You are on page 1of 3

ADVANCE QUALITY SOLUTIONS PTE LTD

RADIATION SAFETY DISTANCE DIAGRAM

NOTE:
SOURCE

: IRIDIUM 192

RADIATION

: GAMMA RAY

CENTER

: SOURCE / PROJECTOR / CAMERA

CIRCLE IS THE BARRICADE DISTANCE NEED TO COVER WHILE DOING RT BASED ON THE SOURCE STRENGTH.
Prepared By
M. JAYASEELAN
Page 1 of 3

3
2
4

13

12
6

11
7

8
10
9

Page 2 of 3

Circle

Source Strength in Curies (Iridium 192)

Unshielded Distance in direction of


Beam

Tungsten Collimated Distance in direction of


Beam

( Radius of circle in Meter )

(Radius of circle in Meter)

13

70

216.00

33.23

12

65

208.20

32.00

11

60

200.00

30.77

10

55

191.50

29.46

50

182.50

28.07

45

173.20

26.65

40

163.30

25.10

35

152.75

23.50

30

141.40

21.75

25

129.00

19.85

20

115.50

17.76

15

100.00

15.53

10

81.65

12.56

Page 3 of 3