Professional Documents
Culture Documents
AS1289.6.3.2
Client
Project
Location
Operator
Date
Job #
Lab #
Site #
Location
Site #
2
Location
Depth
mm
Blows /
100 mm
Est
CBR
Est
q(all)
Depth
mm
Blows /
100 mm
Est
CBR
Est
q(all)
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
4
3
3
3
3
2.5
3
3.5
5
8
6
8
9
14
16
8
6
6
6
6
3.5
6
6
10
15
12
15
15
30
35
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
115
80
80
80
80
70
80
80
150
240
180
240
270
420
475
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
1
8
13
8
6
4
4
4
5
10
2
15
25
15
12
8
8
8
10
20
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
40
240
390
240
180
115
115
115
150
300
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
#N/A
Geo-Eng Group
2451-01
Revision 0 10 Sept 01
0
0
0
0
12/30/1899
0
0
Site #
Location
Site #
Location
20
30
40
50
100
100
200
200
300
300
400
400
500
500
600
600
700
700
800
800
900
900
1000
1000
1100
1100
1200
1200
1300
1300
1400
1400
1500
1500
Est CBR (%)
De pth
De pth (m m )
AS1289.6.3.2
10
20
30
40
50
VicRoads Test Method 402.01 - Estimated California Bearing Ratio Using Dynamic
This method covers the calculation of the estimated California Bearing Ratio (CBR) of cohesive soils
the dynamic cone penetrometer described in AS 1289.6.3.2
Caution:
The CBR data derived using this method should be used with care and due considerati
condition at the time of the test in relation to that expected during service life of the pa
AS1289.6.3.2
0
0
0
0
12/30/1899
0
0
Site #
Location
Site #
BH2
Location
200
300
400
500
600
100
100
200
200
300
300
400
400
500
500
600
600
Depth (m m )
Depth (m m )
700
800
200
300
400
500
600
700
800
900
900
1000
1000
1100
1100
1200
1200
1300
1300
1400
1400
1500
1500
Allow able Bearing (kPa)
100
Note:
The Allowable Bearing Capacity data applies to cohesive soils only and is based on bearing capacity factor Nc = 5 and FOS = 4
Approximate Cu = 0.8 x allowable bearing capacity.
Caution:
The Allowable Bearing derived using this method should be used with care and consideration should be made of soil moisture
condition at the time of the test in relation to that expected during service life of the foundation.
Using DCP tests for determining soil strength and allowable bearing capacity is generally considered to be of limited applicability
(Ref Campanella & Robertson, 1983).
Blow per
100mm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
CBR
Bearing
2
3.5
6
8
10
12
12
15
15
20
20
25
25
30
30
35
35
40
40
50
50
50
50
50
50
50
50
50
50
50
40
70
80
115
150
180
220
240
270
300
330
360
390
420
450
475
500
530
570
600
600
600
600
600
600
600
600
600
600
600