13 MW Steam Turbine 50 Hz new Type : Multistage, impulse, uncontrolled extraction cum condensing Casing split : Horizontal Rotor type

: Solidly forged & machined rotor with integral disks Shaft seal : Labyrinth No. of governing valves : four Bearing support : two pedestals Rated speed : Turbine / Alternator 6000/1500rpm Total inlet flow max. : 60 TPH Condensing flow : 7 - 50 TPH Extraction flow / pr. / temp. : 0 52.7 TPH / 4.6bar @202~219 deg. C Max. Capacity power : 13.157 MW Design inlet steam Pressure : 48.0 Kg/cm2 (g) Design inlet steam temp. : 460 deg. CGENERATOR Generator shall be a three-phase brush less synchronous turbo-alternator of four poles with circulating air cooling via water cooler(SS Tube), with foundation parts and with two slide bearings. Type : QFW-12-4 (Brushless) Active output : 12000kW Rated current : 787.3A Rated voltage : 11000 10%V Rated speed : 1500min-1 Phase connection : 4Y Frequency : 50Hz +/- 5% Price: 2.45 Million USD with all warranties - delivered FOB to next sea port. The STG Set is already manufactured & packed in wooden containers. 30 MW Steam Turbine Make G.E.C. Parsons Year of manufacture 1965 66 Type Axial Flow Maximum Economical Rating 24 MW Maximum Continuous Rating 30 MW Capacity ( in kVA) 37,500 kVA Main Steam Pressure 900 p.s.i.g. Temperature 482C (900F) Circulating Water Temperature 15.5C (60F) Speed 3000 RPM Rotation viewed from front (Governor) end Counter-clockwise Alternator: Make G.E.C. Parsons Year of manufacture 1965 - 66 Capacity ( in kVA) 37,500 kVA Rated Stator Voltage 11,000 Volts Rated Stator Current 1970A Phases 3

Speed 3000 RPM Cycles/sec. 50 Power Factor .8 lag. Price 1 Million USD 55 MW and 60 MW 50 Hz Coal fired Powerplant Generator Unit 1 Unit 2 Rated output 62500/50000KVA/KW 75000/60000KVA/KW Rated voltage 10500V 6300/10500V Rated current 3440A 6873/4124A Production Date 1994.6 2004.12 Operation Date 2003.2 2005.1 Decommissioning date 2007.10 2007.10 Steam Turbine Unit 1 Unit 2 Rated output 50MW 60MW Rated speed 3000r\min 3000r\min Inlet pressure 8.83MPa 8.83MPa (88.3 Mpa) Inlet temperature 535 535 The 50mw unit has operated 39500 hours safely since 2003-2-26. The 60mw unit has operated 23320 hours safely since 2005-1-26 Price 29 Million USD for the plant - duly dismantled, packed & delivered FOB Nearest Seaport 35 MW CONDENSING STEAM TURBINE Type Condensing Capacity 35,000 kW Inlet steam pressure 1290 psig (87.93 bar) Inlet steam temperature 925 deg. F (496.11 C) Inlet steam flow 230,000 lb/hr (104.326 ton/hr) Exhaust pressure 1.5" HgA (0.05 bar) Speed 3600 rpm GENERATOR Model 6A3 Capacity 43,000 kVA Power Factor 0.85 Voltage 13.8 kV Speed 3600 rpm Frequency 60 Hz Features Specifications:100 MW PowerPlant Power Stations For Sale : Used 1x100 MW Coalfired PowerPlant Firing : PF CoalFired Boiler capacity: 900000 LBS PER Hour Pressure : 90 Bar Temp: 518 Deg.C Turbine : 100 MW 50 hz, Volts

SST-500 up to 100MW The SST-500 is a single-casing turbine, geared or with direct drive. It is suited to both generator and mechanical drives to accommodate large volume flows. Typically used as low-pressure casing in two-cylinder applications. Technical data Power output up to 100 MW Inlet pressure up to 30 bar / 435 psi Inlet temperature up to 400 C / 750 F Rotational speed up to 15,000 rpm Bleed up to 2, at various pressure levels Exhaust area 2 x 0.175 3.5 m2 / 2 x 1.9 24.8 sq. ft. Typical dimensions Length 19 m / 62 ft. Width 6 m / 20 ft. Height 5 m /16.4 ft. Features Double-flow condensing turbine Standard turbine modules, modular peripherals Throttle-controlled Highly customized Customized steam path SST-400 up to 65MW The SST-400 is a single-casing turbine, geared for generator drive. It has a compact and flexible design with a high degree of standardization. Used for industry and power generation applications. Technical data Power output up to 65 MW Inlet pressure up to 140 bar / 2,030 psi Inlet temperature up to 540 C / 1,005 F Rotational speed 3,000 8,000 rpm Controlled extraction up to 45 bar / 655 psi and up to 450 C / 840 F Bleed up to 60 bar / 870 psi Exhaust pressure (back pressure) up to 25 bar / 365 psi Exhaust pressure (condensing) up to 0.3 bar / 4.4 psi Exhaust area 1.3 3.0 m2 / 14.0 32.5 sq. ft. Typical dimensions

Length 18 m / 59 ft. Width 8.5 m / 28 ft. Height 5.5 m /18 ft. Features Back pressure / condensing type Pre-engineered turbine modules, modular peripherals Two controlled extractions, radial / axial exhaust Adaptive stage up to 16 bar Semi-package unit design Customized steam path Short delivery time SST-600 up to 100MW The SST-600 is a single-casing turbine, geared or with direct drive; suited to both generator and mechanical drives. Used for tailor-made applications for most complex processes in industry and power generation. Technical data Power output up to 100 MW Inlet pressure up to 140 bar / 2,030 psi Inlet temperature up to 540 C / 1,005 F Rotational speed 3,000 15,000 rpm Double controlled extraction up to 65 bar / 945 psi Bleed up to 5, at various pressure levels Exhaust pressure (back pressure) up to 55 bar / 800 psi Exhaust area 0.175 m2 3.5 m2 / 1.9 38 sq. f Typical dimensions Length 19 m / 62 ft. Width 6 m / 20 ft. Height 5 m /16.4 ft. Features Back pressure / condensing type Standard turbine modules, modular peripherals Inner casing for high steam parameters Second steam injection possible Package unit design Radial / axial exhaust Highly customized Customized steam path

Condensing Turbine (300MW)


Example of Installation:Philippines Turbine: Tandem Compound (2Casings), Double Flow, Reheat Type Output: 300MW Main Steam: 169 atg, 538C Reheat Steam: 538C Rotational Speed: 3600 rpm

Condensing Turbine (700MW)


Example of Installation: NANAO OHTA #2 POWER PLANT (Hokuriku Electric Power Co., Japan) Turbine: Tandem Compound (3 Casings), Four Flow, Reheat Type Output: 700MW Main Steam: 246 atg, 593C Reheat Steam: 593C Rotational Speed: 3600 rpm

Condensing Turbine (500MW)


Example of Installation: India Turbine: Tandem Compound (2 Casings), Double Flow, Reheat Type Output: 500MW Main Steam: 169 atg, 538C Reheat Steam: 538C Rotational Speed: 3000 rpm

Condensing Turbine (150MW)


Example of Installation: KAMAISHI #1 POWER PLANT (Nippon Steel Co., Japan) Turbine: Single Casing, Single Flow, Reheat Type Output: 149MW Main Steam: 169 atg, 566C Reheat Steam: 538C Rotational Speed: 3000 rpm

Condensing Turbine (1000MW)


Example of Installation: HEKINAN #4,5 POWER PLANT (Chubu Electric Power Co., Japan) Turbine: Tandem Compound (4 Casings), Four Flow, Reheat Type Output: 1000MW Main Steam: 246 atg, 566C Reheat Steam: 593C Rotational Speed: 3600 rpm

Condensing Turbine

Rated output: 38,000kW Main steam pressure: 2.9MPag Main steam temperature: 390C Exhaust pressure: 5.07kPa abs.

Reheat Turbine (axial-flow)


Suitable for combined cycle and low-floor installation plants For HP-EHC application

Rated output: 200,000kW Main steam pressure: 12.7MPag Main steam temperature: 538C Reheat temperature: 538C Exhaust pressure: 8.63kPa abs

Automatic-double-extraction Back-pressure Turbine


Rated output: 35,000kW Main steam pressure: 5.9Mpag Main steam temperature: 440C Extraction Pressure: 1.23/0.69Mpag Back Pressure: 0.27Mpag

Automatic-double-extraction Condensing Turbine


Rated output: 30,000kW Main steam pressure: 10.0Mpag Main steam temperature: 538C Extraction pressure: 1.18/0.59Mpag Exhaust pressure: 6.00kPa abs