You are on page 1of 2

DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF ENGINEERING AND TECHNOLOGY PESHAWAR.

CONCRETE LABORATORY TEST REPORT Test Name: Agency: Source: Name of Facility: Activity: Soundness Test of Coarse Aggregate (Sample # 01)
Zafar Mahmood Baloch, Ravi Construction Co. Test No: 0004/2013

Letter Received on: 11/1/2013 Sample Received on: 11/1/2013 Sample Testing Date: 15/01/2013
11/01/2013(as per letter

N.A N.A Project Shaukat Khanum Memorial Cancer Hospital.

Sample Collection Date:


No: SKMCH/Ravi/01)

Sieve Size

Gradation Wt. Retained, g (grams)

Percentage of Material

Wt. of Test Gradation of Fraction Original Sample, % Before Test, g

Percentage Passing Designated Sieve After Test

Weighted Percentage Loss

2 to 2 in 2 to 1 in 1 to 1 in 1 to in to in to 3/8 in 3/8 to No. 4 in

0 0 0 100 1000 1238 374

0 0 0 10.2405498 34.3642612 42.5429553 12.8522337

0
0

100

10.2405498

1.67785235

0.17182131

1330 300

76.9072165 12.8522337

4.81203008 1.333333333

3.70079839 0.17136312

Totals

100

100

4.04398282

Disclaimer: This Report states the result (s) of the test (s) performed on the materials as recevied by the laboratory from the above stated 'Agency'. Verfication, certification or acknowledgement of the origin or association of the material being tested to a particular project or site is beyond the responsibility of this department.

Testing Officer Concrete Laboratory University of Engineeing & Technology, Peshawar.

DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF ENGINEERING AND TECHNOLOGY PESHAWAR. CONCRETE LABORATORY TEST REPORT Test Name: Agency: Source: Name of Facility: Activity: Soundness Test of Coarse Aggregate (Sample # 02)
Zafar Mahmood Baloch, Ravi Construction Co. Test No: 0004/2013

Letter Received on: 11/1/2013 Sample Received on: 11/1/2013 Sample Testing Date: 15/01/2013
11/01/2013(as per letter

N.A N.A Project Shaukat Khanum Memorial Cancer Hospital.

Sample Collection Date:


No: SKMCH/Ravi/01)

Sieve Size

Gradation Wt. Retained, g (grams)

Percentage of Material

Wt. of Test Gradation of Fraction Original Sample, % Before Test, g

Percentage Passing Designated Sieve After Test

Weighted Percentage Loss

2 to 2 in 2 to 1 in 1 to 1 in 1 to in to in to 3/8 in 3/8 to No. 4 in

0 0 0 404 1144 706 556 2810.000

0 0 0 14.3772242 40.7117438 25.1245552 19.7864769

404

14.3772242

0.17793594

1330 300

65.83629893 19.78647687

0.90225564 1.333333333

0.59401172 0.26381969

Totals

100

100

1.03576735

Disclaimer: This Report states the result (s) of the test (s) performed on the materials as recevied by the laboratory from the above stated 'Agency'. Verfication, certification or acknowledgement of the origin or association of the material being tested to a particular project or site is beyond the responsibility of this department.

Testing Officer Concrete Laboratory University of Engineeing & Technology, Peshawar.