ULTRATECH CEMENT LTD

UNIT: ULTRATECH CONCRETE

SIEVE ANALYSIS TEST REPORT

Material

: 12.5mm

05-12-2011

Is Sieve
Size
In MM

Total Weight
Retained
In gms

% of Weight
Retained
In %

Total % of
Weight
Retained
In %

Cumulative
Weight
Passing
In %

16 MM

0.00

100.00

100

12.5MM

421

421

8.42

91.58

90.0 - 100.0

10MM

2316

2737

54.74

45.26

40.0 - 85.0

4.75MM

2245

4982

99.64

0.36

0.0 - 10.0

Pan

18

5000

100.00

0.00

0.0

Total

5000

IS Limits

ULTRATECH CEMENT LTD


UNIT: ULTRATECH CONCRETE

AGGREGATE IMPACT VALUE TEST REPORT

Material

: 12.5mm

05-12-2011

Original
Weight Of
material
(in gms)

Weight of
material
retained on IS
2.36 Sieve (in
gms)

Weight of
material Passing
on IS 2.36 Sieve
(in gms)

AIV (in %)

C/A x 100

374

295

79

21.12

374

291

83

22.19

354

273

81

22.88

Sample
No.

Average
(in %)

Specific
Limit

22.06

Maximum
35%

ULTRATECH CEMENT LTD


UNIT: ULTRATECH CONCRETE

SIEVE ANALYSIS TEST REPORT

Material

20mm

05-12-2011

Is Sieve
Size
(In mm)

Weight
Retained
(In gms)

Cumulative
Weight
Retained
(In gms)

Total % of
Weight
Retained
(In %)

Cumulative %
of Weight
Passing
(In %)

IS Limits
(In %)

25mm

100

100

20mm

521

521

10.42

89.58

85.0 - 100.0

16mm

2994

3515

70.30

29.70

10.0 - 30.0

10mm

1053

4568

91.36

8.64

0.0 - 20.0

4.75mm

419

4987

99.74

0.26

0.0 - 5.0

Pan

13

5000

100.00

0.00

Total

5000

ULTRATECH CEMENT LTD


UNIT: ULTRATECH CONCRETE

SIEVE ANALYSIS TEST REPORT

Material

: M SAND

05-12-2011

Is Sieve
Size
(In mm)

Weight
Retained
(In gms)

Cumulative
Weight
Retained
(In gms)

Total % of
Weight
Retained
(In %)

Cumulativ
e % of
Weight
Passing
(In %)

IS Limits
(In %)

10mm

100.00

4.75mm

95

95

4.75

95.25

90.00-100.00

2.36mm

390

485

24.25

75.75

75.00-100.00

1.18mm

275

760

38.00

62.00

55.00-90.00

600mic

440

1200

60.00

40.00

35.00-59.00

300mic

503

1703

85.15

14.85

8.00-.30.00

150mic

274

1977

98.85

1.15

0.0-10.00

Pan

23

2000

100.00

0.00

0.0

Total

2000

Remarks

Confirms to
the
gradation of
zone II as
per IS3831970
(reaffirmed
in 1990)

ULTRATECH CEMENT LTD


UNIT: ULTRATECH CONCRETE

SIEVE ANALYSIS TEST REPORT

Material

: RIVER SAND

19-08-2011

Is Sieve
Size
(In mm)

Weight
Retained
(In gms)

Cumulative
Weight
Retained
(In gms)

Total % of
Weight
Retained
(In %)

Cumulativ
e % of
Weight
Passing
(In %)

IS Limits
(In %)

10mm

100.00

4.75mm

118.00

118.00

5.90

94.10

90.00-100.00

2.36mm

372.00

490.00

24.50

75.50

75.00-100.00

1.18mm

323.00

813.00

40.65

59.35

55.00-90.00

600mic

372.00

1185.00

59.25

40.75

35.00-59.00

300mic

635.00

1820.00

91.00

9.00

8.00-.30.00

150mic

158.00

1978.00

98.90

1.10

0.0-10.00

Pan

22.00

2000.00

100.00

0.00

0.0

Total

2000

Remarks

Confirms to
the
gradation of
zone II as
per IS3831970
(reaffirmed
in 1990)

You might also like