You are on page 1of 1

Design Review of BELSOT KHOLA BRIDGE Superstructure

1.Basic Design Data


Overall Span (C/C spacing of exp. joint)

Skew angle

Effective Span (C/C spacing of Bearing)


No. of Longitudinal Girders

C/C spacing of Longitudinal Girder


C/C spacing of Cross Girder

Distance between C/L of Brg. and C/L of Exp. Joint


Girder end to bearing centre line
Expansion gap

Transverse Cantilever length for Outer Girder


Width of deck

Clear Carriageway Width

Depth of Outer T-Girder


Depth of Inner T-Girder
Thickness of Deck slab

Thickness of Deck slab at expansion joint location


Thickness of end cross girder

Thickness of Intermediate cross girder


Grade of Concrete of Deck Slab
Grade of Concrete of Girder

Age of concrete for girder at transfer (1st stage Prestress)

=
=
=
=
=

42.5 m

40.000 m

0.00 Degree
3
3

10 m

1.25 m

0.450 m

2 m

=
=

0.04 m
10 m

7.5

2.5 m

2.5 m

0.25 m

0.4 m

=
=
=
=
=

0.4 m
0.3 m

40 Mpa
40 Mpa

7 days

80 %

Wearing coat thickness

0.065 m

Unit weight of Wearing Course

Maturity of concrete for girder at transfer (1st stage Prestress)


Strength of girder concrete at the time of transfer

Unit weight of Concrete

Contract No.:-BP-DB-069/070-06

=
=

32 Mpa

2.5 t/m3
2.2 t/m3

You might also like