DESIGN OF WIND LOAD

DATA
HEIGHT(h) = 5 m
WIDTH (w) = 6 m
LENGTH (L) = 8 m
VELOCITY (v) = 20 m/s
DESIGN AGE = 50 years
o
ROOF SLOPE = 15 - 22.5
SPACING OF TRUSS = 1220 mm
SPACING OF PURLIN = 610 mm
SAIZ OF RAFTER = 2"x 4"
SAIZ OF PURLIN = 1"x 2"
SAIZ OF ROOF BEAM = 2"x 4"
TYPE OF ROOF = Gable

PREASSUMPTION INPUT TAKEN FROM CP3


S1 = 1.0
S2 = 0.65
S3 = 1.0

CALCULATION OF WIND LOAD


Vs = V.S1.S2.S3
= 13 m/s
Dynamic pressure
q = 0.613Vs2
= 0.10 kN/m2
External pressure
h/w = 0.833
l/w = 1.333
p = Cpe.q
to wall α = 0 (From table 7)
= Surface A B
Cpe 0.7 -0.25
Pressure 0.073 -0.026

to roof angle = 30 (From table 8)


= Surface EF GH
Cpe -0.7 -0.5
Pressure -0.073 -0.052
Internal Pressure
p = Cpi.q
Cpi = 0.2
p = 0.021 kN/m2
A = 2.980 m2
F(EF) = (Cpe - Cpi) q . A
= -0.278 kN/m2
F(EF) = (Cpe - Cpi) q . A
= -0.216 kN/m2

0.278kN/m2 0.216kN/m2

Maximum wind pressure for this respective roof is 0.278 kN/m2