You are on page 1of 12

ABS submersible sewage pump AFP 0831-2046

Robust, reliable submersible pumps from 1.3 to 30 kW for pumping wastewater and sewage from buildings and sites in private,
commercial, industrial and municipal areas in accordance with
EN 12050-1. Available as standard AFP or as higher specification
AFP(K).

Type tested
Text var

and monitored

Applications
AFP submersible pumps have been designed for the economic and
reliable pumping of clear or wastewater, gaseous liquids, and for
sewage and sludge, in fixed or portable applications.
* For fixed, wet well applications the AFP is pedestal mounted. Using a self-sealing coupling system the pump seals automatically
on the pedestal when lowered by guide rail into position.
* Dry well applications have the option of horizontal or vertical
installation.
* With vortex hydraulics the AFP is particularly suitable for sewage, abrasive matter, and fluids containing stringy materials that
tend to rope.
* The Contrablock hydraulic system offers higher efficiency and is
suitable for larger proportions of solid or fibrous matter.
Construction
The water-pressure-tight, encapsulated, fully flood-proof motor
and the pump section form a compact, robust, modular construction. Maximum allowable temperature of the medium for continuous operation is 40 C (information on applications at other
temperatures available on request).
Available in explosion-proof versions in accordance with international standards EExd II BT4, FM and ATEX.
Cooling
AFP: Free-circulation cooling by the medium.
AFP(K): Closed loop cooling system with circulation of glycol and
water which has no contact with the sewage being pumped. This
optimises heat exchange and avoids the danger of blockage of the
cooling system with sewage particles.
Dry installation is possible without cooling system, for intermittent
use only and subject to strict limitations.
Bearings
The stainless steel motor shaft is supported in lubricated-for-life
ball bearings.
Shaft sealing
Between the motor and hydraulic section is by means of a high
quality, silicon carbide, double mechanical seal. Standard AFP has
a single mechanical seal and upper lip seal. AFP(K) has the option
of double mechanical seals or a seal cartridge. The seal cartridge
combines both mechanical seals into a complete, easy-to-replace
unit (not available with ME motor). All seals are independent of
rotation direction and resistant to temperature shock.
Discharge
DN 80, 100, 150 and 200 DIN flange.
Temperature monitoring
TCS (Thermo-Control-System) with thermal sensors in the stator
to switch off the pump in the case of overheating and switch on
automatically after cooling down.
Seal monitoring
DI system consisting of a sensor in the motor and oil chambers
which signals an inspection alert if there is leakage at the shaft
seals (not in oil chamber on Ex version).
Hydraulics
AFP 0831-0835, 1031-1035, 1533: vortex, open, recessed, four-vane
impeller.
AFP 0841-0844, 1041-1049, 1541, 1543 & 2045: Contrablock, open
single-vane impeller.
AFP 1546 & 2046: Contrablock, open double-vane impeller.

Features
* High-efficiency hydraulic design using Contrablock or vortex
impellers.
* Available as standard AFP or higher specification AFP(K).
* AFP(K) has class H insulation and double mechanical seals as
standard, with options of seal cartridge and closed loop cooling
system.
* Automatic seal and temperature monitoring.
* Available as explosion-proof.
* Designed for fixed or transportable installation.
* For lifting, AFP has cast eyelet, AFP(K) has stainless steel lifting
hoop.
Motor
Three-phase, 400 V, 50 Hz, squirrel-cage motor as 2-pole (2900
r/min), 4-pole (1450) and 6-pole (980).
Protection type IP 68, with stator insulation Class F (155 C) for
standard AFP or Class H (180 C) for AFP(K) version.
Direct starting up to 3 kW; from 4 kW star-delta or direct starting
is possible. Motors with other operating voltages and frequencies
are also available.
Identification Code: e.g. AFP 1035.3 ME 250/2
Hydraulics:
AFP ........ Product range
10 ........... Discharge outlet DN (cm)
35 ........... Hydraulic number
.3 ............ Impeller
Motor:
ME ......... M = modular motor; E = high efficiency
250 ........ Motor power P2 kW x 10
2 ............ Number of poles

Materials
Description

Material

Motor housing

Cast iron EN-GJL-250

Motor shaft

Stainless steel 1.4021 (AISI 420)

Volute

Cast iron EN-GJL-250

Impeller

Cast iron EN-GJL-250

Bottom plate

Cast iron EN-GJL-250

Fasteners

Stainless steel 1.4401 (AISI 316)

AFP(K) options: stainless steel motor shaft 1.4401 (AISI 316), stainless steel impeller 1.4460
(AISI 329), viton seals, and surface hardened cast iron impeller and bottomplate.
AFP is available in SX version as a complete stainless steel pump (see separate literature).

Technical Data
AFP

Impeller
size

Solid
size
(mm)
80
80
80
80
80
80

Rated
voltage
(V)
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~

0831M 15/4
M 22/4
M 30/4
S 22/4
0832M 70/2
M 40/2

3, 4, 5, 6, 7
2
1
2, 3
1, 2, 3
4

0834M 110/2
0835M 55/2
M 70/2
M 110/2
0841M 15/4
M 30/4
S 22/4
S 13/4

Motor power *
(kW)
P1P2
2.511.95
2.882.20
3.953.00
2.882.20
8.377.00
4.864.00

Rated
current
(A)
4.65
5.15
7.00
5.15
13.60
7.93

Speed

Starting

(r/min)
1450
1450
1450
1450
2900
2900

DOL
DOL
DOL
DOL
Y
Y

1, 2, 3, 4

80

6
5
1, 2, 3, 4
1, 2, 3, 4
A
1
2, 3, 4

65
65
65
80
80
80
80

400 3~

13.3011.00

400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~

6.495.50
8.377.00
13.3011.00
2.511.95
3.953.00
2.882.20
1.931.30

22.10

2900

10.40
13.60
22.10
4.65
7.00
5.15
3.60

2900
2900
2900
1450
1450
1450
1450

0842M 40/2

50

400 3~

4.864.00

0844M 110/2
M 70/2

1
2

45
45

400 3~
400 3~

13.3011.00
8.377.00

7.93

2900

22.10
13.60

2900
2900

1031M 30/4
M 22/4
M 15/4

1
2
3, 5, 6, 7

100
100
100

400 3~
400 3~
400 3~

3.953.00
2.882.20
2.511.95

7.00
5.15
4.65

1032M 90/4
M 60/4
M 40/4

A
1
2, 3, 4

100
100
100

400 3~
400 3~
400 3~

10.809.00
7.226.00
5.004.00

1033ME 185/4
ME 160/4
ME 110/4
1034ME 250/2
ME 200/2
ME 185/2
ME 150/2
1035ME 150/2
ME 200/2
ME 250/2

1
2, 3
4
1, 2, 3, 4, 5, 6
1, 2, 3, 4, 5, 6
7
8
6, 7
5
1, 2, 3, 4

100
100
100
75
75
75
75

21.3018.50
18.2016.00
12.7011.00
28.4025.00
22.3020.00
20.4018.50
16.7015.00

64
64
64

400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~

1041M 30/4
M 22/4
M 15/4

1,2
3
4

90
90
90

1042M 90/4
M 60/4
M 40/4

A
1, 2
3

1043M 70/2

Cable
type **

Weight***

(a)
(a)
(a)
(e)
(b)
(b)

(kg)
78/90
79/90
80/92
45/n.a.
105/121
81/93

(b)

95/103

Y
Y
Y
DOL
DOL
DOL
DOL

(b)
(b)
(b)
(a)
(a)
(e)
(e)

117/130
117/130
129/142
78/90
80/92
56/n.a.
41/n.a.

(b)

81/93

Y
Y

(b)
(b)

110/120
100/110

1450
1450
1450

DOL
DOL
DOL

(a)
(a)
(a)

80/92
78/90
78/90

19.40
12.50
8.87

1450
1450
1450

Y
Y
Y

(b)
(b)
(b)

120/136
110/126
107/123

1450
1450
1450
2900
2900
2900
2900
2900
2900
2900

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

(c)
(c)
(b)
(d)
(c)
(c)
(c)

16.7015.00
22.3020.00
28.4025.00

36.50
32.00
22.10
44.60
35.00
32.30
27.10
27.10
35.00
44.60

(c)
(c)
(d)

290/320
285/315
280/310
240/270
230/260
225/255
220/250
222/250
227/255
232/260

400 3~
400 3~
400 3~

3.953.00
2.882.20
2.511.95

7.00
5.15
4.65

1450
1450
1450

DOL
DOL
DOL

(a)
(a)
(a)

80/92
78/90
78/90

100
100
100

400 3~
400 3~
400 3~

10.809.00
7.226.00
5.004.00

19.40
12.50
8.87

1450
1450
1450

Y
Y
Y

(b)
(b)
(b)

117/133
110/126
107/123

55

400 3~

8.377.00

13.60

2900

(b)

105/121

1045ME 220/4
ME 185/4
ME 160/4
ME 140/4
ME 110/4

A
1
2, 2B
2B
3

100
100
100
100
100

400 3~
400 3~
400 3~
400 3~
400 3~

24.7022.00
21.3018.50
18.2016.00
16.4014.00
12.7011.00

43.10
36.50
32.00
28.80
22.10

1450
1450
1450
1450
1450

Y
Y
Y
Y
Y

(d)
(c)
(c)
(b)
(b)

300/320
290/320
285/315
285/315
280/310

1048ME 250/2
ME 185/2
ME 150/2

1
2
3

50
50
50

400 3~
400 3~
400 3~

28.4025.00
20.4018.50
16.7015.00

44.60
32.30
27.10

2900
2900
2900

Y
Y
Y

(d)
(c)
(c)

250/275
245/270
240/265

1049M 90/4
M 60/4
M 40/4
1533ME 185/4
ME 160/4
ME 140/4
ME 110/4
1541M 90/4
M 60/4
M 40/4

A, 2
3
4
1
2
3
4
A
1, 2
3, 4, 5

80
80
80
100
100
100
100

10.809.00
7.226.00
5.004.00
21.3018.50
18.2016.00
16.4014.00
12.7011.00

1450
1450
1450

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

(b)
(b)
(b)
(c)
(c)
(b)
(b)

10.809.00
7.226.00
5.004.00

19.40
12.50
8.87
36.50
32.00
28.80
22.10
19.40
12.50
8.87

1450
1450
1450
1450
1450
1450
1450

100
100
100

400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~
400 3~

(b)
(b)
(b)

129/145
119/135
111/127
295/325
290/320
285/315
285/315
122/133
110/126
107/123

1543ME 220/4
ME 185/4
ME 160/4
ME 140/4
ME 110/4

A
1
2
2B
3

100
100
100
100
100

400 3~
400 3~
400 3~
400 3~
400 3~

24.7022.00
21.3018.50
18.2016.00
16.4014.00
12.7011.00

43.10
36.50
32.00
28.80
22.10

1450
1450
1450
1450
1450

Y
Y
Y
Y
Y

(d)
(c)
(c)
(b)
(b)

300/330
295/325
290/320
290/320
285/315

Electrical and cable data is for 400 V version only; data for alternative voltages available on request.
* P1 = power at mains; P2 = power at motor shaft

** Neoprene cable:

(a) 7G1.5
(b) 10G1.5
(c) 10G2.5

(d) 4G4 + 2x0.75


(e) 4G1.5 (4G1.5 + 3x0.75 for version with klixon)

*** without/with cooling jacket

Technical Data
AFP

Impeller
size

Solid
size
(mm)

Rated
voltage
(V)

Motor power *
(kW)
P1P2

Rated
current
(A)

Speed

1546M 90/4
M 60/4
M 40/4

A
2
4

75
75
75

400 3~
400 3~
400 3~

10.809.00
7.226.00
5.004.00

19.40
12.50
8.87

1450
1450
1450

2045ME 220/4
ME 185/4
ME 160/4
ME 140/4
ME 110/4

1
1
2
3
4

125x100
125x100
125x100
125x100
125x100

400 3~
400 3~
400 3~
400 3~
400 3~

24.7022.00
21.3018.50
18.2016.00
16.4014.00
12.7011.00

43.10
36.50
32.00
28.80
22.10

2046ME 140/6
ME 110/6
ME 90/6

1
2
4, 5

125x100
125x100
125x100

400 3~
400 3~
400 3~

16.1014.00
12.6011.00
10.409.00

28.80
24.00
21.40

Starting

Cable
type**

Weight***

Y
Y
Y

(b)
(b)
(b)

122/133
110/126
107/123

1450
1450
1450
1450
1450

Y
Y
Y
Y
Y

(d)
(c)
(c)
(b)
(b)

330/360
330/360
325/355
290/320
320/350

980
980
980

Y
Y
Y

(c)
(b)
(b)

330/360
325/355
325/355

(r/min)

(kg)

Electrical and cable data is for 400 V version only; data for alternative voltages available on request.
* P1 = power at mains; P2 = power at motor shaft

** Neoprene cable:

(a) 7G1.5
(b) 10G1.5
(c) 10G2.5

(d) 4G4 + 2x0.75


(e) 4G1.5 (4G1.5 + 3x0.75 for version with klixon)

*** without/with cooling jacket

Contrablock
The Contrablock impeller design ensures clog-free pumping combined with high-efficiency hydraulic performance.
It can handle solid sizes up to 125 x 100 mm, including fibres and fabric which can block conventional pumping systems.
1. Shearing ring on the upper shroud of the impeller to
protect the mechanical seal.

2. Open, single- or double-vane impeller with sloped


deflector edge at the impeller blade.

2
3
4

3. Large suction inlet.


4. Bottom plate with continuous spiral groove which
assists in transporting stringy material from the inlet
to the discharge.

5. Gap between bottom plate and impeller is easily


adjusted to restore efficiency in the event of wear.

AFP(K) cross-section

1. Stainless steel lifting hoop.


2. Motor shaft ball bearings with permanent
maintenance-free lubrication.

3. Motor with thermal sensors in each phase.


4. Stainless steel motor shaft.
5. Closed-loop cooling system with internal
recirculation impeller.
6. Seal-minder sensor for detection of moisture in oil
and motor chambers.
7. Seal cartridge unit with double mechanical seals.

6
7
5

8. Contrablock (featured) or vortex impeller.


8

Performance Curves

AFP 0832

AFP 0831
H [m]

13

H [m]

DN 80

12

30

26

11
M

30
/

10

M
22

/4

&

/4

&

15

S2
2/

5/4

0/
2

0
0

[m3/h]

20

10

15
40

20
60

25
80

30
100

120

[l/s]

[m3/h]

20

10

15
40

35

100

120

2
0

P2 [kW]

* Use only M-motor when fitted with cooling jacket

AFP 0834

AFP 0835

48

H [m]

DN 80

52

DN 80

48

44
M1

10/

40

36

M1

32

M11

M11

44

M1

40

M1
1

36

M1

32

M1

10
/2

10/

28

2 2

0/2

0/2

0/2

10

28

M5

20

0
0

5
20

10

15
40

25

20
60

80

[l/s]

Q [m /h]
3

12

12

4
0

12

16

12

[l/s]

0/
2

5/

20

Q [m /h]

/2
4

M7

24

16

/2

10

24

P2 [kW]

30

80

H [m]

25

20
60

P2 [kW]

M4

[l/s]

1
0

0/
2

/4

M1

10

15

/2

M7

12

15

/4

70

14

16

6
5

22

/2

M
70

18

4*

/4

24

20

4*

15

S2

2/

DN 80

28

P2 [kW]

20

15

10
40

25

20
60

80

H = Total HeadQ = Discharge VolumeP2 = Power at motor shaftCurves to ISO 9906N.B. Please use the ABSEL program to validate pump selection.

30
100

120

AFP 0841
H [m]

AFP 0842

15

H [m]

DN 80

14

32

28

13
M

30

26

/4

12

24

11

22

10

20

S2

2/

4&

18
M

15

/4

7
S1

15

3/

5
4

4&

/4

15

/4

S1

3/
4

&

M1

P2 [kW]

12
*

5/
4

10

6
*

4
2

0
0

[m3/h]

/2

1
[l/s]

40

14
4&

S1

16

3/

DN 80

30

10

15

25

50

20

25

75

30

35

100

40

125

150

45

[l/s]

Q [m /h]
3

P2 [kW]

20

10

15
40

25

20
60

80

30
100

35
120

* Use only M-motor when fitted with cooling jacket

AFP 0844
H [m]

AFP 1031

48

DN 80

44

M1
1

40

H [m]

13

DN 100

12
0/
2

11

10

36
M7

32

M3

0/

M2
2/

M1

24

5
16

12

0
0

5
20

10

15
40

20
60

30

25
80

100

[l/s]

Q [m /h]
3

P2 [kW]

P2 [kW]

/4

M1

5/4

M1
5

12

5/4

20

[l/s]

28

Q [m /h]

0/
4

M1

5/4

20

10
40

25

20

15
60

80

35

30
100

120

40
140

Performance Curves

AFP 1033

AFP 1032
H [m]

24

H [m]

DN 100

22

30

DN 100

28
26

20

24

18

22

M9
0/

16

0/4

185

/4

/4

ME1

10/

4 4

12

M4

0/4

8
M40

/4

160

14

M40

10

/4

ME

16

12

160

18

/4

ME

20

M6

14

ME

10
8

2
0

2
0

[l/s]
[m /h]
3

10

20

15

40

20

60

25

80

35

30

100

120

40

45

140

50

160

[l/s]

[m /h]

18

12

P2 [kW]

10

30

20
50

100

50

150

60

70

80

250

200

90
300

P2 [kW]

AFP 1034
H [m]

40

AFP 1035

65

DN 100

60

ME200/

x0

ME2

55

2 & 250/

45
40
35
30

DN 100

70
65

ME

60

ME

250

2 1

0/2 &

250/

ME20
0/2 &
250/2
ME2
00/2
& 25
0/2
ME2
00/2
& 25
0/2
ME2
00/2
& 25
0/2
ME1
85/2
7
ME1
50/2
8

50

H [m]

= max. flow
ME200

250

250

200

/2

ME

1
2

3
4
5

15

ME

0/2

150

35

25

/2

ME

40

/2

ME

45

/2

ME

50

250

55

/2

/2

6
7

30

20

25

15

20

10

15

10
5

[l/s]

Q [m /h]
3

24

20

10
40

25

20

15
60

80

35

30
100

120

40
140

[l/s]

Q [m /h]

16

30

0
0

10
25

15
50

20
75

25

30
100

35
125

20
8

P2 [kW]

10

P2 [kW]

H = Total HeadQ = Discharge VolumeP2 = Power at motor shaftCurves to ISO 9906N.B. Please use the ABSEL program to validate pump selection.

40
150

45

AFP 1041
H [m]

AFP 1042

15

H [m]

DN 100

14

30

DN 100

28
26

13

24
M3

12

0/

11
10

22

20

M3
0/

/4

M1

5/

0/4

M6

0/

16

22

M9

18

M6

M4

0/

12

0/

14

10

8
4

3
4
2
2
1

[l/s]

0
0

10

15

20

25

35

30

40

45

50

[l/s]

Q [m /h]

[m3/h]

20

40

60

80

100

120

140

160

10

30

20
50

100

40

50

150

60
200

70

80

250

90
300

3
6
2
3
1

P2 [kW]

P2 [kW]

AFP 1043
H [m]

AFP 1045

60

H [m]

DN 100

56
52

50

DN 100

45

48

40

44

ME

22
0/4
ME
A
185
/4
1
ME
160
/4
2
ME
140
/4 &
ME
ME
110
160
/4
/4
3
2B

35

40
36

30

32
M7

0/2

28

25
1

24

20

20
15

16
10

12
8

4
0
[l/s]

Q [m /h]

0
0
0

10
25

15
50

20
75

25

30
100

35
125

40
150

45

[l/s]

Q [m /h]
24

12

16

P2 [kW]

P2 [kW]

0
0

10

20
50

30
100

40
150

50

60
200

70
250

80

90
300

Performance Curves

AFP 1048
H [m]

AFP 1049

75

DN 100

30
[m]

DN 100

28

70

26

65

ME

25

0/

60

E1

50

/2

45

20

18

/4

/4

14

35

60

16

40

M
90
/4

E1

90

/2

22

85

55
50

24
1

40

/4

12
30
10

25

8
20

15
4
10
2
5

[l/s]

[m3/h]

24

P2 [kW]

0
0
0

10

20

15

40

20

60

25

80

35

30

100

120

40
140

45

50

[l/s]

[m /h]

160

10

30

20
50

100

P 2 [kW]

H [m]

DN 150

28

24
22

20

DN 150

20
ME1
85/4

ME1

16

60/4

ME14

0/4

14

ME1

10/4

12

1
2

16

M6

14

M6

10

10

20
50

30
100

40
150

50

60
200

70
250

80

90
300

100
350

[l/s]

Q [m /h]
3

12

0/

M4
0

/4

M4
0

/4
M4
0/
4

0
0

18

0/

12

10

M9
0/

18

10

20
50

1
2

30
100

40
150

50

60
200

70

80

250

P2 [kW]

H = Total HeadQ = Discharge VolumeP2 = Power at motor shaftCurves to ISO 9906N.B. Please use the ABSEL program to validate pump selection.

100
350

30

22

90
300

26

18

P2 [kW]

80

24

70
250

28

26

[l/s]

60
200

AFP 1541

30

Q [m /h]

50

150

16

AFP 1533
H [m]

40

90
300

100
350

AFP 1543
H [m]

AFP 1546

52

H [m]

DN 150

48

26

DN 150

24

44

22

40

20

36

18

32

16
M

E2

28

20
/

E1

20

ME

E1

/4

2B

/4

[l/s]
[m /h]
3

20

40

80

60

100

200

100

300

120
400

140
500

160

200

180

600

220

0
[l/s]

Q [m /h]
3

700

40

/4

20

24

12

16

P2 [kW]

60
/

10

12

10

E1

/4

16

/4

0/

90

12

60

14

24

14

85

40

80

60

100

200

120
400

140
500

160

180

600

200

220

700

P2 [kW]

AFP 2046

AFP 2045
H [m]

100

300

26

H [m]

DN 200

24
22

18

5/

ME

18

4&

16

22
0/
4

0/

E1

16

DN 200

24
22

ME

20

26

18

40

/4

20
1

16

14

14

ME

E1

10
/

12

140

12

/6

110
/6

ME

10

10

ME
90/

ME90

6 4

0
[l/s]

Q [m /h]
3

20

40
100

60
200

80
300

100

120
400

140
500

160
600

180

200
700

220

0
[l/s]

Q [m /h]
3

12

16

P2 [kW]

0
0

24

P2 [kW]

/6 5

20

40
100

60
200

80
300

100

120
400

140
500

160
600

180

200
700

220

Dimensions (mm)
AFP

DN1DN2ABCDEFGG1G2G3HJKLMN

0831

808016788340200250651275700256350100161162625210130

0832 M70/2
0832 M40/2

808016788340200250696275700256350100161162625210130
808016788340200250651275700256350100161162625210130

0834

808016788340200250746275700256350100161162625210130

0835
0835 M110/2

808016788340200265665280823323370136172172742242180
808016788340200265715280823323370136172172742242180

0841

8010016788340200240653270818325327115167141748252180

0842

8010016788340200240653270818325327115167141748252180

0844 M70/2
0844 M110/2

8010016788342200230689258787330300102154140729272218
8010016788342200230739258787330300102154140729272218

1031

10010018092370225250671310720305370115161162633220130

1032
1032 M90/4

10010018092370225250731323747320362113180180649222130
10010018092370225250781323747320362113180180649222130

1033

10015018092371225315115833078739147591252212682286204

1034

100100243984252492501104325725398370137180180649322210

1035 DN80
1035 DN100

801001801683702003001071290540358370135173173450268218
1001002431004252493001071339540358370184173173450268218

1041

1001001809237122526565827581731334490191160769269180

1042
1042 M90/4

1001001809237122526573128584534536774212168786286180
1001001809237122526578128584534536774212168786286180

1043

1001001809237122524072128582533031086168168764269180

1045

10015018092371225315114533078739147586252212682286204

1048

100100243984252492701077311516334320150172172454272218

1049
1049 M90/4

10010018092371225280717308831369370112214171748286218
10010018092371225280767308831369370112214171748286218

1533

150150210984632803351166383795423470136278220692320228

1541
1541 M90/4

15015021098463280310731340845345375129240190786286180
15015021098463280310781340845345375129240190786286180

1543

150150210984632803351153383795423470131278220692320228

1546
1546 M90/4

15015021098463280310731340845383370130240190786324218
15015021098463280310781340845383370130240190786324218

2045

2002002451355503204001192442834488470151328241712366254

2046

2002002451355503204001192442834488470151328241712366254

DN1 = Discharge, DN2 = Suction.Dimensions F, O, P, S measured from cast lifting eyelet available on request (for AFP-S and AFP without lifting hoop).

Wet well (pedestal)

14*

70

40

52

85

90

Minimum sump opening AFP 0831-0844, 1031, 1032, 1041-1043:


one pump = 700 x 700; two pumps = 700 x 1400

* For hexagon head wood screw


10x70 DIN 571 and dowel size 12.

Transportable

Minimum sump opening AFP 1033-1035, 1045-2046:


one pump = 1050 x 780; two pumps = 1050 x 1520

G2

M
U
T

Q
F

DN 1
W

E
DN 1

DN 1

18 **

X
K

** AFP 2045 & 2046 = 23 mm

DN 2

a
+

= Lowest switch-off point


for automatic control.

AFP

OPQRSTUWXYZabcdefghj

0831

117675534852565116020018161100235207+2527519545030011355575

0832 M70/2
0832 M40/2

122186634852569616020018161100235207+2527519545030011362175
117675534852565116020018161100235207+2527519545030011355575

0834

127191034852574616020018161100235207+2527519545030011366575

0835
0835 M110/2

13438455006786651602001817264235207+2527519545030011061075
13938955006787151602001817264235207+2527519545030011066075

0841

1287793425580707*16020018155167*200207+2527519536525011555272

0842

1287793425580707*16020018155167*200207+2527519536525011555272

0844 M70/2
0844 M110/2

1318862550652666*1602001814376*200207+252751953652509658972
1368912550652716*1602001814376*200207+252751953652509663972

1031

119676534852567118022518161110235230+2530021545030012357675

1032
1032 M90/4

126884134853773118022518180112235230+2530021545030013765575
131889134853778118022518180112235230+2530021545030013770575

1033

17061310682575113118022518231122310230+2530021554140012292993

1034

16411314520537110418022518180112235193-5726026045030013791275

1035 DN80
1035 DN100

1456127460538510711602001817365235200-481601604503009888772
1456127460538510711802251817365235193-572602604503009888772

1041

1295793500576719*18022518176194*235230+2530021545030013755675

1042
1042 M90/4

1366866440540826*18022518189246*235230+2530021545030015463275
1416916440540876*18022518189246*235230+2530021545030015468275

1043

1346851425581765*18022518168183*200230+2530021536525013161672

1045

16881292682575111318022518231107310230+2530021554140012291193

1048

1432125055037810541802251817276200193-572602603652509685772

1049
1049 M90/4

13528906056636891802251819335235230+2530021545030011662575
14029406056637391802251819335235230+2530021545030011667575

1533

17141342682575113924028523246117310272-1827027054140013293493

1541
1541 M90/4

1366866500540826*24028523215246*235272-1827027045030015463375
1416916500540876*24028523215246*235272-1827027045030015468375

1543

16961324682587110924028523246106310272-1827027054140013291993

1546
1546 M90/4

1366904605616750*24028523215171*235272-1827027045030015463975
1416954605616800*24028523215171*235272-1827027045030015468975

2045

17341389682567116729534023289144310300-13042034054140015295893

2046

17341389682567116729534023289144310300-13042034054140015295893

* Includes flange DIN 2633, PN 16;AFP 1546 includes 5 to DN150 adaptor flange.

Dry well vertical

Dry well horizontal


S
Y

G3
L

G1

Volute Support (horizontal installation)

= Lowest switch-off point


for automatic control

j
18

(1
e
K

(2

g
h
(1 = Centre of discharge line,(2 = Centre of head support

Accessories
Description
Pedestal* (cast iron EN-GJL-250)
90 cast bend - plug/clamp
connection (with fixing bolts)

90 cast bend - flange


connection (fixing bolts
not included)

flange connection without bend


(with fixing bolts)
Chain Kit (galvanized steel)
including shackle
Chain Kit (stainless steel)
including shackle

Fixed installation dry well, (horizontal)

Pump Support Kit (EN-GJL-250)


head and volute supports with
fixing bolts and vibration damper

Size
DN 80 (pipe 90 mm)
DN 100 (pipe 109 mm)

Part no.
62320650
62320653

DN 100 high head (109 mm)


DN 100 (pipe 115 mm)

62325020
62320654

DN 150 (pipe 160 mm)


DN 150 (pipe 169 mm)
DN 80
DN 100

62320656
62320657
62320649
62320652

DN 100 (high-head)
DN 150
DN 200
DN 80
DN 100
DN 150

62325019
62320655
62320658
62320517
62320516
62320537

3m
4m
6m
7m
3m
4m
6m
7m

61265065
61265093
61265069
61265096
61265081
61265099
61265085
61265102

0831-2046

61820025

0841/M, 0842,
0844, 1043
0831/M, 0832,
0834, 1031, 1041
1032, 1042,
1049, 1541, 1546
0831/S, 0841/S
1033, 1045, 1533
1543, 2045, 2046
0835, 1034, 1035
1048

61820040
61820041
61825001
61825007
61825008
61825009

(vertical)

Ground Support Stand

61355000
61355001
61355002
61355003
61355008
61355011

Transportable

Ground Support Stand

61350525

0831/M, 0832, 0834,


1031, 1032, 1034
0835, 1041, 1042,
1049, 1541, 1546
0831/S, 0841/S,
0841/M, 0842, 1043
1033, 1045, 1533,
1543, 2045, 2046
1035
0844, 1048

61355004
61355005
61355006
61355007
61355009
61355010
Non-return Valve (EN-GJL-250)
ball valve with inspection hatch

61400523
61400524
61400541

0831-0844
1031-1049
1533-1546

ball valve with inspection hatch


and venting screw

61400534
61400535
61400542

0831-0844
1031-1049
1533-1546

Gate Valve (EN-GJL-250)

61420500
61420501
61420503
61420504

0831-0844
1031-1049
1533-1546
2045 & 2046

61350527

* 2-inch guide rail not included

0831-2046

0831/M, 0832,
0834, 1031, 1032
0831/S, 0841/S,
0841/M, 0842, 1043
0835, 1041,
1042, 1541
1033, 1045
1035, 1049
1533, 1543
2045, 2046
1034
0844, 1048

61350526

General

AFP
0831-0844
1031-1033,
1041-1045, 1049
1034, 1035, 1048
1031-1033,
1041-1045, 1049
1533-1546
1533-1546
0831-0844
1031-1033,
1041-1045, 1049
1034, 1035, 1048
1533-1546
2045 & 2046
0831-0844
1031-1045, 1049
1533-1546

ABS submersible sewage pump AFP 0831-2046 GB 2009-08-10 | We reserve the rights to alter specifications due to technical developments.

Fixed installation wet well with ABS


Automatic Coupling
System

You might also like