
18,9
28,4
53,6
53,6
92,4
HVZ
32,8
40,0
54,3
70,6
111,9
Shear VRk
HVZ
Cracked concrete
Tensile NRk
HVZ
[kN]
18,0
27,0
51,0
51,0
88,0
[kN]
23,4
33,3
38,7
50,3
79,8
Shear VRk
[kN]
18,0
27,0
51,0
51,0
88,0
HVZ
M10x75
[kN]
21,9
26,7
36,2
47,1
74,6
Shear VRd
HVZ
Cracked concrete
Tensile NRd
HVZ
[kN]
14,4
21,6
40,8
40,8
70,4
[kN]
15,6
22,2
25,8
33,5
53,2
Shear VRd
[kN]
14,4
21,6
40,8
40,8
70,4
HVZ
15,6
19,0
25,9
33,6
53,3
Shear Vrec
HVZ
Cracked concrete
Tensile Nrec
HVZ
[kN]
10,3
15,4
29,1
29,1
50,3
[kN]
11,1
15,9
18,4
24,0
38,0
Shear Vrec
[kN]
10,3
15,4
29,1
29,1
50,3
HVZ
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
315
Base material
temperature
Temperature range I
-40 C to +80 C
Materials
Mechanical properties of HAS-TZ
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
Moment of
resistance W
M10x75
HAS-(R)
(HCR)TZ
[N/mm]
800
HAS-(R)
(HCR)TZ
[N/mm]
640
tension
[mm]
44,2
63,6
113
113
227
shear
[mm]
50,3
73,9
141
141
245
HAS-(R)
(HCR)TZ
[mm]
50,3
89,6
236
236
541
M16x105
105
M16x125
125
M20x170
170
Material quality
Part
Material
carbon steel
strength class 8.8 EN 20898-1
stainless steel
1.4401 and 1.4571 EN 10088
high corrosion resistance steel
1.4529 and 1.4547 EN 10088
HAS-TZ
HAS-R-TZ
HAS-HCR-TZ
Anchor dimensions
Anchor size
Anchor embedment depth
316
[mm]
M10x75
75
M12x95
95
1 / 2009
Setting
installation equipment
Anchor size
Rotary hammer
Tools
M10x75
M12x95
M16x105
TE 2 TE 16
Setting tools
M16x125
M20x170
TE 40 TE 70
Setting instruction
Dry and water-saturated concrete, hammer drilling
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
1 / 2009
317
Setting details
Anchor size
Nominal diameter of
drill bit
M10x75
d0
[mm]
12
14
18
18
25
Diameter of element
[mm]
10
12
16
16
20
Effective anchorage
depth
hef
[mm]
75
95
105
125
170
h0
[mm]
90
110
125
145
195
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Non cracked concrete
Minimum spacing
Minimum edge
distance
Cracked concrete
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
Critical edge distance
for splitting failure
Critical spacing for
concrete cone failure
Critical edge distance
for concrete cone
failure
Torque moment c)
hmin a)
[mm]
150
190
210
250
340
df
[mm]
12
14
18
18
22
smin
[mm]
50
60
70
70
80
cmin
[mm]
50
60
70
70
80
smin
[mm]
50
60
70
70
80
cmin
[mm]
50
70
85
85
80
scr,sp
[mm]
2 ccr,sp
ccr,sp
[mm]
1,5 hef
90
150
scr,N
2 ccr,N
ccr,N b)
1,5 hef
Tmax
[Nm]
40
50
90
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
318
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
23,3
34,0
60,0
60,0
121,3
Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Anchor size
Embedment depth hef [mm]
Non cracked concrete
N0Rd,p Temperature range I
Cracked concrete
N0Rd,p Temperature range I
1 / 2009
21,9
26,7
36,2
47,1
74,6
[kN]
15,6
22,2
25,8
33,5
53,2
319
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Data according ETA-03/0032, issue 2008-09-29
Anchor size
M10x75
M12x95
M16x105
M16x125
M20x170
N0Rd,c Non cracked concrete [kN]
21,9
31,2
36,2
47,1
74,6
N0Rd,c Cracked concrete
[kN]
15,6
22,2
25,8
33,5
53,2
a) Splitting resistance must only be considered for non-cracked concrete
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0.1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0,5(1 + s/scr,N) 1
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0,5(1 + s/scr,sp) 1
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
320
1 / 2009
Influence of reinforcement
hef [mm]
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4
[kN]
[kN]
16,0
24,0
44,8
44,8
78,4
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
M8
Cracked concrete
M8
V0Rd,c
[kN]
4,7
6,5
8,6 13,7 20,9 29,7 3,3
a) For anchor groups only the anchors close to the edge must be considered.
6,1
9,8
15,0
21,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
1 / 2009
C 45/55
C 50/60
1,48
1,55
321
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
322
1 / 2009
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-03/0032, issue 2008-09-29
Anchor size
M10x75
M12x95
M16x105
M16x125
M20x170
Embedment depth
hef = [mm]
75
95
105
125
170
Base material thickness hmin= [mm]
150
190
210
250
340
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HVZ
HVZ-R
[kN]
21,9
26,7
36,2
47,1
74,6
HVZ-HCR
Cracked concrete
HVZ
[kN]
15,6
22,2
25,8
33,5
53,2
HVZ-R
HVZ-HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
HVZ
[kN]
14,4
21,6
40,8
40,8
70,4
HVZ-R
[kN]
16,0
24,0
44,8
44,8
78,4
HVZ-HCR
1 / 2009
323
324
1 / 2009
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-03/0032, issue 2008-09-29
Anchor size
M10x75
M12x95
M16x105
M16x125
M20x170
Embedment depth
hef = [mm]
75
95
105
125
170
Base material thickness hmin= [mm]
150
190
210
250
340
Tensile Nrec: single anchor, no edge effects
Non cracked concrete
HVZ
HVZ-R
[kN]
15,6
19,0
25,9
33,6
53,3
HVZ-HCR
Cracked concrete
HVZ
[kN]
11,1
15,9
18,4
24,0
38,0
HVZ-R
HVZ-HCR
Shear Vrec: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
HVZ
[kN]
10,3
15,4
29,1
29,1
50,3
HVZ-R
[kN]
11,4
17,1
32,0
32,0
56,0
HVZ-HCR
1 / 2009
325
326
1 / 2009
1 / 2009
327
Benefits
Hilti
HVU foil capsule
HAS
HAS-R
HAS-HCR rod
HAS-E
HAS-E R
HAS-E HCR rod
Concrete
Small edge
distance
and spacing
Fire
resistance
Fatigue
Corrosion
resistance
High
corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
Authority / Laboratory
DIBt, Berlin
IBMB, Braunschweig
IBMB, Braunschweig
warringtonfire
328
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
M20
M24
M27
Typical embedment depth [mm]
80
90
110
125
170
210
240
Base material thickness [mm]
110
120
140
165
220
270
300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values
calculated according to the simplified design method.
M30
270
340
can be
Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HAS 5.8
Anchor size
M8
M30
Tensile NRu,m
HAS
[kN]
17,9
27,3
39,9
75,6
117,6
168,0
250,3
298,7
Shear VRu,m
HAS
[kN]
8,9
13,7
20,0
37,8
58,8
84,0
182,7
221,6
M8
M30
Tensile NRk
HAS
[kN]
17,0
26,0
38,0
60,0
111,9
140,0
187,8
224,0
Shear VRk
HAS
[kN]
8,5
13,0
19,0
36,0
56,0
80,0
174,0
211,0
M8
M30
HAS
[kN]
11,3
17,3
25,3
40,0
74,6
93,3
125,2
149,4
Shear VRd
HAS
[kN]
6,8
10,4
15,2
28,8
44,8
64,0
139,2
168,8
Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HAS 5.8
Anchor size
M8
M30
Tensile Nrec
HAS
[kN]
8,1
12,4
18,1
28,6
53,3
66,7
89,4
106,7
Shear Vrec
HAS
[kN]
4,9
7,4
10,9
20,6
32,0
45,7
99,4
120,6
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
Base material
temperature
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
329
Materials
Mechanical properties of HAS
Anchor size
HAS-(E)
Nominal
HAS-(E)F
tensile
strength fuk HAS (E)R
HAS (E)HCR
HAS-(E)
HAS-(E)F
Yield
strength fyk HAS (E)R
HAS (E)HCR
Stressed
crossHAS
section As
Moment of
resistance HAS
W
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
500
800
700
800
400
640
450
600
M30
800
800
500
640
640
210
-
[mm]
32,8
52,3
76,2
144
225
324
427
519
[mm]
31,2
62,3
109
277
541
935
1387
1874
Material quality
Part
Threaded rod
HAS-(E) M8-M24
Threaded rod
HAS-(E)F M8-M30
HAS-(E) M27+M30
Threaded rod
HAS-(E)R
Threaded rod
HAS-(E)HCR
Washer
ISO 7089
Nut
EN ISO 4032
330
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Strength class 8.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Stainless steel grade A4, A5 > 8% ductile
strength class 70 for M24 and class 50 for M27 to M30, EN ISO 3506-1,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
M24: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439;
1.4362
High corrosion resistant steel, EN 10088: 1.4529; 1.4565
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
hot dipped galvanized 45 m, EN ISO 10684
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
1 / 2009
Anchor dimensions
M30
M30x270
M27
M27x240
M24
M24x210
M20
M20x170
[mm]
M16
M16x125
M12
M12x110
Anchor rod
HAS-E,
HAS-R, HAS-ER
HAS-HCR
M10
M10x90
M8
M8x80
Anchor size
80
90
110
125
170
210
240
270
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
M8
M10
M12
M16
M20
M24
M27
TE 2 TE 16
TE 40 TE 70
blow out pump or compressed air gun, setting tools
M30
Setting instruction
Dry and water-saturated concrete, hammer drilling
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
1 / 2009
331
Setting details
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
Critical edge distance
for splitting failure
Temperature range I
Critical spacing for
concrete cone failure
Critical edge distance
for concrete cone
failure
Torque moment b)
M8
d0
[mm]
10
12
14
18
24
28
30
35
hef,min
[mm]
80
90
110
125
170
210
240
270
hmin a)
[mm]
110
120
140
170
220
270
300
340
df
[mm]
12
14
18
22
26
30
33
smin
[mm]
40
45
55
65
90
120
130
135
cmin
[mm]
40
45
55
65
90
120
130
135
scr,sp
2 ccr,sp
hmin
[mm]
140
160
210
210
340
370
480
540
ccr,sp
[mm]
160
180
220
250
340
420
480
540
hmin
[mm]
160
180
220
250
340
420
480
540
ccr,sp
[mm]
100
130
180
180
340
340
480
540
200
270
300
scr,N
2 ccr,N
ccr,N
1.5 hef
Tmax
[Nm]
10
20
40
80
150
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
332
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
1 / 2009
[kN]
[kN]
[kN]
[kN]
M8
11,1
17,7
12,4
17,7
333
Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Anchor size
Typical embedment depth
hef,typ [mm]
N0Rd,p Temperature range I
[kN]
0
N Rd,p Temperature range II [kN]
N0Rd,p Temperature range III [kN]
M8
80
90
110
125
170
200
210
270
16,7
13,3
6,0
23,3
16,7
8,0
33,3
26,7
10,7
40,0
33,3
16,7
76,7
50,0
26,7
93,3
76,7
40,0
133,3
93,3
50,0
166,7
113,3
50,0
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Data according ETA-05/0255/0256/0257, issue 2006-01-20
Anchor size
M8
M10
M12
M16
M20
M24
M27
M30
N0Rd,c
[kN]
24,1
28,7
38,8
47,1
74,6
102,5
125,2
149,4
a) Splitting resistance must only be considered for non-cracked concrete
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0.1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0.7 + 0.3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0.5(1 + c/ccr,N)
334
1 / 2009
0,1
s/scr,sp
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0.5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0.5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
40
50
a)
60
a)
a)
70
80
a)
a)
90
100
a)
0.7
fre,N = 0.5 + hef/200mm 1
0.75
0.8
0.85
0.9
0.95
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4
[kN]
[kN]
[kN]
[kN]
M8
6,6
10,6
7,5
10,6
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
1 / 2009
335
M8
M10
M12
M16
M20
M24
M27
M30
V Rd,c
[kN]
2,4
3,1
4,6
6,6
12,3
a) For anchor groups only the anchors close to the edge must be considered.
20,9
25,0
28,0
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
336
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
1 / 2009
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
1 / 2009
337
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-05/0255/0256/0257, issue 2006-01-20
Anchor size
M8
M10
M12
M16
M20
M24
M27
M30
Embedment depth
hef = [mm]
80
90
110
125
170
210
240
270
Base material thickness hmin= [mm]
110
120
140
170
220
270
300
340
Tensile NRd: single anchor, no edge effects
HAS -(E)
[kN]
11,3
17,3
25,3
40,0
74,6
93,3
125,2
149,4
HAS -(E)F
[kN]
16,7
23,3
33,3
40,0
74,6
93,3
125,2
149,4
HAS (-E)-R
[kN]
12,3
19,8
28,3
40,0
74,6
93,3
90,4
109,6
HAS (-E)-HCR
[kN]
12,3
19,8
28,3
40,0
74,6
93,3
Shear VRd: single anchor, no edge effects, without lever arm
HAS -(E)
[kN]
6,8
10,4
15,2
28,8
44,8
64,0
139,2
168,8
HAS -(E)F
[kN]
10,8
16,8
24,4
46,4
72,0
102,4
139,2
168,8
HAS (-E)-R
[kN]
7,7
11,5
17,3
32,7
50,6
71,8
54,0
66,0
HAS (-E)-HCR
[kN]
7,7
11,5
17,3
32,7
50,6
71,8
-
M30
270
540
135
79,7
28,0
338
1 / 2009
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-05/0255/0256/0257, issue 2006-01-20
Anchor size
M8
M10
M12
M16
M20
M24
M27
M30
Embedment depth
hef = [mm]
80
90
110
125
170
210
240
270
Base material thickness hmin= [mm]
110
120
140
170
220
270
300
340
Tensile Nrec: single anchor, no edge effects
HAS -(E)
[kN]
8,1
12,4
18,1
28,6
53,3
66,7
89,4
106,7
HAS -(E)F
[kN]
11,9
16,7
23,8
28,6
53,3
66,7
89,4
106,7
HAS (-E)-R
[kN]
8,8
14,1
20,2
28,6
53,3
66,7
64,6
78,3
HAS (-E)-HCR
[kN]
8,8
14,1
20,2
28,6
53,3
66,7
Shear Vrec: single anchor, no edge effects, without lever arm
HAS -(E)
[kN]
4,9
7,4
10,9
20,6
32,0
45,7
99,4
120,6
HAS -(E)F
[kN]
7,7
12,0
17,4
33,1
51,4
73,1
99,4
120,6
HAS (-E)-R
[kN]
5,5
8,2
12,4
23,4
36,2
51,3
38,6
47,1
HAS (-E)-HCR
[kN]
5,5
8,2
12,4
23,4
36,2
51,3
-
M30
270
540
135
56,9
20,0
339
Benefits
Hilti
HVU foil capsule
HIS-(R)N sleeve
Concrete
Small edge
distance
and spacing
Fire
resistance
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
IBMB, Braunschweig
warringtonfire
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
Embedment depth [mm]
90
110
125
170
Base material thickness [mm]
120
150
170
230
340
M20
205
270
1 / 2009
M8
M20
Tensile NRu,m
HIS-N
[kN]
26,3
48,3
70,4
123,9
114,5
Shear VRu,m
HIS-N
[kN]
13,7
24,2
41,0
62,0
57,8
M8
M20
Tensile NRk
HIS-N
[kN]
25,0
40,0
60,0
95,0
109,0
Shear VRk
HIS-N
[kN]
13,0
23,0
39,0
59,0
55,0
M8
M20
Tensile NRd
HIS-N
[kN]
16,7
26,7
40,0
63,3
74,1
Shear VRd
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
M8
M20
Tensile Nrec
HIS-N
[kN]
11,9
19,0
28,6
45,2
53,0
Shear Vrec
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
1 / 2009
341
Materials
Mechanical properties of HIS-(R)N
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
Moment of
resistance W
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
490
800
700
700
410
640
350
450
M20
460
800
700
700
375
640
350
450
HIS-(R)N
[mm]
51,5
108,0
169,1
256,1
237,6
Screw
[mm]
36,6
58
84,3
157
245
HIS-(R)N
Screw
[mm]
[mm]
145
31,2
430
62,3
840
109
1595
277
1543
541
Material quality
Part
Material
C-steel 1.0718, EN 10277-3
internally threaded sleeves a)
HIS-N
steel galvanized 5m EN ISO 4042
internally threaded sleeves b)
stainless steel 1.4401 and 1.4571 EN 10088
HIS-RN
a) related fastening screw:
strength class 8.8 EN ISO 898-1, A5 > 8% Ductile
steel galvanized 5m EN ISO 4042
b) related fastening screw:
strength class 70 EN ISO 3506-1, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 EN 10088
Anchor dimensions
Anchor size
Internal sleeve HIS-(R)N
Anchor embedment depth
[mm]
M8
M8x90
90
M10
M10x110
110
M12
M12x125
125
M16
M16x170
170
M20
M20x205
205
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
342
M8
M10
M12
M16
TE2 TE16
TE40 TE70
blow out pump or compressed air gun, setting tools
M20
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
1 / 2009
343
Setting details
Anchor size
Nominal diameter of
drill bit
Diameter of element
Effective anchorage
and drill hole depth
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Thread engagement
length; min - max
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
Critical edge distance
for splitting failure
Temperature range I
Critical spacing for
concrete cone failure
Critical edge distance
for concrete cone
failure
Torque moment b)
M8
d0
[mm]
14
18
22
28
32
[mm]
12,5
16,5
20,5
25,4
27,6
hef
[mm]
90
110
125
170
205
hmin a)
[mm]
120
150
170
230
270
df
[mm]
12
14
18
22
hs
[mm]
8-20
10-25
12-30
16-40
20-50
smin
[mm]
40
45
60
80
125
cmin
[mm]
40
45
60
80
125
scr,sp
2 ccr,sp
hmin
[mm]
120
150
180
250
350
ccr,sp
[mm]
90
150
250
340
410
hmin
[mm]
220
250
340
410
ccr,sp
[mm]
110
125
170
250
80
150
scr,N
2 ccr,N
ccr,N
1.5 hef
Tmax
[Nm]
10
20
40
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
344
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
[kN]
M8
16,8
13,9
Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Anchor size
Embedment depth
hef [mm]
N0Rd,p Temperature range I
[kN]
N0Rd,p Temperature range II [kN]
N0Rd,p Temperature range III [kN]
1 / 2009
M8
90
110
125
170
205
16,7
13,3
6,0
26,7
23,3
10,7
40,0
33,3
13,3
63,3
50,0
26,7
93,3
63,3
33,3
345
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Data according ETA-05/0255/0256, issue 2006-01-20
Anchor size
M8
M10
M12
M16
M20
N0Rd,c
[kN]
28,7
38,8
47,1
74,6
98,8
a) Splitting resistance must only be considered for non-cracked concrete
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0.1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0.7 + 0.3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0.5(1 + c/ccr,N)
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0.5(1 + s/scr,N)
346
1 / 2009
Influence of reinforcement
hef [mm]
80
90
100
0.9 a)
fre,N = 0.5 + hef/200mm 1
0.95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
0
VRd,c = V
Rd,c
fB f f h f4
[kN]
[kN]
M8
10,4
8,3
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
M8
M10
M12
M16
M20
V Rd,c
[kN]
2,8
3,8
5,6
a) For anchor groups only the anchors close to the edge must be considered.
8,1
14,1
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
1 / 2009
C 45/55
C 50/60
1,48
1,55
347
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
348
1 / 2009
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-05/0255/0256, issue 2006-01-20
Anchor size
M8
M10
M12
M16
M20
Embedment depth
hef = [mm]
90
110
125
170
205
Base material thickness hmin= [mm]
120
150
170
230
270
Tensile NRd: single anchor, no edge effects
HIS-N
[kN]
16,7
26,7
40,0
63,3
74,1
HIS-RN
[kN]
13,9
21,9
31,6
58,8
69,2
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
[kN]
10,0
13,7
18,7
28,6
M20
205
350
125
43,6
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIS-(R)N
[kN]
2,8
3,8
5,6
8,1
14,1
[kN]
10,2
15,3
22,2
34,7
M20
205
270
125
51,8
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
1 / 2009
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
349
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-05/0255/0256, issue 2006-01-20
Anchor size
M8
M10
M12
M16
M20
Embedment depth
hef = [mm]
90
110
125
170
205
Base material thickness hmin= [mm]
120
150
170
230
270
Tensile Nrec: single anchor, no edge effects
HIS-N
[kN]
11,9
19,0
28,6
45,2
53,0
HIS-RN
[kN]
9,9
15,7
22,5
42,0
49,4
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
6,0
9,2
13,7
25,2
29,6
[kN]
7,2
9,8
13,4
20,4
M20
205
350
125
31,1
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
HIS-(R)N
[kN]
2,0
2,7
4,0
5,8
10,0
[kN]
7,3
11,0
15,9
24,8
M20
205
270
125
37,0
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
6,0
9,2
13,7
25,2
29,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
350
1 / 2009
1 / 2009
351
Benefits
Hilti HITRE 500-SD 330
ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
HIT-V rod
Concrete
Tensile
zone
CE
conformity
Hilti anchor
design
software
Small edge
distance
and spacing
Variable
embedment
depth
Fire
resistance
Fatigue
Corrosion
resistance
High
corrosion
resistance
European
Technical
Approval
Approvals / certificates
Description
a)
European technical approval
ES report
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
ICC evaluation service
MFPA, Leipzig
warringtonfire
352
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
M20
M24
M27
Typical embedment depth [mm]
80
90
110
125
170
210
240
Base material thickness [mm]
110
120
140
165
220
270
300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values
calculated according to the simplified design method.
M30
270
340
can be
Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Anchor size
Non cracked concrete
Tensile NRu,m HIT-V 5.8
Shear VRu,m
HIT-V 5.8
Cracked concrete
Tensile NRu,m HIT-V 5.8
Shear VRu,m
HIT-V 5.8
M8
M30
[kN]
[kN]
18,9
9,5
30,5
15,8
44,1
22,1
83,0
41,0
129,2
64,1
185,9
92,4
241,5
120,8
295,1
147,0
[kN]
[kN]
18,9
9,5
30,5
15,8
44,1
22,1
65,2
41,0
110,8
64,1
146,1
92,4
196,0
120,8
226,2
147,0
M8
[kN]
[kN]
18,0
9,0
29,0
15,0
42,0
21,0
70,6
39,0
111,9
61,0
153,7
88,0
187,8
115,0
224,0
140,0
[kN]
[kN]
16,1
9,0
22,6
15,0
31,1
21,0
44,0
39,0
74,8
61,0
109,6
88,0
132,3
115,0
152,7
140,0
M8
M30
[kN]
[kN]
12,0
7,2
19,3
12,0
28,0
16,8
33,6
31,2
53,3
48,8
73,2
70,4
89,4
92,0
106,7
112,0
[kN]
[kN]
8,9
7,2
12,6
12,0
17,3
16,8
20,9
31,2
35,6
48,8
52,2
70,4
63,0
92,0
72,7
112,0
M30
1 / 2009
353
Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Data according ETA-07/0260, issue 2009-01-12
Anchor size
M8
M10
M12
M16
M20
M24
M27
M30
Non cracked concrete
Tensile Nrec
HIT-V 5.8
[kN]
8,6
13,8
20,0
24,0
38,1
52,3
63,9
76,2
Shear Vrec
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
80,0
Cracked concrete
Tensile Nrec
HIT-V 5.8
[kN]
6,4
9,0
12,3
15,0
25,4
37,3
45,0
51,9
Shear Vrec
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +58 C
-40 C to +70 C
Materials
Mechanical properties of HIT-V / HAS
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
500
800
700
800
400
640
450
600
M30
500
800
500
700
400
640
210
400
[mm]
36,6
58,0
84,3
157
245
353
459
561
[mm]
27,0
54,1
93,8
244
474
809
1274
1706
Anchor size
HIT-V 5.8
Nominal
HIT-V 8.8
tensile
HIT-V-R
strength fuk
HIT-V-HCR
HIT-V 5.8
Yield strength HIT-V 8.8
fyk
HIT-V -R
HIT-V -HCR
Stressed
cross-section HIT-V
As
Moment of
HIT-V
resistance W
354
1 / 2009
Material quality
Part
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Strength class 8.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Stainless steel grade A4, A5 > 8% ductile
strength class 70 for M24 and class 50 for M27 to M30, EN ISO 3506-1,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439;
1.4362
High corrosion resistant steel, EN 10088: 1.4529; 1.4565
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
hot dipped galvanized 45 m, EN ISO 10684
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
Threaded rod
HIT-V(F) 5.8
Threaded rod
HIT-V(F) 8.8
Threaded rod
HIT-V-R
Threaded rod
HIT-V-HCR
Washer
ISO 7089
Nut
EN ISO 4032
Anchor dimensions
Anchor size
Anchor embedment depth
[mm]
M8
80
Anchor rod
HIT-V, HIT-V-R, HIT-V-HCR
M10
90
M12
110
M16
125
M20
170
M24
210
M27
240
M30
270
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
TE2 TE16
TE40 TE70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
355
Setting instruction
Dry and water-saturated concrete, hammer drilling
356
Setting details
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
range a)
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
M8
M30
d0
[mm]
10
12
14
18
24
28
30
35
hef,min
[mm]
40
40
48
64
80
96
108
120
hef,max
[mm]
160
200
240
320
400
480
540
600
hmin
[mm]
df
[mm]
12
14
18
22
26
30
33
smin
[mm]
40
50
60
80
100
120
135
150
cmin
[mm]
40
50
60
80
100
120
135
150
200
270
300
hef + 30 mm
100 mm
hef + 2 d0
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1,5 hef
Tmax
[Nm]
10
20
40
80
150
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) hef,min hef hef,max (hef: embedment depth)
b) h: base material thickness (h hmin)
c) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
1 / 2009
357
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
358
[kN]
[kN]
[kN]
[kN]
M8
12,0
19,3
13,9
19,3
M30
187,3
299,3
98,3
187,1
1 / 2009
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance b) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size
M8
M10
M12
M16
M20
M24
M27
M30
N0Rd,c Non cracked concrete [kN]
20,1
24,0
32,4
33,6
53,3
73,2
89,4
106,7
N0Rd,c Cracked concrete
[kN]
14,3
17,1
23,1
24,0
38,0
52,2
63,7
76,1
a) Additional Hilti technical data (not part of ETA-07/0260, issue 2008-11-03):
The design values for concrete cone resistance may be increased by 20 % for anchor installation in dry
concrete (concrete not in contact with water before/during installation and curing).
b) Splitting resistance must only be considered for non-cracked concrete
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0,1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
1 / 2009
C 45/55
C 50/60
1,48
1,55
359
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N)
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
360
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
1 / 2009
[kN]
[kN]
[kN]
[kN]
M8
7,2
12,0
8,3
12,0
M30
112,0
179,2
58,8
112,0
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
M8
M10
M12
M16
M20
M24
M27
M30
[kN]
5,9
8,6
11,6
18,7
27,0
36,6
44,5
53,0
[kN]
4,2
6,1
8,2
13,2
19,2
25,9
31,5
37,5
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
1 / 2009
{h/(1,5 c)}
1/2
361
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
362
1 / 2009
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-07/0260, issue 2009-01-12
Anchor size
M8
M10
M12
M16
M20
M24
M27
Embedment depth
hef,1 = [mm]
48
60
72
96
120
144
162
Base material thickness hmin= [mm]
100
100
102
132
168
200
222
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN]
9,3
13,0
17,1
22,6
31,6
41,6
49,6
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN]
5,4
8,4
11,3
16,1
22,5
29,6
35,3
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
92,0
HIT-V 8.8
[kN]
11,2
18,4
27,2
50,4
78,4
112,8
138,8
HIT-V-R
[kN]
8,3
12,8
19,2
35,3
55,1
79,5
48,3
HIT-V-HCR
[kN]
11,2
18,4
27,2
50,4
78,4
70,9
92,0
Cracked concrete
HIT-V 5.8
[kN]
6,4
12,0
16,8
31,2
48,8
70,4
92,0
HIT-V 8.8
[kN]
6,4
18,4
27,1
45,0
63,1
82,9
99,0
HIT-V-R
[kN]
6,4
12,8
19,2
35,3
55,1
79,5
48,3
HIT-V-HCR
[kN]
6,4
18,4
27,1
45,0
63,1
70,9
92,0
M30
180
250
58,1
41,4
112,0
162,6
58,8
112,0
112,0
115,9
58,8
112,0
M30
180
250
150
33,2
23,7
31,1
22,0
363
M30
180
250
150
37,1
26,4
103,9
103,9
58,8
103,9
74,1
74,1
58,8
74,1
364
M30
270
340
106,7
106,7
98,3
106,7
72,7
112,0
179,2
58,8
112,0
112,0
179,2
58,8
112,0
1 / 2009
1 / 2009
M30
270
340
150
51,4
36,7
34,8
24,7
365
M30
270
340
150
63,2
44,0
112,0
177,0
58,8
112,0
112,0
120,6
58,8
112,0
366
M30
360
430
164,3
164,3
98,3
164,3
96,9
96,9
96,9
96,9
112,0
179,2
58,8
112,0
1 / 2009
1 / 2009
M30
360
430
150
73,5
52,4
38,1
27,0
367
368
M30
360
430
150
93,5
93,5
93,5
93,5
61,1
112,0
179,2
58,8
112,0
112,0
154,6
58,8
112,0
1 / 2009
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-07/0260, issue 2009-01-12
Anchor size
M8
M10
M12
M16
M20
M24
M27
Embedment depth
hef,1 = [mm]
48
60
72
96
120
144
162
Base material thickness hmin= [mm]
100
100
102
132
168
200
222
Tensile Nrec: single anchor, no edge effects
Non cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN]
6,7
9,3
12,2
16,2
22,6
29,7
35,4
HIT-V-R
HIT-V-HCR
Cracked concrete
HIT-V 5.8
HIT-V 8.8
[kN]
3,8
6,0
8,1
11,5
16,1
21,2
25,2
HIT-V-R
HIT-V-HCR
Shear Vrec: single anchor, no edge effects, without lever arm
Non cracked concrete
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
HIT-V 8.8
[kN]
8,0
13,1
19,4
36,0
56,0
80,6
99,2
HIT-V-R
[kN]
6,0
9,2
13,7
25,2
39,4
56,8
34,5
HIT-V-HCR
[kN]
8,0
13,1
19,4
36,0
56,0
50,6
65,7
Cracked concrete
HIT-V 5.8
[kN]
4,6
8,6
12,0
22,3
34,9
50,3
65,7
HIT-V 8.8
[kN]
4,6
13,1
19,4
32,2
45,1
59,2
70,7
HIT-V-R
[kN]
4,6
9,2
13,7
25,2
39,4
56,8
34,5
HIT-V-HCR
[kN]
4,6
13,1
19,4
32,2
45,1
50,6
65,7
M30
180
250
41,5
29,6
80,0
116,1
42,0
80,0
80,0
82,8
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
369
M30
180
250
150
23,7
16,9
22,2
15,7
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
370
1 / 2009
M30
180
250
150
26,5
18,9
74,2
74,2
42,0
74,2
52,9
52,9
42,0
52,9
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
371
M30
270
340
76,2
76,2
70,2
76,2
51,9
80,0
128,0
42,0
80,0
80,0
128,0
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
372
1 / 2009
M30
270
340
150
36,7
26,2
24,9
17,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
373
M30
270
340
150
45,2
31,4
80,0
126,4
42,0
80,0
80,0
86,2
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
374
1 / 2009
M30
360
430
117,3
117,3
70,2
117,3
69,2
69,2
69,2
69,2
80,0
128,0
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
375
M30
360
430
150
52,5
37,4
27,2
19,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
376
1 / 2009
M30
360
430
150
66,8
66,8
66,8
66,8
43,6
80,0
128,0
42,0
80,0
80,0
110,4
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
377
Benefits
Hilti
HIT-RE 500-SD
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
HIS-(R)N sleeve
Concrete
Tensile
zone
Small edge
distance
and spacing
Fire
resistance
Fatigue
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
MFPA, Leipzig
warringtonfire
378
1 / 2009
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
Embedment depth [mm]
90
110
125
170
Base material thickness [mm]
120
150
170
230
M20
205
270
M8
M20
[kN]
[kN]
27,3
13,7
48,3
24,2
70,4
41,0
123,9
62,0
114,5
57,8
[kN]
[kN]
27,3
13,7
48,3
24,2
67,1
41,0
106,4
62,0
114,5
57,8
M8
M20
[kN]
[kN]
26,0
13,0
46,0
23,0
67,0
39,0
111,9
59,0
109,0
55,0
[kN]
[kN]
25,0
13,0
40,0
23,0
50,3
39,0
79,8
59,0
105,7
55,0
M8
M20
[kN]
[kN]
17,4
10,4
27,7
18,4
33,6
26,0
53,3
39,3
70,6
36,7
[kN]
[kN]
13,9
10,4
19,0
18,4
24,0
26,0
38,0
39,3
50,3
36,7
1 / 2009
379
Base material
temperature
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +58 C
-40 C to +70 C
Materials
Mechanical properties of HIS-(R)N
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
Moment of
resistance W
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
490
800
700
700
410
640
350
450
M20
460
800
700
700
375
640
350
450
HIS-(R)N
[mm]
51,5
108,0
169,1
256,1
237,6
Screw
[mm]
36,6
58
84,3
157
245
HIS-(R)N
Screw
[mm]
[mm]
145
31,2
430
62,3
840
109
1595
277
1543
541
Material quality
Part
Material
C-steel 1.0718, EN 10277-3
internally threaded sleeves a)
HIS-N
steel galvanized 5m EN ISO 4042
internally threaded sleeves b)
stainless steel 1.4401 and 1.4571 EN 10088
HIS-RN
a)
related fastening screw: strength class 8.8 EN ISO 898-1, A5 > 8% Ductile
steel galvanized 5m EN ISO 4042
b)
related fastening screw: strength class 70 EN ISO 3506-1, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 EN 10088
Anchor dimensions
Anchor size
Internal sleeve
HIS-(R)N
Anchor embedment depth
380
[mm]
M8
M10
M12
M16
M20
M8x90
M10x110
M12x125
M16x170
M20x205
90
110
125
170
205
1 / 2009
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
M8
M10
M12
M16
M20
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
Setting instruction
Dry and water-saturated concrete, hammer drilling
1 / 2009
381
382
1 / 2009
Setting details
Anchor size
Nominal diameter of
drill bit
Diameter of element
Effective anchorage
and drill hole depth
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Thread engagement
length; min - max
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
M8
M20
d0
[mm]
14
18
22
28
32
[mm]
12,5
16,5
20,5
25,4
27,6
hef
[mm]
90
110
125
170
205
hmin
[mm]
120
150
170
230
270
df
[mm]
12
14
18
22
hs
[mm]
8-20
10-25
12-30
16-40
20-50
smin
[mm]
40
45
55
65
90
cmin
[mm]
40
45
55
65
90
80
150
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1.5 hef
Tmax
[Nm]
10
20
40
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
1 / 2009
383
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
384
[kN]
[kN]
M8
17,4
13,9
M20
74,1
69,2
1 / 2009
M20
205
95,2
81,0
45,2
54,8
45,2
23,8
for anchor
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance b) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size
M8
M10
M12
M16
M20
N0Rd,c Non cracked concrete [kN]
24,0
27,7
33,6
53,3
70,6
N0Rd,c Cracked concrete
[kN]
17,1
19,8
24,0
38,0
50,3
a) Additional Hilti technical data (not part of ETA-07/0260, issue 2008-11-03):
The design values for concrete cone resistance may be increased by 20 % for anchor installation in dry
concrete (concrete not in contact with water before/during installation and curing).
b) Splitting resistance must only be considered for non-cracked concrete
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0,1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
1 / 2009
C 45/55
C 50/60
1,48
1,55
385
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
c/ccr,sp
f1,N =
0.7 + 0.3c/ccr,N
0.5(1 + c/ccr,N)
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
80
90
100
0,9 a)
fre,N = 0,5 + hef/200mm 1
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
386
[kN]
[kN]
M8
10,4
8,3
M20
36,7
41,5
1 / 2009
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
M8
M10
M12
M16
M20
[kN]
12,4
19,6
28,2
40,2
46,2
[kN]
8,8
13,9
20,0
28,5
32,7
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
1 / 2009
{h/(1,5 c)}
1/2
387
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
M8
M10
M12
M16
M20
f hef =
1,38
1,21
1,04
1,22
1,45
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)0,19
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
388
1 / 2009
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-07/0260, issue 2009-01-12
Anchor size
M8
M10
M12
M16
Embedment depth
hef = [mm]
90
110
125
170
Base material thickness hmin= [mm]
120
150
170
230
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HIS-N
[kN]
17,4
27,7
33,6
53,3
HIS-RN
[kN]
13,9
21,9
31,6
53,3
Cracked concrete
HIS-(R)N
[kN]
13,9
19,0
24,0
38,0
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
HIS-N
[kN]
10,4
18,4
26,0
39,3
HIS-RN
[kN]
8,3
12,8
19,2
35,3
M20
205
270
70,6
69,2
50,3
36,7
41,5
M20
205
270
90
32,0
22,8
17,2
12,2
1 / 2009
M20
205
270
90
40,5
28,8
36,7
41,5
389
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-07/0260, issue 2009-01-12
Anchor size
M8
M10
M12
M16
Embedment depth
hef = [mm]
90
110
125
170
Base material thickness hmin= [mm]
120
150
170
230
Tensile Nrec: single anchor, no edge effects
Non cracked concrete
HIS-N
[kN]
12,5
19,8
24,0
38,1
HIS-RN
[kN]
9,9
15,7
22,5
38,1
Cracked concrete
HIS-(R)N
[kN]
9,9
13,6
17,1
27,1
Shear Vrec: single anchor, no edge effects, without lever arm
Non cracked and cracked concrete
HIS-N
[kN]
7,4
13,1
18,6
28,1
HIS-RN
[kN]
6,0
9,2
13,7
25,2
M20
205
270
50,4
49,4
35,9
26,2
29,6
M20
205
270
90
22,9
16,3
12,3
8,7
M20
205
270
90
28,9
20,6
26,2
29,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
390
1 / 2009
1 / 2009
391
Benefits
Hilti
HIT-RE 500-SD
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
Concrete
Tensile
zone
Small edge
distance
and spacing
Variable
embedment
depth
Fire
resistance
Fatigue
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval *
Fire test report
Assessment report (fire)
*
Authority / Laboratory
DIBt, Berlin
MFPA, Leipzig
warringtonfire
392
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Data according ETA-07/0260, issue 2009-01-12
Anchor size
8
10
12
14
16
20
25
28
Typical embedment depth [mm]
80
90
110
125
125
170
210
270
Base material thickness [mm]
110
120
145
165
165
220
275
340
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values
calculated according to the simplified design method.
32
300
380
can be
Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Anchor size
Non cracked concrete
Tensile NRu,m BSt 500 S
Shear VRu,m
BSt 500 S
Cracked concrete
Tensile NRu,m BSt 500 S
Shear VRu,m
BSt 500 S
32
[kN]
[kN]
29,4
14,7
45,2
23,1
65,1
32,6
89,3
44,1
94,1
57,8
149,2
90,3
204,9
141,8
298,7
177,5
349,9
232,1
[kN]
[kN]
23,8
14,7
33,5
23,1
46,1
32,6
57,0
44,1
65,2
57,8
110,8
90,3
146,1
141,8
228,7
177,5
268,1
232,1
Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size
Non cracked concrete
Tensile NRk
BSt 500 S
Shear VRk
BSt 500 S
Cracked concrete
Tensile NRk
BSt 500 S
Shear VRk
BSt 500 S
[kN]
[kN]
28,0
14,0
42,4
22,0
58,3
31,0
70,6
42,0
70,6
55,0
111,9
86,0
153,7
135,0
224,0
169,0
262,4
221,0
[kN]
[kN]
16,1
14,0
22,6
22,0
31,1
31,0
38,5
42,0
44,0
55,0
74,8
86,0
109,6
135,0
154,4
169,0
181,0
221,0
32
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size
Non cracked concrete
Tensile NRd
BSt 500 S
Shear VRd
BSt 500 S
Cracked concrete
Tensile NRd
BSt 500 S
Shear VRd
BSt 500 S
[kN]
[kN]
16,8
9,3
23,6
14,7
32,4
20,7
39,2
28,0
33,6
36,7
53,3
57,3
73,2
90,0
106,7
112,7
125,0
147,3
[kN]
[kN]
8,9
9,3
12,6
14,7
17,3
20,7
21,4
28,0
20,9
36,7
35,6
57,3
52,2
90,0
73,5
112,7
86,2
147,3
32
Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-07/0260, issue 2009-01-12
Anchor size
8
10
12
14
16
20
25
28
32
Non cracked concrete
Tensile Nrec
BSt 500 S
[kN]
12,0
16,8
23,1
28,0
24,0
38,1
52,3
76,2
89,3
Shear Vrec
BSt 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
64,3
80,5
105,2
Cracked concrete
Tensile Nrec
BSt 500 S
[kN]
6,4
9,0
12,3
15,3
15,0
25,4
37,3
52,5
61,5
Shear Vrec
BSt 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
64,3
80,5
105,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
393
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +58 C
-40 C to +70 C
Materials
Mechanical properties of rebar BSt 500S
Anchor size
Nominal
BSt 500 S
tensile
strength fuk
Yield
BSt 500 S
strength fyk
Stressed
BSt 500 S
crosssection As
Moment of
resistance BSt 500 S
W
32
[N/mm]
550
550
550
550
550
550
550
550
550
[N/mm]
500
500
500
500
500
500
500
500
500
[mm]
50,3
78,5
113,1
153,9
201,1
314,2
490,9
615,8
804,2
[mm]
50,3
98,2
169,6
269,4
402,1
785,4
1534
2155
3217
Material quality
Part
rebar
BSt 500 S
Material
Geometry and mechanical properties according to DIN 488-2:1986 or
E DIN 488-2:2006
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
394
10
12
14
16
20
25
28
32
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
1 / 2009
395
396
1 / 2009
Setting details
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
range a)
Minimum base
material thickness
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
32
d0
[mm]
12
14
16
18
20
25
32
35
40
hef,min
[mm]
60
60
70
75
80
90
100
112
128
hef,max
[mm]
160
200
240
280
320
400
500
560
640
hmin
[mm]
smin
cmin
[mm]
hef + 30 mm
100 mm
40
50
60
70
80
100
125
140
160
[mm]
40
60
70
80
100
125
140
160
50
hef + 2 d0
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1.5 hef
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
1 / 2009
397
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
398
[kN]
8
20,0
32
315,7
1 / 2009
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance b) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-07/0260, issue 2009-01-12
Anchor size
8
10
12
14
16
20
25
28
32
N0Rd,c Non cracked concrete [kN]
20,1
24,0
32,4
39,2
33,6
53,3
73,2
106,7 125,0
N0Rd,c Cracked concrete
[kN]
14,3
17,1
23,1
28,0
24,0
38,0
52,2
76,1
89,1
a) Additional Hilti technical data (not part of ETA-07/0260, issue 2008-11-03):
The design values for concrete cone resistance may be increased by 20 % for anchor installation in dry
concrete (concrete not in contact with water before/during installation and curing).
b) Splitting resistance must only be considered for non-cracked concrete
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0,1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
1 / 2009
C 45/55
C 50/60
1,48
1,55
399
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
c/ccr,sp
f1,N =
0,7 + 0,3c/ccr,N
0,5(1 + c/ccr,N)
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N)
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
400
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
112,7
32
147,3
1 / 2009
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
32
[kN]
5,9
8,6
11,6
15,0
18,7
27,0
39,2
47,3
59,0
[kN]
4,2
6,1
8,2
10,6
13,2
19,2
27,7
33,5
41,8
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
1 / 2009
{h/(1,5 c)}
1/2
401
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
402
1 / 2009
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-07/0260, issue 2009-01-12
Anchor size
8
10
12
14
16
20
25
28
Embedment depth
hef,1 = [mm]
60
60
72
84
96
120
150
168
Base material thickness hmin= [mm]
100
100
104
120
136
170
214
238
Tensile NRd: single anchor, no edge effects
Non cracked concrete
BSt 500 S
[kN]
12,6
13,0
17,1
21,6
22,6
31,6
44,2
52,4
Cracked concrete
BSt 500 S
[kN]
6,7
8,4
11,3
14,4
16,1
22,5
31,5
37,3
Shear VRd: single anchor, no edge effects, without lever arm
Non cracked concrete
BSt 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
112,7
Cracked concrete
BSt 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
88,2
104,5
32
192
272
64,0
45,6
147,3
127,7
32
192
272
160
37,0
26,4
34,6
24,5
1 / 2009
32
192
272
160
40,9
29,1
114,4
81,6
403
32
300
380
125,0
86,2
147,3
147,3
32
300
380
160
59,5
42,4
39,3
27,9
404
32
300
380
160
73,6
49,8
147,3
142,1
1 / 2009
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
112,7
32
384
464
181,0
110,3
147,3
32
384
464
160
80,9
55,3
42,6
30,2
1 / 2009
32
384
464
160
103,0
66,3
147,3
147,3
405
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-07/0260, issue 2009-01-12
Anchor size
8
10
12
14
16
20
25
28
Embedment depth
hef,1 = [mm]
60
60
72
84
96
120
150
168
Base material thickness hmin= [mm]
100
100
104
120
136
170
214
238
Tensile Nrec: single anchor, no edge effects
Non cracked concrete
BSt 500 S
[kN]
9,0
9,3
12,2
15,4
16,2
22,6
31,6
37,4
Cracked concrete
BSt 500 S
[kN]
4,8
6,0
8,1
10,3
11,5
16,1
22,5
26,7
Shear Vrec: single anchor, no edge effects, without lever arm
Non cracked concrete
BSt 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
64,3
80,5
Cracked concrete
BSt 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
63,0
74,7
32
192
272
45,7
32,6
105,2
91,2
32
192
272
160
26,4
18,8
24,7
17,5
32
192
272
160
29,2
20,8
81,7
58,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
406
1 / 2009
32
300
380
89,3
61,5
105,2
105,2
32
300
380
160
42,5
30,3
28,1
19,9
32
300
380
160
52,6
35,6
105,2
101,5
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
407
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
64,3
80,5
32
384
464
129,3
78,8
105,2
32
384
464
160
57,8
39,5
30,5
21,6
32
384
464
160
73,6
47,4
105,2
105,2
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
408
1 / 2009
1 / 2009
409
Benefits
Hilti
HIT-RE 500
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
HAS rod
HAS-E rod
HIT-V rod
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Fire
resistance
Fatigue
Corrosion
resistance
High
corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
IBMB, Braunschweig
warringtonfire
410
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Typical embedment depth [mm]
80
90
110 125 170 210 240 270 300 330 360
Base material thickness [mm]
110 120 140 165 220 270 300 340 380 410 450
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Data according ETA-04/0027, issue 2008-11-03
Anchor size
M8
M10
M12
M16
M20
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
Tensile NRu,m
HIT-V 5.8
[kN]
18,9
30,5
44,1
Shear VRu,m
HIT-V 5.8
[kN]
9,5
15,8
22,1
41,0
64,1
M8
M10
M12
M16
M20
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
Tensile NRk
HIT-V 5.8
[kN]
18,0
29,0
42,0
Shear VRk
HIT-V 5.8
[kN]
9,0
15,0
21,0
39,0
61,0
M8
M10
M12
M16
M20
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
Tensile NRd
HIT-V 5.8
[kN]
12,0
19,3
27,7
33,6
53,3
73,2
Shear VRd
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
M8
M10
M12
M16
M20
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
Tensile Nrec
HIT-V 5.8
[kN]
8,6
13,8
19,8
24,0
38,1
52,3
63,9
76,2
Shear Vrec
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
411
Base material
temperature
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +58 C
-40 C to +70 C
Materials
Mechanical properties of HIT-V / HAS
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
500
800
700
800
400
640
450
600
M10
500
800
700
800
400
640
450
600
M12
500
800
700
800
400
640
450
600
M16
500
800
700
800
400
640
450
600
M20
500
800
700
800
400
640
450
600
M24
500
800
700
700
400
640
450
400
M27
500
800
500
700
400
640
210
400
M30
500
800
500
700
400
640
210
400
Additional Hilti
technical data
M33 M36 M39
500 500 500
800 800 800
500 500 500
500 500 500
400 400 400
640 640 640
210 210 210
250 250 250
[mm]
32,8
52,3
76,2
144
225
324
427
519
647
759
913
[mm]
36,6
58,0
84,3
157
245
353
459
561
694
817
976
[mm]
31,2
62,3
109
277
541
935
[mm]
27,0
54,1
93,8
244
474
809
412
1 / 2009
Material quality
Part
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Strength class 8.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Stainless steel grade A4, A5 > 8% ductile
strength class 70 for M24 and class 50 for M27 to M30, EN ISO 3506-1,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439;
1.4362
High corrosion resistant steel, EN 10088: 1.4529; 1.4565
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
hot dipped galvanized 45 m, EN ISO 10684
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
Threaded rod
HIT-V(F), HAS 5.8
Threaded rod
HIT-V(F), HAS 8.8
Threaded rod
HIT-V-R, HAS-R
Threaded rod
HIT-V-HCR, HAS-HCR
Washer
ISO 7089
Nut
EN ISO 4032
Anchor dimensions
Anchor rod
HIT-V, HIT-V-R, HIT-V-HCR
M39
M39x360
M36
M36x330
M33
M33x300
M30
M30x270
M27
M27x240
M24
M24x210
M20
M20x170
[mm]
M16
M16x125
M12
M12x110
Anchor rod
HAS, HAS-E,
HAS-R, HAS-ER
HAS-HCR
M10
M10x90
M8
M8x80
Anchor size
80
90
110
125
170
210
240
270
300
330
360
Setting
installation equipment
Anchor size
M8
M10
M12
M16
M20
M24
M27
M30
Rotary hammer
TE2 TE16
TE40 TE70
Other tools
compressed air gun or blow out pump, set of cleaning brushes, dispenser
Additional
DD EC-1, DD 100 DD xxx a)
Hilti recommended tools
a) For anchors in diamond drilled holes load values for combined pull-out and concrete cone resistance have to be
reduced (see section Simplified design method)
1 / 2009
413
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
414
1 / 2009
1 / 2009
415
Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only
For anchors in diamond drilled holes load values for combined pull-out and
concrete cone resistance have to be reduced. Load reduction factor: 0.7
416
1 / 2009
For dry concrete curing times may be reduced according to the following table.
For installation temperatures below +5 C all load values have to be reduced according to
the load reduction factors given below.
Curing time for dry concrete
Additional Hilti technical data
Temperature
of the
base material
40 C
30 C
20 C
15 C
10 C
5 C
0 C
-5 C
1 / 2009
417
Setting details
Data according ETA-04/0027, issue 2008-11-03
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
range a)
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
M8
M10
M12
M16
M20
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
d0
[mm]
10
12
14
18
24
28
30
35
37
40
42
hef,min
[mm]
40
40
48
64
80
96
108
120
132
144
156
hef,max
[mm]
160
200
240
320
400
480
540
600
660
720
780
hmin
[mm]
df
[mm]
12
14
18
22
26
30
33
36
39
42
smin
[mm]
40
50
60
80
100
120
135
150
165
180
195
cmin
[mm]
40
50
60
80
100
120
135
150
165
180
195
270
300
330
360
390
hef + 30 mm
100 mm
hef + 2 d0
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1.5 hef
Tmax
[Nm]
10
20
40
80
150
200
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
418
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
1 / 2009
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
11,1
12,0
17,7
19,3
12,4
13,9
17,7
19,3
M10
17,6
19,3
28,2
30,7
19,8
21,9
28,2
30,7
M12
25,4
28,0
40,6
44,7
28,6
31,6
40,6
44,7
M16
48,1
52,7
76,9
84,0
54,1
58,8
76,9
84,0
M20
74,8
82,0
119,6
130,7
84,1
92,0
119,6
130,7
M24
106,8
118,0
170,9
188,0
120,2
132,1
106,8
117,6
M27
144,6
153,3
231,3
244,7
75,9
80,4
144,6
152,9
M30
175,6
187,3
281,0
299,3
92,2
98,3
175,6
187,1
Additional Hilti
technical data
M33 M36 M39
215,7 253,0 304,3
231,3 272,3 325,3
345,1 404,8 486,9
370,1 435,7 520,5
113,2 132,8 159,8
122,6 144,3 172,4
134,8 158,1 190,2
144,6 170,2 203,3
419
Additional Hilti
technical data
M33 M36 M39
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80
90
110 125 170 200 210 270 300 330
hef,typ [mm]
0
N Rd,p Temperature range I
[kN] 15,3 21,5 31,6 44,9 76,3 105,6 135,7 157,5 171,0 203,3
0
N Rd,p Temperature range II [kN] 12,4 17,5 25,7 35,9 61,0 82,9 106,6 133,3 136,8 162,6
N0Rd,p Temperature range III [kN]
7,7 10,8 15,8 22,4 35,6 52,8 63,0 78,8 82,1 97,6
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2008-11-03):
The design values for combined pull-out and concrete cone resistance may be increased by 20 % for
installation in dry concrete (concrete not in contact with water before/during installation and curing).
360
232,9
186,3
111,8
anchor
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Additional Hilti
technical data
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
N0Rd,c
[kN] 17,2 20,5 27,7 33,6 53,3 73,2 89,4 106,7 125,0 144,2 164,3
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2008-11-03):
The design values for concrete cone resistance may be increased by 20 % for anchor installation in dry
concrete (concrete not in contact with water before/during installation and curing).
Data according ETA-04/0027, issue 2008-11-03
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0.1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
420
C 45/55
C 50/60
1,48
1,55
1 / 2009
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
0,1
s/scr,sp
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0,.5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
40
a)
50
60
a)
a)
70
80
a)
a)
90
100
a)
0,7
fre,N = 0,5 + hef/200mm 1
0,75
0,8
0,85
0,9
0,95
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
1 / 2009
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
421
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
6,6
7,2
10,6
12,0
7,5
8,3
10,6
12,0
M10
10,6
12,0
16,9
18,4
11,9
12,8
16,9
18,4
M12
15,2
16,8
24,4
27,2
17,1
19,2
24,4
27,2
M16
28,8
31,2
46,1
50,4
32,4
35,3
46,1
50,4
Additional Hilti
technical data
M33 M36 M39
129,4 151,8 182,6
138,8 163,4 195,2
207,0 242,9 292,2
222,1 261,4 312,3
67,9 79,7 95,9
72,9 85,8 102,5
80,9 94,9 114,1
86,8 102,1 122,0
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
[kN]
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
5,9
8,6
11,6
18,7
27,0
36,6
44,5
53,0
62,1
71,7
81,9
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
422
{h/(1,5 c)}
1/2
1 / 2009
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
1 / 2009
423
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
M27
162
222
M30
180
250
Additional Hilti
technical data
M33 M36 M39
198 216 234
272 296 324
49,6
58,1
67,0
76,3
86,1
92,0
138,8
48,3
92,0
112,0
162,6
58,8
112,0
138,8
187,6
72,9
86,8
163,4
213,8
85,8
102,1
195,2
241,0
102,5
122,0
Additional Hilti
technical data
M33 M36 M39
198 216 234
272 296 324
165 180 195
38,1
43,4
49,2
36,5
42,2
48,3
Additional Hilti
technical data
M33 M36 M39
198 216 234
272 296 324
165 180 195
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth
hef,1 = [mm]
48
60
72
96
120 144 162 180
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250
Spacing
s = smin= [mm]
40
50
60
80
100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN]
5,1
7,1
9,4 14,5 20,2 26,5 31,7 37,1 42,8 48,8
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
7,2 12,0 16,8 31,2 48,8 70,4 88,7 103,9 119,9 136,6
HIT-V 8.8
[kN]
7,2 18,4 26,3 40,5 56,5 74,3 88,7 103,9 119,9 136,6
HIT-V-R
[kN]
7,2 12,8 19,2 35,3 55,1 74,3 48,3 58,8 72,9 85,8
HIT-V-HCR
[kN]
7,2 18,4 26,3 40,5 56,5 70,9 88,7 103,9 86,8 102,1
424
55,0
154,0
154,0
102,5
122,0
1 / 2009
M27
240
300
M30
270
340
Additional Hilti
technical data
M33 M36 M39
300 330 360
374 410 450
112,0
179,2
58,8
112,0
138,8
222,1
72,9
86,8
163,4
261,4
85,8
102,1
195,2
312,3
102,5
122,0
Additional Hilti
technical data
M33 M36 M39
300 330 360
374 410 450
165 180 195
60,0
69,1
78,6
41,1
47,8
54,9
Additional Hilti
technical data
M33 M36 M39
300 330 360
374 410 450
165 180 195
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth
hef,typ = [mm]
80
90
110 125 170 210 240 270
Base material thickness hmin= [mm] 110 120 140 161 218 266 300 340
Spacing
s = smin= [mm]
40
50
60
80
100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN]
9,3 12,2 16,4 20,4 31,9 43,6 53,1 63,2 73,9 85,2
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4
HIT-V 8.8
[kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 177,0 207,0 238,5
HIT-V-R
[kN]
8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8
HIT-V-HCR
[kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1
1 / 2009
97,0
195,2
271,5
102,5
122,0
425
M30
360
430
Additional Hilti
technical data
M33 M36 M39
396 432 468
470 512 558
140,2
140,2
80,4
140,2
164,3
164,3
98,3
164,3
189,5
189,5
122,6
144,6
215,9
215,9
144,3
170,2
243,5
243,5
172,4
203,3
92,0
147,2
48,3
92,0
112,0
179,2
58,8
112,0
138,8
222,1
72,9
86,8
163,4
261,4
85,8
102,1
195,2
312,3
102,5
122,0
Additional Hilti
technical data
M33 M36 M39
396 432 468
470 512 558
165 180 195
84,8
96,6 108,9
45,0
52,3
60,0
Additional Hilti
technical data
M33 M36 M39
396 432 468
470 512 558
165 180 195
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth
hef,2 = [mm]
96
120 144 192 240 288 324 360
Base material thickness hmin= [mm] 126 150 174 228 288 344 384 430
Spacing
s = smin= [mm]
40
50
60
80
100 120 135 150
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN] 11,5 17,3 23,7 36,4 50,9 66,9 79,9 93,5 107,9 123,0
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
7,2 12,0 16,8 31,2 48,8 70,4 92,0 112,0 138,8 163,4
HIT-V 8.8
[kN] 12,0 18,4 27,2 50,4 78,4 112,8 147,2 179,2 222,1 261,4
HIT-V-R
[kN]
8,3 12,8 19,2 35,3 55,1 79,5 48,3 58,8 72,9 85,8
HIT-V-HCR
[kN] 12,0 18,4 27,2 50,4 78,4 70,9 92,0 112,0 86,8 102,1
426
138,6
195,2
312,3
102,5
122,0
1 / 2009
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
M27
162
222
M30
180
250
Additional Hilti
technical data
M33 M36 M39
198 216 234
272 296 324
35,4
41,5
47,9
54,5
61,5
116,7
152,7
61,3
72,9
139,4
172,2
73,2
87,1
Additional Hilti
technical data
M33 M36 M39
198 216 234
272 296 324
165 180 195
27,2
31,0
35,1
26,1
30,2
34,5
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
427
Additional Hilti
technical data
M33 M36 M39
198 216 234
272 296 324
165 180 195
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth
hef,1 = [mm]
48
60
72
96
120 144 162 180
Base material thickness hmin= [mm] 100 100 102 132 168 200 222 250
Spacing
s = smin= [mm]
40
50
60
80
100 120 135 150
Tensile Nrec: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN]
3,6
5,1
6,7 10,3 14,4 19,0 22,6 26,5 30,6 34,8 39,3
HIT-V-R
HIT-V-HCR
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
5,1
8,6 12,0 22,3 34,9 50,3 63,4 74,2 85,6 97,5 110,0
HIT-V 8.8
[kN]
5,1 13,1 18,8 28,9 40,4 53,1 63,4 74,2 85,6 97,5 110,0
HIT-V-R
[kN]
5,1
9,2 13,7 25,2 39,4 53,1 34,5 42,0 52,1 61,3 73,2
HIT-V-HCR
[kN]
5,1 13,1 18,8 28,9 40,4 50,6 63,4 74,2 62,0 72,9 87,1
Additional Hilti
technical data
M33 M36 M39
300 330 360
374 410 450
89,3
89,3
87,6
89,3
103,0
103,0
103,0
103,0
117,3
117,3
117,3
117,3
99,1
158,6
52,1
62,0
116,7
186,7
61,3
72,9
139,4
223,1
73,2
87,1
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
428
1 / 2009
Additional Hilti
technical data
M33 M36 M39
300 330 360
374 410 450
165 180 195
42,9
49,4
56,1
29,3
34,1
39,2
Additional Hilti
technical data
M33 M36 M39
300 330 360
374 410 450
165 180 195
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30
Embedment depth
hef,typ = [mm]
80
90
110 125 170 210 240 270
Base material thickness hmin= [mm] 110 120 140 161 218 266 300 340
Spacing
s = smin= [mm]
40
50
60
80
100 120 135 150
Tensile Nrec: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN]
6,6
8,7 11,7 14,6 22,8 31,1 37,9 45,2 52,8 60,8
HIT-V-R
HIT-V-HCR
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
5,1
8,6 12,0 22,3 34,9 50,3 65,7 80,0 99,1 116,7
HIT-V 8.8
[kN]
8,6 13,1 19,4 36,0 56,0 80,6 105,1 126,4 147,9 170,4
HIT-V-R
[kN]
6,0
9,2 13,7 25,2 39,4 56,8 34,5 42,0 52,1 61,3
HIT-V-HCR
[kN]
8,6 13,1 19,4 36,0 56,0 50,6 65,7 80,0 62,0 72,9
69,3
139,4
193,9
73,2
87,1
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
429
M30
360
430
Additional Hilti
technical data
M33 M36 M39
396 432 468
470 512 558
100,2
100,2
57,4
100,2
117,3
117,3
70,2
117,3
135,4
135,4
87,6
103,3
154,2
154,2
103,1
121,6
173,9
173,9
123,2
145,2
65,7
105,1
34,5
65,7
80,0
128,0
42,0
80,0
99,1
158,6
52,1
62,0
116,7
186,7
61,3
72,9
139,4
223,1
73,2
87,1
Additional Hilti
technical data
M33 M36 M39
396 432 468
470 512 558
165 180 195
60,5
69,0
77,8
32,1
37,3
42,9
Additional Hilti
technical data
M33 M36 M39
396 432 468
470 512 558
165 180 195
66,8
77,1
[kN]
8,2
12,4
16,9
26,0
36,4
47,8
57,0
87,8
99,0
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
5,1
8,6 12,0 22,3 34,9 50,3 65,7 80,0 99,1 116,7
HIT-V 8.8
[kN]
8,6 13,1 19,4 36,0 56,0 80,6 105,1 128,0 158,6 186,7
HIT-V-R
[kN]
6,0
9,2 13,7 25,2 39,4 56,8 34,5 42,0 52,1 61,3
HIT-V-HCR
[kN]
8,6 13,1 19,4 36,0 56,0 50,6 65,7 80,0 62,0 72,9
139,4
223,1
73,2
87,1
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
430
1 / 2009
1 / 2009
431
Benefits
Hilti
HIT-RE 500
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
HIS-(R)N sleeve
Concrete
Small edge
distance
and spacing
Fire
resistance
Fatigue
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
IBMB, Brunswick
warringtonfire
432
1 / 2009
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
Embedment depth [mm]
90
110
125
170
Base material thickness [mm]
120
150
170
230
M20
205
270
Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N
Anchor size
M8
M20
Tensile NRu,m
HIS-N
[kN]
26,3
48,3
70,4
123,9
114,5
Shear VRu,m
HIS-N
[kN]
13,7
24,2
41,0
62,0
57,8
M8
M20
Tensile NRk
HIS-N
[kN]
25,0
46,0
67,0
111,9
109,0
Shear VRk
HIS-N
[kN]
13,0
23,0
39,0
59,0
55,0
M8
M20
Tensile NRd
HIS-N
[kN]
16,8
27,7
33,6
53,3
70,6
Shear VRd
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
M8
M20
Tensile Nrec
HIS-N
[kN]
12,0
19,8
24,0
38,1
50,4
Shear Vrec
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
-40 C to +40 C
-40 C to +58 C
-40 C to +70 C
433
Materials
Mechanical properties of HIS-(R)N
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
Moment of
resistance W
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
490
800
700
700
410
640
350
450
M20
460
800
700
700
375
640
350
450
HIS-(R)N
[mm]
51,5
108,0
169,1
256,1
237,6
Screw
[mm]
36,6
58
84,3
157
245
HIS-(R)N
Screw
[mm]
[mm]
145
31,2
430
62,3
840
109
1595
277
1543
541
Material quality
Part
Material
C-steel 1.0718, EN 10277-3
internally threaded sleeves a)
HIS-N
steel galvanized 5m EN ISO 4042
internally threaded sleeves b)
stainless steel 1.4401 and 1.4571 EN 10088
HIS-RN
a) related fastening screw: strength class 8.8 EN ISO 898-1, A5 > 8% Ductile
steel galvanized 5m EN ISO 4042
b) related fastening screw: strength class 70 EN ISO 3506-1, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 EN 10088
Anchor dimensions
Anchor size
Internal sleeve
HIS-(R)N
Anchor embedment depth
[mm]
M8
M10
M12
M16
M20
M8x90
M10x110
M12x125
M16x170
M20x205
90
110
125
170
205
Setting
installation equipment
Anchor size
M8
M10
M12
M16
M20
Rotary hammer
TE 2 TE 16
TE 40 TE 70
Other tools
compressed air gun or blow out pump, set of cleaning brushes, dispenser
Additional
DD EC-1, DD 100 DD xxx a)
Hilti recommended tools
a) For anchors in diamond drilled holes load values for combined pull-out and concrete cone resistance have to be
reduced (see section Simplified design method)
434
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
1 / 2009
435
436
1 / 2009
Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only
For anchors in diamond drilled holes load values for combined pull-out and
concrete cone resistance have to be reduced. Load reduction factor: 0.7
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
437
For dry concrete curing times may be reduced according to the following table.
For installation temperatures below +5 C all load values have to be reduced according to
the load reduction factors given below.
Curing time for dry concrete
Additional Hilti technical data
Temperature
of the
base material
40 C
30 C
20 C
15 C
10 C
5 C
0 C
-5 C
438
1 / 2009
Setting details
Anchor size
Nominal diameter of
drill bit
Diameter of element
Effective anchorage
and drill hole depth
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Thread engagement
length; min - max
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
M8
M20
d0
[mm]
14
18
22
28
32
[mm]
12,5
16,5
20,5
25,4
27,6
hef
[mm]
90
110
125
170
205
hmin
[mm]
120
150
170
230
270
df
[mm]
12
14
18
22
hs
[mm]
8-20
10-25
12-30
16-40
20-50
smin
[mm]
40
45
55
65
90
cmin
[mm]
40
45
55
65
90
80
150
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1.5 hef
Tmax
[Nm]
10
20
40
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a) h: base material thickness (h hmin)
b) The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c) This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
439
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
[kN]
M8
16,8
13,9
M20
74,1
69,2
440
M20
205
95,2
81,0
45,2
for anchor
1 / 2009
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Data according ETA-04/0027, issue 2008-11-03
M10
M12
M16
Anchor size
M8
M20
N0Rd,c
[kN]
20,5
27,7
33,6
53,3
70,6
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2008-11-03):
The design values for concrete cone resistance may be increased by 20 % for anchor installation in dry
concrete (concrete not in contact with water before/during installation and curing).
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
0.1 a)
fB,p = (fck,cube/25N/mm)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N)
441
Influence of reinforcement
hef [mm]
80
90
100
0,9 a)
fre,N = 0,5 + hef/200mm 1
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
[kN]
[kN]
M8
10,4
8,3
M20
36,7
41,5
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
[kN]
= V0Rd,c fB f f h f4 f hef fc
M8
M10
M12
M16
M20
12,4
19,6
28,2
40,2
46,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
442
C 45/55
C 50/60
1,48
1,55
1 / 2009
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
M8
M10
M12
M16
M20
f hef =
1,38
1,21
1,04
1,22
1,45
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
443
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-04/0027, issue 2008-11-03
Anchor size
M8
M10
M12
M16
Embedment depth
hef = [mm]
90
110
125
170
Base material thickness hmin= [mm]
120
150
170
230
Tensile NRd: single anchor, no edge effects
M20
205
270
HIS-N
[kN]
16,8
27,7
33,6
53,3
70,6
HIS-RN
[kN]
13,9
21,9
31,6
53,3
69,2
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
[kN]
9,4
12,4
15,4
23,5
M20
205
270
90
32,0
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIS-(R)N
[kN]
4,2
5,5
7,6
10,8
17,2
[kN]
11,2
15,8
19,3
30,0
M20
205
270
90
40,5
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
444
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
1 / 2009
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
Data according ETA-04/0027, issue 2008-11-03
Anchor size
M8
M10
M12
M16
Embedment depth
hef = [mm]
90
110
125
170
Base material thickness hmin= [mm]
120
150
170
230
Tensile Nrec: single anchor, no edge effects
M20
205
270
HIS-N
[kN]
12,0
19,8
24,0
38,1
50,4
HIS-RN
[kN]
9,9
15,7
22,5
38,1
49,4
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
6,0
9,2
13,7
25,2
29,6
[kN]
6,7
8,9
11,0
16,8
M20
205
270
90
22,9
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
HIS-(R)N
[kN]
3,0
3,9
5,5
7,7
12,3
[kN]
8,0
11,3
13,8
21,5
M20
205
270
90
28,9
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
6,0
9,2
13,7
25,2
29,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
445
Benefits
Hilti
HIT-RE 500
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Fatigue
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
446
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Data according ETA-04/0027, issue 2008-11-03
Anchor size
8 10 12 14 16 20
Typical embedment depth [mm]
80
90
110 125 125 170
Base material thickness [mm]
110 120 145 165 165 220
a) The allowed range of embedment depth is shown in the setting details. The
calculated according to the simplified design method.
25 28 32
210 270 300
275 340 380
corresponding load
Additional
Hilti tech.
data
36 40
330 360
420 470
values can be
Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Data according ETA-04/0027, issue 2008-11-03
Anchor size
20
25
28
32
Additional
Hilti tech.
data
36 40
10
12
14
16
Tensile NRu,m
BSt 500 S
[kN]
29,4
45,2
65,1
89,3
Shear VRu,m
BSt 500 S
[kN]
14,7
23,1
32,6
44,1
57,8
Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-04/0027, issue 2008-11-03
Anchor size
10
12
14
16
20
25
28
32
Additional
Hilti tech.
data
36 40
Tensile NRk
BSt 500 S
[kN]
28,0
42,4
58,3
70,6
Shear VRk
BSt 500 S
[kN]
14,0
22,0
31,0
42,0
55,0
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-04/0027, issue 2008-11-03
Anchor size
28
10
12
14
16
20
25
Tensile NRd
BSt 500 S
[kN]
14,4
20,2
27,7
33,6
33,6
53,3
Shear VRd
BSt 500 S
[kN]
9,3
20,7
28,0
36,7
57,3
32
Additional
Hilti tech.
data
36 40
9,3
186,6 230,4
Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Data according ETA-04/0027, issue 2008-11-03
Anchor size
Additional
Hilti tech.
data
36 40
10
12
14
16
20
25
28
32
Tensile Nrec
BSt 500 S
[kN]
10,3
14,4
19,8
24,0
24,0
38,1
52,3
76,2
Shear Vrec
BSt 500 S
[kN]
6,7
14,8
20,0
26,2
41,0
64,3
80,5 105,2
6,7
133,3 164,6
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
447
Base material
temperature
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +58 C
-40 C to +70 C
Materials
Mechanical properties of rebar BSt 500S
10
12
14
16
20
25
28
32
Additional
Hilti tech.
data
36 40
[N/mm]
550
550
550
550
550
550
550
550
550
550
550
[N/mm]
500
500
500
500
500
500
500
500
500
500
500
[mm]
50,3
78,5 113,1 153,9 201,1 314,2 490,9 615,8 804,2 1018 1257
[mm]
50,3
98,2 169,6 269,4 402,1 785,4 1534 2155 3217 4580 6283
Material quality
Part
rebar
BSt 500 S
Material
Geometry and mechanical properties according to DIN 488-2:1986 or
E DIN 488-2:2006
Setting
installation equipment
Anchor size
8
10
12
14
16
20
25
28
32
36
Rotary hammer
TE 2 TE 16
TE 40 TE 70
Other tools
compressed air gun or blow out pump, set of cleaning brushes, dispenser
Additional
DD EC-1, DD 100 DD xxx a)
Hilti recommended tools
a) For anchors in diamond drilled holes load values for combined pull-out and concrete cone resistance have to be
reduced (see section Simplified design method)
448
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
a
)
a) Note: Manual cleaning only for hef 250 mm and anchor size d 16mm
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
449
450
1 / 2009
Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only
For anchors in diamond drilled holes load values for combined pull-out and
concrete cone resistance have to be reduced. Load reduction factor: 0.7
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
451
4h
8h
12 h
24 h
48 h
72 h
For dry concrete curing times may be reduced according to the following table.
For installation temperatures below +5 C all load values have to be reduced according to
the load reduction factors given below.
Curing time for dry concrete
Additional Hilti technical data
Temperature
of the
base material
40 C
30 C
20 C
15 C
10 C
5 C
0 C
-5 C
452
1 / 2009
Setting details
Data according ETA-04/0027, issue 2008-11-03
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
range a)
Minimum base
material thickness
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
10
12
14
16
20
25
28
32
Additional
Hilti tech.
data
36 40
d0
[mm]
12
14
16
18
20
25
32
35
40
45
55
hef,min
[mm]
60
60
70
75
80
90
100
112
128
144
160
hef,max
[mm]
160
200
240
280
320
400
500
560
640
720
800
smin
hef + 30 mm
100 mm
[mm] 40
50
60
70
80
100
125
140
160
180
200
cmin
[mm]
60
70
80
100
125
140
160
180
200
hmin
[mm]
40
50
hef + 2 d0
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1.5 hef
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
453
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups
with more than two anchors or more than one edge distance. The influencing factors
must then be considered for each edge distance and spacing. The calculated design
loads are then on the save side: They will be lower than the exact values according
ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design software
PROFIS anchor)
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
8
20,0
10
30,7
12
44,3
14
60,7
Additional
Hilti tech.
data
36 40
Anchor size
8 10 12 14 16 20 25 28 32
Typical embedment depth
80
90
110 125 125 170 210 270 300 330
hef,typ [mm]
0
N Rd,p Temperature range I
[kN] 14,4 20,2 29,6 36,7 41,9 71,2 102,1 147,0 186,7 192,8
N0Rd,p Temperature range II [kN] 11,5 16,2 23,7 31,4 32,9 56,0 86,4 113,1 143,6 154,2
N0Rd,p Temperature range III [kN]
6,7
9,4 13,8 18,3 20,9 33,1 51,1 67,9 86,2 92,5
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2008-11-03):
The design values for combined pull-out and concrete cone resistance may be increased by 20 % for
installation in dry concrete (concrete not in contact with water before/during installation and curing).
454
360
216,1
172,9
103,7
anchor
1 / 2009
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Additional
Hilti tech.
data
Anchor size
8 10 12 14 16 20 25 28 32 36 40
N0Rd,c
[kN] 17,2 20,5 27,7 33,6 33,6 53,3 73,2 106,7 125,0 144,2 164,3
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2008-11-03):
The design values for concrete cone resistance may be increased by 20 % for anchor installation in dry
concrete (concrete not in contact with water before/during installation and curing).
Data according ETA-04/0027, issue 2008-11-03
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
0,1 a)
fB,p = (fck,cube/25N/mm)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N)
1 / 2009
455
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
Anchor size
VRd,s
BSt 500 S
[kN]
Additional
Hilti
Data according ETA-04/0027, issue 2008-11-03
technical
data
8 10 12 14 16 20 25 28 32 36 40
9,3 20,7 28,0 36,7 57,3 90,0 112,7 147,3 9,3 186,6 230,4
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
456
[kN]
= V0Rd,c fB f f h f4 f hef fc
10
12
14
16
20
25
28
32
36
40
5,9
8,6
11,6
15,0
18,7
27,0
39,2
47,3
59,0
71,7
85,5
1 / 2009
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
1 / 2009
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
457
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)0,19
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
14
16
20
25
28
32
Additional
Hilti tech.
data
36 40
84
120
96
136
120
170
150
214
168
238
192
272
216
306
240
350
18,5
22,6
31,6
44,2
52,4
64,0
76,3
89,4
[kN]
10,8
11,2
14,7
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
20
25
28
32
Additional
Hilti tech.
data
36 40
120
170
100
150
214
125
168
238
140
192
272
160
216
306
180
240
350
200
18,3
25,6
30,3
37,0
44,1
52,5
34,6
42,2
50,4
[kN]
6,5
7,3
8,6
10,8
13,1
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
458
[kN]
3,5
4,9
6,7
8,6
10,8
15,7
22,9
27,7
1 / 2009
28
32
Additional
Hilti tech.
data
36 40
168
238
140
192
272
160
216
306
180
240
350
200
33,5
40,9
48,8
57,1
[kN]
6,7
7,1
9,4
11,8
14,5
20,2
28,2
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
56,5
79,0
[kN]
14,4
20,2
27,7
28
270
340
32
300
380
Additional
Hilti tech.
data
36 40
330 360
420 470
14
125
161
16
125
165
20
170
220
25
210
274
33,6
33,6
53,3
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
20
170
220
100
25
210
274
125
28
270
340
140
32
300
380
160
Additional
Hilti tech.
data
36 40
330 360
420 470
180 200
26,1
36,1
50,4
59,5
69,1
79,3
39,3
47,8
56,9
[kN]
7,8
10,0
13,3
16,2
17,0
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
1 / 2009
[kN]
3,7
5,3
7,3
9,5
11,5
17,2
25,0
31,6
459
28
270
340
140
32
300
380
160
Additional
Hilti tech.
data
36 40
330 360
420 470
180 200
62,6
73,6
85,2
[kN]
8,9
12,0
16,4
19,9
20,4
31,9
43,9
97,3
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
[kN]
17,2
26,9
38,8
25
300
364
28
336
406
32
384
464
Additional
Hilti tech.
data
36 40
432 480
522 590
14
168
204
16
192
232
20
240
290
49,3
64,0
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
20
240
290
100
25
300
364
125
28
336
406
140
32
384
464
160
Additional
Hilti tech.
data
36 40
432
480
522
590
180
200
40,0
55,9
66,2
80,9
96,6 113,1
42,6
52,3
[kN]
9,4
14,1
18,6
23,4
28,6
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
460
[kN]
3,9
5,7
7,8
10,2
12,9
18,9
27,8
33,9
62,7
1 / 2009
[kN]
10,9
16,6
23,3
29,7
36,4
50,9
71,2
28
336
406
140
32
384
464
160
Additional
Hilti tech.
data
36 40
432 480
522 590
180 200
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
1 / 2009
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
461
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm, Temperature range I
14
84
120
16
96
136
20
120
170
25
150
214
28
168
238
32
192
272
Additional
Hilti tech.
data
36 40
216 240
306 350
13,2
16,2
22,6
31,6
37,4
45,7
54,5
63,9
74,8
6,7
[kN]
7,7
8,0
10,5
[kN]
6,7
14,8
20,0
26,2
41,0
63,1
20
120
170
100
25
150
214
125
28
168
238
140
32
192
272
160
Additional
Hilti tech.
data
36 40
216 240
306 350
180 200
15,2
21,3
25,2
30,8
36,8
43,0
24,7
30,2
36,0
[kN]
4,6
5,4
7,1
8,9
10,9
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
2,5
3,5
4,8
6,2
7,7
11,2
16,3
19,8
28
168
238
140
32
192
272
160
Additional
Hilti tech.
data
36 40
216 240
306 350
180 200
23,9
29,2
34,8
[kN]
4,8
5,1
6,7
8,4
10,3
14,4
20,2
40,8
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
6,7
13,4
16,9
20,6
28,9
40,3
47,8
58,4
69,7
81,6
6,7
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
462
1 / 2009
[kN]
10,3
14,4
19,8
14
125
161
16
125
165
20
170
220
25
210
274
28
270
340
32
300
380
24,0
24,0
38,1
52,3
76,2
[kN]
6,7
14,8
20,0
26,2
41,0
64,3
6,7
20
170
220
100
25
210
274
125
28
270
340
140
32
300
380
160
Additional
Hilti tech.
data
36 40
330
360
420
470
180
200
21,7
29,9
41,2
48,8
56,8
65,2
28,1
34,1
40,6
[kN]
5,6
8,0
10,9
13,4
14,2
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
2,7
3,8
5,2
6,8
8,2
12,3
17,9
22,6
28
270
340
140
32
300
380
160
Additional
Hilti tech.
data
36 40
330
360
420
470
180
200
44,7
52,6
60,8
[kN]
6,4
8,6
11,7
14,2
14,6
22,8
31,3
69,5
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
6,7
14,8
20,0
26,2
41,0
62,6
6,7
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
463
[kN]
12,3
19,2
27,7
14
168
204
16
192
232
20
240
290
25
300
364
28
336
406
32
384
464
35,2
45,7
63,9
[kN]
6,7
14,8
20,0
26,2
41,0
64,3
6,7
20
240
290
100
25
300
364
125
28
336
406
140
32
384
464
160
Additional
Hilti tech.
data
36 40
432
480
522
590
180
200
32,0
44,7
52,9
64,7
77,2
90,4
30,5
37,3
44,8
[kN]
6,7
10,5
14,9
18,7
22,9
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
2,8
4,1
5,6
7,3
9,2
13,5
19,9
24,2
28
336
406
140
32
384
464
160
Additional
Additional
Hilti tech.
data
36 40
432
480
522
590
180
200
60,2
73,6
87,8 102,9
[kN]
7,8
11,9
16,7
21,2
26,0
36,4
50,8
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
6,7
14,8
20,0
26,2
41,0
64,3
6,7
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
464
1 / 2009
1 / 2009
465
Benefits
Hilti
HIT-HY 150
MAX
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
HAS rods
HAS-R rods
HAS-HCR rods
HAS-E rods
HAS-E-R rods
HIT-V rods
HIT-V-R rods
HIT-V-HCR rods
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Corrosion
resistance
High
corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
466
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
M20
M24
M27
Typical embedment depth hef [mm]
80
90
110
125
170
210
240
Base material thickness h [mm]
110
120
140
165
220
270
300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values
calculated according to the simplified design method.
M30
270
340
can be
M8
M10
M12
M16
M20
M24
M27
M30
Tensile NRu,m
HIT-V 5.8
[kN]
18,9
30,5
44,1
83,0
129,2
185,9
241,5
288,4
Shear VRu,m
HIT-V 5.8
[kN]
9,5
15,8
22,1
41,0
64,1
92,4
120,8
147,0
M8
M10
M12
M16
M20
M24
M27
M30
Tensile NRk
HIT-V 5.8
[kN]
18,0
29,0
42,0
70,6
111,9
153,7
187,8
216,3
Shear VRk
HIT-V 5.8
[kN]
9,0
15,0
21,0
39,0
61,0
88,0
115,0
140,0
M8
M10
M12
M16
M20
M24
M27
M30
Tensile NRd
HIT-V 5.8
[kN]
12,0
19,3
28,0
47,1
74,6
102,5
125,2
120,2
Shear VRd
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
92,0
112,0
M8
M10
M12
M16
M20
M24
M27
M30
Tensile Nrec
HIT-V 5.8
[kN]
8,6
13,8
20,0
33,6
53,3
73,2
89,4
85,8
Shear Vrec
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
467
Base material
temperature
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
Materials
Mechanical properties of HIT-V / HAS
Anchor size
HIT-V/HAS 5.8
Nominal
HIT-V/HAS 8.8
tensile
strength fuk HIT-V/HAS -R
HIT-V/HAS -HCR
HIT-V/HAS 5.8
HIT-V/HAS 8.8
Yield
strength fyk HIT-V/HAS -R
HIT-V/HAS -HCR
Stressed
HAS
crosssection As HIT-V
Moment of HAS
resistance
HIT-V
W
468
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
500
800
700
800
400
640
450
600
M10
500
800
700
800
400
640
450
600
M12
500
800
700
800
400
640
450
600
M16
500
800
700
800
400
640
450
600
M20
500
800
700
800
400
640
450
600
M24
500
800
700
700
400
640
450
400
M27
500
800
500
700
400
640
210
400
M30
500
800
500
700
400
640
210
400
[mm]
32,8
52,3
76,2
144
225
324
427
519
[mm]
36,6
58,0
84,3
157
245
353
459
561
[mm]
31,2
62,3
109
277
541
935
1387
1874
[mm]
27,0
54,1
93,8
244
474
809
1274
1706
1 / 2009
Material quality
Part
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Strength class 8.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Stainless steel grade A4, A5 > 8% ductile
strength class 70 for M24 and class 50 for M27 to M30, EN ISO 3506-1,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439;
1.4362
High corrosion resistant steel, EN 10088: 1.4529; 1.4565
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
hot dipped galvanized 45 m, EN ISO 10684
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
Threaded rod
HIT-V(F), HAS 5.8
Threaded rod
HIT-V(F), HAS 8.8
Threaded rod
HIT-V-R, HAS-R
Threaded rod
HIT-V-HCR, HAS-HCR
Washer
ISO 7089
Nut
EN ISO 4032
Anchor dimensions
M30
M30x270
M27
M27x240
M24
M24x210
[mm]
M20
M20x170
hef
M16
M16x125
Embedment depth
M12
M12x110
Anchor rod
HAS, HAS-R, HAS-HCR
HAS-E, HAS-E-R
M10
M10x90
M8
M8x80
Anchor size
80
90
110
125
170
210
240
270
Anchor rod
HIT-V, HIT-V-R, HIT-V-HCR
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
469
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
b)
a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!
For detailed information on installation see instruction for use given with the package of the product.
470
1 / 2009
-5 C
0 C
5 C
20 C
30 C
40 C
Curing time
tcure
12 h
4 h
2 h
1 h
30 min
30 min
Working time
tgel
180 min
40 min
20 min
8 min
5 min
2 min
Setting details
d0
Marking of the
embedment depth
df
Fixture
Thickness tfix
1 / 2009
471
Setting details
Anchor size
Nominal diameter of
drill bit
M8
M10
M12
M16
M20
M24
M27
M30
d0
[mm]
10
12
14
18
24
28
30
35
hef,min
[mm]
60
60
70
80
90
100
110
120
hef,max
[mm]
160
200
240
320
400
480
540
600
hef
[mm]
80
90
110
125
170
210
240
270
Minimum base
material thickness
hmin
[mm]
Diameter of clearance
df
hole in the fixture
hef + 30 mm
100 mm
hef + 2 d0
[mm]
12
14
18
22
26
30
33
Torque moment
Tmax b) [Nm]
10
20
40
80
150
200
270
300
Minimum spacing
smin
[mm]
40
50
60
80
100
120
135
150
cmin
[mm]
40
50
60
80
100
120
135
150
scr,sp
[mm]
Minimum edge
distance
Critical spacing
for splitting failure
ccr,sp
[mm]
2 ccr,sp
1,0 hef
2,26 hef
scr,N
[mm]
2 ccr,N
ccr,N
[mm]
1,5 hef
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a)
b)
Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
c)
d)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
472
1 / 2009
TENSION loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
1 / 2009
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
11,3
12,0
18,0
19,3
12,3
13,9
18,0
19,3
M10
17,3
19,3
28,0
30,7
19,8
21,9
28,0
30,7
M12
25,3
28,0
40,7
44,7
28,3
31,6
40,7
44,7
M16
48,0
52,7
76,7
84,0
54,0
58,8
76,7
84,0
M20
74,7
82,0
119,3
130,7
84,0
92,0
120,0
130,7
M24
106,7
118,0
170,7
188,0
119,8
132,1
106,7
117,6
M27
144,7
153,3
231,3
244,7
75,9
80,4
144,8
152,9
M30
175,3
187,3
281,3
299,3
92,0
98,3
175,7
187,1
473
[mm]
[kN]
[kN]
[kN]
M8
M10
M12
M16
M20
M24
M27
M30
80
90
110
125
170
210
240
270
15,6
13,4
8,9
22,0
18,8
12,6
32,3
27,6
18,4
54,5
50,3
29,3
85,5
78,3
46,3
116,1
105,6
63,3
135,7
122,1
74,6
120,2
99,0
63,6
M27
125,2
M30
124,5
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
[kN]
M8
20,1
M10
24,0
M12
32,4
M16
47,1
M20
74,6
M24
102,5
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1,00
1,02
1,04
1,06
1,07
fB,p = (fck,cube/25N/mm)0,10 a)
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,5 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
474
1 / 2009
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
SHEAR loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
6,8
7,2
10,8
12,0
7,7
8,3
10,4
12,0
M10
10,4
12,0
16,8
18,4
12,2
12,8
16,8
18,4
M12
15,2
16,8
24,8
27,2
17,3
19,2
24,8
27,2
M16
28,8
31,2
46,4
50,4
32,7
35,3
46,4
50,4
M20
44,8
48,8
72,0
78,4
50,6
55,1
72,0
78,4
M24
64,0
70,4
102,4
112,8
71,8
79,5
64,0
70,9
M27
87,2
92,0
139,2
147,2
45,8
48,3
86,9
92,0
M30
105,6
112,0
168,8
179,2
55,5
58,8
105,7
112,0
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
1 / 2009
[kN]
M8
M10
M12
M16
M20
M24
M27
M30
5,9
8,6
11,6
18,7
27,0
36,6
44,5
53,0
475
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
476
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1 / 2009
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)0,19
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
1 / 2009
477
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
28,7
33,7
38,8
36,9
48,8
57,5
55,1
57,5
67,3
67,3
67,3
67,3
77,7
77,7
48,3
77,7
88,5
88,5
58,8
88,5
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
29,4
28,9
21,8
25,9
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
150
Embedment depth
478
26,1
62,7
62,7
58,8
62,7
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
74,6
74,6
74,6
74,6
102,5
102,5
102,5
102,5
125,2
125,2
80,4
125,2
120,2
120,2
98,3
120,2
48,8
78,4
55,1
78,4
70,4
112,8
79,5
70,9
92,0
147,2
48,3
92,0
112,0
179,2
58,8
112,0
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
60,6
60,0
29,0
34,8
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
s [mm]
40
50
60
80
100
120
135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN]
9,9
13,4
19,1
28,5
44,6
61,0
74,3
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
92,0
HIT-V 8.8
[kN]
12,0
18,4
27,2
50,4
78,4
112,8
147,2
HIT-V-R
[kN]
8,3
12,8
19,2
35,3
55,1
79,5
48,3
HIT-V-HCR
[kN]
12,0
18,4
27,2
50,4
78,4
70,9
92,0
150
73,8
112,0
170,9
58,8
112,0
479
hef = 12 d a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
82,0
120,6
92,0
120,6
118,0
159,2
132,1
117,6
153,3
183,2
80,4
152,9
160,2
160,2
98,3
160,2
48,8
78,4
55,1
78,4
70,4
112,8
79,5
70,9
92,0
147,2
48,3
92,0
112,0
179,2
58,8
112,0
hef = 12 d a)
M8
M10
M12
M16
M20
M24
M27
M30
[mm]
96
120
144
192
240
288
324
360
h = hmin
[mm]
126
150
174
228
288
344
384
430
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
87,8
87,8
80,4
87,8
85,7
85,7
85,7
85,7
31,8
38,1
hef = 12 d a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
s=smin [mm]
40
50
60
80
100
120
135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
[kN]
12,0
18,5
26,0
50,8
71,3
93,7
111,8
HIT-V 8.8
[kN]
12,1
18,5
26,0
50,8
71,3
93,7
111,8
HIT-V-R
[kN]
12,1
18,5
26,0
50,8
71,3
93,7
80,4
HIT-V-HCR
[kN]
12,1
18,5
26,0
50,8
71,3
93,7
111,8
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
92,0
HIT-V 8.8
[kN]
12,0
18,4
27,2
50,4
78,4
112,8
147,2
HIT-V-R
[kN]
8,3
12,8
19,2
35,3
55,1
79,5
48,3
HIT-V-HCR
[kN]
12,0
18,4
27,2
50,4
78,4
70,9
92,0
a) d = element diameter
480
150
103,8
103,8
98,3
103,8
112,0
179,2
58,8
112,0
1 / 2009
1 / 2009
481
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
20,5
24,1
27,7
26,4
34,9
41,1
39,4
41,1
48,1
48,1
48,1
48,1
55,5
55,5
34,5
55,5
63,2
63,2
42,0
63,2
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
21,0
20,6
15,6
18,5
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
150
Embedment depth
18,6
44,8
44,8
42,0
44,8
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
482
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
53,3
53,3
53,3
53,3
73,2
73,2
73,2
73,2
89,4
89,4
57,4
89,4
85,9
85,9
70,2
85,9
34,9
56,0
39,4
56,0
50,3
80,6
56,8
50,6
65,7
105,1
34,5
65,7
80,0
128,0
42,0
80,0
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
43,3
42,9
20,7
24,9
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
[mm]
40
50
60
80
100
120
135
150
52,7
80,0
122,1
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
483
hef = 12 d a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
58,6
86,1
65,7
86,1
84,3
113,7
94,4
84,0
109,5
130,9
57,4
109,2
114,4
114,4
70,2
114,4
34,9
56,0
39,4
56,0
50,3
80,6
56,8
50,6
65,7
105,1
34,5
65,7
80,0
128,0
42,0
80,0
M8
M10
M12
M16
M20
M24
M27
M30
[mm]
96
120
144
192
240
288
324
360
h = hmin
[mm]
126
150
174
228
288
344
384
430
c = cmin
[mm]
40
50
60
80
100
120
135
150
62,7
62,7
57,4
62,7
61,2
61,2
61,2
61,2
22,7
27,2
hef = 12 d
a)
hef = 12 d a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
s=smin [mm]
40
50
60
80
100
120
135
Tensile Nrec: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
[kN]
8,6
13,2
18,6
36,3
50,9
66,9
79,9
HIT-V 8.8
[kN]
8,6
13,2
18,6
36,3
50,9
66,9
79,9
HIT-V-R
[kN]
8,6
13,2
18,6
36,3
50,9
66,9
57,4
HIT-V-HCR
[kN]
8,6
13,2
18,6
36,3
50,9
66,9
79,9
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
HIT-V 8.8
[kN]
8,6
13,1
19,4
36,0
56,0
80,6
105,1
HIT-V-R
[kN]
5,9
9,1
13,7
25,2
39,4
56,8
34,5
HIT-V-HCR
[kN]
8,6
13,1
19,4
36,0
56,0
50,6
65,7
a) d = element diameter
150
74,1
74,1
70,2
74,1
80,0
128,0
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
484
1 / 2009
1 / 2009
485
Benefits
Hilti
HIT-HY 150
MAX
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
Internal
threaded sleeve
HIS-N
HIS-RN
Concrete
Small edge
distance
and spacing
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
486
1 / 2009
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8x90
M10x110
M12x125
M16x170
Embedment depth
hef [mm]
90
110
125
170
Base material thickness h [mm]
120
150
170
230
M20x205
205
270
M8x90
M10x110
M12x125
M16x170
M20x205
Tensile NRu,m
HIS-N
[kN]
26,3
48,3
70,4
123,9
114,5
Shear VRu,m
HIS-N
[kN]
13,7
24,2
41,0
62,0
57,8
M8x90
M10x110
M12x125
M16x170
M20x205
Tensile NRk
HIS-N
[kN]
25,0
46,0
67,0
95,0
109,0
Shear VRk
HIS-N
[kN]
13,7
24,2
41,0
62,0
57,8
M8x90
M10x110
M12x125
M16x170
M20x205
Tensile NRd
HIS-N
[kN]
17,5
26,7
40,0
62,2
74,1
Shear VRd
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
M16x170
M20x205
M8x90
M10x110
M12x125
Tensile Nrec
HIS-N
[kN]
12,5
19,8
31,9
45,2
53,0
Shear Vrec
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
1 / 2009
487
Materials
Mechanical properties of HIS-(R)N
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
HIS-N
[N/mm]
M8x90
490
M10x110
490
M12x125
460
M16x170
460
M20x205
460
Screw 8.8
[N/mm]
800
800
800
800
800
HIS-RN
[N/mm]
700
700
700
700
700
Screw A4-70
[N/mm]
700
700
700
700
700
HIS-N
[N/mm]
410
410
375
375
375
Screw 8.8
[N/mm]
640
640
640
640
640
HIS-RN
[N/mm]
350
350
350
350
350
Screw A4-70
[N/mm]
450
450
450
450
450
HIS-(R)N
[mm]
51,5
108,0
169,1
256,1
237,6
Screw
[mm]
36,6
58
84,3
157
245
[mm]
145
430
840
1595
1543
[mm]
31,2
62,3
109
277
541
HIS-(R)N
Moment of
resistance W Screw
Material quality
Part
Material
a)
b)
related fastening screw: strength class 8.8 EN ISO 898-1, A5 > 8% Ductile
steel galvanized 5m EN ISO 4042
related fastening screw: strength class 70 EN ISO 3506-1, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 EN 10088
Anchor dimensions
Anchor size
Internal threaded sleeve
HIS-N / HIS-RN
Embedment depth
hef
[mm]
M8x90
M10x110
M12x125
M16x170
M20x205
80
90
110
125
170
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
488
M8x90
M10x110
M12x125
M16x170
M20x205
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
b)
1 / 2009
489
Curing time
tcure
12 h
4 h
2 h
1 h
30 min
30 min
Working time
tgel
180 min
40 min
20 min
8 min
5 min
2 min
-5 C
0 C
5 C
20 C
30 C
40 C
Setting details
df
d0
hS
490
1 / 2009
Anchor size
Nominal diameter of
drill bit
Diameter of element
M8x90
M10x110
M12x125
M16x170
M20x205
d0
[mm]
14
18
22
28
32
[mm]
12,5
16,5
20,5
25,4
27,6
hef
[mm]
90
110
125
170
205
hmin
[mm]
120
150
170
230
270
df
[mm]
12
14
18
22
Effective anchorage
and drill hole depth
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Thread engagement
length; min - max
Torque moment a)
hs
[mm]
8-20
10-25
12-30
16-40
20-50
Tmax
[Nm]
10
20
40
80
150
Minimum spacing
smin
[mm]
40
45
55
65
90
cmin
[mm]
40
45
55
65
90
scr,sp
[mm]
Minimum edge
distance
Critical spacing
for splitting failure
ccr,sp
[mm]
2 ccr,sp
1,0 hef
2,26 hef
scr,N
[mm]
2 ccr,N
ccr,N
[mm]
1,5 hef
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a)
Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
1 / 2009
491
TENSION loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
[kN]
M8x90
17,5
13,9
M10x110
30,7
21,9
M12x125
44,7
31,6
M16x170
80,3
58,8
M20x205
74,1
69,2
M16x170
170
63,3
63,3
40,0
M20x205
205
76,7
63,3
40,0
492
[mm]
[kN]
[kN]
[kN]
M8x90
90
19,4
16,7
11,1
M10x110
110
27,8
27,8
16,7
M12x125
125
50,0
40,0
26,7
1 / 2009
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
M8
24,0
[kN]
M10
32,4
M12
47,1
M16
74,6
M20
98,8
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1,00
1,02
1,04
1,06
1,07
fB,p = (fck,cube/25N/mm)0,10 a)
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,5 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
1 / 2009
493
Influence of reinforcement
hef [mm]
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
SHEAR loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
0
VRd,c = V
Rd,c
fB f f h f4 f hef fc
[kN]
[kN]
M8x90
10,4
8,3
M10x110
18,4
12,8
M12x125
26,0
19,2
M16x170
39,3
35,3
M20x205
36,7
41,5
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a)
[kN]
= V0Rd,c fB f f h f4 f hef fc
M8
M10
M12
M16
M20
12,4
19,6
28,2
40,2
46,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
494
C 45/55
C 50/60
1,48
1,55
1 / 2009
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
M8
M10
M12
M16
M20
f hef =
1,38
1,21
1,04
1,22
1,45
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
1 / 2009
20
30
40
0,57
0,52
0,50
495
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
[kN]
17,5
27,8
44,7
63,3
74,1
HIS-RN
[kN]
13,9
21,9
31,6
58,8
69,2
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Edge distance
c = cmin
[mm]
40
45
55
65
90
Embedment depth
[kN]
9,9
13,8
24,0
31,2
41,7
HIS-RN
[kN]
9,9
13,8
24,0
31,2
41,7
[kN]
4,2
5,5
7,6
10,8
17,2
HIS-RN
[kN]
4,2
5,5
7,6
10,8
17,2
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Spacing
s = smin
[mm]
40
45
55
65
90
[kN]
11,9
16,6
27,0
37,9
48,4
HIS-RN
[kN]
11,9
16,6
27,0
37,9
48,4
496
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
1 / 2009
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
[kN]
12,5
19,9
31,9
45,2
52,9
HIS-RN
[kN]
9,9
15,6
22,6
42,0
49,4
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
5,9
9,1
13,7
25,2
29,6
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Edge distance
c = cmin
[mm]
40
45
55
65
90
[kN]
7,1
9,9
17,1
22,3
29,8
HIS-RN
[kN]
7,1
9,9
17,1
22,3
29,8
[kN]
3,0
3,9
5,4
7,7
12,3
HIS-RN
[kN]
3,0
3,9
5,4
7,7
12,3
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Spacing
s = smin
[mm]
40
45
55
65
90
[kN]
8,5
11,9
19,3
27,1
34,6
HIS-RN
[kN]
8,5
11,9
19,3
27,1
34,6
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
5,9
9,1
13,7
25,2
29,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
497
Benefits
Hilti
HIT-HY 150
MAX
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
a)
European technical approval
Authority / Laboratory
DIBt, Berlin
498
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
8
10
12
14
16
20
25
b)
Embedment depth hef = hef,typ [mm]
80
90
110
125
170
210
240
Base material thickness h [mm]
110
120
140
165
220
270
300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
b) hef,typ: Typical embedment depth
10
12
14
16
20
25
Tensile NRu,m
BST 500 S
[kN]
25,5
35,8
52,5
69,6
92,3
135,3
204,9
Shear VRu,m
BST 500 S
[kN]
14,7
23,1
32,6
44,1
57,8
90,3
141,8
10
12
14
16
20
25
Tensile NRk
BST 500 S
[kN]
19,1
26,9
39,4
52,2
69,2
101,5
153,7
Shear VRk
BST 500 S
[kN]
14,0
22,0
31,0
42,0
55,0
86,0
135,0
10
12
14
16
20
25
Tensile NRd
BST 500 S
[kN]
10,6
14,9
21,9
29,0
46,2
67,6
85,4
Shear VRd
BST 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
10
12
14
16
20
25
Tensile Nrec
BST 500 S
[kN]
7,6
10,7
15,6
20,7
33,0
48,3
61,0
Shear Vrec
BST 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
64,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
499
Materials
Mechanical properties of rebar BSt 500S
Anchor size
Nominal
BSt 500 S
tensile
strength fuk
Yield
BSt 500 S
strength fyk
Stressed
BSt 500 S
crosssection As
Moment of
resistance BSt 500 S
W
10
12
14
[N/mm]
550
[N/mm]
500
16
20
25
[mm]
50,3
78,5
113,1
153,9
201,1
314,2
490,9
[mm]
50,3
98,2
169,6
269,4
402,1
785,4
1534
Material quality
Part
rebar
BSt 500 S
Material
Mechanical properties according to DIN 488-1:1984
Geometry according to DIN 488-21:1986
Anchor dimensions
Anchor size
rebar
BSt 500 S
10
12
14
16
20
25
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
500
10
12
14
16
20
25
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
b)
a) Note: Manual cleaning for element sizes d 14mm and embedment depth hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
501
-5 C
0 C
5 C
20 C
30 C
40 C
Working time
tgel
180 min
40 min
20 min
8 min
5 min
2 min
Curing time
tcure
12 h
4 h
2 h
1 h
30 min
30 min
d0
Setting details
502
1 / 2009
Anchor size
Nominal diameter of
drill bit
10
12
14
16
20
25
d0
[mm]
10
12
14
18
24
28
30
hef,min
[mm]
60
60
70
75
80
90
100
hef,max
[mm]
160
200
240
280
320
400
500
Minimum base
material thickness
hmin
[mm]
Minimum spacing
smin
[mm]
40
50
60
70
80
100
150
cmin
[mm]
40
50
60
80
100
120
150
scr,sp
[mm]
Minimum edge
distance
Critical spacing
for splitting failure
ccr,sp
[mm]
hef + 30 mm
100 mm
hef + 2 d0
2 ccr,sp
1,0 hef
2,26 hef
scr,N
[mm]
2 ccr,N
ccr,N
[mm]
1,5 hef
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a)
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
1 / 2009
503
TENSION loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
10
12
14
16
20
25
20,0
30,7
44,3
60,7
79,3
123,6
192,9
504
10
12
14
16
20
25
[mm]
80
90
110
125
145
170
210
[kN]
[kN]
[kN]
10,6
8,9
5,6
14,9
12,6
7,9
21,9
18,4
11,5
29,0
24,4
15,3
46,2
38,9
24,3
67,6
57,0
35,6
87,0
73,3
45,8
1 / 2009
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance a) NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
[kN]
10
12
14
16
20
25
20,1
24,0
32,4
39,2
58,8
74,6
85,4
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1,00
1,02
1,04
1,06
1,07
fB,p = (fck,cube/25N/mm)0,10 a)
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,5 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
1 / 2009
505
Influence of reinforcement
hef [mm]
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
SHEAR loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
[kN]
8
9,3
10
14,7
12
20,7
14
28,0
16
36,7
20
57,3
25
90,0
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
[kN]
10
12
14
16
20
25
5,9
8,6
11,6
15,0
18,7
27,0
39,2
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
C 45/55
C 50/60
1,48
1,55
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
506
1 / 2009
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
1 / 2009
507
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
13,9
18,6
28,7
33,7
32,4
36,7
57,3
77,7
[kN]
8,0
9,9
[kN]
9,3
14,7
20,7
28,0
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
13,9
22,4
27,5
27,5
[kN]
4,8
6,7
9,5
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
3,5
4,9
6,6
10,0
13,2
17,4
21,8
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
100
116
138
156
170
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
18,6
22,4
23,5
[kN]
5,4
6,8
9,3
12,2
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
508
[kN]
9,3
14,7
20,7
28,0
36,7
44,9
56,5
1 / 2009
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
21,9
29,0
46,2
67,6
85,4
36,7
57,3
90,0
[kN]
10,6
14,9
[kN]
9,3
14,7
20,7
28,0
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
18,6
31,1
44,6
50,5
21,5
27,5
[kN]
6,4
9,0
13,2
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
3,7
5,3
7,3
11,2
15,8
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
30,1
42,5
52,9
Embedment depth
[kN]
7,4
10,1
14,7
19,1
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
1 / 2009
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
509
hef = 12 d a)
h = hmin
10
12
14
16
20
25
[mm]
96
120
144
168
192
240
300
[mm]
126
150
176
204
232
290
364
28,7
39,0
61,1
95,5
124,4
36,7
57,3
90,0
[kN]
12,7
19,9
[kN]
9,3
14,7
20,7
28,0
hef = 12 d a)
10
12
14
16
20
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
25,1
41,2
63,0
74,9
23,6
30,5
[kN]
7,7
12,0
17,2
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
3,9
5,7
7,8
12,0
16,9
hef = 12 d a)
10
12
14
16
20
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
40,9
62,6
82,0
[kN]
8,9
13,8
19,6
26,4
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
a) d = element diameter
510
1 / 2009
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
9,9
13,3
20,5
24,1
23,1
26,2
40,9
55,5
[kN]
5,7
7,1
[kN]
6,6
10,5
14,8
20,0
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
9,9
16,0
19,6
19,6
12,4
15,6
[kN]
3,4
4,8
6,8
Shear Vrec: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
2,5
3,5
4,7
7,1
9,4
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
100
116
138
156
170
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
13,3
16,0
16,8
[kN]
3,9
4,9
6,6
8,7
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
6,6
10,5
14,8
20,0
26,2
32,1
40,4
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
511
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
15,6
20,7
33,0
48,3
61,0
26,2
40,9
64,3
[kN]
7,6
10,6
[kN]
6,6
10,5
14,8
20,0
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
13,3
22,2
31,9
36,1
15,4
19,6
[kN]
4,6
6,4
9,4
Shear Vrec: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
2,6
3,8
5,2
8,0
11,3
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
21,5
30,4
37,8
Embedment depth
[kN]
5,3
7,2
10,5
13,6
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
6,6
10,5
14,8
20,0
26,2
40,9
64,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
512
1 / 2009
10
12
14
16
20
25
hef = 12 d *
[mm]
96
120
144
168
192
240
300
h = hmin
[mm]
126
150
176
204
232
290
364
20,5
27,9
43,6
68,2
88,9
26,2
40,9
64,3
[kN]
9,1
14,2
[kN]
6,6
10,5
14,8
20,0
10
12
14
16
20
hef = 12 d *
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
17,9
29,4
45,0
53,5
16,9
21,8
[kN]
5,5
8,6
12,3
Shear Vrec: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
2,8
4,1
5,6
8,6
12,1
10
12
14
16
20
hef = 12 d *
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
29,2
44,7
58,6
[kN]
6,4
9,9
14,0
18,9
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
6,6
10,5
14,8
20,0
26,2
40,9
64,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
a) d = element diameter
1 / 2009
513
HIT-TZ
Injection adhesive anchor
Benefits
Hilti
HIT-HY 150
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
HIT-TZ
HIT-RTZ rod
Concrete
Tensile
zone
Fire
resistance
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
IBMB, Braunschweig
warringtonfire
514
1 / 2009
HIT-TZ
Injection adhesive anchor
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
Embedment depth [mm]
55
65
75
90
Base material thickness [mm]
110
130
150
180
M20
120
240
Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-TZ
Anchor size
Non cracked concrete
Tensile NRu,m HIT-TZ
M8
M20
[kN]
21,3
26,7
33,3
57,5
88,5
Shear VRu,m
HIT-TZ
Cracked concrete
Tensile NRu,m HIT-TZ
[kN]
11,6
17,9
26,3
49,4
77,7
[kN]
12,0
21,3
26,7
40,0
53,3
Shear VRu,m
[kN]
12,0
17,9
26,3
49,4
77,7
HIT-TZ
M8
M20
[kN]
16,0
20,0
25,0
43,1
66,4
Shear VRk
HIT-TZ
Cracked concrete
Tensile NRk
HIT-TZ
[kN]
11,0
17,0
25,0
47,0
74,0
[kN]
9,0
16,0
20,0
30,0
40,0
Shear VRk
[kN]
9,0
17,0
25,0
47,0
74,0
HIT-TZ
M8
M20
[kN]
10,7
13,3
16,7
28,7
44,3
Shear VRd
HIT-TZ
Cracked concrete
Tensile NRd
HIT-TZ
[kN]
8,8
13,6
20,0
37,6
59,2
[kN]
6,0
10,7
13,3
20,0
26,7
Shear VRd
[kN]
6,0
13,6
20,0
37,6
53,3
HIT-TZ
M8
M20
[kN]
7,6
9,5
11,9
20,5
31,6
Shear Vrec
HIT-TZ
Cracked concrete
Tensile Nrec
HIT-TZ
[kN]
6,3
9,7
14,3
26,9
42,3
[kN]
4,3
7,6
9,5
14,3
19,0
Shear Vrec
[kN]
4,3
9,7
14,3
26,9
38,1
HIT-TZ
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
515
HIT-TZ
Injection adhesive anchor
Base material
temperature
Temperature range I
-40 C to +80 C
Materials
Mechanical properties of HIT-(R)TZ
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
M8
M20
HIT-TZ
[N/mm]
600
600
600
600
600
HIT-RTZ
[N/mm]
600
600
600
600
600
HIT-TZ
HIT-RTZ
[N/mm]
[N/mm]
480
480
480
480
480
480
480
480
480
480
[mm]
36,6
58,0
84,3
157
245
[mm]
27,0
54,1
93,8
244
474
M16
M16x90
90
M20
M20x120
120
M16
M20
TE 40 - TE 70
Stressed
crossHIT-TZ
section As
Moment of
HIT-TZ
resistance W
Material quality
Part
Material
C-steel cold formed
steel galvanized 5m EN ISO 4042
stainless steel cold formed
1.4404 and 1.4401 EN 10088
HIT-TZ
HIT-RTZ
Anchor dimensions
Anchor size
HIT-(R)TZ
Anchor embedment depth
[mm]
M8
M8x55
55
M10
M10x65
65
M12
M12x75
75
Setting
installation equipment
Anchor size
Rotary hammer
516
M8
M10
M12
TE 2 TE 16
1 / 2009
HIT-TZ
Injection adhesive anchor
Setting instruction
Dry, water-saturated concrete, under water, hammer drilling and diamond coring
1. Diamond coring is permissible only when the Hilti DD EC-1 diamond core drilling machine and the
corresponding DD-C core bit are used.
2. Check the setting depth and compress the drilling dust. It is not necessary to clean the hole.
3. For use with Hilti HIT-HY 150 / Hilti HIT-HY 150 MAX. Read the instructions before use.
For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.
1 / 2009
517
HIT-TZ
Injection adhesive anchor
Setting details
Anchor size
Nominal diameter of
drill bit
M8
M20
d0
[mm]
10
12
14
18
22
Diameter of element
[mm]
10
12
16
20
Effective anchorage
depth
hef
[mm]
55
65
75
90
120
h0
[mm]
60
70
80
95
125
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Non cracked concrete
Minimum spacing
for
Minimum edge
distance
for
Cracked concrete
Minimum spacing
for
Minimum edge
distance
for
Critical spacing for
splitting failure
Critical edge distance
for splitting failure
Critical spacing for
concrete cone failure
Critical edge distance
for concrete cone
failure
Torque moment
hmin a)
[mm]
110
130
150
180
240
df
[mm]
12
14
18
22
smin
c
[mm]
[mm]
40
50
50
70
55
75
70
80
80
90
cmin
[mm]
40
50
55
70
80
[mm]
70
80
85
85
90
smin
c
[mm]
[mm]
40
65
60
85
70
100
80
100
100
120
cmin
[mm]
50
60
70
80
100
[mm]
80
120
130
140
150
scr,sp
[mm]
2 ccr,sp
ccr,sp
[mm]
2 hef
70
130
scr,N
2 ccr,N
ccr,N
1,5 hef
Tinst
[Nm]
12
23
40
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
518
1 / 2009
HIT-TZ
Injection adhesive anchor
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
M8
14,7
M20
98,0
Design combined pull-out and concrete cone resistance NRd,p = N0Rd,p fB,p fh,p
Anchor size
Embedment depth hef [mm]
Non cracked concrete
N0Rd,p Temperature range I
Cracked concrete
N0Rd,p Temperature range I
1 / 2009
M8
55
M20
120
[kN]
10,7
13,3
16,7
28,7
44,3
[kN]
6,0
10,7
13,3
20,0
26,7
519
HIT-TZ
Injection adhesive anchor
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f h,N f1,sp f2,sp f3,sp fre,N
Anchor size
N0Rd,c Non cracked concrete [kN]
N0Rd,c Cracked concrete
[kN]
M8
13,7
9,8
M20
44,3
31,5
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0.1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
f2,N =
0,5(1 + c/ccr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
520
1 / 2009
HIT-TZ
Injection adhesive anchor
Influence of reinforcement
hef [mm]
80
90
100
0,9 a)
fre,N = 0,5 + hef/200mm 1
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
0
VRd,c = V
Rd,c
fB f f h f4
M8
8,8
[kN]
M20
59,2
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
M8
M10
M12
M16
Cracked concrete
M20
M8
M10
M12
M16
M20
V Rd,c
[kN]
3,1
4,5
6,1
8,5
13,4
1,6
a) For anchor groups only the anchors close to the edge must be considered.
2,4
3,1
5,0
6,9
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
1 / 2009
C 45/55
C 50/60
1,48
1,55
521
HIT-TZ
Injection adhesive anchor
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
0 - 55
60
65
70
75
80
85
90 - 180
1,07
1,14
1,23
1,35
1,50
1,71
{h/(1,5 c)}
2/3
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,22
0,34
0,45
0,54
0,63
0,71
0,79
0,86
0,93
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
Group of two anchors s/hef
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75 10,50 11,25
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86 5,86 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31 6,55 6,55
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78 7,02 7,26
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25 7,50 7,75
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73 7,99 8,25
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22 8,49 8,75
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72 8,99 9,26
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22 9,50 9,78
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74 10,02 10,31
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26 10,55 10,85
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing smin and the
minimum edge distance cmin.
c/hef
522
1 / 2009
HIT-TZ
Injection adhesive anchor
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-04/0084, issue 2007-01-03
Anchor size
M8
M10
M12
M16
Embedment depth
hef = [mm]
55
65
75
90
Base material thickness hmin= [mm]
110
130
150
180
Tensile NRd: single anchor, no edge effects
Non cracked concrete
HIT-(R)TZ
Cracked concrete
HIT-(R)TZ
M20
120
240
[kN]
10,7
13,3
16,7
28,7
44,3
[kN]
6,0
10,7
13,3
20,0
26,7
37,6
59,2
37,6
53,3
M20
120
240
cmin
[mm]
50
60
70
80
100
HIT-(R)TZ
Cracked concrete
cmin
[kN]
6,5
8,2
10,3
17,3
25,9
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
3,3
6,0
7,4
11,3
14,2
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
1 / 2009
cmin
[mm]
50
60
70
80
100
HIT-(R)TZ
Cracked concrete
cmin
[kN]
3,1
4,5
6,1
8,5
13,4
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
1,6
2,4
3,1
5,0
6,9
523
HIT-TZ
Injection adhesive anchor
M20
120
240
100
HIT-(R)TZ
Cracked concrete
smin
[kN]
6,3
8,2
10,3
17,6
26,7
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
3,5
6,4
7,9
11,9
15,6
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
smin
[mm]
40
60
70
80
100
HIT-(R)TZ
Cracked concrete
smin
[kN]
6,6
13,6
20,0
37,3
56,5
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
3,7
13,4
16,6
25,2
32,6
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm
Data according ETA-04/0084, issue 2007-01-03
Anchor size
M8
M10
M12
M16
Embedment depth
hef = [mm]
55
65
75
90
Base material thickness hmin= [mm]
110
130
150
180
Tensile Nrec: single anchor, no edge effects
Non cracked concrete
HIT-(R)TZ
Cracked concrete
HIT-(R)TZ
M20
120
240
[kN]
7,6
9,5
11,9
20,5
31,6
[kN]
4,3
7,6
9,5
14,3
19,0
26,9
42,3
26,9
38,1
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
524
1 / 2009
HIT-TZ
Injection adhesive anchor
M20
120
240
100
HIT-(R)TZ
Cracked concrete
cmin
[kN]
4,6
5,8
7,3
12,4
18,5
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
2,4
4,3
5,3
8,1
10,2
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
Non cracked concrete
cmin
50
60
70
80
[mm]
100
HIT-(R)TZ
Cracked concrete
cmin
[kN]
2,2
3,2
4,4
6,1
9,6
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
1,1
1,7
2,2
3,5
4,9
M20
120
240
100
HIT-(R)TZ
Cracked concrete
smin
[kN]
4,5
5,9
7,3
12,5
19,1
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
2,5
4,5
5,6
8,5
11,1
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
Non cracked concrete
smin
[mm]
40
60
70
80
100
HIT-(R)TZ
Cracked concrete
smin
[kN]
4,7
9,7
14,3
26,6
40,4
[mm]
40
50
55
70
80
HIT-(R)TZ
[kN]
2,7
9,6
11,9
18,0
23,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
525
Benefits
Hilti
HIT-HY 150
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
HAS rods
HAS-R rods
HAS-HCR rods
HAS-E rods
HAS-E-R rods
HIT-V rods
HIT-V-R rods
HIT-V-HCR rods
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Fire
resistance
Fatigue
Corrosion
resistance
High
corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Fire test report
Assessment report (fire)
Authority / Laboratory
DIBt, Berlin
MFPA Braunschweig
warringtonfire
526
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
M20
M24
M27
Typical embedment depth hef [mm]
80
90
110
125
170
210
240
Base material thickness h [mm]
110
120
140
165
220
270
300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values
calculated according to the simplified design method.
M30
270
340
can be
M8
M10
M12
M16
M20
M24
M27
M30
Tensile NRu,m
HIT-V 5.8
[kN]
18,9
30,5
44,1
75,4
121,1
168,9
203,6
237,5
Shear VRu,m
HIT-V 5.8
[kN]
9,5
15,8
22,1
41,0
64,1
92,4
120,8
147,0
M8
M10
M12
M16
M20
M24
M27
M30
Tensile NRk
HIT-V 5.8
[kN]
18,0
29,0
42,0
56,5
90,8
126,7
152,7
178,1
Shear VRk
HIT-V 5.8
[kN]
9,0
15,0
21,0
39,0
61,0
88,0
115,0
140,0
M8
M10
M12
M16
M20
M24
M27
M30
Tensile NRd
HIT-V 5.8
[kN]
12,0
17,3
25,3
26,9
43,2
60,3
72,7
84,8
Shear VRd
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
92,0
112,0
M8
M10
M12
M16
M20
M24
M27
M30
Tensile Nrec
HIT-V 5.8
[kN]
8,6
12,3
18,1
19,2
30,9
43,1
51,9
60,6
Shear Vrec
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
80,0
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
527
Base material
temperature
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
Materials
Mechanical properties of HIT-V / HAS
Anchor size
HIT-V/HAS 5.8
Nominal
HIT-V/HAS 8.8
tensile
strength fuk HIT-V/HAS -R
HIT-V/HAS -HCR
HIT-V/HAS 5.8
HIT-V/HAS 8.8
Yield
strength fyk HIT-V/HAS -R
HIT-V/HAS -HCR
Stressed
HAS
crosssection As HIT-V
Moment of HAS
resistance
HIT-V
W
528
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
500
800
700
800
400
640
450
600
M10
500
800
700
800
400
640
450
600
M12
500
800
700
800
400
640
450
600
M16
500
800
700
800
400
640
450
600
M20
500
800
700
800
400
640
450
600
M24
500
800
700
700
400
640
450
400
M27
500
800
500
700
400
640
210
400
M30
500
800
500
700
400
640
210
400
[mm]
32,8
52,3
76,2
144
225
324
427
519
[mm]
36,6
58,0
84,3
157
245
353
459
561
[mm]
31,2
62,3
109
277
541
935
1387
1874
[mm]
27,0
54,1
93,8
244
474
809
1274
1706
1 / 2009
Material quality
Part
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Strength class 8.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Stainless steel grade A4, A5 > 8% ductile
strength class 70 for M24 and class 50 for M27 to M30, EN ISO 3506-1,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439;
1.4362
High corrosion resistant steel, EN 10088: 1.4529; 1.4565
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
hot dipped galvanized 45 m, EN ISO 10684
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
Threaded rod
HIT-V(F), HAS 5.8
Threaded rod
HIT-V(F), HAS 8.8
Threaded rod
HIT-V-R, HAS-R
Threaded rod
HIT-V-HCR, HAS-HCR
Washer
ISO 7089
Nut
EN ISO 4032
Anchor dimensions
M30
M30x270
M27
M27x240
M24
M24x210
[mm]
M20
M20x170
hef
M16
M16x125
Embedment depth
M12
M12x110
Anchor rod
HAS, HAS-R, HAS-HCR
HAS-E, HAS-E-R
M10
M10x90
M8
M8x80
Anchor size
80
90
110
125
170
210
240
270
Anchor rod
HIT-V, HIT-V-R, HIT-V-HCR
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
529
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
b)
a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!
For detailed information on installation see instruction for use given with the package of the product.
530
1 / 2009
Setting details
d0
Marking of the
embedment depth
df
Fixture
Thickness tfix
1 / 2009
531
Setting details
Anchor size
Nominal diameter of
drill bit
M8
M10
M12
M16
M20
M24
M27
M30
d0
[mm]
10
12
14
18
24
28
30
35
hef,min
[mm]
60
60
70
80
90
100
110
120
hef,max
[mm]
160
200
240
320
400
480
540
600
hef
[mm]
80
90
110
125
170
210
240
270
Minimum base
material thickness
hmin
[mm]
Diameter of clearance
df
hole in the fixture
hef + 30 mm
100 mm
hef + 2 d0
[mm]
12
14
18
22
26
30
33
Torque moment
Tmax b) [Nm]
10
20
40
80
150
200
270
300
Minimum spacing
smin
[mm]
40
50
60
80
100
120
135
150
cmin
[mm]
40
50
60
80
100
120
135
150
scr,sp
[mm]
Minimum edge
distance
Critical spacing
for splitting failure
ccr,sp
[mm]
2 ccr,sp
1,0 hef
2,26 hef
scr,N
[mm]
2 ccr,N
ccr,N
[mm]
1,5 hef
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a)
b)
Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
c)
d)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
532
1 / 2009
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
1 / 2009
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
11,3
12,0
18,0
19,3
12,3
13,9
18,0
19,3
M10
17,3
19,3
28,0
30,7
19,8
21,9
28,0
30,7
M12
25,3
28,0
40,7
44,7
28,3
31,6
40,7
44,7
M16
48,0
52,7
76,7
84,0
54,0
58,8
76,7
84,0
M20
74,7
82,0
119,3
130,7
84,0
92,0
120,0
130,7
M24
106,7
118,0
170,7
188,0
119,8
132,1
106,7
117,6
M27
144,7
153,3
231,3
244,7
75,9
80,4
144,8
152,9
M30
175,3
187,3
281,3
299,3
92,0
98,3
175,7
187,1
533
[mm]
[kN]
[kN]
[kN]
M8
M10
M12
M16
M20
M24
M27
M30
80
90
110
125
170
210
240
270
14,7
10,1
8,7
17,3
11,8
10,2
25,3
17,3
15,0
26,9
18,0
15,0
43,2
28,0
25,4
60,3
37,7
33,9
72,7
48,5
38,8
84,8
60,6
48,5
M27
89,4
M30
106,7
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
[kN]
M8
17,2
M10
20,5
M12
27,7
M16
33,6
M20
53,3
M24
73,2
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1,00
1,03
1,06
1,09
1,11
fB,p = (fck,cube/25N/mm)0,15 a)
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,13
1,14
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,5 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
534
1 / 2009
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
6,8
7,2
10,8
12,0
7,7
8,3
10,4
12,0
M10
10,4
12,0
16,8
18,4
12,2
12,8
16,8
18,4
M12
15,2
16,8
24,8
27,2
17,3
19,2
24,8
27,2
M16
28,8
31,2
46,4
50,4
32,7
35,3
46,4
50,4
M20
44,8
48,8
72,0
78,4
50,6
55,1
72,0
78,4
M24
64,0
70,4
102,4
112,8
71,8
79,5
64,0
70,9
M27
87,2
92,0
139,2
147,2
45,8
48,3
86,9
92,0
M30
105,6
112,0
168,8
179,2
55,5
58,8
105,7
112,0
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
1 / 2009
[kN]
M8
M10
M12
M16
M20
M24
M27
M30
5,9
8,6
11,6
18,7
27,0
36,6
44,5
53,0
535
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
536
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1 / 2009
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)0,19
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
1 / 2009
537
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
20,5
24,0
27,7
31,6
48,8
57,5
55,1
57,5
67,3
67,3
67,3
67,3
77,7
77,7
48,3
77,7
88,5
88,5
58,8
88,5
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
23,2
27,1
21,8
25,9
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
150
Embedment depth
538
22,4
62,7
62,7
58,8
62,7
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
43,2
43,2
43,2
43,2
60,3
60,3
60,3
60,3
72,7
72,7
72,7
72,7
84,8
84,8
84,8
84,8
48,8
78,4
55,1
78,4
70,4
112,8
79,5
70,9
92,0
147,2
48,3
92,0
112,0
179,2
58,8
112,0
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
46,3
55,0
29,0
34,8
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
s [mm]
40
50
60
80
100
120
135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
HIT-V 8.8
[kN]
9,9
11,3
16,3
17,5
28,2
39,4
47,9
HIT-V-R
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
92,0
HIT-V 8.8
[kN]
12,0
18,4
27,2
45,7
72,4
100,5
120,9
HIT-V-R
[kN]
8,3
12,8
19,2
35,3
55,1
79,5
48,3
HIT-V-HCR
[kN]
12,0
18,4
27,2
45,7
72,4
70,9
92,0
150
56,5
112,0
140,7
58,8
112,0
539
hef = 12 d a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
61,0
61,0
61,0
61,0
82,7
82,7
82,7
82,7
98,2
98,2
80,4
98,2
113,1
113,1
98,3
113,1
48,8
78,4
55,1
78,4
70,4
112,8
79,5
70,9
92,0
147,2
48,3
92,0
112,0
179,2
58,8
112,0
hef = 12 d a)
M8
M10
M12
M16
M20
M24
M27
M30
[mm]
96
120
144
192
240
288
324
360
h = hmin
[mm]
126
150
174
228
288
344
384
430
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
62,6
73,4
31,8
38,1
hef = 12 d a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
s=smin [mm]
40
50
60
80
100
120
135
Tensile NRd: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
[kN]
12,0
15,5
22,0
28,0
41,2
55,8
66,6
HIT-V 8.8
12,1
15,5
22,0
28,0
41,2
55,8
66,6
HIT-V-R
[kN]
HIT-V-HCR
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
92,0
HIT-V 8.8
[kN]
12,0
18,4
27,2
50,4
78,4
112,8
147,2
HIT-V-R
[kN]
8,3
12,8
19,2
35,3
55,1
79,5
48,3
HIT-V-HCR
[kN]
12,0
18,4
27,2
50,4
78,4
70,9
92,0
a) d = element diameter
540
150
77,3
77,3
112,0
179,2
58,8
112,0
1 / 2009
1 / 2009
541
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
14,6
17,1
19,8
22,6
34,9
41,1
39,4
41,1
48,1
48,1
48,1
48,1
55,5
55,5
34,5
55,5
63,2
63,2
42,0
63,2
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
16,6
19,4
15,6
18,5
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,min
[mm]
60
60
70
80
90
100
110
120
h = hmin
[mm]
100
100
100
116
138
156
170
190
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
150
Embedment depth
16,0
44,8
44,8
42,0
44,8
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
542
1 / 2009
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
30,9
30,9
30,9
30,9
43,1
43,1
43,1
43,1
51,9
51,9
51,9
51,9
60,6
60,6
60,6
60,6
34,9
56,0
39,4
56,0
50,3
80,6
56,8
50,6
65,7
105,1
34,5
65,7
80,0
128,0
42,0
80,0
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
150
33,1
39,3
20,7
24,9
M8
M10
M12
M16
M20
M24
M27
M30
hef = hef,typ
[mm]
80
90
110
125
170
210
240
270
h = hmin
[mm]
110
120
140
161
218
266
300
340
[mm]
40
50
60
80
100
120
135
150
40,4
80,0
100,5
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
543
hef = 12 d a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
43,6
43,6
43,6
43,6
59,1
59,1
59,1
59,1
70,1
70,1
57,4
70,1
80,8
80,8
70,2
80,8
34,9
56,0
39,4
56,0
50,3
80,6
56,8
50,6
65,7
105,1
34,5
65,7
80,0
128,0
42,0
80,0
M8
M10
M12
M16
M20
M24
M27
M30
[mm]
96
120
144
192
240
288
324
360
h = hmin
[mm]
126
150
174
228
288
344
384
430
c = cmin
[mm]
40
50
60
80
100
120
135
150
44,7
52,4
22,7
27,2
hef = 12 d
a)
hef = 12 d
a)
h = hmin
[mm]
M8
96
M10
120
M12
144
M16
192
M20
240
M24
288
M27
324
M30
360
[mm]
126
150
174
228
288
344
384
430
s=smin [mm]
40
50
60
80
100
120
135
Tensile Nrec: double anchor, no edge effects, min. spacing (s = smin)
HIT-V 5.8
[kN]
8,6
11,1
15,7
20,0
29,4
39,9
47,6
HIT-V 8.8
HIT-V-R
[kN]
8,6
11,1
15,7
20,0
29,4
39,9
47,6
HIT-V-HCR
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
65,7
HIT-V 8.8
[kN]
8,6
13,1
19,4
36,0
56,0
80,6
105,1
HIT-V-R
[kN]
5,9
9,1
13,7
25,2
39,4
56,8
34,5
HIT-V-HCR
[kN]
8,6
13,1
19,4
36,0
56,0
50,6
65,7
150
55,2
55,2
80,0
128,0
42,0
80,0
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
a) d = element diameter
544
1 / 2009
1 / 2009
545
Benefits
Hilti
HIT-HY 150
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
Internal
threaded sleeve
HIS-N
HIS-RN
Concrete
Small edge
distance
and spacing
Corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
546
1 / 2009
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8x90
M10x110
M12x125
M16x170
Embedment depth
hef [mm]
90
110
125
170
Base material thickness h [mm]
120
150
170
230
M20x205
205
270
M8x90
M10x110
M12x125
M16x170
M20x205
Tensile NRu,m
HIS-N
[kN]
26,3
48,3
70,4
123,9
114,5
Shear VRu,m
HIS-N
[kN]
13,7
24,2
41,0
62,0
57,8
M8x90
M10x110
M12x125
M16x170
M20x205
Tensile NRk
HIS-N
[kN]
25,0
40,0
60,0
111,9
109,0
Shear VRk
HIS-N
[kN]
13,0
23,0
39,0
59,0
55,0
M8x90
M10x110
M12x125
M16x170
M20x205
Tensile NRd
HIS-N
[kN]
17,5
26,7
40,0
62,2
74,1
Shear VRd
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
M16x170
M20x205
M8x90
M10x110
M12x125
Tensile Nrec
HIS-N
[kN]
12,5
19,0
28,6
44,4
53,0
Shear Vrec
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
1 / 2009
547
Materials
Mechanical properties of HIS-(R)N
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
HIS-N
[N/mm]
M8x90
490
M10x110
490
M12x125
460
M16x170
460
M20x205
460
Screw 8.8
[N/mm]
800
800
800
800
800
HIS-RN
[N/mm]
700
700
700
700
700
Screw A4-70
[N/mm]
700
700
700
700
700
HIS-N
[N/mm]
410
410
375
375
375
Screw 8.8
[N/mm]
640
640
640
640
640
HIS-RN
[N/mm]
350
350
350
350
350
Screw A4-70
[N/mm]
450
450
450
450
450
HIS-(R)N
[mm]
51,5
108,0
169,1
256,1
237,6
Screw
[mm]
36,6
58
84,3
157
245
[mm]
145
430
840
1595
1543
[mm]
31,2
62,3
109
277
541
HIS-(R)N
Moment of
resistance W Screw
Material quality
Part
Material
a)
b)
related fastening screw: strength class 8.8 EN ISO 898-1, A5 > 8% Ductile
steel galvanized 5m EN ISO 4042
related fastening screw: strength class 70 EN ISO 3506-1, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 EN 10088
Anchor dimensions
Anchor size
Internal threaded sleeve
HIS-N / HIS-RN
Embedment depth
hef
[mm]
M8x90
M10x110
M12x125
M16x170
M20x205
80
90
110
125
170
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
548
M8x90
M10x110
M12x125
M16x170
M20x205
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
b)
1 / 2009
549
Setting details
df
d0
hS
550
1 / 2009
Anchor size
Nominal diameter of
drill bit
Diameter of element
M8x90
M10x110
M12x125
M16x170
M20x205
d0
[mm]
14
18
22
28
32
[mm]
12,5
16,5
20,5
25,4
27,6
hef
[mm]
90
110
125
170
205
hmin
[mm]
120
150
170
230
270
df
[mm]
12
14
18
22
Effective anchorage
and drill hole depth
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Thread engagement
length; min - max
Torque moment a)
hs
[mm]
8-20
10-25
12-30
16-40
20-50
Tmax
[Nm]
10
20
40
80
150
Minimum spacing
smin
[mm]
40
45
55
65
90
cmin
[mm]
40
45
55
65
90
scr,sp
[mm]
Minimum edge
distance
Critical spacing
for splitting failure
ccr,sp
[mm]
2 ccr,sp
1,0 hef
2,26 hef
scr,N
[mm]
2 ccr,N
ccr,N
[mm]
1,5 hef
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a)
Maximum recommended torque moment to avoid splitting failure during installation with minimum spacing
and/or edge distance.
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
1 / 2009
551
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
[kN]
M8x90
17,5
13,9
M10x110
30,7
21,9
M12x125
44,7
31,6
M16x170
80,3
58,8
M20x205
74,1
69,2
M16x170
170
63,9
41,7
27,8
M20x205
205
77,8
52,8
33,3
552
[mm]
[kN]
[kN]
[kN]
M8x90
90
23,3
13,3
10,7
M10x110
110
26,7
20,0
13,3
M12x125
125
40,0
26,7
20,0
1 / 2009
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
M8
28,7
[kN]
M10
38,8
M12
47,1
M16
62,2
M20
82,3
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1,00
1,03
1,06
1,09
1,11
fB,p = (fck,cube/25N/mm)0,15 a)
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,13
1,14
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,5 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
1 / 2009
553
Influence of reinforcement
hef [mm]
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
0
VRd,c = V
Rd,c
fB f f h f4 f hef fc
[kN]
[kN]
M8x90
10,4
8,3
M10x110
18,4
12,8
M12x125
26,0
19,2
M16x170
39,3
35,3
M20x205
36,7
41,5
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a)
[kN]
= V0Rd,c fB f f h f4 f hef fc
M8
M10
M12
M16
M20
12,4
19,6
28,2
40,2
46,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
554
C 45/55
C 50/60
1,48
1,55
1 / 2009
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
M8
M10
M12
M16
M20
f hef =
1,38
1,21
1,04
1,22
1,45
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
1 / 2009
20
30
40
0,57
0,52
0,50
555
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
[kN]
17,5
26,7
40,0
62,2
74,1
HIS-RN
[kN]
13,9
21,9
31,6
58,8
69,2
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Edge distance
c = cmin
[mm]
40
45
55
65
90
Embedment depth
[kN]
11,9
13,4
20,4
30,3
40,8
HIS-RN
[kN]
11,9
13,4
20,4
30,3
40,8
[kN]
4,2
5,5
7,6
10,8
17,2
HIS-RN
[kN]
4,2
5,5
7,6
10,8
17,2
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Spacing
s = smin
[mm]
40
45
55
65
90
[kN]
14,3
16,9
24,2
35,1
45,9
HIS-RN
[kN]
13,9
16,9
24,2
35,1
45,9
556
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
1 / 2009
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
[kN]
12,5
19,1
28,6
44,4
52,9
HIS-RN
[kN]
9,9
15,6
22,6
42,0
49,4
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
5,9
9,1
13,7
25,2
29,6
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Edge distance
c = cmin
[mm]
40
45
55
65
90
[kN]
8,5
9,6
14,6
21,6
29,1
HIS-RN
[kN]
8,5
9,6
14,6
21,6
29,1
[kN]
3,0
3,9
5,4
7,7
12,3
HIS-RN
[kN]
3,0
3,9
5,4
7,7
12,3
M8x90
M10x110
M12x125
M16x170
M20x205
hef
[mm]
90
110
125
170
205
h = hmin
[mm]
120
150
170
230
270
Spacing
s = smin
[mm]
40
45
55
65
90
[kN]
10,2
12,1
17,3
25,1
32,8
HIS-RN
[kN]
9,9
12,1
17,3
25,1
32,8
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
5,9
9,1
13,7
25,2
29,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
557
Benefits
Hilti
HIT-HY 150
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Fatigue
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
a)
European technical approval
Authority / Laboratory
DIBt, Berlin
558
1 / 2009
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
8
10
12
14
16
20
25
b)
Embedment depth hef = hef,typ [mm]
80
90
110
125
170
210
240
Base material thickness h [mm]
110
120
140
165
220
270
300
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
b) hef,typ: Typical embedment depth
10
12
14
16
20
25
Tensile NRu,m
BST 500 S
[kN]
22,8
32,0
47,0
55,0
72,9
106,8
164,9
Shear VRu,m
BST 500 S
[kN]
14,7
23,1
32,6
44,1
57,8
90,3
141,8
10
12
14
16
20
25
Tensile NRk
BST 500 S
[kN]
17,1
24,0
35,2
41,2
54,7
80,1
123,7
Shear VRk
BST 500 S
[kN]
14,0
22,0
31,0
42,0
55,0
86,0
135,0
10
12
14
16
20
25
Tensile NRd
BST 500 S
[kN]
11,4
13,4
19,6
19,6
26,0
38,1
58,9
Shear VRd
BST 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
10
12
14
16
20
25
Tensile Nrec
BST 500 S
[kN]
8,1
9,5
14,0
14,0
18,6
27,2
42,1
Shear Vrec
BST 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
64,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
-40 C to +40 C
-40 C to +80 C
-40 C to +120 C
559
Materials
Mechanical properties of rebar BSt 500S
Anchor size
Nominal
BSt 500 S
tensile
strength fuk
Yield
BSt 500 S
strength fyk
Stressed
BSt 500 S
crosssection As
Moment of
resistance BSt 500 S
W
10
12
14
[N/mm]
550
[N/mm]
500
16
20
25
[mm]
50,3
78,5
113,1
153,9
201,1
314,2
490,9
[mm]
50,3
98,2
169,6
269,4
402,1
785,4
1534
Material quality
Part
rebar
BSt 500 S
Material
Mechanical properties according to DIN 488-1:1984
Geometry according to DIN 488-21:1986
Anchor dimensions
Anchor size
rebar
BSt 500 S
10
12
14
16
20
25
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
560
10
12
14
16
20
25
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
1 / 2009
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
b)
a) Note: Manual cleaning for element sizes d 14mm and embedment depth hef 10 d only!
b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm!
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
561
0 C
5 C
10 C
20 C
30 C
40 C
Working time
tgel
90 min
45 min
20 min
6 min
4 min
2 min
Curing time
a)
tcure
9 h
4,5 h
2 h
90 min
50 min
40 min
a) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing
times must be doubled.
d0
Setting details
562
1 / 2009
Anchor size
Nominal diameter of
drill bit
10
12
14
16
20
25
d0
[mm]
10
12
14
18
24
28
30
hef,min
[mm]
60
60
70
75
80
90
100
hef,max
[mm]
160
200
240
280
320
400
500
Minimum base
material thickness
hmin
[mm]
Minimum spacing
smin
[mm]
40
50
60
70
80
100
150
cmin
[mm]
40
50
60
80
100
120
150
scr,sp
[mm]
Minimum edge
distance
Critical spacing
for splitting failure
ccr,sp
[mm]
hef + 30 mm
100 mm
hef + 2 d0
2 ccr,sp
1,0 hef
2,26 hef
scr,N
[mm]
2 ccr,N
ccr,N
[mm]
1,5 hef
For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be
reduced.
a)
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
1 / 2009
563
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
10
12
14
16
20
25
20,0
30,7
44,3
60,7
79,3
123,6
192,9
564
10
12
14
16
20
25
[mm]
80
90
110
125
145
170
210
[kN]
[kN]
[kN]
11,4
8,0
6,7
13,4
9,4
7,9
19,6
13,8
11,5
19,6
13,1
11,8
26,0
17,4
15,6
38,1
25,4
22,9
58,9
39,3
35,3
1 / 2009
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
[kN]
10
12
14
16
20
25
24,1
24,0
32,4
33,6
42,0
53,3
73,2
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1,00
1,03
1,06
1,09
1,11
fB,p = (fck,cube/25N/mm)0,15 a)
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,13
1,14
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)0,5 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N 1
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N) 1
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N) 1
1 / 2009
565
Influence of reinforcement
hef [mm]
40
50
60
70
80
90
100
0,7 a)
fre,N = 0,5 + hef/200mm 1
0,75 a)
0,8 a)
0,85 a)
0,9 a)
0,95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
[kN]
8
9,3
10
14,7
12
20,7
14
28,0
16
36,7
20
57,3
25
90,0
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
[kN]
10
12
14
16
20
25
5,9
8,6
11,6
15,0
18,7
27,0
39,2
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
C 45/55
C 50/60
1,48
1,55
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
566
1 / 2009
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
1 / 2009
567
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
12,5
12,6
16,2
22,4
27,7
36,7
57,3
77,7
[kN]
8,5
8,9
[kN]
9,3
14,7
20,7
28,0
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
9,4
13,0
19,0
23,6
17,4
21,8
[kN]
5,3
6,0
8,5
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
3,5
4,9
6,6
10,0
13,2
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
100
116
138
156
170
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
11,1
15,2
20,2
[kN]
5,9
6,2
8,5
8,7
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
568
[kN]
9,3
13,6
19,2
22,7
29,3
41,9
56,5
1 / 2009
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
19,6
19,6
26,0
38,1
58,9
36,7
57,3
90,0
[kN]
11,4
13,4
[kN]
9,3
14,7
20,7
28,0
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
13,4
18,8
26,9
39,1
21,5
27,5
[kN]
7,0
8,3
12,1
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
3,7
5,3
7,3
11,2
15,8
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
18,0
25,8
40,2
Embedment depth
[kN]
8,0
9,3
13,4
13,7
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
1 / 2009
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
569
hef = 12 d a)
h = hmin
10
12
14
16
20
25
[mm]
96
120
144
168
192
240
300
[mm]
126
150
176
204
232
290
364
25,6
26,4
34,5
53,9
84,1
36,7
57,3
90,0
[kN]
13,7
17,8
[kN]
9,3
14,7
20,7
28,0
hef = 12 d a)
10
12
14
16
20
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
18,1
24,9
37,9
55,9
23,6
30,5
[kN]
8,4
11,0
15,8
Shear VRd: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
3,9
5,7
7,8
12,0
16,9
hef = 12 d a)
10
12
14
16
20
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
24,2
37,3
59,2
[kN]
9,7
12,5
17,9
18,7
Shear VRd: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
a) d = element diameter
570
1 / 2009
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
8,9
9,0
11,6
16,0
19,8
26,2
40,9
55,5
[kN]
6,1
6,4
[kN]
6,6
10,5
14,8
20,0
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
102
116
130
150
174
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
6,7
9,3
13,6
16,9
12,4
15,6
[kN]
3,8
4,3
6,1
Shear Vrec: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
2,5
3,5
4,7
7,1
9,4
10
12
14
16
20
25
hef = hef,min
[mm]
60
60
70
80
90
100
110
h = hmin
[mm]
100
100
100
116
138
156
170
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
7,9
10,9
14,4
[kN]
4,2
4,4
6,1
6,2
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
6,6
9,7
13,7
16,2
20,9
29,9
40,4
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
571
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
14,0
14,0
18,6
27,2
42,1
26,2
40,9
64,3
[kN]
8,1
9,6
[kN]
6,6
10,5
14,8
20,0
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
9,6
13,4
19,2
27,9
15,4
19,6
[kN]
5,0
5,9
8,6
Shear Vrec: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
2,6
3,8
5,2
8,0
11,3
10
12
14
16
20
25
hef = hef,typ
[mm]
80
90
110
125
145
170
210
h = hmin
[mm]
110
120
142
161
185
220
274
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
17,3
26,6
42,3
Embedment depth
[kN]
6,9
8,9
12,8
13,4
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
6,6
10,5
14,8
20,0
26,2
40,9
64,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
572
1 / 2009
10
12
14
16
20
25
hef = 12 d *
[mm]
96
120
144
168
192
240
300
h = hmin
[mm]
126
150
176
204
232
290
364
18,3
18,9
24,6
38,5
60,1
26,2
40,9
64,3
[kN]
9,8
12,7
[kN]
6,6
10,5
14,8
20,0
10
12
14
16
20
hef = 12 d *
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Edge distance
c = cmin
[mm]
40
50
60
80
100
120
135
12,9
17,8
27,1
39,9
16,9
21,8
[kN]
6,0
7,9
11,3
Shear Vrec: single anchor, min. edge distance (c = cmin), without lever arm
BSt 500 S
[kN]
2,8
4,1
5,6
8,6
12,1
10
12
14
16
20
hef = 12 d *
[mm]
96
120
144
168
192
240
25
300
h = hmin
[mm]
126
150
176
204
232
290
364
Spacing
s = smin
[mm]
40
50
60
80
100
120
135
17,3
26,6
42,3
[kN]
6,9
8,9
12,8
13,4
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin), without lever arm
BSt 500 S
[kN]
6,6
10,5
14,8
20,0
26,2
40,9
64,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
a) d = element diameter
1 / 2009
573
Hilti HIT-ICE
with HIT-V / HAS
Benefits
Hilti
HIT-ICE
296 ml cartridge
Statik mixer
HAS rod
HAS-E rod
HIT-V rod
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Corrosion
resistance
High
corrosion
resistance
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
M20
M24
Typical embedment depth [mm]
80
90
110
125
170
210
Base material thickness [mm]
110
120
140
165
220
270
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
574
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Anchor size
M8
M10
M20
M24
Tensile NRu,m
HIT-V 5.8
[kN]
18,9
30,5
44,1
59,9
101,9
127,1
Shear VRu,m
HIT-V 5.8
[kN]
9,5
15,8
22,1
41,0
64,1
92,4
M8
M10
M20
M24
Tensile NRk
HIT-V 5.8
[kN]
17,6
23,5
35,3
44,9
76,4
95,3
Shear VRk
HIT-V 5.8
[kN]
9,0
15,0
21,0
39,0
61,0
88,0
M8
M10
M20
M24
Tensile NRd
HIT-V 5.8
[kN]
8,4
11,2
16,8
21,4
36,4
45,4
Shear VRd
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIT-V 5.8
Anchor size
M8
M10
M20
M24
Tensile Nrec
HIT-V 5.8
[kN]
6,0
8,0
12,0
15,3
26,0
32,4
Shear Vrec
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
Temperature range I
-40 C to +70 C
1 / 2009
575
Hilti HIT-ICE
with HIT-V / HAS
Materials
Mechanical properties of HIT-V / HAS
Anchor size
HIT-V/HAS 5.8
Nominal
HIT-V/HAS 8.8
tensile
strength fuk HIT-V/HAS -R
HIT-V/HAS -HCR
HIT-V/HAS 5.8
HIT-V/HAS 8.8
Yield
strength fyk HIT-V/HAS -R
HIT-V/HAS -HCR
Stressed
HAS
crosssection As HIT-V
Moment of HAS
resistance
HIT-V
W
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
500
800
700
800
400
640
450
600
M10
500
800
700
800
400
640
450
600
M20
500
800
700
800
400
640
450
600
M24
500
800
700
700
400
640
450
400
[mm]
32,8
52,3
76,2
144
225
324
[mm]
36,6
58,0
84,3
157
245
353
[mm]
31,2
62,3
109
277
541
935
[mm]
27,0
54,1
93,8
244
474
809
Material quality
Part
Threaded rod
HIT-V(F), HAS 5.8
Threaded rod
HIT-V(F), HAS 8.8
Threaded rod
HIT-V-R, HAS-R
Threaded rod
HIT-V-HCR, HAS-HCR
Washer
ISO 7089
Nut
EN ISO 4032
576
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Strength class 8.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Stainless steel grade A4, A5 > 8% ductile
strength class 70, EN ISO 3506-1,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
M24: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN 10088: 1.4529; 1.4565
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
hot dipped galvanized 45 m, EN ISO 10684
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
Anchor dimensions
Anchor rod
HIT-V, HIT-V-R, HIT-V-HCR
M24
M24x210
M20
M20x170
[mm]
M16
M16x125
M12
M12x110
Anchor rod
HAS, HAS-E,
HAS-R, HAS-ER
HAS-HCR
M10
M10x90
M8
M8x80
Anchor size
80
90
110
125
170
210
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
1 / 2009
M8
M10
M12
M16
M20
M24
TE 2 TE 16
TE 40 TE 50
compressed air gun or blow out pump, set of cleaning brushes, dispenser
577
Hilti HIT-ICE
with HIT-V / HAS
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.
578
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
1 / 2009
579
Hilti HIT-ICE
with HIT-V / HAS
Setting details
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
range a)
Minimum base
material thickness b)
Diameter of clearance
hole in the fixture
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
M8
M10
M20
M24
d0
[mm]
10
12
14
18
24
28
hef,min
[mm]
60
60
70
80
90
96
hef,max
[mm]
160
200
240
320
400
480
hmin
[mm]
df
[mm]
12
14
18
22
26
smin
[mm]
40
50
60
80
100
120
cmin
[mm]
40
50
60
80
100
120
80
150
200
hef + 30 mm
100 mm
hef + 2 d0
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1.5 hef
Tinst
[Nm]
10
20
40
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
580
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
1 / 2009
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
11,1
12,0
17,7
19,3
12,4
13,9
17,7
19,3
M10
17,6
19,3
28,2
30,7
19,8
21,9
28,2
30,7
M20
74,8
82,0
119,6
130,7
84,1
92,0
119,6
130,7
M24
106,8
118,0
170,9
188,0
120,2
132,1
106,8
117,6
581
Hilti HIT-ICE
with HIT-V / HAS
[kN]
M8
M10
80
90
110
8,4
11,2
16,8
M20
M24
125
170
200
21,4
36,4
45,4
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
[kN]
M8
17,2
M10
20,5
M20
53,3
M24
73,2
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0.1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
582
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
0,1
s/scr,sp
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
40
a)
50
60
a)
a)
70
80
a)
90
a)
100
a)
0,7
fre,N = 0,5 + hef/200mm 1
0,75
0,8
0,85
0,9
0,95
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V0Rd,c fB f f h f4 f hef fc
1 / 2009
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
6,6
7,2
10,6
12,0
7,5
8,3
10,6
12,0
M10
10,6
12,0
16,9
18,4
11,9
12,8
16,9
18,4
M20
44,9
48,8
71,8
78,4
50,5
55,1
71,8
78,4
M24
64,1
70,4
102,6
112,8
72,1
79,5
64,1
70,9
583
Hilti HIT-ICE
with HIT-V / HAS
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
[kN]
M8
M10
M12
M16
M20
M24
5,9
8,6
11,6
18,7
27,0
36,6
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
584
{h/(1,5 c)}
1/2
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
20
30
40
0,57
0,52
0,50
1 / 2009
585
Hilti HIT-ICE
with HIT-V / HAS
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm
Hilti technical data
Anchor size
M8
M10
M12
M16
Embedment depth
hef,1 = [mm]
60
60
72
96
Base material thickness hmin= [mm]
100
100
102
132
Tensile NRd: single anchor, no edge effects
HIT-V 5.8
HIT-V 8.8
[kN]
6,3
7,5
11,0
16,4
HIT-V-R
HIT-V-HCR
Shear VRd: single anchor, no edge effects, without lever arm
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
HIT-V 8.8
[kN]
12,0
18,4
27,2
46,0
HIT-V-R
[kN]
8,3
12,8
19,2
35,3
HIT-V-HCR
[kN]
12,0
18,4
27,2
46,0
M20
120
168
M24
144
200
25,7
31,1
48,8
71,9
55,1
71,9
70,4
87,2
79,5
70,9
M20
120
168
100
M24
144
200
120
17,3
21,0
15,7
21,4
586
M24
144
200
120
21,3
55,7
55,7
55,7
55,7
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
M20
170
218
M24
210
266
36,4
45,4
48,8
78,4
55,1
78,4
70,4
112,8
79,5
70,9
M20
170
218
100
M24
210
266
120
23,5
30,7
17,2
23,6
M20
170
218
100
M24
210
266
120
24,9
31,9
[kN]
5,2
7,0
10,4
13,8
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIT-V 5.8
HIT-V 8.8
HIT-V-R
HIT-V-HCR
[kN]
3,7
5,3
7,3
11,5
[kN]
5,9
7,8
11,5
14,8
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
1 / 2009
HIT-V 5.8
[kN]
7,2
12,0
16,8
31,2
48,8
70,4
HIT-V 8.8
[kN]
12,0
18,4
27,2
36,4
61,0
75,7
HIT-V-R
[kN]
8,3
12,8
19,2
35,3
55,1
75,7
HIT-V-HCR
[kN]
12,0
18,4
27,2
36,4
61,0
70,9
587
Hilti HIT-ICE
with HIT-V / HAS
M20
240
288
M24
288
344
51,4
62,3
48,8
78,4
55,1
78,4
70,4
112,8
79,5
70,9
M20
240
288
100
M24
288
344
120
33,2
42,1
18,9
25,9
588
M24
288
344
120
44,6
70,4
99,3
79,5
70,9
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm
Hilti technical data
Anchor size
M8
M10
M12
M16
Embedment depth
hef,1 = [mm]
60
60
72
96
Base material thickness hmin= [mm]
100
100
102
132
Tensile Nrec: single anchor, no edge effects
HIT-V 5.8
HIT-V 8.8
[kN]
4,5
5,3
7,9
11,7
HIT-V-R
HIT-V-HCR
Shear Vrec: single anchor, no edge effects, without lever arm
HIT-V 5.8
[kN]
5,1
8,6
12,0
22,3
HIT-V 8.8
[kN]
8,6
13,1
19,4
32,9
HIT-V-R
[kN]
6,0
9,2
13,7
25,2
HIT-V-HCR
[kN]
8,6
13,1
19,4
32,9
M20
120
168
M24
144
200
18,4
22,2
34,9
51,4
39,4
51,4
50,3
62,3
56,8
50,6
M20
120
168
100
M24
144
200
120
12,4
15,0
11,2
15,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
589
Hilti HIT-ICE
with HIT-V / HAS
M24
144
200
120
15,2
39,8
39,8
39,8
39,8
M20
170
218
M24
210
266
26,0
32,4
34,9
56,0
39,4
56,0
50,3
80,6
56,8
50,6
M20
170
218
100
M24
210
266
120
16,8
21,9
12,3
16,9
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
590
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
M24
210
266
120
22,8
50,3
54,0
54,0
50,6
M20
240
288
M24
288
344
36,7
44,5
34,9
56,0
39,4
56,0
50,3
80,6
56,8
50,6
M20
240
288
100
M24
288
344
120
23,7
30,1
13,5
18,5
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
591
Hilti HIT-ICE
with HIT-V / HAS
M24
288
344
120
31,8
50,3
70,9
56,8
50,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
592
1 / 2009
Hilti HIT-ICE
with HIT-V / HAS
1 / 2009
593
Hilti HIT-ICE
with HIS
Benefits
Hilti
HIT-ICE
296 ml cartridge
Statik mixer
HIS-(R)N sleeve
Concrete
Small edge
distance
and spacing
Corrosion
resistance
Hilti anchor
design
software
Embedment depth and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Anchor size
M8
M10
M12
M16
Embedment depth [mm]
90
110
125
170
Base material thickness [mm]
120
150
170
230
M20
205
270
Mean ultimate resistance a): concrete C 20/25 fck,cube = 25 N/mm, anchor HIS-N
Anchor size
M8
M10
M16
M20
Tensile NRu,m
HIS-N
[kN]
27,3
48,2
61,0
105,6
114,5
Shear VRu,m
HIS-N
[kN]
13,7
24,2
41,0
62,0
57,8
594
1 / 2009
Hilti HIT-ICE
with HIS
M8
M10
M16
M20
Tensile NRk
HIS-N
[kN]
24,2
36,1
45,8
79,2
94,7
Shear VRk
HIS-N
[kN]
13,0
23,0
39,0
59,0
55,0
M8
M10
M16
M20
Tensile NRd
HIS-N
[kN]
11,5
17,2
21,8
37,7
45,1
Shear VRd
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
M8
M10
M16
M20
Tensile Nrec
HIS-N
[kN]
8,2
12,3
15,6
26,9
32,2
Shear Vrec
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
Temperature range I
-40 C to +70 C
1 / 2009
595
Hilti HIT-ICE
with HIS
Materials
Mechanical properties of HIS-(R)N
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
Moment of
resistance W
M10
490
800
700
700
410
640
350
450
M16
460
800
700
700
375
640
350
450
M20
460
800
700
700
375
640
350
450
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
HIS-N
Screw 8.8
HIS-RN
Screw A4-70
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
490
800
700
700
410
640
350
450
HIS-(R)N
[mm]
51,5
108,0
169,1
256,1
237,6
Screw
[mm]
36,6
58
84,3
157
245
HIS-(R)N
Screw
[mm]
[mm]
145
31,2
430
62,3
840
109
1595
277
1543
541
Material quality
Part
Material
C-steel 1.0718, EN 10277-3
internally threaded sleeves a)
HIS-N
steel galvanized 5m EN ISO 4042
internally threaded sleeves b)
stainless steel 1.4401 and 1.4571 EN 10088
HIS-RN
a) related fastening screw: strength class 8.8 EN ISO 898-1, A5 > 8% Ductile
steel galvanized 5m EN ISO 4042
b) related fastening screw: strength class 70 EN ISO 3506-1, A5 > 8% Ductile
stainless steel 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362 EN 10088
Anchor dimensions
Anchor size
Internal sleeve
HIS-(R)N
Anchor embedment depth
[mm]
M8
M10
M12
M16
M20
M8x90
M10x110
M12x125
M16x170
M20x205
90
110
125
170
205
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
596
M8
M10
M12
M16
M20
TE 2 TE 16
TE 40 TE 50
compressed air gun or blow out pump, set of cleaning brushes, dispenser
1 / 2009
Hilti HIT-ICE
with HIS
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
1 / 2009
597
Hilti HIT-ICE
with HIS
598
1 / 2009
Hilti HIT-ICE
with HIS
Setting details
Anchor size
Nominal diameter of
drill bit
Diameter of element
Effective anchorage
and drill hole depth
Minimum base
material thickness a)
Diameter of clearance
hole in the fixture
Thread engagement
length; min - max
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
M8
M10
M16
M20
d0
[mm]
14
18
22
28
32
[mm]
12,5
16,5
20,5
25,4
27,6
hef
[mm]
90
110
125
170
205
hmin
[mm]
120
150
170
230
270
df
[mm]
12
14
18
22
hs
[mm]
8-20
10-25
12-30
16-40
20-50
smin
[mm]
40
45
55
65
90
cmin
[mm]
40
45
55
65
90
80
150
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
b)
Tinst
[Nm]
1.5 hef
10
20
40
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
c)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
1 / 2009
599
Hilti HIT-ICE
with HIS
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
[kN]
M8
17,4
13,9
M10
30,7
21,9
M16
80,3
58,8
M20
74,1
69,2
M16
M20
600
[kN]
M8
M10
90
110
125
170
205
11,5
17,2
21,8
37,7
45,1
1 / 2009
Hilti HIT-ICE
with HIS
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
M8
20,5
[kN]
M10
27,7
M16
53,3
M20
70,6
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0.1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N)
1 / 2009
601
Hilti HIT-ICE
with HIS
Influence of reinforcement
hef [mm]
80
90
100
0.9 a)
fre,N = 0.5 + hef/200mm 1
0.95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
VRd,c = V
Rd,c
fB f f h f4 f hef fc
[kN]
[kN]
M8
10,4
8,3
M10
18,4
12,8
M16
39,3
35,3
M20
36,7
41,5
Design concrete pryout resistance VRd,cp = lower value a) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
[kN]
= V0Rd,c fB f f h f4 f hef fc
M8
M10
M12
M16
M20
12,4
19,6
28,2
40,2
46,2
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
1/2 a)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
602
C 45/55
C 50/60
1,48
1,55
1 / 2009
Hilti HIT-ICE
with HIS
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
M8
M10
M12
M16
M20
f hef =
1,38
1,21
1,04
1,22
1,45
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
1 / 2009
20
30
40
0,57
0,52
0,50
603
Hilti HIT-ICE
with HIS
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm
Anchor size
M8
M10
Embedment depth
hef = [mm]
90
110
Base material thickness hmin= [mm]
120
150
Tensile NRd: single anchor, no edge effects
HIS-(R)N
[kN]
11,5
M16
170
230
M20
205
270
21,8
37,7
45,1
17,2
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
M16
170
230
65
M20
205
270
90
19,1
25,5
[kN]
6,1
8,8
11,3
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
HIS-(R)N
[kN]
4,2
5,5
7,6
10,8
17,2
M16
170
230
65
M20
205
270
90
23,8
29,9
[kN]
7,7
11,2
14,1
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
604
HIS-N
[kN]
10,4
18,4
26,0
39,3
36,7
HIS-RN
[kN]
8,3
12,8
19,2
35,3
41,5
1 / 2009
Hilti HIT-ICE
with HIS
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm
Anchor size
M8
M10
Embedment depth
hef = [mm]
90
110
Base material thickness hmin= [mm]
120
150
Tensile Nrec: single anchor, no edge effects
HIS-(R)N
[kN]
8,2
12,3
M16
170
230
M20
205
270
15,6
26,9
32,2
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
6,0
9,2
13,7
25,2
29,6
M16
170
230
65
M20
205
270
90
13,7
18,2
[kN]
4,4
6,3
8,1
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
HIS-(R)N
[kN]
3,0
3,9
5,5
7,7
12,3
M16
170
230
65
M20
205
270
90
17,0
21,4
[kN]
5,5
8,0
10,1
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
HIS-N
[kN]
7,4
13,1
18,6
28,1
26,2
HIS-RN
[kN]
6,0
9,2
13,7
25,2
29,6
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
605
Hilti HIT-ICE
with rebar
Benefits
Hilti
HIT-ICE
296 ml cartridge
Statik mixer
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Embedment depth a) and base material thickness for the basic loading data.
Mean ultimate resistance, characteristic resistance, design resistance, recommended loads.
Hilti technical data
Anchor size
8
10
12
14
16
20
25
Typical embedment depth [mm]
80
90
110
125
125
170
210
Base material thickness [mm]
110
120
145
165
165
220
275
a) The allowed range of embedment depth is shown in the setting details. The corresponding load values can be
calculated according to the simplified design method.
606
1 / 2009
Hilti HIT-ICE
with rebar
Mean ultimate resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500S
Anchor size
10
20
25
Tensile NRu,m
BSt 500 S
[kN]
20,2
28,3
40,0
51,8
63,6
84,6
105,8
Shear VRu,m
BSt 500 S
[kN]
14,7
23,1
32,6
44,1
57,8
90,3
141,8
Characteristic resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size
10
20
25
Tensile NRk
BSt 500 S
[kN]
15,1
21,2
30,0
38,9
47,7
63,4
79,4
Shear VRk
BSt 500 S
[kN]
14,0
22,0
31,0
42,0
55,0
86,0
135,0
Design resistance: concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size
10
20
25
Tensile NRd
BSt 500 S
[kN]
7,2
10,1
14,3
18,5
22,7
30,2
37,8
Shear VRd
BSt 500 S
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
90,0
Recommended loads a): concrete C 20/25 fck,cube = 25 N/mm, anchor rebar BSt 500 S
Anchor size
10
20
25
Tensile Nrec
BSt 500 S
[kN]
5,1
7,2
10,2
13,2
16,2
21,6
27,0
Shear Vrec
BSt 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
64,3
a) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
G = 1,35 for permanent actions and Q = 1,5 for variable actions.
Base material
temperature
Temperature range I
-40 C to +40 C
1 / 2009
607
Hilti HIT-ICE
with rebar
Materials
Mechanical properties of rebar BSt 500S
Anchor size
Nominal
BSt 500 S
tensile
strength fuk
Yield
strength fyk
Stressed
BSt 500 S
crosssection As
Moment of
resistance BSt 500 S
W
10
20
25
[N/mm]
550
550
550
550
550
550
550
[N/mm]
500
500
500
500
500
500
500
[mm]
50,3
78,5
113,1
153,9
201,1
314,2
490,9
[mm]
50,3
98,2
169,6
269,4
402,1
785,4
1534
Material quality
Part
rebar
BSt 500 S
Material
Geometry and mechanical properties according to DIN 488-2:1986 or
E DIN 488-2:2006
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
608
10
12
14
16
20
25
TE 2 TE 16
TE 40 TE 70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
1 / 2009
Hilti HIT-ICE
with rebar
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
Brush bore hole with required steel brush HIT-RB
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
609
Hilti HIT-ICE
with rebar
610
1 / 2009
Hilti HIT-ICE
with rebar
Setting details
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
range a)
Minimum base
material thickness b)
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
10
20
25
d0
[mm]
12
14
16
18
20
25
32
hef,min
[mm]
60
60
70
75
80
90
100
hef,max
[mm]
160
200
240
280
320
400
500
hmin
[mm]
smin
cmin
[mm]
hef + 30 mm
100 mm
40
50
60
70
80
100
125
[mm]
40
60
70
80
100
125
50
hef + 2 d0
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
2,26 hef
scr,N
2 ccr,N
ccr,N
1.5 hef
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
a)
b)
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
1 / 2009
611
Hilti HIT-ICE
with rebar
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
[kN]
8
20,0
10
30,7
20
123,6
25
192,9
20
25
612
[kN]
10
80
90
110
125
125
170
210
7,2
10,1
14,3
18,5
22,7
30,2
37,8
1 / 2009
Hilti HIT-ICE
with rebar
Design concrete cone resistance NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
Anchor size
N0Rd,c
[kN]
8
17,2
10
20,5
20
53,3
25
73,2
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB,p = (fck,cube/25N/mm)0,1 a)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,08
1,09
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
C 45/55
C 50/60
1,48
1,55
0,7 + 0,3c/ccr,N
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
0,1
s/scr,sp
f3,N =
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,5(1 + s/scr,N)
1 / 2009
613
Hilti HIT-ICE
with rebar
Influence of reinforcement
hef [mm]
40
50
60
70
80
90
100
0.7 a)
fre,N = 0.5 + hef/200mm 1
0.75 a)
0.8 a)
0.85 a)
0.9 a)
0.95 a)
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre,N = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
0
VRd,c = V
Rd,c
fB f f h f4 f hef fc
[kN]
8
9,3
10
14,7
20
57,3
25
90,0
Design concrete pryout resistance VRd,cp = lower value a) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
= V0Rd,c fB f f h f4 f hef fc
[kN]
10
12
14
16
20
25
5,9
8,6
11,6
15,0
18,7
27,0
39,2
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
C 45/55
C 50/60
1,48
1,55
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
fB =
(fck,cube/25N/mm)1/2 a)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
614
1 / 2009
Hilti HIT-ICE
with rebar
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
{h/(1,5 c)}
1/2
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Single
anchor 0,75 1,50
0,50
0,35
0,27 0,35
0,75
0,65
0,43 0,54
1,00
1,00
0,63 0,75
1,25
1,40
0,84 0,98
1,50
1,84
1,07 1,22
1,75
2,32
1,32 1,49
2,00
2,83
1,59 1,77
2,25
3,38
1,88 2,06
2,50
3,95
2,17 2,37
2,75
4,56
2,49 2,69
3,00
5,20
2,81 3,03
3,25
5,86
3,15 3,38
3,50
6,55
3,51 3,74
3,75
7,26
3,87 4,12
4,00
8,00
4,25 4,50
4,25
8,76
4,64 4,90
4,50
9,55
5,04 5,30
4,75
10,35 5,45 5,72
5,00
11,18 5,87 6,15
5,25
12,03 6,30 6,59
5,50
12,90 6,74 7,04
a) The anchor spacing and the
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
c/d
0,19
10
15
0,77
0,71
0,67
0,65
0,60
fc =
(d / c)
a) The edge distance shall not be smaller than the minimum edge distance cmin.
1 / 2009
20
30
40
0,57
0,52
0,50
615
Hilti HIT-ICE
with rebar
Precalculated values
Design resistance: concrete C 20/25 fck,cube = 25 N/mm
Hilti technical data
12
14
16
70
75
80
104
120
136
20
90
170
25
100
214
9,4
17,4
21,3
27,0
36,7
57,3
75,6
20
90
170
100
25
100
214
125
14,5
19,5
10,8
15,7
22,9
20
90
170
100
25
100
214
125
14,8
19,4
Anchor size
8
10
Embedment depth
hef,1 = [mm]
60
60
Base material thickness hmin= [mm]
100
100
Tensile NRd: single anchor, no edge effects
BSt 500 S
[kN]
5,4
6,7
12,4
[kN]
9,3
14,7
20,7
28,0
BSt 500 S
[kN]
3,4
4,5
6,3
8,4
11,8
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
3,5
4,9
6,7
8,6
BSt 500 S
[kN]
3,8
4,7
6,6
8,6
11,8
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
616
[kN]
9,2
12,0
16,7
22,2
31,2
38,1
48,3
1 / 2009
Hilti HIT-ICE
with rebar
20
170
220
25
210
274
14,3
22,7
30,2
37,8
36,7
57,3
90,0
20
170
220
100
25
210
274
125
20,5
27,2
11,5
17,2
25,0
20
170
220
100
25
210
274
125
21,5
27,6
Anchor size
8
10
Embedment depth
hef,typ = [mm]
80
90
Base material thickness hmin= [mm]
110
120
Tensile NRd: single anchor, no edge effects
BSt 500 S
[kN]
7,2
10,1
18,5
[kN]
9,3
14,7
20,7
28,0
BSt 500 S
[kN]
4,6
6,4
9,2
12,0
14,4
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
3,7
5,3
7,3
9,5
BSt 500 S
[kN]
5,2
7,2
10,1
13,0
15,5
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
1 / 2009
[kN]
9,3
14,7
20,7
28,0
36,7
50,6
63,4
617
Hilti HIT-ICE
with rebar
20
240
290
25
300
364
18,7
34,9
42,6
54,0
36,7
57,3
90,0
20
240
290
100
25
300
364
125
28,9
38,9
12,9
18,9
27,8
20
240
290
100
25
300
364
125
30,9
40,0
Anchor size
8
10
Embedment depth
hef,2 = [mm]
96
120
Base material thickness hmin= [mm]
126
150
Tensile NRd: single anchor, no edge effects
BSt 500 S
[kN]
8,6
13,5
24,9
[kN]
9,3
14,7
20,7
28,0
BSt 500 S
[kN]
5,5
8,6
12,0
16,1
22,2
Shear VRd: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
3,9
5,7
7,8
10,2
BSt 500 S
[kN]
6,3
9,7
13,4
17,8
24,5
Shear VRd: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
618
[kN]
9,3
14,7
20,7
28,0
36,7
57,3
86,1
1 / 2009
Hilti HIT-ICE
with rebar
Precalculated values
Recommended loads: concrete C 20/25 fck,cube = 25 N/mm
Hilti technical data
12
14
16
70
75
80
104
120
136
20
90
170
25
100
214
6,7
12,5
15,2
19,3
26,2
41,0
54,0
20
90
170
100
25
100
214
125
10,3
13,9
7,7
11,2
16,3
20
90
170
100
25
100
214
125
10,6
13,9
Anchor size
8
10
Embedment depth
hef,1 = [mm]
60
60
Base material thickness hmin= [mm]
100
100
Tensile Nrec: single anchor, no edge effects
BSt 500 S
[kN]
3,9
4,8
8,9
[kN]
6,7
10,5
14,8
20,0
BSt 500 S
[kN]
2,5
3,2
4,5
6,0
8,4
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
2,5
3,5
4,8
6,2
BSt 500 S
[kN]
2,7
3,4
4,7
6,2
8,5
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
6,6
8,6
12,0
15,9
22,3
27,2
34,5
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
619
Hilti HIT-ICE
with rebar
20
170
220
25
210
274
10,2
16,2
21,6
27,0
26,2
41,0
64,3
20
170
220
100
25
210
274
125
14,6
19,5
8,2
12,3
17,9
20
170
220
100
25
210
274
125
15,4
19,7
Anchor size
8
10
Embedment depth
hef,typ = [mm]
80
90
Base material thickness hmin= [mm]
110
120
Tensile Nrec: single anchor, no edge effects
BSt 500 S
[kN]
5,1
7,2
13,2
[kN]
6,7
10,5
14,8
20,0
BSt 500 S
[kN]
3,3
4,6
6,6
8,6
10,3
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
2,7
3,8
5,2
6,8
BSt 500 S
[kN]
3,7
5,1
7,2
9,3
11,0
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
36,1
45,3
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
620
1 / 2009
Hilti HIT-ICE
with rebar
20
240
290
25
300
364
13,4
24,9
30,5
38,6
26,2
41,0
64,3
20
240
290
100
25
300
364
125
20,7
27,8
9,2
13,5
19,9
20
240
290
100
25
300
364
125
22,0
28,6
Anchor size
8
10
Embedment depth
hef,2 = [mm]
96
120
Base material thickness hmin= [mm]
126
150
Tensile Nrec: single anchor, no edge effects
BSt 500 S
[kN]
6,2
9,6
17,8
[kN]
6,7
10,5
14,8
20,0
BSt 500 S
[kN]
3,9
6,1
8,6
11,5
15,8
Shear Vrec: single anchor, min. edge distance (c = cmin) , without lever arm
BSt 500 S
[kN]
2,8
4,1
5,6
7,3
BSt 500 S
[kN]
4,5
6,9
9,6
12,7
17,5
Shear Vrec: double anchor, no edge effects, min. spacing (s = smin) , without lever arm
BSt 500 S
[kN]
6,7
10,5
14,8
20,0
26,2
41,0
61,5
For the recommended loads an overall partial safety factor for action = 1,4 is considered. The partial safety
factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001,
annex C, the partial safety factor is G = 1,35 for permanent actions and Q = 1,5 for variable actions.
1 / 2009
621
Hilti HIT-HY 70
Benefits
Hilti HITHY 70 330 ml
foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Mixer
HIT-V rod
HAS, HAS-E rod
HIT-AC, HITACR rod
HIT-AN rod
HIT-IG internal
threaded sleeve
HIT-IC internal
threaded sleeve
HIS-RN sleeve
HIT-SC
composite
sleeve
HCR
Concrete
Variable
embedment
depth
Solid brick
Hollow brick
Autoclaved
aerated
concrete
Fire
resistance
Corrosion
resistance
High
corrosion
resistant
Hilti anchor
design
software
Approvals / certificates
Description
Allgemeine bauaufsichtliche
Zulassung
(national German approval)
Fiche technique SOCOTEC a)
Fire test report
Assessment report (fire)
622
Authority / Laboratory
DIBt, Berlin
Z-21.3-1830 / 2006-11-14
SOCOTEC, Paris
MFPA, Leipzig
warringtonfire
YX 0047 08.2006
PB III/B-07-157 / 2007-06-04
WF 166402 / 2007-10-26
1 / 2009
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG
HIT-IG / HIT-IC e)
Setting
depth
[mm]
M8
M10
M12
M8
M10
M12
Nrec [kN]
1,0
1,7
1,7
1,7
1,7
1,7
Vrec [kN]
1,0
1,7
1,7
1,7
1,7
1,7
Nrec [kN]
3,0 c)
3,0 c)
3,0 c)
3,0 c)
3,0 c)
3,0 c)
Vrec [kN]
3,0 c)
3,0 c)
3,0 c)
3,0 c)
3,0 c)
3,0 c)
Nrec [kN]
1,0
1,7
1,7
1,7
1,7
1,7
Vrec [kN]
1,0
1,7
1,7
1,7
1,7
1,7
Nrec [kN]
3,0 d)
3,0 d)
3,0 d)
3,0 d)
3,0 d)
3,0 d)
80
Germany,
Austria,
Switzerland
Solid sandlime brick
KS 12/2,0
DIN 106/
EN 771-2
fb b) 12 N/mm
M6
80
Germany,
Austria,
Vrec [kN]
3,0 d)
3,0 d)
3,0 d)
3,0 d)
3,0 d)
3,0 d)
Switzerland
a) Recommended load values for German base materials are based on national regulations.
b) fb = brick strength
c) Values only valid for Mz (DIN 105) with brick strength 29 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 7,1cm), not covered by national German approval Z-21.3-1830 / 2006-11-14
d) Values only valid for KS (DIN 106) with brick strength 23 N/mm, density 2,0 kg/dm, minimum brick size NF
(24,0cm x 11,5cm x 7,1cm), not covered by national German approval Z-21.3-1830 / 2006-11-14
e) HIT-IC not covered by national German approval Z-21.3-1830 / 2006-11-14
1 / 2009
623
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC
HIT-IG / HIT-IC c)
Germany,
Austria,
Switzerland
Setting
depth
[mm]
M6
M8
M10
M12
M8
M10
M12
Nrec [kN]
0,5
0,6
0,6
0,6
0,6
0,6
Vrec [kN]
0,1
0,1
0,2
0,2
0,4
0,4
80
Lightweight
concrete acc.
Nrec [kN]
1,0
1,0
1,5
1,5
1,5
TGL
(haufwerks80
poriger
Leichtbeton),
Vrec [kN]
1,0
1,0
1,5
1,5
1,5
Germany
a) Recommended load values for German base materials are based on national regulations.
b) fb = brick strength
c) HIT-IC not covered by national German approval Z-21.3-1830 / 2006-11-14
624
1,5
1,5
1 / 2009
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-IC c) / HIT-IG
M6
Setting
depth
[mm]
M10
M12
M8
M10
M12
0,3
0,4
0,4
0,8
0,8
Vrec [kN]
0,3
0,4
0,4
0,4
0,8
Nrec [kN]
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
Vrec [kN]
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
Nrec [kN]
0,8
0,8
0,8
0,8
Vrec [kN]
0,8
0,8
0,8
0,8
Nrec [kN]
0,84
0,84
0,8
0,8
Vrec [kN]
0,8
0,8
0,8
0,8
Nrec [kN]
0,91
0,91
0,8
0,8
Vrec [kN]
0,8
0,8
0,8
0,8
Nrec [kN]
0,6
0,8
0,8
0,8
0,8
Vrec [kN]
0,6
0,8
0,8
0,8
0,8
Nrec [kN]
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
Vrec [kN]
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
Nrec [kN]
1,54
1,54
1,54
1,54
Vrec [kN]
1,4
1,4
1,4
1,4
Nrec [kN]
1,68
1,68
1,54
1,54
Vrec [kN]
1,4
1,4
1,4
1,4
Nrec [kN]
1,82
1,82
1,54
1,54
Vrec [kN]
1,4
1,4
1,4
1,4
Recommended load values for German base materials are based on national regulations.
fb = brick strength
HIT-IC elements are not covered by national German approval Z-21.3-1830 / 2006-11-14
HIT-SC 18x elements are not covered by national German approval Z-21.3-1830 / 2006-11-14
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
HlzB 6
DIN 105/
EN 771-1
fb b) 6 N/mm
50
80
100
Germany,
Austria,
Switzerland
Hlz 12
DIN 105/
EN 771-1
fb b) 12 N/mm
130
160
50
80
100
Germany,
Austria,
Switzerland
a)
b)
c)
d)
e)
M8
1 / 2009
130
160
625
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-IC c) / HIT-IG
M6
Setting
depth
[mm]
M12
M8
M10
M12
0,7
0,7
0,7
0,7
Vrec [kN]
0,5
0,7
0,7
0,7
0,7
Nrec [kN]
1,4
1,4
1,4
1,4
1,4
1,4
1,0
1,0
Vrec [kN]
1,4
1,4
1,4
1,4
1,4
1,4
1,0
1,0
Nrec [kN]
1,4
1,4
1,4
1,4
Vrec [kN]
1,4
1,4
1,4
1,4
Nrec [kN]
1,44
1,44
1,4
1,4
Vrec [kN]
1,4
1,4
1,4
1,4
Nrec [kN]
1,56
1,56
1,4
1,4
Vrec [kN]
1,4
1,4
1,4
1,4
Recommended load values for German base materials are based on national regulations.
fb = brick strength
HIT-IC elements are not covered by national German approval Z-21.3-1830 / 2006-11-14
HIT-SC 18x elements are not covered by national German approval Z-21.3-1830 / 2006-11-14
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
50
80
100
Germany,
Austria,
Switzerland
130
160
626
M10
Nrec [kN]
KSL 12
DIN 106/
EN 771-2
fb b) 12 N/mm
a)
b)
c)
d)
e)
M8
1 / 2009
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-IC c) / HIT-IG
M6
Setting
depth
[mm]
50
Hbl 2
DIN 18 151/
EN 771-3
fb b) 2 N/mm
80
100
Germany,
Austria,
Switzerland
130
160
Hbl 4
DIN 18 151/
EN 771-3
fb b) 4 N/mm
Germany,
Austria,
Switzerland
Hbn 4
DIN 18 153/
EN 771-3
fb b) 4 N/mm
a)
b)
c)
d)
e)
M8
M10
M12
M8
M10
M12
0,3
0,5
0,5
0,5
0,5
Vrec [kN]
0,3
0,5
0,5
0,5
0,5
Nrec [kN]
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
Vrec [kN]
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
Nrec [kN]
0,7
0,7
0,7
0,7
Vrec [kN]
0.6
0.6
0.6
0.6
Nrec [kN]
0.72
0.72
0,7
0,7
Vrec [kN]
0,6
0,6
0,6
0,6
Nrec [kN]
0,78
0,78
0,7
0,7
Vrec [kN]
0,6
0,6
0,6
0,6
Nrec [kN]
0,4
0,6
0,6
0,6
0,6
Vrec [kN]
0,4
0,6
0,6
0,6
0,6
Nrec [kN]
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
Vrec [kN]
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
Nrec [kN]
0,4
0,6
0,6
0,6
0,6
Vrec [kN]
0,4
0,6
0,6
0,6
0,6
Nrec [kN]
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
50
80
50
80
Germany,
Austria,
Vrec [kN]
0,8
0,8
0,8
0,8
0,8
0,8
0,8
Switzerland
Recommended load values for German base materials are based on national regulations.
fb = brick strength
HIT-IC elements are not covered by national German approval Z-21.3-1830 / 2006-11-14
HIT-SC 18x elements are not covered by national German approval Z-21.3-1830 / 2006-11-14
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
1 / 2009
0,8
627
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-IC c) / HIT-IG
M6
Setting
depth
[mm]
80
100
130
France
Parpaing creux
B40
NF-P 14-301/
EN 771-3
fb b) 4 N/mm
160
80
100
130
France
a)
b)
c)
d)
e)
628
160
M8
M10
M12
M8
M10
M12
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
Vrec [kN]
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
Nrec [kN]
0,5
0,5
0,5
0,5
Vrec [kN]
1,0
1,0
1,0
1,0
Nrec [kN]
0,5
0,5
0,5
0,5
Vrec [kN]
1,0
1,0
1,0
1,0
Nrec [kN]
0,5
0,5
0,5
0,5
Vrec [kN]
1,0
1,0
1,0
1,0
Nrec [kN]
0,7
0,7
0,7
0,7
0,7
0,7
0,7
0,7
Vrec [kN]
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
Nrec [kN]
0,7
0,7
0,7
0,7
Vrec [kN]
1,5
1,5
1,5
1,5
Nrec [kN]
0,7
1,2
1,2
1,2
Vrec [kN]
1,5
1,7
1,7
1,7
Nrec [kN]
0,7
1,2
1,2
1,2
Vrec [kN]
1,5
1,7
1,7
1,9
Recommended load values for French base materials are based on national regulations.
fb = brick strength
HIT-IC not covered by national French approval XY 0047 08.2006
HIT-SC 18x elements are not covered by national French approval XY 0047 08.2006
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
1 / 2009
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
M6
Setting
depth
[mm]
50
Mattone
Alveolater 50
EN 771-1
fb b) 16 N/mm
80
100
130
Italy
160
50
Doppio uni
EN 771-1
fb b) 27 N/mm
80
100
Italy
130
160
80
Foratino 4 Fori
EN 771-1
fb b) 7 N/mm
100
130
Italy
160
a)
b)
c)
M8
M10
M12
HIT-IC / HIT-IG
M8
M10
M12
0,9 (4,2)
1,1
1,1 (4,9)
1,25
1,25 (5,7)
Vrec [kN]
1,2 (5,8)
1,2
1,2
1,2
2,0 (10,2)
Nrec [kN]
1,1 (5,0)
1,5
1,5
1,7
1,7
1,5 (7,0)
1,7
1,7
1,7
Vrec [kN]
1,2 (5,3)
1,2
1,2
1,2
2,0
1,2
1,2
2,0
2,0
Nrec [kN]
1,5
1,5
1,7
1,7
Vrec [kN]
1,2
1,2
2,0
Nrec [kN]
2,3
2,8
2,8 (12,7)
Vrec [kN]
1,2
2,3
(10,4)
1,2
1,2
1,2
2,0
Nrec [kN]
2,3
2,3
2,8
2,8 (13,8)
Vrec [kN]
1,2
1,2
1,2
2,0
Nrec [kN]
0,65
(2,9)
0,65
0,65
0,65
0,65
(2,9)
Vrec [kN]
1,3 (5,7)
1,3
1,3 (6,6)
1,3
1,3 (6,0)
Nrec [kN]
1,0 (5,0)
1,0
1,0 (6,8)
1,0
1,0
1,0
1,0
1,0 (4,5)
Vrec [kN]
1,3 (6,1)
1,9
1,9 (8,5)
1,9
1,9
1,9
2,0
2,0
Nrec [kN]
1,0
1,0
1,0
1,0
2,0
(11,0)
1,0
Vrec [kN]
1,9
1,9
2,0
Nrec [kN]
2,0
2,0
2,0 (9,0)
Vrec [kN]
1,9
1,9
2,0
(12,1)
1,9
1,9
2,0
Nrec [kN]
2,0
2,0
2,0
2,0
Vrec [kN]
1,9
1,9
1,9
2,0
Nrec [kN]
0,6 (2,7)
Vrec [kN]
0,9
0,7
(3,3)
0,9
Nrec [kN]
0,7
0,7
1,0
1,0
Vrec [kN]
0,9
0,9
1,0
Nrec [kN]
1,5
1,9
1,9 (9,8)
Vrec [kN]
0,9
0,9
1,0
Nrec [kN]
1,5
1,5
1,9 (8,8)
Vrec [kN]
0,9
1,5
(6,7)
0,9
1,5
(7,3)
0,9
0,9
1,0
1,0
0,7
1,0
1,0
0,7
1,0
1,0
1,0 (5,2)
0,9
0,9
1,0
0,9
0,9
1,0
1,0
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
1 / 2009
629
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
Mattone rosso
EN 771-1
fb b) 26 N/mm
Italy
Blocchi cem 2
Fori
EN 771-3
fb b) 8 N/mm
M6
Setting
depth
[mm]
50
80
50
80
Italy
a)
b)
c)
M8
M10
M12
HIT-IC / HIT-IG
M8
M10
M12
0,35
(1,7)
0,45
0,45
(2,0)
0,45
0,45
Vrec [kN]
Nrec [kN]
0,5
(2,9)
0,5 (2,1)
0,5
(3,3)
0,6
0,6 (3,0)
0,5
Vrec [kN]
0,6
0,6 (4,2)
0,6
Nrec [kN]
1,25
1,25
1,25 (7,5)
Vrec [kN]
1,5 (7,2)
1,5
1,5
2,0 (14,6)
Nrec [kN]
1,25
1,25
1,25 (5,6)
1,25
1,25
1,25 (5,6)
1,25
Vrec [kN]
1,5 (7,1)
2,0
2,0
2,0 (20,0)
2,0
2,0
2,0
2,0
1,5
2,0
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC
HIT-AC, HIT-V, HAS, HAS-E or Rebar c)
Anchor size
Base
material
80
Volcanic rock
(Tufo)
EN 771-3
fb b) 4,3 N/mm
Italy
100
120
140
160
a)
b)
c)
d)
Rod M8
or
Rebar 8 d)
Rod M10
or
Rebar 10 d)
Rod M12
or
Rebar 12 d)
Rod M14
or
Rebar 14 d)
Rod M16
or
Rebar 16 d)
Nrec [kN]
0,9
Vrec [kN]
0,9
Nrec [kN]
1,2
Vrec [kN]
1,2
Nrec [kN]
1,5
Vrec [kN]
1,5
Nrec [kN]
1,8
Vrec [kN]
1,8
Nrec [kN]
2,1
Vrec [kN]
2,1
Setting
depth
[mm]
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
Minimum base material thickness h = setting depth + 50mm.
Drill bit diameters for rebars BSt 500S:
630
1 / 2009
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
M6
Setting
depth
[mm]
M10
M12
M8
M10
M12
0,5
(2,6)
0,5
(2,0)
0,5
(2,4)
0,5
0,5
Vrec [kN]
0,9
(4,2)
0,9
0,9
0,9
0,9
(4,4)
Nrec [kN]
0,7
(3,1)
0,9
(3,8)
0,9
(4,0)
1,1
1,1
(5,0)
0,9
(4,0)
1,1
1,1
(6,3)
1,1
Vrec [kN]
1,0
(4,8)
1,0
(4,5)
1,0
1,0
1,7
(7,8)
1,0
1,0
1,7
1,7
Nrec [kN]
0,5
(3,1)
0,7
0,7
0,7
0,7
(3,2)
Vrec [kN]
1,2
(5,5)
1,2
1,2
1,2
1,9
(8,6)
Nrec [kN]
0,5
(2,4)
1,1
(5,2)
1,1
1,3
1,3
1,1
1,3
1,3
(5,8)
1,3
Vrec [kN]
1,2
(5,6)
1,2
1,2
1,2
2,0
(10,8)
1,2
1,2
2,0
2,0
Nrec [kN]
0,8
(4,5)
0,8
(3,6)
0,8
0,8
0,8
Vrec [kN]
1,5
(6,9)
1,6
(8,6)
1,6
1,6
1,6
Nrec [kN]
0,8
1,9
1,9
2,3
2,3
1,9
(8,5)
2,3
2,3
2,3
(10,4)
Spain
Vrec [kN]
1,5
2,0
(12,4)
2,0
2,0
2,0
(17,4)
2,0
2,0
2,0
2,0
Clinker mediterraneo EN
771-1
fb b) 78 N/mm
Nrec [kN]
0,7
(3,3)
0,7
(3,1)
0,7
0,7
0,7
Vrec [kN]
1,5
(6,4)
1,6
(7,8)
1,6
1,6
1,6
(0,7)
Nrec [kN]
0,7
1,8
(8,0)
1,8
2,1
2,1
1,8
(8,3)
2,1
2,1
2,1
(9,7)
Vrec [kN]
1,4
(6,4)
2,0
(9,5)
2,0
2,0
2,0
(16,3)
2,0
(14,4)
2,0
2,0
2,0
Hueco doble
EN 771-1
fb b) 4 N/mm
Spain
Termoarcilla
EN 771-1
fb b) 22 N/mm
Spain
Ladrillo cara
vista
EN 771-1
fb b) 42 N/mm
50
80
50
80
50
80
50
80
Spain
a)
b)
c)
M8
HIT-IC / HIT-IG
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
1 / 2009
631
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
Concrete
Block
EN 771-3
fb b) 7,0 N/mm
L x H x B [mm]
440 x 215 x 215
(Shell thickness
48 mm)
Great Britain
Concrete
Block
EN 771-3
b)
fb 7 N/mm
L x H x B [mm]
440 x 215 x 138
(Shell thickness
48 mm)
Great Britain
Concrete
Block
EN 771-3
fb b) 7 N/mm
L x H x B [mm]
440 x 215 x 112
(Shell
thickness 48
mm)
Great Britain
a)
b)
c)
M6
Setting
depth
[mm]
M8
M10
M12
HIT-IC / HIT-IG
M8
M10
M12
0,3
0,8
1,1
2,0
2,0
Vrec [kN]
1,0
1,6
2,0
2,0
2,0
Nrec [kN]
0,3
0,8
1,1
2,0
2,0
Vrec [kN]
1,0
1,6
2,0
2,0
2,0
Nrec [kN]
0,4
0,6
0,7
1,5
1,5
Vrec [kN]
0,9
1,7
1,7
1,7
1,7
Nrec [kN]
0,4
0,6
0,7
1,5
1,5
Vrec [kN]
0,9
1,7
1,7
1,7
1,7
Nrec [kN]
0,5
0,8
0,9
0,9
0,9
Vrec [kN]
1,1
1,3
1,3
1,3
2,0
50
80
50
80
50
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
632
1 / 2009
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
Dense
Concrete
EN 771-3
fb b) 14 N/mm
L x H x B [mm]
440 x 215 x 100
M6
Setting
depth
[mm]
M8
M10
M12
HIT-IC / HIT-IG
M8
M10
M12
Nrec [kN]
1,5
2,5
2,5
2,5
2,5
Vrec [kN]
1,3
2,5
2,5
2,5
3,0
Nrec [kN]
1,5
2,5
2,5
2,5
2,5
Vrec [kN]
1,3
2,5
2,5
2,5
3,0
Nrec [kN]
1,5
3,0
3,0
3,0
4,0
3,0
3,0
3,0
4,0
Great Britain
Vrec [kN]
1,3
2,5
2,5
2,5
3,0
2,5
2,5
3,0
3,0
Thermalite/
Celcon
EN 771-3
fb b) 6 N/mm
L x H x B [mm]
440 x 100 x 215
Nrec [kN]
0,7
0,8
0,8
0,8
0,8
Vrec [kN]
0,5
0,6
0,6
0,6
0,9
Nrec [kN]
1,3
1,5
1,5
1,7
1,7
1,5
1,7
1,7
1,7
Vrec [kN]
0,9
1,0
1,0
1,0
1,2
1,0
1,0
1,2
1,2
Nrec [kN]
1,0
2,0
2,0
2,0
2,5
Vrec [kN]
1,5
3,0
3,0
3,0
3,0
Nrec [kN]
1,0
3,0
3,0
3,0
3,5
3,0
3,5
3,5
3,5
Vrec [kN]
1,5
3,0
3,0
3,0
3,0
3,0
3,0
3,0
3,0
50
Great Britain
Dense
Concrete
EN 771-3
b)
fb 14 N/mm
L x H x B [mm]
440 x 215 x 140
50
80
50
80
Great Britain
Nostell Red
Multi
EN 771-3
fb b) 70 N/mm
L x H x B [mm]
215 x 102 x 65
50
80
Great Britain
a)
b)
c)
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
1 / 2009
633
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
M6
Setting
depth
[mm]
Base
material
London yellow
Multi Stock
EN 771-3
fb b) 16 N/mm
L x H x B [mm]
215 x 100 x 65
M8
M10
M12
HIT-IC / HIT-IG
M8
M10
M12
1,0
1,3
1,3
1,7
1,7
Vrec [kN]
1,4
1,9
1,9
1,9
2,5
Nrec [kN]
2,0
3,0
3,0
3,0
4,0
3,0
3,0
3,0
4,0
Vrec [kN]
1,4
2,5
2,5
2,5
3,0
2,5
2,5
3,0
3,0
50
80
Great Britain
a)
b)
c)
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
Recommended loads a) Frec for brick breakout and/or pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-AC, HIT-V, HAS, HAS-E
HIT-IG / HIT-IC
Anchor size
Base
material
Dense
Concrete
EN 771-3
fb b) 14 N/mm
L x H x B [mm]
440 x 215 x 100
Great Britain
Dense
Concrete
EN 771-3
fb b) 14 N/mm
L x H x B [mm]
440 x 215 x 140
Setting Base
depth material
[mm]
M6
M8
M10
M12
M8
M10
M12
Nrec [kN]
2,5
2,5
2,5
Vrec [kN]
2,5
2,5
3,0
3,5 c)
4,0 c)
4,5 c)
2,5
2,5
3,0
80
Nrec [kN]
80
Vrec [kN]
Great Britain
a)
b)
c)
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb brick strength
The minimum value of brick break out and/or pull out given in the table and of pull out of one brick is decisive.
634
1 / 2009
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
Fire light brick
Scoria Blend
fb b) 16 N/mm
L x H x B [mm]
230 x 110 x 119
(Shell thickness
19 mm)
Australia
Hollow Block
fb b) 15 N/mm
L x H x B [mm]
390 x 190 x 190
(Shell thickness
30 mm)
Australia
Clay common
(Standard)
fb b) 84 N/mm
L x H x B [mm]
230 x 110 x 76
(Shell thickness
20 mm)
Australia
a)
b)
c)
M6
Setting
depth
[mm]
M8
M10
M12
HIT-IC / HIT-IG
M8
M10
M12
0,5
0,5
0,5
0,8
0,8
Vrec [kN]
1,0
1,5
1,5
1,5
2,0
Nrec [kN]
1,8
1,8
1,8
1,8
1,8
1,8
1,8
1,8
1,8
Vrec [kN]
1,25
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
Nrec [kN]
0,6
0,6
0,6
0,6
0,6
Vrec [kN]
1,0
1,5
1,5
1,5
2,0
Nrec [kN]
0,6
0,9
0,9
1,7
1,7
0,9
1,7
1,7
1,7
Vrec [kN]
1,25
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
Nrec [kN]
1,5
1,5
1,5
1,5
1,5
Vrec [kN]
2,0
2,0
2,0
2,0
2,0
Nrec [kN]
2,0
3,0
3,0
3,0
4,0
3,0
4,0
4,0
4,0
Vrec [kN]
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
50
80
50
80
50
80
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
1 / 2009
635
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC
HIT-AC, HIT-V, HAS, HAS-E
HIT-IG / HIT-IC
Anchor size
Base
material
Clay common
(Dry pressed)
fb b) 25 N/mm
L x H x B [mm]
230 x 110 x 76
Setting
depth
[mm]
M8
M10
M12
M8
M10
M12
Nrec [kN]
2,5
3,0
4,0
2,5
3,0
4,0
Vrec [kN]
2,0
2,0
2,0
2,0
2,0
2,0
Nrec [kN]
2,5 c)
3,0 c)
3,0 c)
3,0 c)
4,0 c)
Vrec [kN]
3,0
4,0
3,0
3,0
4,0
Nrec [kN]
2,5 c)
3,0 c)
3,0 c)
3,0 c)
4,0 c)
Vrec [kN]
3,0
4,0
3,0
3,0
4,0
80
Australia
Calduran
Solid sand-lime
brick
fb b) 22 N/mm
L x H x B [mm]
437x198x100
M6
80
Netherlands
Calduran
Solid sand-lime
brick
fb b) 22 N/mm
L x H x B [mm]
437x298x215
80
Netherlands
a)
b)
c)
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
The minimum value of brick break out and/or pull out given in the table and of pull out of one brick is decisive.
636
1 / 2009
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
Wienerberger
Powerbrick
fb b) 41 N/mm
L x H x B [mm]
285x135x135
M6
Setting
depth
[mm]
M8
M10
M12
HIT-IC / HIT-IG
M8
M10
M12
1,0
1,25
1,25
1,25
1,25
Vrec [kN]
1,5
2,0
2,0
2,0
3,0
Nrec [kN]
1,5
1,75
1,75
2,0
2,0
1,75
2,0
2,0
2,0
Vrec [kN]
1,5
3,0
3,0
3,0
4,0
3,0
3,0
4,0
4,0
Nrec [kN]
0,5
0,75
0,75
1,0
1,0
Vrec [kN]
1,0
1,25
1,25
1,25
1,5
Nrec [kN]
1,5
1,75
1,75
1,75
1,75
1,75
1,75
1,75
1,75
Belgium
Vrec [kN]
1,5
2,0
2,0
2,0
2,5
2,0
2,0
2,5
2,5
Concrete
hollow brick
fb b) 6 N/mm
L x H x B [mm]
600x500x92
Nrec [kN]
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
0,5
Vrec [kN]
0,5
0,75
0,75
0,75
1,0
0,75
0,75
1,0
1,0
Nrec [kN]
2,0
2,0
2,0
2,0
2,0
2,0
2,0
2,0
Vrec [kN]
1,2
1,2
1,2
2,0
1,2
1,2
2,0
2,0
50
80
Belgium
Wienerberger
Thermobrick
fb b) 21 N/mm
L x H x B [mm]
285x135x138
50
80
50
(Shell thickness
15 mm) Finland
Leca typ 3
EN 771-3
fb 3,0 N/mm
80
Sweden
a)
b)
c)
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
1 / 2009
637
Hilti HIT-HY 70
Recommended loads Frec for brick breakout and pull out in [kN]:
Hollow masonry: HIT-HY 70 with HIT-SC and HIT-AC/HIT-V, HAS, HAS-E and HIT-IG/HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-AC, HIT-V, HAS, HAS-E
Anchor size
Base
material
Concrete
block
fb b) 23 N/mm
L x H x B [mm]
390 x 190 x 120
(Shell thickness
25 mm)
Japan
Spancrete
(Hollow Core
Slab)
fb b) 83 N/mm
L x H x B [mm]
1000 x1000 x125
M6
Setting
depth
[mm]
M10
M12
M8
M10
M12
1,25
(8,1)
1,5
1,5
2,0
2,0
(10,9)
Vrec [kN]
1,25
(6,7)
1,5
(11,4)
1,5
1,5
2,0
(17,2)
Nrec [kN]
1,25
(9,0)
1,5
(10,3)
1,5
2,0
2,0
1,5
(9,2)
2,0
2,0
2,0
(12,1)
Vrec [kN]
1,25
(7,1)
1,5
1,5
1,5
2,0
1,5
(11,4)
1,5
2,0
2,0
(15,9)
Nrec [kN]
1,25
(8,5)
2,0
(15,0)
2,0
2,5
2,5
(23,7)
2,5
(13,9)
2,5
2,5
(19,3)
Vrec [kN]
1,25
(7,0)
2,5
(12,0)
2,5
2,5
3,0
(24,3)
2,5
(21,3)
2,5
3,0
(28,1)
Nrec [kN]
1,25
(8,1)
1,75
(8,6)
1,75
2,0
2,0
(9,9)
Vrec [kN]
0,75
(6,3)
1,00
(9,2)
1,00
1,00
1,25
(12,8)
50
80
50
(Shell thickness
27,5 mm)
Japan
Aereted
concrete block
fb b) 6 N/mm
L x H x B [mm]
1900 x 600 x 100
Special application:
through fastening
HIT-SC HIT-SC
x50
x85
M8
HIT-IC / HIT-IG
130
100
Japan
a)
b)
c)
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb = brick strength
HIT-SC 18x with HIT-IC M10 only! HIT-IG M10 elements do not fit.
638
1 / 2009
Hilti HIT-HY 70
Recommended loads a) Frec for brick breakout and pull out in [kN]
Solid masonry: HIT-HY 70 with HIT-AC / HIT-V, HAS, HAS-E and HIT-IG / HIT-IC
Values in brackets: mean ultimate loads Fu,m [kN]:
HIT-AC, HIT-V, HAS, HAS-E
HIT-G / HIT-IC
Anchor size
Base
material
Aereted
concrete
block
fb b) 6 N/mm
LxHxB
[mm]
1900 x 600 x 100
Setting
depth
[mm]
M6
M8
M10
M12
M8
M10
M12
Nrec [kN]
0,75
0,75
(4,0)
Vrec [kN]
1,0
1,0
(8,6)
Nrec [kN]
1,5
(7,3)
1,75
1,75
(7,4)
1,75
(8,0)
Vrec [kN]
0,75
(4,2)
1,0
(4,7)
1,0
(4,6)
1,0
(5,8)
50
80
Japan
a)
b)
Recommended load values with consideration of a global safety factor global =3,0: Frec = FRk / global
fb brick strength
1 / 2009
639
Hilti HIT-HY 70
Design
Influence of joints:
If the joints of the masonry are not visible the recommended load Nrec has to be reduced with the factor j = 0.75.
If the joints of the masonry are visible (e.g. unplastered wall) following has to be taken into account:
The recommended load Nrec may be used only, if the wall is designed such that the joints are to be
filled with mortar.
If the wall is designed such that the joints are not to be filled with mortar then the recommended load
Nrec may be used only, if the minimum edge distance cmin to the vertical joints is observed. If this
minimum edge distance cmin can not be observed then the recommended load Nrec has to be reduced
with the factor j = 0.75.
The decisive resistance to tension loads is the lower value of Nrec (brick breakout, pull out) and Nmax,pb (pull
out of one brick).
Pull out of one brick:
The allowable load of an anchor or a group of anchors in case of pull out of one brick, Nmax,pb [kN], is given in the
following tables:
Clay bricks:
Nmax,pb
brick
length
lbrick
[mm]
Nmax,pb
80
120
200
240
300
360
240
1,1
1,6
2,7
3,3
4,1
4,9
300
1,4
2,1
3,4
4,1
5,1
6,2
500
2,3
3,4
5,7
6,9
8,6
10,3
[kN]
80
120
200
240
300
360
240
0,8
1,2
2,1
2,5
3,1
3,7
300
1,0
1,5
2,6
3,1
3,9
4,6
500
1,7
2,6
4,3
5,1
6,4
7,7
[kN]
brick
length
lbrick
[mm]
lbrick
bbrick
Nmax,pb
For all applications outside of the above mentioned base materials and / or setting conditions
site tests have to be made for the determination of load values.
Due to the wide variety of natural stones site tests have to be made for determine of load values.
640
1 / 2009
Hilti HIT-HY 70
Materials
Material quality HAS
Part
Threaded rod
HAS-(E)
Threaded rod
HAS-(E)R
Washer
ISO 7089
Nut
EN ISO 4032
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
Stainless steel grade A4, A5 > 8% ductile strength class 70,EN ISO 35061, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Steel galvanized, EN ISO 4042;
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439;
1.4362
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
Material
Carbon steel grade 5.8; galvanized to min. 5 m
Stainless steel, grade A4-70; 1.4401; 1.4404; 1.4571
Carbon steel grade 3.6; galvanized to min. 5 m
Material
Carbon steel 1.0718; galvanized to min. 5 m
Carbon steel; galvanized to min. 5 m
PA/PP
Setting
Installation equipment
Anchor size
Rotary hammer
Other tools
1 / 2009
M6
M8
M10
M12
TE2 TE16
blow out pump, set of cleaning brushes, dispenser
641
Hilti HIT-HY 70
642
1 / 2009
Hilti HIT-HY 70
Setting details: hole depth h0 and effective anchorage depth in solid base materials
HIT-AC, HIT-V
M10
M12
M8
d0
[mm]
10
12
14
10
12
14
18
hef
[mm]
80
80
80
80
90
110
125
h0
[mm]
85
85
85
85
95
115
130
hmin
[mm]
115
115
115
110
120
140
170
df
[mm]
12
14
12
14
18
smin
[mm]
100
100
100
100
100
100
100
cmin
[mm]
100
100
100
100
100
100
100
Tinst
[Nm]
[ml]
5
4
8
5
10
7
5
4
8
6
10
10
10
15
1 / 2009
643
Hilti HIT-HY 70
HIT-IG, HIT-IC
HIS-N/RN
M8
HIT-IG
M10
M12
M8
HIT-IC
M10
M12
HIS-N/RN
M8
M10
M12
d0
[mm]
14
18
18
14
16
18
14
18
22
hef
[mm]
80
80
80
80
80
80
90
110
125
h0
[mm]
85
85
85
85
85
85
95
115
130
hmin
[mm]
115
115
115
115
115
115
120
150
170
df
[mm]
12
14
12
14
12
14
hS
[mm]
min. 10 max. 75
smin
[mm]
100
100
100
100
100
100
cmin
[mm]
100
100
100
100
100
100
100
100
100
Tinst
[Nm]
[ml]
5
6
8
6
10
6
5
6
8
6
10
6
5
6
8
10
10
16
min. 10 max. 75
644
1 / 2009
Hilti HIT-HY 70
1 / 2009
645
Hilti HIT-HY 70
Setting details: hole depth h0 and effective anchorage depth in hollow base materials
HAS / HIT-AC with HIT-SC
d0
[mm]
12
12
16
16
16
16
18
18
22
22
hef
[mm]
50
80
50
80
50
80
50
80
50
80
Hole depth
h0
[mm]
60
95
60
95
60
95
60
95
60
95
hmin
[mm]
80
115
80
115
80
115
80
115
80
115
df
[mm]
12
12
14
14
14
14
smin
[mm]
100
100
100
100
100
100
100
100
100
100
cmin
[mm]
100
100
100
100
100
100
100
100
100
100
Tinst
[Nm]
[ml]
3
12
3
24
3
18
3
30
4
18
4
30
6
18
6
36
6
30
6
55
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Minimum spacing a)
Minimum edge
distance a)
Torque moment
Filling volume
646
M6
M8
M10
M12
12x50 12x85 16x50 16x85 16x50 16x85 18x50 18x85 22x50 22x85
1 / 2009
Hilti HIT-HY 70
Setting details: hole depth h0 and effective anchorage depth in hollow base materials
HIT-IG / HIT-IC
M8
16x85
HIT-IG
M10
22x85
M12
22x85
M8
16x85
HIT-IC
M10
18x85
M12
22x85
d0
[mm]
16
22
22
16
18
22
hef
[mm]
80
80
80
80
80
80
h0
[mm]
95
95
95
95
95
95
Minimum base
hmin
[mm]
115
115
115
115
115
115
material thickness
Diameter of clearance
df
[mm]
9
12
14
9
12
14
hole in the fixture
Length of bolt
hS
[mm]
min. 10 max. 75
min. 10 max. 75
engagement
Minimum spacing a)
smin
[mm]
100
100
100
100
100
100
Minimum edge
cmin
[mm]
100
100
100
100
100
100
distance a)
Torque moment
Tinst
[Nm]
3
4
6
3
4
6
Filling volume
[ml]
30
45
45
30
36
45
a) In case of shear loads towards a free edge: cmin = 20 cm
A distance from the edge of a broken brick of cmin = 20 cm is recommended, e.g. around window or door frames.
1 / 2009
647
648
1 / 2009
1 / 2009
649
Applications
design flexibility
form work
simplification
defined load
characteristics
Diaphragm walls
Misplaced bars
650
Slab connections
Vertical/horizontal connections
1 / 2009
Wall strenghtening
Joint strenghtening
Cantilevers/balconies
Slab widening
Structural upgrade
Slab strenghtening
Side-walk upgrade
1 / 2009
651
Rebar basics
In the course of the Anchor FTM the focus will be on the last two types of applications.
Chapter 3, Adhesive Anchoring Systems, deals with rebar as an anchor. The current chapter
focuses on rebar as structural rebar, where the reinforcement is purely loaded in the longitudinal
direction.
lv
l0
lbd
/3 lbd
10 ds
Structural rebar is characterized by very high loads. The reinforcement is often loaded up to
steel yielding. The concrete structure (connection) shows a good serviceability. The
deformations are small and due to this the crack width and therefore the influences by the
environment (corrosion) are limited. The concrete connections behave as a monolithic structure
or in other words as if the concrete was poured in one go. The high loads which can occur in
either the anchorage or the splice can lead to an embedment length up to 15 till 80 times the
diameter of the reinforcement.
The design can be done according to two design concepts;
652
1 / 2009
653
2.4
Figure 2.3.b
Figure 2.4.2.a
S litti
Figure 2.4.2.b
1 / 2009
of the adhesive mortar against the concentrated load near the ribs and on the capacity of load
transfer at the interface of the drilled hole.
In many cases the bond values of post-installed bars are higher compared to cast in bars due to
better performance of the adhesive mortar. But for small edge distance and/or narrow spacing
splitting or spalling forces become decisive due to the low tensile capacity of the concrete.
Design basics
1 / 2009
655
To prevent damage of the concrete during drilling the following requirements have to be
met:
cmin = 30 + 0,06lv 2ds (mm) for hammer drilled holes, with ds being the
diameter of the rebar
cmin = 50 + 0,08lv 2ds (mm) for compressed air drilled holes
The factors 0,06 and 0,08 take into account the possible deviations during the drilling
process. This value might be smaller if special drilling aid devices are used.
The transfer of shear forces between new and old concrete shall be designed according to EC2.
See also paragraph 3.4 strut-and-tie model.
The reader is referred to the paragraph 4 EC2 Design for more detail about this design
concept.
656
1 / 2009
8.0
7.0
6.9 N/mm2
6.0
fbd
5.0
4.0
3.3 N/mm2
3.0
cd = min(a/2, c, c1)
2.0
1.0
0.0
0
10
20
30
c d,min
C20/25, = 12 mm
40
50
60
cd
70
80
90 100 110
ACI 318-08 approach
EC2/ETA approach
Figure 3.3: equivalent design bond stress fbd as a function of cd., derived from reduction of anchoring lenght
according to ACI 318-08 and EC2/ETA.
1 / 2009
657
f bd =
f ck
with: Atr
c + K tr
4 ;
K tr =
A tr f yt
10.34 s n
c + K tr
2.5 for cast - in bars
total cross-sectional area of all transverse reinforcement that is within the spacing
s and that crosses the potential plane of splitting through the reinforcement being
developed [mm2]
fyt
b,
f bd =
for
c + K tr
2.5 (post-installed reinforcement and cast-in reinforcement):
f ck c + K tr
c + K tr
> 2.5 (bonded-in bars only):
f ck
c + K tr
2.5 + 0.75
2.5
4
where:
fbd
design bond strength
For more detailed Information see: Kunz, J.; Mnger, F.: Splitting- and bond failure of post-installed rebar splices
and anchoring.; Bond in Concrete from research to standards, Proceedings of the 3rd International Symposium
held at the Budapest University of Technology and Economics, Budapest, Hungary, 20 to 22 November 2002,
p.447 -454. (Copy available from Hilti Technical Service)
658
1 / 2009
Crack limitation
Joint to be
roughened
Tension cord
Tension ties
A strut-and-tie model is used to calculate the load path in reinforced concrete members. Where
a non-linear strain distribution exists (e.g. supports) strut-and-tie models may be used {Clause
6.5.1(1), EC2: EN 1992-1-1:2004}.
Strut-and-tie models consist of struts representing compressive stress fields, of ties
representing the reinforcement and of the connecting nodes. The forces in the elements of a
strut-and-tie model should be determined by maintaining the equilibrium with the applied loads
in ultimate limit state. The ties of a strut-and-tie model should coincide in position and direction
with the corresponding reinforcement {Clause 5.6.4, EC2: EN 1992-1-1:2004 Analysis with strut
and tie models}.
1 / 2009
659
Figure 3.6.a:
Support, truss
Figure 3.6.b:
Tensile force has ended
Figure 3.6.c:
Compression
EC2 design
4.1 General
The actual position of the reinforcement in the existing structure shall be determined on the basis of the
construction documentation and taken into account when designing. The transfer of shear forces between new
concrete and existing structure shall be designed according to EC2 EN 1992-1-1:2004. See also paragraph 3.4
Strut-and-tie model The joints for concreting must be roughened to at least such an extent that aggregate
protrude. See also paragraph 3.5 Joint to be roughened.
The design of post-installed rebar connections and determination of the internal section forces to be transferred in
the construction joint shall be verified in accordance with EC2 EN 1992-1-1:2004. When ascertaining the tensile
force in the rebar, allowance shall be made for the statically effective height of the bonded-in reinforcement. See
also paragraph 5.2 Example with overlap joint
660
1 / 2009
with:
ds
sd
fbd
1 is for the effect of the form of the bars assuming adequate cover
(post-installed reinforcement is always straight)
2 is for the effect of concrete minimum cover
2 = 1 0,15 (c d d 0 )/d 0
straight bars; c d = min (a/2 ; c 1 ; c )
With no edge distance, 2 = 0,7 if the spacing given in the table below are fulfilled:
ds (mm)
Spacing (mm)
a (mm)
8
56
48
10
70
60
12
84
72
14
98
84
16
112
96
18
126
108
20
140
120
22
154
132
24
168
144
25
175
150
26
182
156
28
196
168
30
210
180
32
224
192
34
238
204
36
252
216
40
280
240
1 / 2009
661
lb,min
Influencing factor
Type of anchorage
Shape of bars
Concrete cover
Straight
Straight
Confinement by
transverse
reinforcement
Confinement by
welded transverse
reinforcement
Confinement by
transverse pressure
Straight
where:
Ast
Ast,min
As
K
p
Straight
Straight
Reinforcement bar
In tension
In compression
1 = 1.0
1 = 1.0
2 = 1.0
2 = 1 0.15(cd
)/
0.7
1.0
3 = 1.0
3 = 1 K
0.7
1.0
4 = 1.0
4 = 1.0
5 = 1 0.04p
0.7
1.0
= (Ast - Ast,min)/ As
cross-sectional area of the transverse reinforcement along the design anchorage length lbd
cross-sectional area of the minimum transverse reinforcement = 0.25 As for beams and 0 for slabs
area of a single anchored bar with maximum bar diameter
values shown in Figure 4.10
transverse pressure [MPa] at ultimate limit state along lbd
662
1 / 2009
Laps between bars should not be located in areas of high moments / forces (e.g. plastic hinges) and at any section
normally be arranged symmetrically. The arrangement of lapped bars should comply with Figure 4.4. The clear
distance between lapped bars should be 4 and 50 mm, otherwise the lap length should be increased by a
length equal to the clear space where it exceeds 4 or 50 mm.
< 25%
33%
50%
> 50%
1,15
1,4
1,5
1 / 2009
663
664
1 / 2009
Design examples
d = 260
a1 = 130
h = 300
al = 260
ln = 6,50 m
1 / 2009
665
lb,min
Due to large edge distances in all directions (confined concrete) the failure mode splitting of
concrete is not becoming decisive, but the pull out failure mode: fbd = 6.9 N/mm2
FRd = n(lbd x x x fbd) = 5(lbd x 12 x x 6.9) = 214.8 kN/m
lbd = 165 mm
lb,min = 120 mm (10 x ) ok
Fire resistance:
Fire rating class F 90 (90 min.) (design table see paragraph 4.7):
FsT,req = 0,6 x 66,1 = 39,7 kN/m = 7,9 kN/bar
1 / 2009
Intermediate values may be interpolated linearly: linst = 16,5 cm; Fs,T = 11,2 kN/bar > 7,9 kN/bar
linst = 165 mm
Top reinforcement
300
a1 = 130
h = 300
Minimum reinforcement:
25% of bottom steel required at mid-span
{Clause 9.3.1.2(2), EC2: EN 1992-1-1:2004}
As,req = 0,25 x 988 = 247 mm2/m
2
As,min = 0,4 x 1 x 2,2 x 150 x 1000 / 500 = 264 mm /m
{Clause 7.3.2(2), EC2: EN 1992-1-1:2004}
al = 260
ln = 6.50 m
1 / 2009
667
fbd = 6,9 N/mm2 FRd = n(lbd x x x fbd) = 3,33(lbd x 12 x x 6,9) = 114,8 kN/m (if hef < 18)
lbd = 132 mm
lb,min = 120 mm (10 x ) ok
Concrete (shear):
30
cs = 50
d = 250
h = 300
10
fbd = design value of bond strength according to corresponding ETA = 2,7 N/mm2
668
1 / 2009
Cast-in reinforcement
l0 = 1 2 3 5 6 lb,rqd l0,min
with: lb,rqd the basic anchorage length, lb,rqd = (ds / 4) x (sd / fbd)
ds = diameter of the rebar = 16 mm
sd = calculated design stress of the rebar
fbd = design value of bond strength according to corresponding ETA = 2,7 N/mm2
lv l0 + c1
with: l0 = required lap length = 770 mm (see above)
lv = 800 mm
If the clear distance between the overlapping rebars is greater than 4ds (4 x 16 = 64 mm) the lap length shall be
enlarged by the difference between the clear distance and 4ds.
Most unfavorable case post-installed rebar is located right in the middle between the cast-in rebars. The clear
distance between the overlap is: s22 = (75 8)2 + (20 8)2 = 4633 s2 = 68 mm
68 64 = 4 mm 5 mm
lv = 800 + 5 = 805 mm
1 / 2009
669
f bd =
c + K tr
2.5
f c' 2.5 + 0.75
according
Due to edge distances (c = 50 mm) and spacing (s = 150 mm) the failure mode splitting of
concrete is decisive.
6 = 1,5 fbd = 3,1 N/mm2
FRd = n(l0 x x x fbd) = 6.66(
l0 = 514 mm
Cast-in reinforcement
(as above)
lv = 805 mm
Fire resistance:
Fire rating class F 60 (60 minutes) (design table see paragraph 4.7):
Clear concrete cover including light weight plaster: c = 4 + 3 = 7 cm
670
1 / 2009
6 Corrosion behavior
The Swiss Association for Protection against Corrosion (SGK) was given the assignment of evaluating the
corrosion behavior of fastenings post-installed in concrete using the Hilti HIT-HY 150, Hilti HIT-HY 150 MAX and
Hilti HIT-RE 500 injection systems.
Corrosion tests were carried out. The behavior of the two systems had to be evaluated in relation to their use in
field practice and compared with the behavior of cast-in reinforcement. The SGK can look back on extensive
experience in this field, especially on expertise in the field of repair and maintenance work.
The result can be summarized as follows:
Hilti HIT-HY 150 + Hilti HIT-HY 150 MAX
The Hilti HIT-HY 150 and Hilti HIT-HY 150 MAX systems in combination with reinforcing bars can be
considered resistant to corrosion when they are used in sound, alkaline concrete. The alkalinity of the
adhesive mortar safeguards the initial passivation of the steel. Owing to the porosity of the adhesive mortar,
an exchange takes place with the alkaline pore solution of the concrete.
If rebars are bonded-in into chloride-free concrete using this system, in the event of later chloride exposure,
the rates of corrosion are about half those of rebars that are cast-in.
In concrete containing chlorides, the corrosion behavior of the system corresponds to that of cast-in rebars.
Consequently, the use of unprotected steel in concrete exposed to chlorides in the past or possibly in the
future is not recommended because corrosion must be expected after only short exposure times.
If the Hilti HIT-RE 500 system is used in corrosive surroundings, a sufficiently thick coat of adhesive
significantly increases the time before corrosion starts to attack the bonded-in steel.
The HIT-RE 500 system may be described as resistant to corrosion, even in concrete that is carbonated and
contains chlorides, if a coat thickness of at least 1 mm can be ensured. In this case, the unprotected steel in
the concrete joint and in the new concrete is critical.
If the coat thickness is not ensured, the HIT-RE 500 system may be used only in sound concrete. A rebar may
then also be in contact with the wall of the drilled hole. At these points, the steel behaves as though it has a
thin coating of epoxy resin.
In none of the cases investigated did previously rusted steel (without chlorides) show signs of an attack by
corrosion, even in concrete containing chlorides.
Neither during this study an acceleration of corrosion was found at defective points in the adhesive nor was
there any reference to this in literature. Even if a macro-element forms, the high resistance to it spreading
inhibits a locally increased rate of corrosion.
Information in reference data corresponds with the results of this study.
7 Fire design
If passive fire prevention requirements have to be met, the suitability of rebar connections should be verified
additionally to ULS cold design.
Large-area building components (walls and floors) can be verified according to tables 1 and 2. The design tables
are derived from tests at the University / IBMB Braunschweig following the Standard ISO 834 temperature/time
curve. Design for fire resistance is carried out in line with several specific standards. On the following pages only
the fire data for Standard according EC2 are given.
Details to all available Standards and specific reports are named below the following tables.
Note for the following tables 1 to 6: Fs,T = force in bar when exposed to fire.
Intermediate values may be interpolated linearly. Extrapolating is not permitted.
1 / 2009
671
linst
Table 1: Maximum force in rebar in conjuction with HIT-HY 150 as a function of embedment depth for the
fire resistance classes F30 to F180 (yield strength fyk = 500 N/mm) according EC2 a)
Bar
Drill
hole
[mm]
[mm]
10
10
12
14
16
20
672
12
16
F30
F60
linst
[mm]
120
140
150
FS,T
[kN]
10,6
14,1
15,6
linst
[mm]
120
140
160
180
190
FS,T
[kN]
5,0
8,4
11,9
15,4
15,6
150
160
180
19,8
22,0
24,3
150
160
180
200
210
12,7
14,9
19,3
23,7
24,3
180
200
31,7
35,1
180
200
220
230
23,1
28,4
33,7
35,1
210
220
46,2
47,7
210
220
240
250
36,2
39,3
45,4
47,7
240
62,3
240
260
270
300
97,4
300
320
18
20
25
F90
F120
linst
[mm]
120
140
160
180
200
210
150
160
180
200
220
230
180
200
220
240
250
210
220
240
260
270
FS,T
[kN]
2,8
4,5
7,9
11,4
14,9
15,6
1,7
9,9
14,3
18,7
23,1
24,3
17,1
22,4
27,7
32,9
35,1
29,2
32,2
38,4
44,6
47,7
51,9
59,0
62,3
240
260
280
300
43,9
51,0
58,0
62,3
91,3
97,4
300
320
340
81,3
90,1
97,4
linst
[mm]
120
140
160
180
200
220
150
160
180
200
220
250
180
200
220
240
270
210
220
240
260
280
290
240
260
280
300
310
300
320
340
360
FS,T
[kN]
1,9
3,3
5,2
8,6
12,1
15,6
5,1
6,5
10,7
15,1
19,5
24,3
12,9
18,1
23,4
28,7
35,1
24,2
27,3
33,5
39,6
45,8
47,7
38,3
45,3
52,3
59,4
62,3
74,3
83,0
91,8
97,4
F180
linst
[mm]
120
140
160
200
240
280
150
160
180
220
260
300
180
200
240
280
320
210
220
240
280
320
350
240
280
320
360
370
300
320
360
400
410
FS,T
[kN]
0,7
1,5
2,7
5,3
9,6
15,6
2,6
3,3
4,9
8,5
16,4
24,3
5,9
8,0
14.,4
24,9
35,1
10,6
11,9
16,8
29,1
41,4
47,7
19,2
33,2
47,3
61,4
62,3
50,3
59,1
76,7
94,3
97,4
1 / 2009
Bar
Drill
hole
[mm]
[mm]
25
32
F30
linst
[mm]
375
FS,T
[kN]
152,2
F60
linst
[mm]
375
FS,T
[kN]
152,2
F90
linst
[mm]
375
380
400
F120
FS,T
[kN]
142,9
145,6
152,2
linst
[mm]
375
380
400
410
FS,T
[kN]
134,0
136,7
147,7
152,2
F180
linst
[mm]
375
380
400
440
470
FS,T
[kN]
104,1
106,9
117,9
139,9
152,2
Max. bond stress, T , depending on actual clear concrete cover for classifying the fire
resistance.
It must be verified that the actual force in the bar during a fire, Fs,T , can be taken up by the bar
connection of the selected length, linst. Note: Cold design for ULS is mandatory.
Fs, T (linst cf) T where: (linst cf) ls;
= lap length
ls
cf
Table 2: Critical temperature-dependent bond stress, crit,T, concerning overlap joint for Hilti-HIT-HY 150
injection adhesive in relation to fire resistance class and required minimum concrete coverage c.
Clear concrete cover c
Max. bond stress, T [N/mm]
[mm]
F30
F60
F90
F120
F180
20
0,7
0
0
30
1,4
0,2
0
40
1,9
0,7
0
50
2,4
1,2
0,4
60
2,8
1,7
0,7
0,3
70
4,9
2,2
1,2
0,7
1 / 2009
673
F30
7,0
F180
0,2
0,5
0,7
1,2
1,6
1,9
2,2
2,3
2,5
2,6
2,7
2,8
2,9
3,0
4,5
6,5
7,0
linst
Table 3: Maximum force in rebar in conjuction with HIT-HY 150 MAX as a function of embedment
the fire resistance classes F30 to F180 (yield strength fyk = 500 N/mm) according EC2a).
Max. Fs,T
F30
F60
F90
F120
Bar
Drill hole
linst
[mm]
[mm]
[kN]
[mm]
[kN]
[kN]
[kN]
[kN]
80
2,18
0,73
0,24
0,05
120
8,21
2,90
1,44
0,82
170
16,2
9,95
5,99
3,69
8
12
16,2
210
16,2
13,01
9,52
230
16,2
13,04
250
16,2
300
100
5,87
1,95
0,84
0,4
150
16,86
8,06
4,45
2,82
190
25,3
16,83
11,86
7,65
10
14
25,3
230
25,3
20,66
16,29
260
25,3
22,89
280
25,3
320
674
depth for
F180
[kN]
0
0,18
1,35
3,6
5,74
9,26
16,2
0
0,96
2,91
7,18
13,77
18,17
25,3
1 / 2009
Bar
[mm]
Drill hole
[mm]
Max. Fs,T
[kN]
12
16
36,4
14
16
20
25
18
20
25
32
49,6
64,8
101,2
158,1
linst
[mm]
120
180
220
260
280
300
340
140
210
240
280
300
330
360
160
240
260
300
330
360
400
200
250
310
350
370
390
430
250
280
370
410
430
450
500
F30
[kN]
12,32
28,15
36,4
F60
[kN]
4,35
17,56
28,12
36,4
F90
[kN]
2,16
11,59
22,15
32,7
36,4
F120
[kN]
1,23
7,14
16,91
27,47
32,75
36,4
20,53
42,08
49,6
8,77
29,72
38,96
49,6
4,74
22,76
32,0
44,31
49,6
2,95
16,66
25,89
38,21
44,36
49,6
30,5
58,65
64,8
16,38
44,53
51,56
64,8
9,26
36,57
43,61
57,68
64,8
5,77
29,59
36,63
50,70
61,26
64,8
55,72
77,71
101,2
38,06
60,06
86,45
101,2
28,12
50,11
76,5
94,09
101,2
19,39
41,39
67,78
85,37
94,16
101,2
97,13
113,63
158,1
75,07
91,56
141,04
158,1
62,46
79,13
128,61
150,60
158,1
51,73
68,23
117,71
139,70
150,69
158,1
F180
[kN]
0,27
2,69
6,82
16,53
21,81
27,08
36,4
0,95
6,3
13,12
25,44
31,6
40,83
49,6
2,04
15,0
22,04
36,11
46,67
57,22
64,8
7,22
23,15
49,54
67,13
75,93
84,72
101,2
28,94
45,43
94,91
116,90
127,90
138,89
158,1
a)
For HIT-HY 150 MAX rebar only the standard acc. EC2 is available (Data also in Warringtonfire report
WF 166402 or/and IBMB Braunschweig report No 3884/8246-CM.
= lap length
675
Table 4: Critical temperature-dependent bond stress, crit,T, concerning overlap joint for Hilti-HIT-HY 150
MAX injection adhesive in relation to fire resistance class and required minimum concrete coverage c.
Clear concrete cover c
Max. bond stress, T [N/mm]
[mm]
F30
F60
F90
F120
F180
30
0,46
0
35
0,56
40
0,69
0
45
0,84
0,37
50
1,04
0,45
0
55
1,22
0,53
60
1,47
0,62
0
65
1,85
0,73
0,38
70
0,87
0,46
75
1,02
0,52
80
1,21
0,59
0,37
85
1,35
0,67
0,43
90
1,52
0,78
0,52
95
1,74
0,91
0,58
100
2,02
1,07
0,66
105
1,21
0,77
0,38
110
1,39
0,91
0,44
115
1,61
1,05
0,48
120
1,89
1,21
0,53
125
2,12
1,37
0,61
2,20
130
1,57
0,69
135
1,82
0,75
140
2,13
0,81
145
0,89
2,20
150
0,88
155
0,97
2,20
160
1,08
165
1,22
2,20
170
1,40
175
1,62
180
1,90
185
2,05
2,20
190
linst
676
1 / 2009
Table 5: Maximum force in rebar in conjuction with HIT-RE 500 as a function of embedment depth for the
fire resistance classes F30 to F240 (yield strength fyk = 500 N/mm) according EC2a).
Drill hole
Max. Fs,T
Fire resistance of bar in [kN]
Bar
linst
[mm]
[mm]
[kN]
[mm]
F30
F60
F90
F120
F180
F240
65
1,38
0,57
0,19
0,05
0
0
80
2,35
1,02
0,47
0,26
0
0
95
3,87
1,68
0,88
0,55
0,12
0
115
7,3
3,07
1,71
1,14
0,44
0,18
150
16,19
8,15
4,59
3,14
1,41
0,8
8
10
16,19
180
16,19
9,99
6,75
2,94
1,7
205
16,19
12,38
5,08
2,86
220
16,19
6,95
3,82
265
16,19
8,57
305
16,19
80
2,94
1,27
0,59
0,33
0
0
100
5,68
2,45
1,31
0,85
0,24
0
120
10,66
4,44
2,48
1,68
0,68
0,31
140
17,57
7,76
4,38
2,99
1,33
0,73
165
25,29
15,06
8,5
5,79
2,58
1,5
10
12
25,29
195
25,29
17,63
12,18
5,12
2,93
220
25,29
20,66
8,69
4,78
235
25,29
11,8
6,30
280
25,29
13,86
320
25,29
95
5,8
2,52
1,32
0,83
0,18
0
120
12,79
5,33
2,97
2,01
0,82
0,37
145
23,16
10,68
6,02
4,12
1,84
1,03
180
36,42
24,29
14,99
10,12
4,41
2,55
12
16
36,42
210
36,42
27,38
20,65
8,47
4,74
235
36,42
312,01
14,16
7,56
250
36,42
19,13
9,89
295
36,42
21,43
335
36,42
110
10,92
4,65
2,55
1,7
0,61
0,20
140
24,60
10,87
6,13
4,19
1,86
1,03
170
39,12
23,50
13,55
9,2
4,07
2,37
195
49.58
35,6
24,69
17,05
7,17
4,10
14
18
49.58
225
49.58
39,20
31,34
13,48
7,34
250
49.58
43,44
22,32
11,54
265
49.58
29,49
15,00
310
49.58
31,98
350
49.58
130
22,59
9,42
5,30
3,61
1,56
0,8
160
39,17
21,33
11,95
8,15
3,65
2,11
190
55,76
37,92
24,45
17,25
7,35
4,22
210
64,75
48,98
36,51
27,53
11,29
6,32
16
20
64,75
240
64,75
53,10
44,12
20,88
11,04
265
64,75
57,94
33,7
17,14
280
64,75
42,0
22,17
325
64,75
44,84
365
64,75
1 / 2009
677
Bar
[mm]
Drill hole
[mm]
Max. Fs,T
linst
[kN]
[mm]
F30
F60
F90
F120
F180
F240
160
48,97
26,67
14,93
10,18
4,56
2,64
200
76,61
54,31
38,73
27,5
11,42
6,48
240
101,18
81,96
66,37
55,15
26,10
13,8
270
101,18
87,11
75,88
45,58
23,36
25
101,18
20
295
101,18
93,16
62,86
35,72
310
101,18
73,23
45,69
355
101,18
76,79
395
101,18
200
95,77
67,89
48,41
34,37
14,27
8,10
250
138,96
111,09
91,60
77,51
39,86
20,61
275
158,09
132,69
113,2
99,17
61,30
31,81
305
158,09
139,12
125,09
87,22
52,79
25
30
158,09
330
158,09
146,69
108,82
74,39
345
158,09
121,77
87,34
390
158,09
126,22
430
158,09
255
183,40
147,72
122,78
104,82
56,35
28,80
275
205,52
169,84
144,90
126,94
78,46
40,71
325
259,02
225,13
200,19
182,23
133,75
89,68
368
259,02
238,89
220,93
172,46
128,39
32
40
259,02
380
259,02
243,05
194,58
150,51
395
259,02
211,16
167,09
440
259,02
216,86
480
259,02
290
249,87
209,73
181,67
161,46
106,93
59,1
325
293,41
253,27
225,21
205,01
150,47
100,89
355
327,82
290,59
262,54
242,33
187,80
138,22
385
327,82
299,86
279,65
225,12
175,54
36
44
327,82
410
327,82
310,75
256,22
206,64
425
327,82
274,88
225,30
470
327,82
281,28
510
327,82
320
319,10
274,50
243,33
220,87
160,28
105,19
355
367,48
322,88
291,71
269,25
208,66
153,57
385
404,71
364,35
333,18
310,72
250,13
195,04
415
404,71
374,64
352,19
291,60
236,51
40
47
404,71
440
404,71
386,75
326,16
271,07
455
404,71
346,89
291,80
500
404,71
354,01
540
404,71
a)
For tables according the standards to DIN 1045-1988, NF-ENV 1991-2-2(EC2), sterreichische Norm B 47002000, British-, Singapore- and Australian Standards see Warringtonfire report WF 166402 or/and IBMB
Braunschweig report No 3357/0550-5.
678
1 / 2009
ls
= lap length
Table 6: Critical temperature-dependent bond stress, crit,T, concerning overlap joint for Hilti-HIT RE 500
injection adhesive in relation to fire resistance class and required minimum concrete coverage c.
Clear concrete cover c
Max. bond stress, T [N/mm]
[mm]
F30
F60
F90
F120
F180
F240
10
0
0
20
0,494
0
30
0,665
0
40
0,897
0,481
0
50
1,209
0,623
0
60
1,630
0,806
0,513
70
2,197
1,043
0,655
0,487
80
2,962
1,351
0,835
0,614
90
3,992
1,748
1,065
0,775
0,457
100
5,382
2,263
1,358
0,977
0,553
110
7,255
2,930
1,733
1,233
0,669
0,469
120
9,780
3,792
2,210
1,556
0,810
0,551
130
4,909
2,818
1,963
0,980
0,647
140
6,355
3,594
2,477
1,185
0,759
150
8,226
4,584
3,125
1,434
0,829
160
10.649
5,846
3,943
1,735
1,047
170
7,456
4,974
2,099
1,230
180
9,510
6,276
2,540
1,445
190
7,918
3,037
1,697
200
9,990
3,718
1,993
210
4,498
2,341
11,00
220
5,442
2,749
230
6,584
3,228
11,00
240
7,966
3,792
11,00
250
9,639
4,453
11,00
260
5,230
270
6,143
280
7,214
11,00
290
8,473
300
9,951
310
11,00
1 / 2009
679
0.9
0.8
Sd,fat max
/ N Rd
0.7
FSd,fat
0.6
FSd,fat max
0.5
0.4
0.3
0.2
0.1
FSd,fat min
0
0
0.2
0.4
Sd,fat min
0.6
0.8
/ N Rd
time
Figure 4.13: Reduction factors for fatigue for bond and concrete
Hilti design software for rebar connections does also the fatigue design.
If the simplified method is not satisfying, additional information using the Woehler - lines is available.
Ask Hilti Technical Service for the Hilti Guideline: TWU-TPF 06a/02 Hilti HIT-Rebar: Fatigue.
680
1 / 2009
1 / 2009
681
Benefits
Hilti
HIT-RE 500
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
Rebar
Concrete
Fire
resistance
Fatigue
European
Technical
Approval
DIBt approval
Drinking
water
appoved
Corossion
tested
Marque NF
Hilti anchor
design
software
Hilti rebar
design
software
Approvals / certificates
Description
Authority / Laboratory
DIBt, Berlin
DIBt, Berlin
IBMB Braunschweig
Warringtonfire
ETA-08/0105 / 2008-05-26
Z-21.8-1790 / 2007-11-29
3357/0550-5 / 2002-07-30
WF 166402 / 2007-10-26
a)
682
1 / 2009
Materials
Reinforcmenent bars according to EC2 Annex C Table C.1 and C.2N.
Properties of reinforcement
Product form
Class
Characteristic yield strength fyk or f0,2k (MPa)
1,08
5,0
Bendability
Maximum deviation from
nominal mass
(individual bar) (%)
Bond:
Minimum relative rib area,
fR,min
C
1,15
< 1,35
7,5
6,0
4,5
0,040
0,056
Setting details
For detailed information on installation see instruction for use given with the package of the product.
For dry concrete curing times may be reduced according to the following table. For installation temperatures below
+5 C all load values have to be reduced according to the load reduction factors given below.
Load
reduction
factor
0,6
0,7
1
1
1
1
1
1
683
a)
) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 20 d only!
684
1 / 2009
Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only
a)
Note: Manual cleaning for element sizes d 16mm and embedment depth hef 20 d only!
685
Acids
Solvents
Environnement
Chemical substances
resistant
Non
resistant
Benzyl alcohol
Ethanol
Ethyl acetate
Trichlor ethylene
Xylol (mixture)
Concrete plasticizer
Diesel
Engine oil
Petrol
Sslt water
De-mineralised water
Electrical Conductivity
HIT-RE 500 in the hardened state is not conductive electrically. Its electric resistivity is 661012 .m
(DIN IEC 93 12.93). It is adapted well to realize electrically insulating anchorings (ex: railway applications,
subway).
686
1 / 2009
Bond strength
Bond strength in N/mm according to ETA for good bond conditions
for hammer drilling, compressed air drilling, dry diamond core drilling
Rebar (mm)
Concrete class
C12/15
C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
10
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
12
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
14
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
16
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
18
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
20
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
22
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
24
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
25
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
26
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
28
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
30
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
32
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
34
1,6
2,0
2,3
2,6
2,9
3,3
3,6
3,9
4,2
36
1,5
1,9
2,2
2,6
2,9
3,3
3,6
3,8
4,1
40
1,5
1,8
2,1
2,5
2,8
3,1
3,4
3,7
4,0
1 / 2009
687
Concrete class
C12/15
C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
10
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
12
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
14
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
16
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
18
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
20
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
22
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
24
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
25
1,6
2,0
2,3
2,7
3,0
3,4
3,7
4,0
4,3
26
1,6
2,0
2,3
2,7
2,7
2,7
2,7
2,7
2,7
28
1,6
2,0
2,3
2,7
2,7
2,7
2,7
2,7
2,7
30
1,6
2,0
2,3
2,7
2,7
2,7
2,7
2,7
2,7
32
1,6
2,0
2,3
2,7
2,7
2,7
2,7
2,7
2,7
34
1,6
2,0
2,3
2,6
2,6
2,6
2,6
2,6
2,6
36
1,5
1,9
2,2
2,6
2,6
2,6
2,6
2,6
2,6
40
1,5
1,8
2,1
2,5
2,5
2,5
2,5
2,5
2,5
688
1 / 2009
Minimum and maximum embedment depths and lap lengths for C20/25 according
to ETA
Hammer drilling,
Compressed air drilling,
Dry diamond coring drilling
Rebar
Diameter
ds
[mm]
fy,k
[N/mm]
lb,min*
[mm]
l0,min *
[mm]
lb,min*
[mm]
l0,min *
[mm]
lmax
[mm]
500
113
200
170
300
1000
10
500
142
200
213
300
1000
12
500
170
200
255
300
1200
14
500
198
210
298
315
1400
16
500
227
240
340
360
1600
18
500
255
270
383
405
1800
20
500
284
300
425
450
2000
22
500
312
330
468
495
2200
24
500
340
360
510
540
2400
25
500
354
375
532
563
2500
26
500
369
390
553
585
2600
28
500
397
420
595
630
2800
30
500
425
450
638
675
3000
32
500
454
480
681
720
3200
34
500
492
510
738
765
3200
36
500
532
540
797
810
3200
500
616
621
925
932
3200
40
lb,min (8.6) and l0,min (8.11) are calculated for good bond conditions with maximum utilisation of rebar yield strength
fyk = 500 N/mm and 6 = 1,0
1 / 2009
689
Precalculated values
Example of pre-calculated values for anchoring
Rebar yield strength fyk = 500 N/mm, concrete C25/30, good bond conditions
For all drilling procedures, excluding wet diamond core drilling (DD)
Anchorage
Design
Mortar
Anchorage
Rebar
length lbd
value NRd
volume
length lbd
[mm]
[mm]
[kN]
[ml]
[mm]
Design
Mortar
value NRd
volume
[kN]
[ml]
2 or 5= 0.7
1=2=3=4=5=1.0
1 = 3 = 4 = 1.0
100
6,79
8
100
9,70
8
160
10,86
12
160
15,52
12
8
200
13,58
15
322
21,87
24
225
17
21,87
121
10,24
11
121
14,63
11
200
16,96
18
200
24,22
18
10
250
21,20
23
250
30,28
23
300
25,43
27
403
34,13
36
282
34,13
25
145
14,74
15
145
21,06
15
240
24,41
25
240
34,87
25
12
300
30,51
32
300
43,59
32
360
36,61
38
483
49,13
51
338
49,13
36
169
20,09
20
169
28,70
20
280
33,26
34
280
47,52
34
14
350
41,58
42
350
59,40
42
480
57,02
58
564
66,96
68
395
66,96
48
193
26,22
26
193
37,45
26
320
43,42
43
320
62,02
43
16
400
54,27
54
400
77,53
54
480
65,12
65
644
87,39
87
451
87,39
61
217
36,86
46
217
52,66
46
360
61,04
76
360
87,20
76
18
450
76,30
95
450
109,00
95
540
91,56
115
725
122,87
154
507
122,87
108
242
40,96
51
242
58,51
51
400
67,82
85
400
96,89
85
20
500
84,78
106
500
121,11
106
600
101,74
127
805
136,52
171
564
136,52
120
266
49,57
56
266
70,81
56
440
82,08
93
440
117,26
93
22
550
102,60
117
550
146,58
117
660
123,12
140
886
165,22
188
620
165,22
131
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-d)lb/4
690
1 / 2009
Design
Mortar
value NRd
volume
[kN]
[ml]
2 or 5= 0.7
1=2=3=4=5=1.0
1 = 3 = 4 = 1.0
290
58,97
61
290
84,24
61
480
97,65
102
480
139,51
102
24
600
122,07
127
600
174,38
127
720
146,48
153
966
196,57
205
676
196,57
143
302
64,04
114
302
91,49
114
500
106,06
188
500
151,51
188
25
625
132,57
235
625
189,39
235
750
159,08
282
1 006
213,48
378
705
213,48
265
314
69,26
67
314
98,94
67
520
114,70
110
520
163,85
110
26
650
143,37
138
650
204,81
138
780
172,04
165
1 047
230,87
222
733
230,87
155
338
80,35
72
338
114,78
72
600
142,56
127
600
203,66
127
28
700
166,32
148
700
237,60
148
840
199,59
178
1 127
267,83
239
789
267,83
167
362
92,22
160
362
131,74
160
600
152,71
265
600
218,16
265
30
750
190,89
332
750
272,70
332
900
229,07
398
1 418
360,91
627
845
307,39
374
386
104,87
210
386
149,81
210
640
173,66
347
640
248,09
347
32
800
217,08
434
800
310,11
434
960
260,50
521
1 288
349,57
699
902
349,57
490
426
118,43
90
426
169,19
90
680
188,86
144
680
269,81
144
34
850
236,08
180
850
337,26
180
1 020
283,30
216
1 421
394,78
301
995
394,78
211
452
132,78
96
452
189,69
96
720
211,74
153
720
302,49
153
36
900
264,68
191
900
378,11
191
1 080
317,61
229
1 505
442,60
319
1 054
442,60
223
522
163,96
701
522
234,22
701
800
251,40
1 074
800
359,14
1 074
40
1 000
314,25
1 343
1 000
448,93
1 343
1 200
377,10
1 612
1 739
546,52
2 336
1 217
546,52
1 635
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-ds)lb/4 for hammer drilling
1 / 2009
691
Design
Mortar
value NRd
volume
[kN]
[ml]
2 or 5= 0,7
1=2=3=5=6=1,0
1 = 3 = 6 = 1,0
200
13,58
15
200
19,40
15
250
16,98
19
8
300
20,37
23
322
21,87
24
225
17
21,87
200
16,96
18
200
24,22
18
250
21,20
23
250
30,28
23
10
300
25,43
27
350
29,67
32
403
34,13
36
282
34,13
25
200
20,34
21
200
29,06
21
240
24,41
25
240
34,87
25
12
300
30,51
32
300
43,59
32
360
36,61
38
483
49,13
51
338
49,13
36
210
24,95
25
210
35,64
25
280
33,26
34
280
47,52
34
14
350
41,58
42
350
59,40
42
480
57,02
58
564
66,96
68
395
66,96
48
240
32,56
33
240
46,52
33
320
43,42
43
320
62,02
43
16
400
54,27
54
400
77,53
54
480
65,12
65
644
87,39
87
451
87,39
61
270
45,78
57
270
65,40
57
360
61,04
76
360
87,20
76
18
450
76,30
95
450
109,00
95
540
91,56
115
725
122,87
154
507
122,87
108
300
50,87
64
300
72,67
64
400
67,82
85
400
96,89
85
20
500
84,78
106
500
121,11
106
600
101,74
127
805
136,52
171
564
136,52
120
330
61,56
70
330
87,95
70
440
82,08
93
440
117,26
93
22
550
102,60
117
550
146,58
117
660
123,12
140
886
165,22
188
620
165,22
131
Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good
bond conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume
of mortar correspond to the formula 1,2(d0-ds)lb/4 for hammer drilling
692
1 / 2009
Design
Mortar
value NRd
volume
[kN]
[ml]
2 or 5= 0.7
1=2=3=4=5=1.0
1 = 3 = 4 = 1.0
360
73,24
76
360
104,63
76
480
97,65
102
480
139,51
102
24
600
122,07
127
600
174,38
127
720
146,48
153
966
196,57
205
676
196,57
143
375
79,54
141
375
113,63
141
500
106,06
188
500
151,51
188
25
625
132,57
235
625
189,39
235
750
159,08
282
1 006
213,48
378
705
213,48
265
390
86,02
83
390
122,89
83
520
114,70
110
520
163,85
110
26
650
143,37
138
650
204,81
138
780
172,04
165
1 047
230,87
222
733
230,87
155
420
99,79
89
420
142,56
89
600
142,56
127
600
203,66
127
28
700
166,32
148
700
237,60
148
840
199,59
178
1 127
267,83
239
789
267,83
167
450
114,53
199
450
163,62
199
600
152,71
265
600
218,16
265
30
750
190,89
332
750
272,70
332
900
229,07
398
1 418
360,91
627
845
307,39
374
480
130,25
261
480
186,07
261
640
173,66
347
640
248,09
347
32
800
217,08
434
800
310,11
434
960
260,50
521
1 288
349,57
699
902
349,57
490
510
141,65
108
510
202,35
108
680
188,86
144
680
269,81
144
34
850
236,08
180
850
337,26
180
1 020
283,30
216
1 421
394,78
301
995
394,78
211
540
158,81
115
540
226,87
115
720
211,74
153
720
302,49
153
36
900
264,68
191
900
378,11
191
1 080
317,61
229
1 505
442,60
319
1 054
442,60
223
600
188,55
806
600
269,36
806
800
251,40
1 074
800
359,14
1 074
40
1 000
314,25
1 343
1 000
448,93
1 343
1 200
377,10
1 612
1 739
546,52
2 336
1 217
546,52
1 635
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-ds)lb/4 for hammer drilling
1 / 2009
693
Benefits
Hilti
HIT-HY 150
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
Rebar
Concrete
Fire
resistance
Fatigue
DIBt approval
Drinking
water
appoved
Corossion
tested
Hilti anchor
design
software
Hilti rebar
design
software
Approvals / certificates
Description
Authority / Laboratory
DIBt approval
Fire test report
Assessment report (fire)
DIBt, Berlin
IBMB Braunschweig
Warringtonfire
Z-21.8-1648 / 2007-09-19
3162/6989 / 1999-07-16
WF 166402 / 2007-10-26
a)
a)
The data given in this section are derived from DIBt Z-21.8-1648 issue 2007-09-19 and adapted to fit EC2
design method.
Materials
Reinforcmenent bars according to EC2 Annex C Table C.1 and C.2N.
694
1 / 2009
Properties of reinforcement
Product form
Class
C
400 to 600
1,08
1,15
< 1,35
5,0
7,5
Bendability
6,0
4,5
Bond:
Minimum relative rib area,
fR,min
0,040
0,056
Setting details
For detailed information on installation see instruction for use given with the package of the product.
0 C
5 C
10 C
20 C
30 C
40 C
Working time
tgel
90 min
45 min
20 min
6 min
4 min
2 min
Curing time
tcure *
9 h
4,5 h
2 h
90 min
50 min
40 min
The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing
times must be doubled.
1 / 2009
695
a)
a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
696
1 / 2009
Chemical product
Acetic acid
Hydrochloric Acid
Nitric Acid
Phosphoric Acid
Sulphuric acid
Ethyl acetate
Acetone
Ammoniac
Diesel
Gasoline
Ethanol
Machine oils
Methanol
Peroxide of hydrogen
Solution of phenol
Silicate of sodium
Solution of chlorine
Solution of hydrocarbons
Salted solution (sodium
chloride)
Suspension of cement
Carbon tetrachloride
Xylene
Concentration
First effects
(in % of weight)
(in days)
Pure
6
10 %
20 %
40 %
<1
40 %
40 %
Pure
8
Pure
1
5%
21
Pure
Pure
96 %
30
Pure
Pure
2
30%
3
Saturated
<1
50% pH=14!
saturated
60 % vol Toluene; 30 % vol
Xylene
10 % vol Naphtalene of methyl
10 %
Saturated
Pure
Pure
Resistance
o
+
+
+
+
+
+
o
+
o
+
+
+
+
+
+
+
We can retain that HIT-HY 150 behaves well as alkaline middle and that it is very resistant:
in aqueous solutions in elevated pH (ex: silicate of sodium): no risk of saponification under weathering
in salty solutions (ex: sea water)
in solutions saturated in chlorine (ex: applications in swimming pool).
Electrical conductivity
HIT-HY 150 in cured state shows low electrical conductivity. Its electric resistivity is 2.1011 .m
(DIN VDE 0303T3). It suits well electrically insulating anchoring (ex: railway applications, subway).
1 / 2009
697
Bond strength
Bond strength in N/mm according to EC2 for good bond conditions
for all drilling methods
Concrete class
Rebar (mm)
C12/15
C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
10
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
12
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
14
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
16
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
18
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
20
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
22
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
24
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
25
1,6
2,0
2,3
2,7
3,0
3,0
3,0
3,0
3,0
Rebar
Diameter ds
[mm]
fy,k
[N/mm]
lb,min*
[mm]
l0,min *
[mm]
lmax
500
170
300
[mm]
1000
10
500
213
300
1000
12
500
255
300
1000
14
500
298
315
1000
16
500
340
360
1500
20
500
425
450
2000
25
500
532
563
2000
*lb,min (8.6) and l0,min (8.11) are calculated for good bond conditions with maximum utilisation of
rebar yield strength fyk = 500 N/mm and 6 = 1,0
698
1 / 2009
Precalculated values
Example of pre-calculated values for anchoring
Rebar yield strength fyk = 500 N/mm, concrete C25/30, good bond conditions
Rebar
[mm]
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
1=2=3=4=5=1.0
Mortar
volume
[ml]
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
2 or 5= 0.7
1 = 3 = 4 = 1.0
9,37
16,53
21,87
21,94
18,06
30,95
34,13
31,58
37,13
44,55
Mortar
volume
[ml]
170
9,84
13
113
9
200
11,57
15
200
15
8
320
18,51
24
378
29
265
20
21,87
213
15,36
19
213
19
250
18,06
23
250
23
10
300
21,67
27
300
27
400
28,89
36
473
34,13
43
331
30
255
22,11
27
255
27
300
25,99
32
300
32
12
360
31,19
38
360
38
480
41,58
51
567
49,13
60
397
49,13
42
298
30,13
36
298
43,04
36
400
40,48
48
400
57,83
48
14
420
42,50
51
420
60,72
51
560
56,67
68
662
66,96
80
463
66,96
56
340
39,33
46
340
56,18
46
400
40,48
54
400
66,04
54
16
480
55,48
65
480
79,25
65
640
73,97
87
756
87,39
103
529
87,39
72
425
61,43
90
425
87,76
90
500
72,22
106
500
103,17
106
20
600
86,66
127
600
123,81
127
800
115,55
170
945
136,52
200
662
136,52
140
532
96,07
200
532
137,24
200
600
108,41
226
600
154,88
226
25
750
135,52
282
750
193,59
282
1000
180,69
376
1181
213,48
444
827
213,48
311
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-d)lb/4
1 / 2009
699
Design
Mortar
value NRd
volume
[mm]
[kN]
[ml]
2 or 5= 0,7
1=2=3=5=6=1,0
1 = 3 = 6 = 1,0
300
17,35
23
300
21,85
23
310
17,93
23
8
320
18,51
24
378
29
21,87
300
21,67
27
300
30,95
27
320
23,11
29
320
33,01
29
10
350
25,28
32
400
28,89
36
473
43
331
34,15
30
34,13
300
25,99
32
300
37,13
32
320
27,72
34
320
33,01
29
12
350
30,32
37
350
43,32
37
480
41,58
51
567
49,12
60
397
49,13
42
315
31,88
38
315
45,54
38
350
35,42
42
350
50,60
42
14
420
42,50
51
420
60,72
51
560
56,67
68
662
66,99
80
463
66,94
56
460
53,16
62
460
75,95
62
470
54,32
64
470
77,60
64
16
480
55,48
65
480
79,25
65
640
73,97
87
756
87,37
103
529
87,34
72
450
65,00
95
450
92,85
95
500
72,22
106
500
103,17
106
20
600
86,66
127
600
123,81
127
800
115,55
170
945
136,50
200
662
136,60
140
563
101,73
212
563
145,32
212
600
108,41
226
600
154,88
226
25
750
135,52
282
750
193,59
282
1000
180,69
376
1181
213,39
444
827
213,47
311
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-ds)lb/4
Rebar
700
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
Mortar
volume
[ml]
Anchorage
length lbd
[mm]
1 / 2009
1 / 2009
701
Benefits
Hilti
HIT-HY 150
MAX
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Static mixer
Rebar
Concrete
Fire
resistance
Fatigue
European
Technical
Approval
CE
conformity
Drinking
water
appoved
Corossion
tested
Hilti anchor
design
software
Hilti rebar
design
software
Approvals / certificates
Description
Authority / Laboratory
CSTB, France
IBMB Braunschweig
Warringtonfire
ETA-08/0202 / 2008-07-24
3884/8246 / 2007-05-24
WF 166402 / 2007-10-26
Materials
Reinforcmenent bars according to EC2 Annex C Table C.1 and C.2N.
702
1 / 2009
Properties of reinforcement
Product form
Class
C
400 to 600
1,08
1,15
< 1,35
5,0
7,5
Bendability
6,0
4,5
Bond:
Minimum relative rib area,
fR,min
0,040
0,056
Setting details
For detailed information on installation see instruction for use given with the package of the product.
1 / 2009
Working time
tgel
180 min
90 min
45 min
20 min
7 min
6 min
5 min
3 min
2 min
Curing time
tcure
12 h
9h
4,5 h
2h
50 min
40 min
30 min
30 min
30 min
703
a)
a) Note: Manual cleaning for element sizes d 16mm and embedment depth hef 10 d only!
704
1 / 2009
Water behaviour
Water: HIT-HY 150 MAX is water tight and water resistant, without any toxicity risk for the environnement.
Drinking water: HIT-HY 150 MAX is NSF certified, in accordance with NSF/ANSI St 61 Drinking Water
System Components - Health Effects. Tests are done at 60 C, which corresponds to domestic hot water. The
use of HIT-HY 150 MAX is possible for water tanks.
Comment
Resistance
Sulphuric acid
Under sea water
Under water
Alkaline medium
23C
23C
23C
pH = 13,2, 23C
+
+
+
+
Bond strength
Bond strength in N/mm according to ETA for good bond conditions
for all drilling methods
Rebar (mm)
Concrete class
C12/15
C16/20
C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
C50/60
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
10
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
12
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
14
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
16
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
18
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
20
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
22
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
24
1,6
2,0
2,3
2,7
3,0
3,4
3,4
3,4
3,7
25
1,6
2,0
2,3
2,7
3,0
3,4
3,7
3,7
3,7
705
Rebar
Diameter ds
[mm]
fy,k
[N/mm]
lb,min*
[mm]
l0,min *
[mm]
500
500
500
500
500
500
500
500
500
500
113
142
170
198
227
255
284
312
340
354
200
200
200
210
240
270
300
330
360
375
10
12
14
16
18
20
22
24
25
lmax
[mm]
1000
1000
1000
1000
1500
2000
2000
2000
2000
2000
lb,min (8.6) and l0,min (8.11) are calculated for good bond conditions with maximum utilisation of rebar yield strength
fyk = 500 N/mm and 6 = 1,0
706
1 / 2009
Precalculated values
Example of pre-calculated values for anchoring
Rebar yield strength fyk = 500 N/mm, concrete C25/30, good bond conditions
Rebar
[mm]
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
1=2=3=4=5=1.0
Mortar
volume
[ml]
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
2 or 5= 0.7
1 = 3 = 4 = 1.0
9,37
16,53
21,87
14,63
20,63
30,95
34,13
21,06
29,70
44,55
Mortar
volume
[ml]
113
6,56
9 (4)**
113
9 (4)**
200
11,57
15 (7)**
200
15 (7)**
8
320
18,51
24
378
29
265
20
21,87
142
10,24
13 (6)**
142
13 (6)**
200
14,44
18 (8)**
200
18 (8)**
10
300
21,67
27
300
27
400
28,89
36
473
34,13
43
331
30
170
14,74
18 (8)**
170
18 (8)**
240
20,79
25 (12)**
240
25 (12)**
12
360
31,19
38
360
38
480
41,58
51
567
49,13
60
397
49,13
42
198
20,09
24
198
28,70
24
280
28,34
34
280
40,48
34
14
420
42,50
51
420
60,72
51
560
56,67
68
662
66,96
80
463
66,96
56
227
26,22
31
227
37,45
31
320
36,98
43
320
52,83
43
16
480
55,48
65
480
79,25
65
640
73,97
87
756
87,39
103
529
87,39
72
255
33,13
38
255
47,33
38
360
46,74
54
360
66,77
54
18
540
70,10
81
540
100,15
81
720
93,47
109
851
110,48
128
595
110,35
90
284
40,96
60
284
58,51
60
400
57,78
85
400
82,54
85
20
600
86,66
127
600
123,81
127
800
115,55
170
945
136,52
200
662
136,52
140
312
49,57
88
312
70,81
88
440
69,92
124
440
99,89
124
22
660
104,88
187
660
149,83
187
880
139,84
249
1040
165,27
294
728
165,27
206
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-d)lb/4 (** values correspond to min. hole diameter)
1 / 2009
707
Design
Mortar
value NRd
volume
[mm]
[kN]
[ml]
2 or 5= 0.7
1=2=3=4=5=1.0
1 = 3 = 4 = 1.0
340
58,96
144
340
84,22
144
480
83,17
203
480
118,81
203
24
720
124,75
304
720
178,22
304
960
166,34
405
1134
196,48
479
794
196,53
335
354
64,04
133
354
91,49
133
500
90,34
188
500
129,06
188
25
750
135,52
282
750
193,59
282
1000
180,69
376
1181
213,48
444
827
213,48
311
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-ds)lb/4 (** values correspond to min. hole diameter)
Rebar
708
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
Mortar
volume
[ml]
Anchorage
length lbd
[mm]
1 / 2009
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
1=2=3=5=6=1,0
Mortar
volume
[ml]
Anchorage
length lbd
[mm]
Design
value NRd
[kN]
2 or 5= 0,7
1 = 3 = 6 = 1,0
16,53
21,87
20,63
30,95
34,13
24,77
29,70
44,55
Mortar
volume
[ml]
200
11,57
15 (7)**
200
15 (7)**
320
18,51
24
378
29
265
20
21,87
200
14,44
18 (8)**
200
18 (8)**
300
21,67
27
300
27
10
400
28,89
36
473
43
331
30
34,13
200
17,34
21 (10)**
200
21 (10)**
240
20,79
25 (12)**
240
25 (12)**
12
360
31,19
38
360
38
480
41,58
51
567
49,13
60
397
49,13
42
210
21,24
25
210
30,34
25
280
28,34
34
280
40,48
34
14
420
42,50
51
420
60,72
51
560
56,67
68
662
66,96
80
463
66,96
56
240
27,75
33
240
39,64
33
320
36,98
43
320
52,83
43
16
480
55,48
65
480
79,25
65
640
73,97
87
756
87,39
103
529
87,39
72
270
35,12
41
270
50,17
41
360
46,74
54
360
66,77
54
18
540
70,10
81
540
100,15
81
720
93,47
109
851
110,48
128
595
110,35
90
300
43,35
64
300
61,93
64
400
57,78
85
400
82,54
85
20
600
86,66
127
600
123,81
127
800
115,55
170
945
136,52
200
662
136,52
140
330
52,46
93
330
74,94
93
440
69,92
124
440
99,89
124
22
660
104,88
187
660
149,83
187
880
139,84
249
1040
165,27
294
728
165,27
206
360
62,43
152
360
89,19
152
480
83,17
203
480
118,81
203
24
720
124,75
304
720
178,22
304
960
166,34
405
1134
196,48
479
794
196,53
335
375
67,74
141
375
96,71
141
500
90,34
188
500
129,06
188
25
750
135,52
282
750
193,59
282
1000
180,69
376
1181
213,48
444
827
213,48
311
* Values corresponding to the minimum anchorage length. The maximum permissible load is valid for good bond
conditions as described in EN 1992-1-1. For all other conditions multiply by the value by 0,7. The volume of
mortar correspond to the formula 1,2(d0-ds) lb/4 (** values correspond to min. hole diameter)
8
1 / 2009
709
Hilti worldwide
Hilti worldwide
Afghanistan
Ansary Engineering Products &
Services (AEP), Hilti Division,
Kabul
Phone +93 799 481 935
Belgium
Hilti Belgium S.A., Asse (Zellik)
Phone+32 2 4677911
Fax+32 2 4665802
Chile
Hilti Chile, Ltda.,Santiago
Phone+562 655 3000
Fax+562 365 0505
Algeria
BFIX SARL, Algiers
Phone+213 216 013 60
Fax+213 216 055 03
Belize
Benny's Homecenter Ltd.,
Belize City,
Phone+501 227 2126
Fax+501 227 4340
China
Hilti (China) Ltd., Shanghai
Phone+86 21 6485 3158
Fax+86 21 6485 0311
Angola
Agrinsul S.A.R.L, Luanda
Phone+244 222 395 884
Fax+244 222 397 935
Argentina
Hilti Argentina, S.R.L., Buenos
Aires
Phone+54 11 4721 4400
Fax+54 11 4721 4410
Aruba
Carfast Holding N.V, Oranjestad
Phone +297-5-828-449
Fax +297-5-832-582
Australia
Hilti (Aust.) Pty. Ltd., Rhodes
Phone+61 2 8748 1000
Fax+61 2 8748 1190
Austria
Hilti Austria Ges.m.b.H., Wien
Phone+43 1 66101
Fax+43 1 66101 257
Azerbaijan
HCA Ltd., Baku
Phone+994 12 598 0955
Fax+994 12 598 0957
Bahrain
Hilti Bahrain LLC, Manama
Phone +973 17 702 101
Fax +973 17 702
Bangladesh
Aziz & Company Ltd., Hilti
Division,
Dhaka
Phone+8802 881 4461
Fax+8802 8827028
Barbados
Williams Equipment, Ltd.,
St.Michel
Phone+1 246 425 5000
Fax+1 246 417 9140
710
Benin
La Roche S.A.R.L., Cotonou
Phone+229 21330775
Fax+229 21331920
Bhutan
Hilti Regional Office
Middle East & South Asia Region,
Dubai
Phone+9714 8835376
Fax+9718 4480485
Bolivia
Genex, S.A., Santa Cruz
Phone+591 3 343 1819
Fax+591 3 343 1819
Bosnia and Herzegovina
Hilti Systems BH d.o.o. Sarajevo,
Sarajevo-Ilida
Phone +387 33 761 100
Fax +387 33 761 101
Botswana
Turbo Agencies, Gaborone
Phone+267 312288
Fax+267 352925
Brazil
Hilti do Brasil Comercial Ltda.,
Barueri
Phone+55 11 4134 9000
Fax+55 11 4134 9021
Bulgaria
Hilti (Bulgaria) GmbH, Sofia
Phone +359 2976 00 11
Fax +359 2974 01 23
Canada
Hilti (Canada) Ltd.,
Mississauga, Ontario
Phone 1-800-363-4458
Fax 1-800-363-4459
Cayman Islands
Active Traders Ltd., Georgetown
Phone +345-769-4458
Fax +345-769-5886
Colombia
Hilti Colombia, Bogot
Phone+571 3810121/3810134
Fax+571 3810131
Costa Rica
Superba S.A., La Uruca, San Jos
Phone+506 255 1044
Fax+506 255 1110
Croatia
Hilti Croatia d.o.o., Sesvete-Zagreb
Phone+385 1 2030 777
Fax+385 1 2030 766
Cyprus
Cyprus Trading Corp. Ltd., Nicosia
Phone+357 22 740340
Fax+357 22 482892
Czech Republik
Hilti CR spol. s r.o, Prag-Pruhonice
Phone+420 2 611 95 611
Fax+420 2 726 80 440
Denmark
Hilti Danmark A/S, Rdovre
Phone +45 88 8000
Fax +45 44 88 8084
Dominican Republik
Dalsan C por A, Santo Domingo
Phone+1 809 565 4431
Fax+1 809 541 7313
Ecuador
Quifatex S.A., Quito
Phone+593 2 247 7400
Fax+593 2 247 8600
Egypt
M.A.P.S.O. for Marine Propulsion &
Supply S.A.E., Cairo
Phone +202 2 698 47 77
Fax+202 2 698 82 60
El Salvador
Electrama, S.A. de C.V.,
San Salvador
Phone+503 274 9745
Fax+503 274 9747
1 / 2009
Hilti worldwide
Estonia
Hilti Eesti O, Tallinn
Phone+372 6 550 900
Fax+372 6 550 901
Ethiopia
A. Sarafian Industrial Accessories
& Tools, Addis Ababa
Phone+251 115512408
Fax+251 115519068
Fiji
Central Pacific Agencies,
Suva
Phone+ 679 336 2580
Finland
Hilti (Suomi) OY, Vantaa
Phone+358 9 47870 0
Fax+358 9 47870 100
France
Hilti France S.A.,
Magny-les-Hameaux
Phone+33 1 3012 5000
Fax+331 3012 5012
Gabon
CECA-GADIS, Libreville
Phone+241 740747
Fax+241 720416
Georgia
ICT Georgia Ltd., Tbilisi
Phone+995 32 25 38 42
Germany
Hilti Deutschland GmbH, Kaufering
Phone+49 8191/90-0
Fax+49 8191/90-1122
Ghana
Auto Parts Limited, Accra
Phone+233 21225924
Fax+233 21224899
Great Britain
Hilti (Gt. Britain) Ltd.,
Manchester
Phone+44 161 886 1000
Fax+44 161 872 1240
Guyana
Agostini's Fastening Systems Ltd.,
Port of Spain
Phone +1 868 623 2236
Fax+1 868 624 6751
Honduras
Lazarus & Lazarus, S.A.,
San Pedro Sula
Phone+504 565 8882
Fax+504 565 8624
Hong Kong
Hilti (Hong Kong) Ltd.,
Tsimshatsui, Kowloon
Phone+852 8228 8118
Fax+852 2764 3234 (main)
Hungary
Hilti (Hungria), Budapest
Phone+36 1 4366 300
Fax+36 1 4366 390
Iceland
HAGI ehf HILTI Iceland, Reykjavik
Phone+354 4143700
Fax+354 4143720
India
Hilti India Pvt Ltd., New Dehli
Phone +91 11 4270 1111
Fax+91 11 2637 1634
Indonesia
P.T. Hilti Nusantara,
Jakarta
Phone+62 21 / 789-0850
Fax+62 21 / 789-0845
Iran
Madavi Company, Hilti Division,
Tehran
Phone+98 21 81 721
Fax+98 21 887 61 523
Iraq
Systems Engineering Services Co.
(SESCO), Hilti Division, Baghdad
Phone+964 1 778 8933
Phone+964 7901 309592
Greece
Hilti Hellas SA, Likovrisi
Phone+30210 288 0600
Fax+30210 288 0607
Ireland
Hilti (Fastening Systems) Ltd.,
Dublin
Phone+353 1 886
Fax+353 1 886 3569
Guatemala
Equipos y Fijaciones, S.A.,
Guatemala City
Phone+502 339 3583
Fax+502 339 3585
Israel
Hilti (Israel) Ltd., Petach Tikva
Phone+972 3 930 4499
Fax+972 3 930 2095
1 / 2009
Italy
Hilti Italia S.p.A., Milano
Phone+3902 212721
Fax+3902 25902189
Jamaica
Evans Safety Ltd., Kingston
Phone+1 876 929 5546
Fax+1 876 926 2069
Japan
Hilti (Japan) Ltd., Yokohama
Phone+81 45 943 6211
Fax+81 45 943 6231
Jordan
Newport Trading Agency, Hilti
Division, Amman
Phone +962 6 4026829
Fax+962 6 4026794
Kazakhstan
EATC Ltd., Almaty
Phone +7327 298 01 80
Fax+7 3272 50 39 57
Korea
Hilti (Korea) Ltd., Seoul,
Phone +82 2 2007 2802
Fax +82 2 2007 2809
Kuwait
Works & Building Co, Hilti Division,
Safat
Phone+965 844 855
Fax+965 4831379
Latvia
Hilti Services Limited, Riga
Phone+371 762 8822
Fax+371 762 8821
Lebanon
Chehab Brothers S.A.L.,
Hilti Division, Beirut
Phone+9611 244435
Fax+9611 244436
Libya
Wemco Workshop & Maintenance
Equipments Co., Tripoli
Phone+ 218 21 4801213
Fax+ 218 21 4802810
Liechtenstein
Hilti Aktiengesellschaft, Schaan
Liechtenstein
Phone+423 234 2111
Fax+423 234 2965
Lithuania
UAB Hilti Complete Systems, Vilnius
Phone+370 6 872 7898
Fax+370 5 271 5341
711
Hilti worldwide
Luxembourg
Hilti G.D. Luxembourg, Bertrange
Phone+352 310 705
Fax+352 310 751
Mozambique
Diatecnica Lda., Maputo
Phone+2581 303816
Fax+2581 303804
Macedonia
Famaki-ve doel, Skopje
Phone+389 2 246 96
Fax+389 2 246 99 97
Namibia
A. Huester Machinetool Company
(Pty) Ltd., Windhoek
Phone+26461 237083
Fax+26461 227696
Madagascar
Socit F. Bonnet Et Fils,
Antananarivo
Phone+261 202220326
Fax+261 202222253
Malaysia
Hilti (Malaysia) Sdn. Bhd.,
Petaling Jaya
Phone+60 3 563 38583
Fax+60 3 563 37100
Maledives
Aima Con. Co. Pvt. Ltd,
Hilti Division, Mal
Phone +960 3318181
Fax+960 3313366
Nepal
INCO (P) Ltd., Kathmandu
Phone+9771 4431 992
Phone+9771 4433 045
Fax+9771 4432 728
Palestine
Shaer United Co. for Modern
Technology, Beit Jala
Phone+970 2 276 5840
Fax+970 2 274 7355
Panama
Cardoze & Lindo,
Ciudad de Panam
Phone+507 274 9300
Fax+507 267 1122
Peru
Qumica Suiza SA, Lima
Phone+511 211 4000
Fax+511 211 4050
Netherlands
Hilti Nederland B.V.,
Berkel en Rodenrijs
Phone+3110 5191111
Fax+3110 5191199
Philippines
Hilti (Philippines) Inc., Makati City
Phone+63 2 843 0066
Phone-2-893 9438
Fax+63 2 843 0061
Netherlands Antilles
Fabory Carribbean Fasteners N.V.,
Davelaar
Phone+599 9 737 6288
Fax+599 9 737 6225
Poland
Hilti (Poland) Sp. z o.o., Warsaw
Phone +48 320 5500
Fax +48 22 320 5500
New Zealand
Hilti (New Zealand) Ltd., Auckland
Phone +64 9 571 9995
Fax+64 9 571 9942
Portugal
Hilti (Portugal), Produtos e Servicos,
Lda., Matosinhos Senhora Da Hora,
Phone +351 229 568 100
Fax+35122 9568190
Mauritius
Ireland Blyth Limited, Port Louis
Phone+230 207 05 00
Fax+230 207 04 41
Nicaragua
Fijaciones de Nicaragua, Managua
Phone+505 270 4567
Fax+505 278 5331
Puerto Rico
Hilti Caribe, Inc., Hato Rey,
Phone+1-787 281 6160
Fax+1 787 281 6155
Mexico
Hilti Mexicana, S.A. de C.V.,
Mexico City
Phone+5255 5387-1600
Fax+5255 5281-5967
Nigeria
Top Brands Import Ltd., Hilti
Division
Ikeja
Phone +234 1 817 97 601
Fax+234 1 496 22 00
Qatar
H.B.K. Trading Co., Hilti Division,
Doha
Phone+974 4425022
Fax+974 435 6098
Malta
Panta Marketing & Services Ltd.,
Msida
Phone+356 21 441 361
Fax+356 21 440 000
Moldova
Sculcom Grup SRL, Chisinau
Phone+373 22 212488
Fax+373 22 238196
Mongolia
PSC CO. LTD., Hilti Division,
Ulaan Baatar
Phone+976 +50 88 45 84
Fax+976 50 88 45 85
Morocco
Mafix SA, Casablanca
Phone+2122 257301
Fax+2122 257364
712
Norway
Motek AS, Oslo
Phone+47 230 52 500
Fax+47 22 640 063
Oman
Bin Salim Enterprices LLC,
Hilti Division, Muscat
Phone+968 245 61708
Fax+968 245 61193
Pakistan
HSA Engineering Products,
Hilti Division, Islamabad
Phone +92 51 2215 462
Fax+92 51 2215 463
Romania
Hilti Romania S.R.L., Otopeni
Phone+40 213523000
Russia
Hilti Distribution Ltd., Moscow
Phone+7 495 792 52 52
Fax+7 495 792 52 53
Rpublique de Djibouti
Les Etablissements TANI, Djibouti
Phone +235 35 03 37
Fax+235 35 23 33
Saudi Arabia
Saad H. Abukhadra & Co.,Hilti
Fastening Systems, Jeddah
Phone+9662 6917700
Fax+9662 6917479
1 / 2009
Hilti worldwide
Senegal
Senegal-Bois, Dakar
Phone+2218 323527
Fax+2218 321189
Sweden
Hilti Svenska AB, Arlv
Phone+46 40 539 300
Fax+46 40 435 196
Ukraine
HILTI (Ukraine) Ltd., Kyiv
Phone +380 44 390 5566
Fax+380 44 390 5565
Serbia Montenegro
Hilti SMN d.o.o., Belgrade
Phone +381-11-2379-515
Fax+381-11-2379-514
Switzerland
Hilti (Schweiz) AG, Adliswil
Phone+41 844 84 84 85
Fax+41 844 84 84 86
Singapore
Hilti Far East Private
Ltd., Singapore
Phone+65 6777 7887,
Fax+65 6777 3057
Syria
Al-Safadi Brothers Co., Hilti
Division
Damascus
Phone+96311 6134210
Fax+96311 6123818
Slovakia
Hilti Slovakia spol. s r.o., Bratislava
Phone+421 248 221 211
Fax+421 248 221 255
Slovenja
Hilti Slovenija d.o.o., Trzin
Phone+386 1 56809 33
Fax+386 1 56371 12
South Africa
Hilti (South Africa) (Pty) Ltd.,
Midrand
Phone+2711 2373000
Fax+2711 2373111
Spain
Hilti Espaola S.A., Madrid
Phone+3491 3342200
Fax+3491 3580446
Sri Lanka
Hunter & Company Ltd.,Hilti
Division
Phone+941 12338 722-4
Phone+941 12328 171-5
Fax+941 12447 491
St. Lucia
Williams Equipment Ltd, Castries
Phone +1 758 450-3272
Fax+1 758-450-4206
St.Maarten, N.A.
Carfast Holding N.V., Cole Bay
Phone +599 544 4760
Fax +599-544-4763
Sudan
PEMECO INDUSTRIAL
SUPPLIES CO. LTD. Khartoum
Phone+249 15 517 5031
Fax+249 15 517 5032
1 / 2009
Taiwan
Hilti Taiwan Co., Ltd., Taipei
Phone+886 2 2357 9090
Fax+886 2 2397 3730
Tanzania
Coastal Steel Industrial Limited,
Hilti Division, Dar es Salaam
Phone+255 222865662
Fax+255 222865692
Thailand
Hilti (Thailand) Ltd.,
Bangkok Metropolis
Phone+66 2 751 4123
Phone-2-751 4127
Fax+66 2 751 4116
Trinidad and Tobago
Agostini's Fastening Systems Ltd.,
TT- Port of Spain
Phone+1 868 623 2236
Fax+1 868 624 6751
Tunisia
Permetal SA, Tunis C.U.N
Phone+216 71 766 911
Fax+216 71 766 807
Turkey
Hilti Insaat Malzemeleri Tic .A.S.,
Umraniye/Istanbul
Phone+90 216 528 6800
Fax+90 216 528 6898
USA
Hilti, Inc.,Tulsa
Phone (866) 445-8827
Fax 1-800-879-7000
Uruguay
Seler Parrado, S.A., Montevideo
Phone+598 2 902 3515
Fax+598 2 902 0880
Uzbekistan
BNZ Industrial Support, Tashkent
Phone +998 90 186 2792
Fax +99871 361
Venezuela
Inversiones Hilti de Venezuela, S.A.,
Caracas
Phone+58 -212-2034200
Fax+58-212-2034310
Vietnam
Hilti AG Representative Office,
Ho Chi Minh City
Phone+84 8 930 4091
Fax+84 8 930 4090
Yemen
Nasser Ziad Establishment, Hilti
Division, Yemen
Phone+9671 275238
Fax+9671 272854
Zambia
BML Electrical Limited, Kitwe
Phone+260 (2) 226644
Zimbabwe
Glynn's Bolts (Pvt.) Ltd., Harare
Phone+2634 754042-48
Fax+2634 754049
Turkmenistan
Zemmer Legal, Ashgabat
Uganda
Casements (Africa) Ltd., Kampala
Phone+25641 234000
Fax+25641 234301
713