Professional Documents
Culture Documents
FREQUENCY ANALYSIS
A. NATURAL FREQUENCY
fn
Kf
U 2
B. STROUHALL FREQUENCY
fw 2.64
V
T
C. MAGNIFICATION FACTOR
fw
fn
FM
r2
1 r2
STRESS ANALYSIS
A. MAXIMUM PRESSURE
P max K1 S
Note: satisfactory, if P
max
> P operation
Lmax
K 2 v ( S K 3P )
V
1 FM
Where:
fn : Natural frequency of the well at use temperature, cycles per second
U : Length of well, Inch (Refer to thermowell sketch at calculation sheet).
E : Modulus of elasticity of well material at use temperature, Psi. - Refer to Attachment 1
: Specific weight of well material at use temperature, Psi. - Refer to Attachment 1
Kf : A constant obtain from ASME PTC 19.3.74, Table 1.4
fw : Wake frequency, cycles per second.
V : Fluid velocity, fps.
T : Diameter at tip, Inch
FM : Magnification factor, dimensionless
r : Frequency ratio
P : Maximum allowable static pressure, Psi.
S : Allowable stress for material at use temperature, Psi.
Po : Static operating gauge pressure, Psi.
v : Specific volume of fluid, ft3/lb.
Lmax : Maximum value of U for a given service, Inch.
K1, K2, K3 : Stress constant obtain from ASME PTC. 19.3.74
Project:
Client:
P&ID No.
Line No.
Revision:
Date:
Tag Number:
Services:
FLUID DATA
CONSTANTS
Fluid
Operating Temp
Operating Pressure
Specific Volume @ T
Velocity
T
P
v
V
Liquid
180
1635
0.6510
8.2
82 F
111.2 psi
ft3/lb
2 fps
Kf
2.08
K1
0.412
K2
37.500
K3
0.116
CALCULATIONS
WELL DATA
Thermowell Length
Bore Diameter
Tip Diameter
Root Diameter
Specific Weight @ T
L
D
B
A
y
8.00
0.250
0.625
1.5
0.286
203.2
6.4
15.9
38.1
inch
inch
inch
inch
lb/in3
Mod of Elasticity @ T
Allowable Stress @ T
E
S
3E+07
30000
1.9E+06 psi
2040.8 psi
Natural Frequecy @ T
fn
320
Hz
Strouhal Frequency
fw
35
Hz
Frequency Ratio
Magnification Factor
Fm
Max Pressure
Max Length (r=.8)
P
Lmax
NOTES
1: Minimum root diameter =
0.8125
20.6375 inch
Satisfactory
0.625
15.875 inch
Satisfactory
0.254
6.4516 inch
Satisfactory
0.262
6.6548 inch
8:
These calculations are performed according to the requirements of ASME PTC 19.3. The result of this calculation shall be
considered as a guide only. The final result of the calculation shall be confirmed by selected Vendor at detail engineering
phase.
0.11
0.01
12360
634
841 psi
16106 inch