Professional Documents
Culture Documents
C Series DC motors
Grandezze-Sizes 7 23
Catalogo Catalogue
Code C-DC-ATEX-7-23-E-11
C Series
General
Flameproof DC motors C Series had been expressly designed for a fully reliable operation and in conformity of safety
prescriptions as requested by the regulation in force for electrical installations in dangerous environments.
The motors are certified by CESI (Centro Elettrotecnico Sperimentale Italiano ) according to the Directive 94/9/CE (ATEX) for
the following execution:
Group
:
II (not mine)
Category
:
2 (high protection)
Type of explosive atmosphere
:
G (gas, steams, smokes)
Execution
:
EX d II B with class of temperature T3 for duty from S1 to S9
Degree of protection
:
IP55 (according to IEC 34-5)
Motor design
Standards
Supply
Insulation
Temperature rise
Ambient temperature
:
:
:
:
:
Altitude of installation
Max. skin temperature
Balancing
Type of cooling
Degree of protection
Mounting
Main terminal box
:
:
:
:
:
:
:
IEC 60034
3-phase, 1-phase, batteries, Ward-Leonard group, chopper
Class H
Class H, F, B
-20C - +40C
Minimum stocking temperature: -40C
Maximum working temperature (with derating): 60C
1000masl max (up to 4000masl with derating)
+200C (class of di tempera ture T3)
class G2,5 (ISO 2373)
IC411 ( IEC 34-6: self ventilated totally enclosed motor, frame externally cooled)
IP55 (IEC 34-5)
according to IEC 34-7
at left side, viewed from DE
Options available
Thermoprotectors (NC contact)
PTC thermal protector
Pt100 thermistors
Tachometer (explosion-proof type)
Pulse generator (explosion-proof type)
Anticondensation heater (excluding frame C7)
Tropicalization of windings
Brush wear control device (excluding frame 7)
Drive End
Non-Drive End
Grease type
6204-2Z-C3
6205-2Z-C3
6307-2Z-C3
6308-2Z-C3
6310-2Z-C3
NU313-C3
6203-2Z-C3
6205-2Z-C3
6306-2Z-C3
6307-2Z-C3
6308-2Z-C3
6310-2Z-C3
Bearing lubrication
Grease q.ty (g)
Bearing re-greasing intervals (h)
DE
NDE
DE
NDE
30
20
6500
7000
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 2 of 12
C Series
CESI Certificates
Frame
size
C7
C 7C
C 11
C 13
C 16
C 19
C 19H
C 23
Execution
+
Class of Temperature
II 2G Exd IIB T3
II 2G Exd IIC T3
II 2G Exd IIB T3
II 2G Exd IIB T3
II 2G Exd IIB T3
II 2G Exd IIB T3
II 2G Exd IIB+H2 T3
II 2G Exd IIB T3
Motor
Certificate No.
Extension
Certificate
01/08
01/08
01/08
01/08
01/08
02/08
02/08
01/08
General prospectus for C Series motors according to ATEX Std (CEI EN 60079-0:2006/07 and CEI EN 60079-1:2005/11)
Group
Category
Type of atmosphere
Motor type
Execution
Class of surface temperature
Cooling type (IEC)
Cooling type (SICMEMOTORI code)
Degree of protection (IEC)
Minimum working temperature
Maximum working temperature
Maximum armature voltage
Maximum armature current (up to
40C ambient temperature)
Maximum armature current (for
60C ambient temperature)
Maximum motor power
Maximum motor speed
Temperature rise class
Nr. and max section of cables from
armature to terminal board
Terminal board installed into the
terminal box
Terminal box entry cable
Auxiliary terminal box entry cable
(for heaters, thermistors)
Nr. and theoretical section supply
cables into the terminal box
C7
Exd IIB
C7C
EXd IIC
II (not mines)
2 (high protection)
G (gas, steams, smokes)
C13
C16
Exd IIB
Exd IIB
T3
T3
IC411
IC411
CVEd
CVEd
55
56
-20 C
-20 C
+60C
+60C
500VDC
500VDC
T3
IC411
CVEd
55
-20 C
+60C
440VDC
C11
Exd IIB
T3
IC411
CVEd
55
-20 C
+60C
500VDC
18ADC
49ADC
49ADC
15,5ADC
43ADC
1,2kW
3600rpm
B or F
2,4kW
3000rpm
B or F
6x2,5mm2
T3
IC411
CVEd
56
-20 C
+60C
750 DC
C23
Exd IIB
T3
IC411
CVEd
55
-20 C
+60C
500VDC
86ADC
155ADC
200ADC
43ADC
76ADC
135ADC
175ADC
6kW
3000rpm
B or F
14kW
3600rpm
B or F
25kW
3200rpm
B or F
35kW
2500rpm
B or F
6x25mm2
C19
Exd IIB
C19H
Exd IIB+H2
6x50mm2
50x32 6 leds M4
70x45 6 leds M6
NPT
From M16x1,5 to M33x1,5
3x35mm2 + ground
3x70mm2 + ground
N/A
2
3x6mm + ground
Anticondensation heaters
Frame size
C7
C11
C13 up to C19
C23
Absorbed power
N/A
No. 1 x 42W
No. 2 x 42W
No. 1 x 99W
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 3 of 12
C Series
Output data
Motor selection for Three-phase fully controlled bridge supply ( by Single phase half controller bridge for (*))
Frame size
C7S*
C7M*
C7L*
C 11 S
C 11 M
C 11 L
C 13 S
C 13 M
C 13 L
C 16 S
C 16 M
C 16 L
C 19 S / HS
C 19 M / HM
C 19 L / HL
C 23 S
C 23 M
C 23 L
1000
0,1
0,12
0,16
0,56
0,72
0,9
1,5
1,9
2,3
3
3,5
4,3
5,6
6,7
8,3
10
12
15
1200
0,12
0,16
0,2
0,72
0,9
1,1
1,9
2,2
2,7
3,5
4,5
5,5
6,6
8,3
10
12
15
19,5
1500
0,16
0,2
0,25
0,9
1,1
1,3
2,2
2,8
3,4
4,2
5
6
8,4
10
12
15,5
20
24,5
Speed (rpm)
1800
0,2
0,25
0,3
1
1,25
1,5
2,8
3,4
4,2
5,2
6,2
7,3
9,8
12
14,5
19
23,5
28,5
2500
0,3
0,37
0,47
1,5
1,9
2,4
4,2
5
5,8
7
8,5
10,5
14
16
18,5
28
33
35
3000
0,35
0,45
0,6
1,75
2,2
2,8
4,8
5,8
7
8,7
10,5
12
3600
0,42
0,53
0,64
2
2,5
3
5,5
6,7
7,8
9,5
11,5
Power in kW
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 4 of 12
C Series
Output data
Motor selection for 110Vdc supply voltage by battery
Frame Size
C 7L
C 11S
C 11M
C 11L
C 13S
C 13M
C 13L
C 16S
C16M
C16L
C19S
C19M
C 19L
C 23S
C 23M
C 23L
C 7CL
1730
N/A
C 19HS
C 19HM
C 19HL
rpm
1820
N/A
at 40C
at 45C
at 50C
0,52
1,15
1,45
1,8
1,9
2,1
2,7
3,9
5,2
6,5
6,2
7,8
8,8
9,8
13,2
15,8
0,5
1,1
1,4
1,75
1,85
2,05
2,6
3,75
5
6,3
6
7,5
8,5
9,4
12,7
15,2
0,48
1,06
1,35
1,7
1,8
2
2,5
3,6
4,9
6,1
5,8
7,2
8,2
9,1
12,3
14,6
Absorbed
current at
40C
(A)
6,9
12,9
16
19,2
21,5
25,4
30
44,5
58,2
69
75
90,2
101
112
144
158
Nominal
torque
(Nm)
2,8
6,2
7,8
9,8
10
11
14,1
20,4
27,3
34,1
32,5
40,9
46,1
51,4
69,3
76,6
Efficiency
at full
load
(%)
65
78,2
80
83
78,6
75
74
78
80
84
74,2
78
78,2
78,7
82
83
Frame Size
C 7L
C 11S
C 11M
C 11L
C 13S
C 13M
C 13L
C 16S
C16M
C16L
C19S
C19M
C 19L
C 23S
C 23M
C 23L
rpm
C 7CL
1770
N/A
C 19HS
C 19HM
C 19HL
N/A
1870
at 40C
at 45C
at 50C
0,63
1,25
1,6
2
2,1
2,5
3,1
4,6
6
7,5
7,2
9,2
10,3
11,5
15,5
18,2
0,59
1,2
1,55
1,95
2,05
2,4
3
4,35
5,9
7,25
7
8,8
9,9
11,1
14,9
17,6
0,56
1,15
1,5
1,9
2
2,3
2,9
4,3
5,8
7
6,8
8,5
9,6
10,7
14,4
17
Absorbed
current at
40C
(A)
6,9
12,8
15,9
19,2
21,5
25,5
30
45
58
69
75
90
101
113
144
158
Nominal
torque
at 40C
(Nm)
3,4
6,9
8,8
11
10,7
12,8
15,8
20,4
30,6
38,3
36,8
46,9
52,6
58,7
79,2
92,9
Efficiency at
full load at
40C
(%)
69
75,7
78,5
82
77
79,5
81
80
82
86
76
80
80,6
81,4
85
91
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 5 of 12
C Series
Direct starting
C Series DC motors are not suitable for direct starting.
In case of battery fed motors, a 2-steps starting resistance must be connected in series with the armature circuit, in order to
reduce the starting current values within acceptable limits. The starting resistance must be connected during the motor starting
operation only, and it must be disconnected once the starting occurred.
As an example, a scheme of motor starting with connecting-disconnecting 2-steps starting resistance is given below.
Values of starting resistances are given in the table below (general information)
General information
Starting resistances ()
Item
Frame
size
C 7L
C 7CL
C 11S
C 11M
C 11L
C 13S
C 13M
C 13L
C 16S
C 16M
10
C 16L
11
12
13
C 19S
C 19HS
C 19M
C19HM
C 19L
C 19HL
14
C 23S
15
C 23M
16
C 23L
Note
Amb.
Temp.
110Vdc
125Vdc
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
50C
40C
2,5+2,5
2,2+2,2
1,4+1,4
1,25+1,25
1,2+1,2
1,1+1,1
1,0+1,0
0,95+0,95
0,96+0,96
0,90+0,90
0,80+0,80
0,76+0,76
0,70+0,70
0,65+0,65
0,48+0,48
0,45+0,45
0,37+0,37
0,35+0,35
0,32+0,32
0,30+0,30
0,29+0,29
0,27+0,27
0,24+0,24
0,23+0,23
0,22+0,22
0,20+0,20
0,20+0,20
0,18+0,18
0,16+0,16
0,15+0,15
0,14+0,14
0,13+0,13
3+3
2,6+2,6
1,65+1,65
1,5+1,5
1,4+1,4
1,3+1,3
1,2+1,2
1,1+1,1
1,1+1,1
1,05+1,05
0,96+0,96
0,87+0,87
0,8+0,8
0,75+0,75
0,55+0,55
0,5+0,5
0,42+0,42
0,4+0,4
0,36+0,36
0,34+0,34
0,33+0,33
0,31+0,31
0,28+0,28
0,26+0,26
0,25+0,25
0,23+0,23
0,22+0,22
0,21+0,21
0,18+0,18
0,17+0,17
0,16+0,16
0,15+0,15
Degree of protection
ATEX
ATEX IIB
IIB + H2 or
IIC
Armat.
Resist.
()
Rotor PD2
(kgm2)
(kg)
Noise
level at 1m
(dBA)
2,5
0,015
55
80
IP55
IP55
0,9
0,075
116
80
IP55
N/A
0,54
0,085
122
80
IP55
N/A
0,39
0,1
130
80
IP55
N/A
0,237
0,21
170
80
IP55
N/A
0,209
0,25
178
80
IP55
N/A
0,15
0,3
188
80
IP55
N/A
0,1
0,45
210
80
IP56
N/A
0,059
0,5
230
80
IP56
N/A
0,04
0,58
265
80
IP56
N/A
0,043
370
80
IP56
IP55
0,03
1,1
395
80
IP56
IP55
0,02
1,3
420
80
IP56
IP55
0,021
2,6
580
80
IP55
N/A
0,013
2,9
635
80
IP55
N/A
0,011
3,4
675
80
IP55
N/A
Weight
Tolerance +3 0 dB(A)
Sicme Motori Strada del Francese 130 10156 Torino Italy
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 6 of 12
C Series
MAIN TB
AUX TB
AUX TB
MAIN TB
SHAFT SECTION
AUX TB POSITION FOR C11 to C19
(if requested by purchase order)
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 7 of 12
C Series
(5.2)
B34:
B35:
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 8 of 12
C Series
Main Dimensions
Dimensions (mm)
Motor type
C7 / C7 C
L
S
M
L
S
M
L
S
M
L
S
M
L
S
M
L
C 11
C 13
C 16
C19 / C19 H
C 23
AA
AB
AC
AD
BB
C1
HA
HC
165
57
241
347
122
N.A.
117
224
10
60
304
455
164
143
108
160
10
325
14
279
70
337
498
164
152
121
180
12
375
14
318
70
382
542
250
163
133
212
22
465
18
356
90
446
685
243
176
149
225
18
485
18
457
120
545
722
273
175
228
260
304
249
287
325
278
317
355
346
371
416
440
491
529
74
254
140
178
210
254
203
241
279
228
267
305
286
311
356
368
419
457
190
190
280
22
580
22
Dimensions (mm)
S1 (6.1)
Motor type
L
C7 / C7 C
C11
C13
C16
C19 / C19 H
C23
Note
(6.1)
L1
540
540
S
M
L
S
M
L
S
M
L
S
M
L
S
M
L
620
645
675
721
751
786
810
845
885
872
912
957
1145
1190
1245
580
605
635
685
715
750
775
810
850
840
880
925
1145
1190
1245
S2 (6.1)
D
d1
(DIN332)
F
(h9)
GD
(h11)
19,05 j6
M6X16
62
4,57
16,43
4,57
22 j6
M8X19
50
18.5
28 j6
M10X22
60
24
32 k6
M12X28
80
10
27
8
7
8
48 k6
M16X36
110
14
42,5
M25x1,5
60 m6
M20X42
140
18
53
11
Tapered
Cylmetric
Tapered
Cylmetric
NPT 1
20x1,5
N/A
N/A
NPT 2
63x1,5
NPT 2
M20x1,5
NPT 2
NPT 2
75x1,5
Tapered / Cyl.-Metric
B55
TBH
TBA
TBB
TBH1
132
140
140
132
22,5
45
50
150
160
160
115
20
14
45
52
142
160
160
111
15
19
45
58
138
160
160
108
20
350
19
45
55
188
260
260
161
15
550
19
22,5
73
246
260
26 0
246
Fl. Size
LA
Holes
Nr
N.A.
15
149
114,31 j6
172
3/8 UNC
45
C 11
FF-215
14
215
180 j6
250
14
C 13
FF-265
14
265
230 j6
300
C 16
FF-300
15
300
250 j6
350
C 19 / C19 H
FF-300
13
300
250 j6
C 23
FF-500
22
500
450 j6
C 7 / C 7C
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 9 of 12
C Series
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 10 of 12
C Series
Examples of certificates
Sicme Motori Strada del Francese 130 10156 Torino Italy
C-DC-ATEX-7-28-E-11
Tel. +390114076311 - Fax +390114500047 www.sicmemotori.com sicmemotori@sicmemotori.com
page 11 of 12
C Series
Notes:
Customers can determine whether a specific product is suitable for their needs and are thus responsible for the selection, use
and results obtained by any product showed in this catalogue. The information contained in the present catalogue does not
guarantee the characteristics for the use.
The products listed in this catalogue are exclusively designed and built for industrial purposes.
For particular cases in NON-industrial environments, or where other types of protection must be provided (for example against
contact with children fingers, etc.), these guards or additional protections must be realized by the customer.
Any non-observance of the rules for installation, use and maintenance or any modification/tampering with the motor makes the
guarantee rights invalid and exempts SICMEMOTORI from any responsibility.
All data and indications shown in this catalogue have to be considered only as a guideline.
Any use of the motor differently from the specifications indicated in this catalogue does not involve any liability for
SICMEMOTORI as manufacturer.
SICMEMOTORI reserves the right to modify at any time and without notice the data, the technical characteristics, the
dimensions, the weights and the illustrations.
SICMEMOTORI refuses all responsibility for direct or indirect damages caused by possible errors and/or omissions in the
present catalogue.
The reproduction, even in part, of the present catalogue must be authorized in writing by SICMEMOTORI.
WARNING
The motors and the electrical devices feeding them are electrical components installed on machines and industrial
systems subject to high voltage. During operation, these components can be dangerous since they are live and have
non-insulated and rotating parts. Therefore, they can be extremely harmful to personnel and objects if the instructions
for the installation, the use and the maintenance are not respected.
The motors are always supplied complete with the installation, use and maintenance instruction manual. It is
necessary to read and understand all the information contained before proceeding to connect and to start up the
installation.
If the above mentioned documentation is lacking, please request a copy to SICMEMOTORI.
CAUTION
All information, data, drawings given in this catalogue are of a purely indicative nature and may be changed without
prior notice. SICMEMOTORI shall not be held responsible if the products illustrated herein are used outside their
limits of the specifications given.
12