SECOND FLOOR LIVE LOAD COMPUTATION - Frame B

From NSCP Section 205 Live Loads


Table 205-1 Minimum Uniform and Concentrated Live Loads

Span 1-2 - Corridor and Storage Room (Light)


3.8 Kpa (3m) + 6.0 Kpa (3.5m) = 32.4 Kn/m
Span 2-3 - Corridor and Restroom
3.8 Kpa (3m) + 2.4 Kpa (3.5m) = 19.8 Kn/m
Span 3-4 - Corridor
3.8 Kpa (6.5m) = 24.7 Kn/m
Span 4-5 - Corridor and Stairs
3.8 Kpa (3m) + 4.8 Kpa (3.5m) = 28.2 Kn/m
Span 5-6,6-7,7-8 - Corridor and Clothing Stores
3.8 Kpa (3m) + 4.8 Kpa (3.5m) = 28.2 Kn/m
Span 8-9 - Corridor
3.8 Kpa (6.5m) = 24.7 Kn/m
Span 9-10,10-11,11-12 - Department Store (Store-Retail)
4.8 Kpa (6.5m) = 31.2 Kn/m

Isolate Frame B

10

11

12

32.4Kn/m
31.2 Kn/m
28.2 Kn/m

24.7Kn/m

24.7Kn/m

19.8Kn/m

8.00

8.00

6.00

7.00

8.00

8.00

8.00

6.00

8.00

8.00

6.00