You are on page 1of 2

FT 3013

RESET E#5
M may , gat DIP Switch 101-1 tren MainBoard t Off --> On --> Off , tat roi m cong
tac chnh .

SERVICE CALL CONDITIONS


CODE #11 EXPOSURE LAMP ERROR
- Definition The feedback signal becomes higher than 4.2 volts (rms) for 1.0 second when
the exposure lamp is on.
The feedback signal becomes higher than 1.0 volt (rms) for 1.0 second when
the exposure lamp is off.
- Possible Causes Exposure lamp open Thermofuse open Defective ac drive board
Defective main board Defective dc harness
CN114 on the main board or CN401 on the ac drive board is not correctly
connected.

CODE #12 EXPOSURE LAMP ERROR


- Definition The feedback signal falls below 0.5 volt (rms) for 1.0 second when the exposure
lamp is on.
The exposure lamp stays on for longer than 10 seconds.
- Possible Causes Defective ac drive board Defective main board

CODE #13 ZERO CROSS SIGNAL ERROR


- Definition The CPU does not receive the zero cross signal within 0.56 second.
- Possible Causes Defective main board Defective dc power supply board
Zero cross line open CN107 on the main board or CN202 on the dc power
supply board is not correctly connected.

CODE #21 SCANNER HOME POSITION ERROR


- Definition The scanner home position sensors output remains LOW (de-actuated) for 9
seconds after the main switch is turned on.
- Possible Causes Scanner home position sensor failure Defective scanner motor
Defective main board Defective dc power supply board
Incorrect scanner drive wire position
FU202 on the dc power supply board open (blown fuse).

CODE #22 SCANNER HOME POSITION ERROR


- Definition The scanner home position sensors output remains HIGH (actuated) for 1.0
second after the scanner starts.
- Possible Causes 1

FT 3013
Scanner

home position sensor failure Defective scanner motor


main motor Defective dc power supply board
Incorrect scanner drive wire position Defective dc harness
CN103 or CN105 on the main board is not correctly connected.
FU202 on the dc power supply board open (blown fuse).
Defective

CODE #40 OPTICS THERMISTOR ERROR


-DefinitionThe optics thermistor is open.
-Possible Cause Defective thermistor Defective main board
CN113 on the main board is not correctly connected.

CODE #52 FUSING WARM-UP ERROR


- Definition The temperature detected by the thermistor does not reach 150C within 45
seconds after the main switch is turned on.
- Possible Causes Thermistor position error Fusing lamp open Thermoswitch open
Defective ac drive board Defective main board Defective ac harness
CN114 on the main board or CN401 on the ac drive board is not correctly
connected.

CODE #53 FUSING OVERHEAT


- Definition The temperature detected by the thermistor becomes higher than 240C.
- Possible Causes Thermistor short Defective ac drive board
Defective main board Fusing harness shorted

CODE #55 FUSING THERMISTOR OPEN


- Definition The temperature value output by the thermistor does not reach 2C within 20
seconds after the main switch is turned on.
- Possible Causes Thermistor open Defective main board Defective ac drive board
Fusing lamp open Thermoswitch open Defective ac harness

ABNORMAL CONDITION IN TONER DENSITY DETECTION


- Problem The Auto ID indicator or the selected manual ID level blinks. (No SC Code is
indicated.)
- Definition If Vsg goes below 2.5 volts or Vsp goes above 2.5 volts five times in a row.
- Possible Causes Incorrect Vsg voltage Dirty ID sensor Low toner density
Defective ID sensor Defective main board