ACER AL1916W does not boot repair process


ACER AL1916W does not boot. Disassemble measuring power high voltage integrated board 12V 5V no output.
After disconnecting the high pressure is also true. After investigation by the output of the two fast recovery diodes
to normal, the switch is normal. Measured voltage level bridge pile normal, large capacitance 300V . Measuring
power management chip DAP8A of 8 feet HV voltage of 50V , is significantly lower, and will DAP8A dismantle
voltage remains the same, then run the circuit, I found this HV voltage is 220V by 1K ohm after dividing draw with
diode rectifier, 1K minutes later resistive pressure of 50 multi- V , the 1K resistor put two parallel 5R5 resistance
(for fear of excessive current resistance burn easily, with two resistors in parallel). Change the resistance after the
HV get 220V voltage, but DAP8A of 6 feet VCC without power. Can not find this IC , DAP8A with 203D6 instead.
6 pin VCC voltage 8V hopping around, then checked the feedback, MOS pipe S pole a few 20 ohm resistor to
ground are infinite. Replace these few resistors, 6 feet VCC voltage not jump up. After the stage output 12V 5V
normal. This board repair.