You are on page 1of 2

JOB TITLE:

JOB NO.:

SHEET NO.:

CALCULATED BY:

DATE:

CHECKED BY:

DATE:

3/23/2016

AASHTO-LRFD 2004 - CONCRETE SLAB & WALL DESIGN


LOCATION OF DESIGN SECTION:

Some Location

FLEXURE CHECK:

SHEAR CHECK:

Factored Moment, Mu =
Service Moment, Ms =
Concrete Strength, f'c =
Yield Strength, fy =
Total Depth, t =
Effective Width, b =
1st Bar Set Size =
1st Bar Set Spacing =
2nd Bar Set Size =
2nd Bar Set Spacing =
Average Bar Spacing =
Reinforcing Bar Area =
Clear Cover =
Effective Depth, de =

20.51
16.49
4.50
60.00
16.00
12.00
#6
8.00
None
0.0
8.00
0.66
2.625
13.00

k-ft
k-ft
ksi
ksi
in
in

Vu Max =
Mu @ Vu Max =
Shear =

15.55 kips
20.51 k-ft
0.9

b=12"

in

1st Bar Set

in
in
si
in
in

2nd Bar Set


t = 16"

Clr = 2.625"

Concrete Section
STRENGTH DESIGN CAPACITY:
=
=
a=

0.9
0.65
0.86

Mn = AsFy(d-a/2)
in

Mn =

37.33

k-ft

OK

As Max =

2.71

si

OK

1.2 x Mcr =
1.33 x Mu =

26.07
27.28

k-ft
k-ft

S5.7.3.3.2(a)
S5.7.3.3.2(b)

Mr =
Shrink. & Temp. Steel, As min. =
As Prov. =

37.33
0.35
0.66

k-ft
si
si

S5.10.8.2

MAXIMUM REINFORCING CHECK:


Max = 0.017404
MINIMUM REINFORCING CHECK:
S5.4.2.6
S5.7.3.3.2-1

fr =
S=

0.509
512

ksi
in^3

Mcr =

21.72

k-ft

Mr Lesser of:

OK
OK

CRACK CONTROL:
AASHTO LRFD 5.7.3.4:

Z1 = 170 for moderate exposure conditions,


Z2 = 130 for severe exposure conditions,

Allowable Stress in Reinforcing:


dc =
2.375
in
A=

Z(Input) =

38.00
133

k/in

Z3 = 100 for precast box culverts,


Z4 = 155/ for cast-in-place box culverts;
= 122.919 k/in
SHEAR CHECK:

fa =

29.655

ksi

Actual Stress in Reinforcing:


= 0.004
n=

7.50

n =

0.032

k=

0.222

j=
fs =

0.926
24.908
OK

ksi

Vu > Vc

Vc= 0. 0676

f ' c+ 4 . 6

As V u d e
bd e =
bd e M u

22.38

kips

OK