This calculation covers the analysis and design of existing lifting


trunnion lug

The lifting trunnion is check based on two major conditions which are
consist of the stack totally in vertical position (90 degree) and also when
the stack totally in horizontal condition (0 degree).

We also calculated existing design with maximum withstand load with


several Safety Factor(SF)

Calculation - Existing Trunnion Lug


Design
Safety Factor (SF)

Allowable Stress for


stress Intensity

Max Withstand Load


(Tonne)

1.5

3.5

11

1.09

90%

34

New Trunnion Lug Design

Calculation New Trunnion Lug


Design
Safety Factor (SF)

Allowable Stress for


stress Intensity

Max Withstand Load


(Tonne)

1.5

0.9

38

New Trunnion Lug Design