Professional Documents
Culture Documents
Suction Anchors in Clay
Suction Anchors in Clay
Suction Anchors
The best of all moorings!
1. Convention
Water
h
COG
L z
Soil z COG
t D
Possible forces: Total resistance of suction pile (Rd) Vertical load force (Td) (Submerged) Self weight caisson (W) Effective overburden pressure (P0) Penetration resistance (Qtot) Side shear along the side wall (Qside) The bearing capacity at the skirt tip (Qtip) Necessary underpressure (un)
Main parameters: - Water depth (h) - Pile or caisson length (L) - Pile or caisson diameter (D) - Pile thickness (t) - Penetration depth (z) - Center of gravity (CoG)
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.
22
Suction Anchors
The best of all moorings!
2. Soil conditions
For the calculation of the holding capacity or resistance R the most important variable is the DSS (Direct Simple Shear test) cyclic shear strength D,cy . With this the shear strength f between the pile and the soil can be determined. The cyclic shear strength is associated by the characteristic storm and the equivalent number of cycles it produces Neq. This can be done using an empirically determined graph. With the graph the value of
f ,cy
Su Su , D consisting of the average shear stress a divided by the static undrained shear stress Su.
a =
When having determined
S dz
u 0
z pile
f ,cy
Su
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.
33
Suction Anchors
The best of all moorings! In short, for the suction pile calculation in offshore clay the following variables are needed with their ranges: Cyclic DSS strength of the intact clay, D,cy f Plasticity index, Ip Static undrained shear stress, Su Soil sensitivity, St Effective unit weight of soil, Average shear stress, a 0 100 kPa 20% - 100% 5 100 kPa 1-8 9 11 kN/m3
The soil sensitivity St is a factor to show the strength of the soil after its been remoulded, determined from laboratory tests; Su St = Su ,remoulded The Plasticity index Ip is also determined in by laboratory tests and is determined by the difference between the liquid limit and the plastic limit of the soil.
3. Design
Limit state design
For the general design criterion is the following,
Where R is the design value of the resistance of the pile and T is the tension in the mooring line, both at the depth of the pad-eye; the connection point between the suction pile and the mooring line. The tension will be determined as follows:
Where
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.
44
Suction Anchors
The best of all moorings! In the following figure the case is described that, with horizontal loading, the tension in at the pad-eye TD(zD) differs from the tension at the dip-down point TD(zP).
Figure 4 - Change of tension and uplift angle between dip-down point and padeye depth.
The resistance is determined as follows: , where In this resistance the submerged weight of the suction pile is included and determined by the cyclic shear strength. The depends on the limit state; the ultimate limit state ULS or the accidental damage limit state. These are put in line in this table:
Table 1 the various factors depending on the limit state
The limit state design is a general requirement for calculating the eventual required resistance. As the process will be done by iteration, it is recommended to start with the preliminary design by means of rules of thumb.
Preliminary design
For the preliminary design, there are two rules of thumb for determining the dimensions suction pile in clay: L/d = 3 to 6 d/t = 100 to 250 Where L is the total length of the pile, d the diameter and t the wall thickness. The first rule of thumb is determined by the behavior of the suction piles with general soil properties of clay and the second by the elasticity and buckling ranges of the caisson.
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.
55
Suction Anchors
The best of all moorings! After assuming the variables, the bearing capacity can be calculated, knowing the soil conditions, and be compared to the maximum load on the suction piles. This is a process of iteration to achieve the desired results.
Set-up factor
The ratio between the shear strength at the interface between clay and outside skirt wall and the original shear strength is referred to as the shear strength factor or set-up factor:
With this factor, the determining shear strength for the bearing capacity calculation of the suction pile can be calculated. The set-up factor depends on the type of installation, as in penetration by self weight or by underpressure. For self weight penetration, the factor is determined as follows: The set-up factor in this case can be calculated by the following formulae, with a plasticity index of the clay of Ip>20%:
Where P0 effective overburden pressure Su static undrained shear stress The effective overburden pressure is the overburden pressure (=gz) minus the pore pressure at the depth. P0 ' = grain , wet gz water gz pile = grain , dry gz pile The self weight penetration depth will be determined later.
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.
66
Suction Anchors
The best of all moorings! For penetration by underpressure, the set-up factor will be calculated using the method described below. Here, the set-up factor needs to be determined by an empirically determined table, depending on the plasticity index Ip and the soil sensitivity St of the clay:
The surface of the skirt is on the outside of the skirt over the self weight penetration depth. The set up factor that is used is the one calculated earlier for the self weight penetration.
The surface of the skirt Askirt is on the outside of the skirt over the penetration depth.
4. Installation
For installation there are two types or phases; self weight penetration and installation by underpressure. In general, a suction pile will be installed with two methods combined. The pile will penetrate first into the soil by its own submerged weight where after the pumping installation will penetrate. In this case the bearing capacity will be calculated by the method of the underpressure.
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.
77
Suction Anchors
The best of all moorings!
Where: Awall skirt wall area (sum of inside and outside) Atip skirt tip area shear strength factor or set-up factor (normally assumed equal to the inverse of the sensitivity; if the skirt wall is painted or treated in other ways, this must be taken into account in the -factor) av Su , D average DSS shear strength over penetration depth
Suavtip ,
' Nc z
average undrained shear strength at skirt tip level (average of triaxial compression, triaxial extension and DSS shear strengths) effective unit weight of soil bearing capacity factor, plane strain conditions skirt penetration depth
The bearing capacity factor Nc varies from 6.2 to 9, calculated by the following formula:
The average DSS shear strength over penetration depth SuavD and the average undrained , shear strength at skirt tip level can be calculated using:
av u,D
D f , cy
dz
and
zswpd
Suavtip = ,
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.
88
Suction Anchors
The best of all moorings!
Installation by underpressure
For installation by underpressure, the most important variable is the required underpressure. The necessary underpressure un, needed for the finalization of the installation or penetration, depends on the self weight penetration depth and the total resistance for the penetration Qtot:
Where: W submerged weight during installation Ain plan view inside area of the pile where underpressure is applied
T.T. Bakker, M.A. de Heer, A.E Heerema,P. Smeets; Offshore Engineering; TU Delft, 2006 The use of the information of this document is at the own risk of the user/reader. The persons mentioned above assume no responsibility for the accuracy of the information provided in this document.