Check Software
Commissioning Quality

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


CONTENT
• Software Quality Standard List
• Quality Checking
Software Quality Standard List
Item Result
1 Check ODU received power value whether match with the plan.
2 Check ODU TX power value whether match the plan
3 Check ODU TX and RX frequency whether match the plan
4 Check IF working mode whether match the plan
5 Check 1+1 configuration
6 Check 1+1 switch state
7 Check NE ID and name setting whether match the plan
8 Check NE time whether synchronous with computer time
9 Check NE synchronous clock configuration
10 Check performance monitor state whether enabled
11 Check current and history alarm whether there are abnormal alarms

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


1. Check ODU received power value whether match
with the plan.
 The actual Rx Power value should within the plan designed receive value range according
to the customer’s requirement.

① ③

Plan Document

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


2. Check ODU TX power value whether match the
plan.
 The setting Tx Power value should equal to the plan designed transmit value.

① ③

The acceptable
value:
[25.5]

Plan Document

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


3. Check ODU TX and RX frequency whether match
the plan.
 The Tx Frequency and actual Tx Frequency should equal to the local site plan designed Tx
Frequency.

① ③

Plan Document

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


4. Check IF working mode whether match the plan.
 The IF Mode should be the same as the plan document.

① ③

Plan Document

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


5. Check 1+1 configuration.
 IF 1+1 configuration should correspond with the link design.


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8


6. Check 1+1 switch state.


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9


7. Check NE ID and name setting whether match the
plan.

② ③

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10


8. Check NE time whether synchronous with
computer time.
 The NE currently time should be synchronous with your computer clock, and synchronous
mode is NM.

① ③
The Same


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11


9. Check NE synchronous clock configuration.
 For RTN 620/610, it is necessary to configure synchronous clock.

① ③


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12


9. Check NE synchronous clock configuration.
 Typical mistakes:

5-IF 5-IF
RTN 620/610 RTN 620/610

Priority Internal Internal

Priority 5-IF; 5-IF;


Internal Internal

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13


10. Check performance monitor state whether
enabled.
 Check on the setting of enabling performance monitor, which is required to be enabled.

① ③


State: Enable. State: Enable.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14


11. Check current and history alarm whether there
are abnormal alarms.
 Browse current alarm, can’t exist critical and abnormal alarm.
 Browse history alarm , can’t exist critical and abnormal alarm during normal running time.
 For can’t handle alarm, please save it and require help.


③ ⑥

④ ⑤
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15
Thank you
www.huawei.com