Eccentric Footing Load & Moment Calculation(Middle Frame)

Middle Frame Reaction (From Steel Frame Structure)


Dead Load

8.484

kN

Collateral Load

5.22

kN

Roof Live Load

12.528

kN

Lateral Load (positive)

1.35

kN

Lateral Load(Negative)

1.35

kN

X Direction

Y Direction
Left Side (Wind)
WL1

20.648

WL2

13.448

kN

Right Side(Wind)
WR1
8.632

kN

kN

WR2

kN

Wall Load Calculation


Wall thickness

200

mm

c/c Distance between the wall

Height of Wall

Wall Finish Thickness

20

mm

Unit weight of block

16

kN/m3

Unit weigt of plain concrete

20

kN/m3

Total Wall Load

43.2

kN

SERVICE LOAD COMBINATION (FOOTING DESIGN )


1
2
3
4
5
6
7
8
9

1DL+1LL
1DL+1LL+1WX
1DL+1LL-1WX
1DL+1LL+1WY
1DL+1LL-1WY
1DL+1LL+0.714EQX
1DL+1LL-0.714EQX
1DL+1LL+0.714EQY
1DL+1LL-0.714EQY

69.432
103.528
35.336
79.496
59.368
70.3959
68.4681
70.3959
68.4681

kN
kN
kN
kN
kN
kN
kN
kN
kN

Load (P)

103.528

kN

Ultimate Load (1.5*P)

155.292

kN

Eccentricity (e)

120

mm

Moment (M)

1.5*P*e
18.63504

kN.m