The D pole of Q53 is controlled by VL5.At this time,open the bitmap(shown in figure 22-
19)
and ready to measure the voltage of each pin of Q53,but we found that Q53 is missing.
Find a small size of N channel field-effect tube to be installed,plug the power,and the standby
current is 0.03A,measure that VCC3M and VCC5M have produced.When this machine is in
standby,there is a voltage VCC1R5M,is measured to be 1.5V,which is normal.After triggering the
switch,lights normally,this machine is repaired.
Using the universal meter to test that the resistance value of the common point returned to be
normal,but when powered on to test,it is so bad.When CPU is not installed,the current jumps
repeatedly from 0V to 4V,then measured the voltage of the common point,it also jumps
repeatedly
repeatedly once powered on.Generally speaking,if the 3.3V rear stage is short circuit,it would
not
cause the common point jumping,so there may be noting wrong with 3.3V,we also need to
solve it
from the common point,but why 19V is normal when disconnects 3.3V.CPU power supply is
short
circuit first,so we also need to test it from CPU.By measuring,the diode value of the down tube
control level of CPU power supply is more than 400,but the diode value of the top tube PQ8804
is
more than 100.I see,replaced RT8856 directly,QFN chip of ASUS is difficult to weld,because the
reserved pin is too short.After welding,the current is also jumping,from 0V to 0.4V,but the
common point is not jumping.Measured CPU power supply,there is no voltage,then tested the
conditions of the CPU power supply chip,is shown in figure 22-22.
Measured that the 1 pin of RT8856 is 0V,the 2 pin is 3.3V,the 3 pin frequency setting
resistance is normal,6,8,9,10,11 and 12 are also normal,the 13 pin is 1.05V,there is no voltage
on
21 and 31 pin.It is strange,the chip has been replaced,the control level is normal,is the chip
broken?Replaced it again.After replacing,powered on,the current was not jumping,reached to
1.2A.For a moment,it was jumping from 0A to 0.7A again,measured the G pole of the field-
effect
tube,the G pole of the down tube PQ8806 and PQ8807 are 0What’s wrong,replaced RT8856
again,i need to check it carefully,can’t be powered on for a long time,used the oscilloscope to
measure that the rang of G pole of the top tube
PQ8804 is only 5V,so there is wrong with the
boosted circuit,replaced PC8811 directly,then
measured that the range of the G pole of PQ8804 is
normal.Powering on again,the current is
normal,connected the screen,ASUS is displayed.
Figure 22-23 the screenshot of the circuit
where PCIE_WAKE# is (This example is from http://www.chinafix.com/thread-720369-1-1.html
。 The origin
+3VSUS and +5VSUS,there is no voltage.In order to judge the problem quickly,turned off the
power
first,used the oscilloscope probe to click on the +5VSUS,then turned on the power,the
waveform is
shown in figure 22-24.the peak reaches to 5.8V,it is obviously wrong,is the over-voltage
protection.
This condition is usually caused by the filter capacitor,found the filter capacitor PCE8110 of
+5VSUS,is shown in figure 22-25.After replacing,the standby voltage is appeared.Then the
machine has repaired,i must to explain,some people will ask me,this fault is so easy,why you
uses
the oscilloscope to repair?Of course,if i don’t use the oscilloscope,i still can repair it,but if i use
it,for this fault,i don’t need to test the working condition of the chip or others,then i can find
the
problem immediately.
In practical maintenance,if the capacitor is not short circuit,it can be connected in
parallel
with a capacitor on the PCE8110,it can also solve the problem.The figure 22-26 is the
screenshot
of the description of the electrical features of the over-voltage protection threshold value of
this
machine’s standby chip RT8205.When the output voltage reaches to 115%(the maximum
value),then it is protected,that is 5*115%=5.75v.
Maintenance process:
uses the adjustable power supply with three bits,the current may be too small and can’t be
damaged,then measured each major power supply resistance,which are normal.Used the universal
meter to measure that the standby voltage is normal,the switch has the voltage.After pressing the
switch,when the current reached to 0.02A,the machine is powered off.Observed the current,the
voltage is not rising,opened the drawing and found that there is the voltage state diagram,is shown
in figure 22-27.
+3V_S5 and +5V_S5(the standby voltage of PCH) first,these two voltages are produced by PQ57
and PQ15,is shown in figure 22-28.These two MOS tubes are controlled by S5_ON sent by EC.
normal,which indicated that EC has sent S5_ON signal.But measured +3V_S5 and +5V_S5,there
is no voltage.This shows that the problem should be in the conversion circuit,or in the MOS tube
Measured that the voltage of the 4 pin of PQ15 is only 0.9V,it should be about 13V