REPAIR INSTRUCTION
Issued by ROBERT BOSCH (AUSTRALIA) PTY. LTD.
A.B.N. 48 004 315 628
Incorporated in
Victoria

File:
Section:
Bulletin No:
Page:
Date:
Supersedes:

DISM
K - NHA
0008

1 of 25
Sept. 2003
0001 , Nov 1999

Subject : Two-spring Nozzle Holder Assembly


Testing and Repair
This bulletin addresses the repair / test procedure and spare parts requirements to ensure correct
servicing of the two-spring injector assembly.
The procedure must be followed to achieve the specified design operation of the injector
assembly.
The use of closer tolerances (plunger lift to port closing and plunger stroke) on nozzle replacement
means that opening pressure setting is not required for pressure stage 2.
Closer tolerances are achieved by way of a nozzle kit comprising:

1 = Nozzle
2 = Adapter plate
3 = Stop sleeve