You are on page 1of 24

TD-LTE

Project

www.huawei.com
www.huawei.com

TD-LTE Power Configuration


Author/ Email: Ray Khastur
Version: V1.0 (20140106)

Basic Principle

How to Calculate RS

Kind of Symbol

PB Explanation

*PB 0 is mean there is no increment on CRS RE its mean non power boosting, but PDSCH power increase
to 5/4.
*By using PB 1, the RS Power increase on CRS RE two units its mean about power boosting and PDSCH
power on symbol type B same.
*By using PB 3, the RS Power increase on CRS RE 4 units its mean about power boosting and PDSCH
power on symbol type B
5
reduce half than PB 1.

Simulation Result

RSRP with PB : 1

RSRP with PB : 3

RSRP Comparison

is simulation one site have configuration of 10 MHz and all cells using RS Power 15.2 dBm with different PB configuratio

From Simulation single site there is no difference between PB 1 and PB 3


usage in coverage plot.
But from Power Consumption Calculation PB 1 will used around 10 W on each
port of RRU.
And For PB 3 will used around 5 W on each port of RRU.
9

SINR with PB : 1

10

SINR with PB : 3

11

SINR Comparison

From Simulation single site there is improvement of SINR > 0 dB around 3.65%

12

DL Throughput with PB : 1

13

DL Throughput with PB : 3

14

DL Throughput Comparison

From Simulation single site there is improvement of DL Throughput > 12.5


Mbps around 0.04 %
PB 3 in this simulation have 101.9 Kbps
more higher than PB 1 Average DL
Throughput.
But Peak Throughput still same at 28.17
Mbps

15

Using RS Power 18.2 dBm


with PB 3

RSRP

17

RSRP Comparison

RS : 15.2 dBm
PB : 1
Pwr : 10 W

RS : 18.2 dBm
PB : 3
Pwr : 10 W

s simulation one site have configuration of 10 MHz and all cells using different RS Power but with the same PB configura

18

SINR

19

SINR Comparison

From Simulation single site there is improvement of SINR > 0 dB around 9.51%

20

DL Throughput
Improve

Improve

Improve
21

DL Throughput Comparison

Compare with Average user Throughput for RS Power 15.2 dBm PB 1 which
have same power consumption, Average DL Throughput for 18.2 dBm PB3
have degraded 0.46% inside the polygon.
This degradation inline with the improvement of coverage outside the polygon.

22

Conclusion

Application of Power Boosting

Power Boosting can be used in order to manipulate limited of


power that can be used for single carrier coverage not more t
han half of capacity.

Implementation of Power Boosting (PB) can be applicable for


area where site to site distance is more than 800 meter for ou
ter area, and can be used also in inner area if the morphology
of that area is mostly dominated with High Rise Building, Den
se of Ruko (House with Commercial area) with more than 1 flo
or, this condition need additional site or we can use more pen
etration power with PB implementation.
24