TEST REPORT
Test Report # 597_ Date of Receipt: 29-03-2011 Name and address of Client: N/A Pool water sample Description of the sample: Item: Chemical analysis of Water Sample(s) Method Used/Statement of Compliance: APHA/AWWA/WEF (1998)

Measurement &Results: Parameters Method No. Units Water sample WHO Limits

pH Conductivity Total Dissolved Solids Total Hardness as CaCO3 Calcium as CaCO3 Magnesium as CaCO3 Total Alkalinity as CaCO3 Chloride as ClSulphate as SO4-2 Sodium as Na+1 Potassium as K+1 Nitrite as NO2-1

4500-H .B 2510.B 2540.C 2340.C 3500- Ca.B 3500-Mg. B 2320.B 4500-Cl.B 329 3500-Na 3500-K 4500-NO2-1

uS/cm mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L

7.7 1022 495 459 322 137 132 265 185 238 34 0.3

6.50-8.50 ___ 1000.00 500.00 250.00 150.00 500.00 250.00 250.00 200.00 75.00 0.10

Remarks /comments (where required):


On the basis of the above results chemically some parameters didnt lie within the permissible limits of WHO standards. Microbiological Examination is however also required to ascertain its portability

Tested by: Abdul samad (SR) Atif ali (ASR) Tufail Ahmed (Tech.)

Checked /Verified by ABDUL SAMAD