4 mm thick riser :
m
(kg/m3)
900
OD=
1.0668
cor=
t=
0.0254
st=
7850
con=
1340
sw=
1030
tcon =
0.018
tcor=
0.0025
weight of pipe=
652.59777 kg/m
0.6525977731 T
weight of corrosion
allowance=
7.5614786 kg/m
weight of concrete=
82.613067 kg/m
742.77232 kg/m
7283.62536151 N/m
weight of buoyancy=
993.17229 kg/m
9739.0475158 N/m
submerged weight=
-250.39997 kg/m
-2455.4221543 N/m
2.89 kg/m
1.601 kg/m
28.33934 N/m
15.699406 N/m
6.3993737634 kN
Weight of umblical:
In air(empty)
Submerged
1608 N/m
submerged weight=
942.524 N/m
Total weight:
In air:
Submerged weight:
8920 N/m
-1497 N/m
Wt of pipe =
Pi * (D-t)*t*Density (steel)
WCC =
WConc =
Wair =
1+2+3
Wbuoy =
Wsub=
4'-5
INPUT:
OUTER DIA.(Ds)
THICKNESS(ts)
density of steel(st)
concrete thickness(tconc)
density of concrete(conc)
corrosion thickness(tcc)
density of corrosion coating(cc)
% of water absorption
density of water(w)
cutback length(Lcb)
concrete bevel(Cb)
density of field joint(fj)
joint length(Lj)
1.0668
0.0212
7850
0.075
3044
0.025
940
0.05
1025
0.35
0.785
1025
12.5
m
m
kg/m3
m
kg/m3
m
kg/m3
kg/m3
m
(1in1)
kg/m3
m
1.0244
1.1168
1.2668
m
m
m
PIPE PROPERTIES:
Pipe internal diameter(Di)
Corrosion coating OD(Dcc)
Concrete coating OD(Dconc)
Weight calculation:
Weight of steel(Wst)
Weight of corrosin coating(Wcc)
Volume of concrete per unit length(Vconc)
Weight of concrete coating(Wconc)
Weight in air(Wa)
Buoyancy (B)
Submerged weight (Wsc)
546.6646
80.60479
0.280811
854.7895
1482.059
1291.903
204.5476
kg/m
kg/m
m2
kg/m
kg/m
kg/m
kg/m
17870.96
293.3446
-49.27006
kg/m
kg/m
kg/m
Waj
1449.203
kg/m
171.6915
kg/m
1016.49
kg/m
Flodded weight(Ww)
1 pound=0.454 kg
1kips = 4448.2216 N
1pcf=16.018kg/m3
1ksi=6.89Mpa
1Mpa=145.037psi