You are on page 1of 1

SIZING CALCULATIONS FOR SUMP PUMP AT SUMP PIT FOR PROPOSED ERECTION OF A

2 STOREY DETACHED DWELLING HOUSE WITH BASEMENT AND SWIMMING POOL ON LOT
1663T PARCEL B6A-5 MK 34 AT OCEAN DRIVE, SENTOSA COVE
CALCULATION OF DESIGN FLOW
Discharge Unit
Flow from reflective pool & rain water in basement

= 2.0 lit/sec(estimated)

Design flow rate

= 2.0 lit/sec

CALCULATION OF STATIC HEAD


Discharge level at open drain
Sump pit level

=
=

103.35
99.97

Static Head

3.38

CALCULATION OF TOTAL HEAD


No. of dia. 50mm fittings

Equivalent length (m)

Length of dia. 50mm pipe (approx)


90 deg. Elbow
6 nos. (6 x 2.3)
Gate valve
2 nos. (2 x 22)
Check valve
2 nos. (2 x 11.5)
Tee piece
1 no

=
=
=
=
=

Total equivalent length of 50 dia. mm pipe

Flow Rate (lit/min)

5.56
13.80
44.00
23.00
3.50
89.86

50

100

150

200

Static Head (m)


Friction Head 50mm dia.

3.38
0.49

3.38
1.62

3.38
2.70

3.38
5.39

Total Head (m)

3.87

5.00

6.08

8.77

Pump selection
From the plot of system curve against pump performance curve:Pump selected : Nocchi submersible pump model Priox 300/9 M Aut
Capacity
Operating Head

:
:

2.0 lit/sec
6m