CABLE TYPES

CABLE SIZES

SPECIFICATION

CONDUCTORS
Material

INSULATION
Material
Colour Masterbatch

CORE IDENTIFICATION
No. of cores Core Colours

5467

FILLERS

BICC

Material

Material
Functions

Material

(Cables as per BS 6724)

Material

BICC

(1) XLPE insulation Ultra-violet (UV) colour masterbatch

(2) Polypropylene/PETP tape over the laid up cores

(3) Fillers

(4) Special requirements

our smoke master cable cataloge)

(g)

For protection against solvent penetration & corrosive attack cable with lead sheath can be offered.
(For details on lead sheath cables refer our lead sheath power, control and auxilary cable catalogue)

SHEATH DAMAGE

BICC

MINIMUM INSTALLATION RADIUS

Type of Cable

Overall Diameter (D)

Minimum internal
radius of bend

CONNECTORS

OVERHEAD TERMINATIONS

ARMOURED SINGLE CORE CABLES FOR AC OPERATION

magnitude

BICC

16 to 28

IEE wiring regulation

BICC

Formula:- Vd
amperes, L

metres, mV

24

26

26
following example.

BICC

Example 2:

26

Example 3:

26

Example 4:
2

2
26

10

BICC

RATING FACTORS FOR GROUND TEMPERATURE

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOIL


(AVERAGE VALUES)

BICC

11

RATING FACTORS FOR DEPTH OF LAYING


(TO CENTRE OF CABLE OR TREFOIL GROUP OF CABLES)

GROUP RATING FACTORS FOR CIRCUITS OF THREE SINGLE CORE CABLES IN TREFOIL
OR LAID FLAT TOUCHING, IN HORIZONTAL FORMATION

12

BICC

GROUP RATING FACTORS FOR MULTICORE


CABLES IN HORIZONTAL FORMATION

RECOMMENDED DUCT DIMENSIONS AND CABLE SIZES

RATING FACTORS FOR GROUND TEMPERATURE

BICC

13

RATING FACTORS OF VARIATION IN THERMAL RESISTIVITY OF


SOIL (AVERAGE VALUES)

RATING FACTORS OF DEPTH OF LAYING (TO CENTRE OF DUCT OR


TREFOIL GROUP OF DUCTS)

GROUP RATING FACTORS FOR SINGLE CORE CABLES IN TREFOIL SINGLE WAY DUCTS,
HORIZONTAL FORMATION (AVERAGE VALUES)

14

BICC

GROUP RATING FACTORS FOR MULTICORE CABLES IN SINGLE WAY DUCTS,


HORIZONTAL FORMATION (AVERAGE VALUES)

RATING FACTORS FOR OTHER AMBIENT AIR TEMPERATURES

DEFIND CONDITIONS OF INSTALLATION


16 to 28

BICC

15

Conductor Size

Short circuit ratings for 1 second in KA


Copper

Aluminium

Conductor

Conductor

FAULT CURRENT KILOAMPERES

mm

FAULT CURRENT KILOAMPERES

DURATION OF SHORT CIRCUT IN SECONDS

DURATION OF SHORT CIRCUT IN SECONDS

16

BICC

XLPE INSULATED CABLES


ARMOUR FAULT CURRENTS TO EARTH
(FOR A FAULT DURATION OF 1 SECOND)

15 and 27
.
Values based on IEC 60502-1

BICC

17

DIMENSION AND WEIGHTS

STRANDED COPPER & ALUMINIUM CONDUCTORS - SINGLE CORE CABLES

UNARMOURED AND ARMOURED, PVC SHEATHED CABLES

15

18

BICC

CURRENT

R AT I N G S

(AC)

STRANDED COPPER & ALUMINIUM CONDUCTORS - SINGLE CORE CABLES


ARMOURED PVC SHEATHED CABLES

600/1000 V

Stranded Copper Conductors


Nominal
area of
conductor

Stranded Aluminium Conductors

Approximate voltage drop


per ampere per metre

Current Ratings

In single
3D
Ground
way
Installed
ducts
in air
mV
amps
amps
235
222
0.87

Table 16
Approximate voltage drop per
ampere per metre

Current Ratings

50

235

0.93

0.87

175

In single
way
ducts
amps
180

1.40

1.60

1.40

70

290

280

285

0.62

0.70

0.62

220

220

207

0.98

1.00

0.98

95

345

330

346

0.47

0.56

0.47

260

260

252

0.72

0.79

0.74

mm

Direct in
ground
amps

Duct

Air

mV

mV

Direct in
ground
amps

3D

Installed
in air
amps
162

Ground

Duct

Air

mV

mV

mV

120

390

370

402

0.39

0.48

0.39

295

295

292

0.58

0.66

0.60

150

435

405

463

0.33

0.43

0.33

330

330

337

0.48

0.57

0.49

185

490

440

529

0.28

0.39

0.28

375

365

391

0.39

0.49

0.41

240

560

500

625

0.24

0.35

0.24

435

410

465

0.31

0.42

0.34

300

630

550

720

0.21

0.32

0.21

490

455

540

0.27

0.38

0.29

400

700

580

815

0.195

0.30

0.195

540

480

625

0.35

0.38

0.25

500

770

620

918

0.180

0.28

0.180

580

510

714

0.31

0.35

0.22

630

840

670

1027

0.170

0.26

0.170

630

540

801

0.28

0.32

0.20

800

888

692

1119

0.165

0.25

0.165

1000

942

735

1214

0.155

0.24

0.155

UNARMOURED PVC SHEATHED CABLES

600/1000 V

mm2

Aluminium Conductors

Stranded Copper Conductors

Nominal
area of
conductor

Approximate voltage drop


per ampere per metre

Current Ratings
Direct in
ground
amps

In single
Ground
3D
way
Installed
ducts
in air
mV
amps
amps
0.85
209
240

Table 17

Duct

Air

mV

mV

Approximate voltage drop


per ampere per metre

Current Ratings
Direct in
ground
amps

In single
3D
Ground
way
Installed
ducts
in air
mV
amps
amps
180
1.40
159

Duct

Air

mV

mV

50

230

0.93

0.87

175

1.50

1.45

70

285

295

268

0.61

0.70

0.61

215

220

206

0.98

1.10

0.98

95

335

345

326

0.45

0.56

0.45

255

260

253

0.71

0.79

0.73

120

385

395

379

0.36

0.48

0.37

295

300

296

0.57

0.66

0.59

150

435

445

436

0.31

0.43

0.31

325

335

343

0.47

0.57

0.47
0.39

185

490

500

500

0.26

0.39

0.26

370

375

395

0.39

0.49

240

570

580

590

0.22

0.35

0.22

430

440

471

0.31

0.42

0.32

300

650

650

681

0.19

0.32

0.195

490

510

544

0.26

0.38

0.27

400

740

750

793

0.17

0.30

0.175

550

570

638

0.36

0.38

0.23

500

840

850

904

0.16

0.28

0.160

620

640

743

0.33

0.35

0.20

630

960

960

1033

0.15

0.26

0.150

690

730

849

0.28

0.32

0.185

800

1120

1130

1179

0.15

0.25

0.145

1000

1300

1320

1323

0.14

0.24

0.140

Direct in ground - Trefoil touching


Single way ducts - ducts touching
Spacing in air - As shown above (D = Cable diameter)
Non magnetic wire armour bonded at both ends

BICC

Installation conditions for above ratings:


Ambient air temperature:30C
Ground temperature: 15C
Depth of laying:0.5 m, Soil thermal resistivity: 1.2C m/W
Maximum conductor operating temperature at rated
current is 90C, For rating factors see Tables 2 to 6 and 8 to 12

19

DIMENSION AND WEIGHTS

STRANDED COPPER & ALUMINIUM CONDUCTORS - TWO CORE CABLES

UNARMOURED AND ARMOURED, PVC SHEATHED CABLES

20

18

BICC

CURRENT RATINGS (AC)


STRANDED COPPER & ALUMINIUM CONDUCTORS - TWO CORE CABLES
ARMOURED PVC SHEATHED CABLES

600/1000 V

Stranded Copper Conductors

Nominal
area of
conductor
mm2

Aluminium Conductors

Approximate
voltage drop
per ampere
per metre

Current Ratings

Direct in
ground
amps

In single
way
ducts
amps

Installed
in air
amps

Table 19
Approximate voltage drop
per ampere per metre

Current Ratings

Direct in
Ground / Duct / Air
ground
amps
mV

In single
way
Installed
ducts
in air
amps
amps

16

140

115

115

2.90

25

180

145

152

1.90

135

110

112

Ground / Duct / Air


mV

3.10

35

215

175

188

1.35

165

130

138

2.20

50

255

210

228

1.00

195

155

166

1.65

70

315

260

291

0.69

240

195

211

1.15

95

381

313

354

0.52

288

237

254

0.84

120

410

344

410

0.42

150

472

384

472

0.35

185

539

432

539

0.29

240

632

504

636

0.24

300

708

560

732

0.21

UNARMOURED PVC SHEATHED CABLES

600/1000 V

Stranded Copper Conductors


Current Ratings
Nominal
area of
conductor
mm2

Direct in
ground
amps

In single
way
ducts
amps

Installed
in air
amps

Table 20

Aluminium Conductors

Approximate
voltage drop
per ampere
per metre

Approximate voltage drop


per ampere per metre

Current Ratings

Direct in
Ground / Duct / Air ground
amps
mV
2.90

In single
Installed
way
in air
ducts
amps
amps

Ground / Duct / Air


mV

16

140

115

115

25

180

140

149

1.90

135

105

108

3.10

35

215

170

185

1.35

165

130

135

2.20

50

255

205

225

1.00

195

150

164

1.65

70

315

255

289

0.69

240

195

211

1.15

285

235

257

0.84

95

380

311

352

0.52

120

410

344

410

0.42

150

473

384

473

0.35

185

542

432

542

0.29

240

641

504

641

0.24

300

741

560

741

0.21

Direct in ground - Cables touching


Single way ducts - ducts touching
Note: Unarmoured cables are as per IEC 60502 - 1

BICC

Installation conditions for above ratings:


Ambient air temperature:30C
Ground temperature: 15C
Depth of laying: 0.5 m
Soil thermal resistivity: 1.2C m/W
Maximum conductor operating temperature at rated current is 90C
For rating factors see Tables 2 to 6 and 8 to 12

21

DIMENSIONS AND WEIGHTS

STRANDED COPPER & ALUMINIUM CONDUCTORS


THREE CORE CABLES
UNARMOURES AND ARMOURED, PVC SHEATHED CABLES

21

(1)
(2) For current ratings & voltage drop data, please refer table 24 & 25 on page 25.

22

BICC

DIMENSIONS AND WEIGHTS

STRANDED COPPER & ALUMINIUM CONDUCTORS


FOUR CORE CABLES
UNARMOURED AND ARMOURED, PVC SHEATHED CABLES

22

(1)
(2) For current ratings & voltage drop data, please refer table 24 & 25 on page 25.

BICC

23

DIMENSIONS AND WEIGHTS

STRANDED COPPER & ALUMINIUM CONDUCTORS


FOUR CORE CABLES WITH REDUCED NEUTRAL CONDUCTOR
UNARMOURED AND ARMOURED, PVC SHEATHED CABLES

19.5

25.4

1802

22.1

28.0

2179

24.5

30.7

1700

2762

28.1

35.4

2327

3848

31.4

38.9

2772

4886

34.9

42.7

3304

5998

38.6

47.6

4311

7675

42.8

52.2

4990

9071

49.0

58.7

6076

11403

53.2

63.1

7044

13694

61.7

73.4

9511

18262

68.8

83.9

11200

22000

For current ratings & voltage drop data, please refer table 24 & 25 on page 25.

24

BICC

CURRENT RATINGS (AC)


STANDARD COPPER & ALUMINIUM CONDUCTORS - THREE CORE CABLES,
FOUR CORE CABLES & FOUR CORE CABLES WITH REDUCED NEUTRAL CONDUCTOR
ARMOURED PVC SHEATHED CABLES

600/1000 V

Stranded Copper Conductors

Nominal
area of
conductor

Direct in

mm2

In single

amps

amps

in air
amps

Ground / Duct / Air


mV

Approximate voltage drop

Current Ratings

per ampere per metre

Installed

ground way ducts

Stranded Aluminium Conductors

Approximate voltage drop

Current Ratings

Table 24

per ampere per metre

Direct in

In single

Installed

ground

way ducts

in air

amps

amps

amps

Ground / Duct / Air


mV

16

115

94

99

2.5

89

72

74

25

150

125

131

1.65

115

94

98

2.7

35

180

150

162

1.15

135

110

120

1.95
1.45

4.2

50

215

175

197

0.87

165

135

145

70

265

215

251

0.60

200

165

185

0.97

95

315

260

304

0.45

240

200

224

0.72

120

360

300

353

0.37

275

230

264

0.58

150

405

335

406

0.30

310

255

305

0.47

185

460

380

463

0.26

350

295

350

0.39

240

530

440

546

0.21

410

340

418

0.31

300

590

495

628

0.185

460

385

488

0.26

400

667

570

728

0.165

520

443

562

0.25

500

720

605

800

0.165

561

470

618

0.20

UNARMOURED PVC SHEATHED CABLES

600/1000 V

Stranded Copper Conductors

Nominal
area of
conductor

Current Ratings

mm

16

Approximate voltage drop

Approximate voltage drop

Current Ratings

per ampere per metre

Direct in
2

In single Installed

ground way ducts

in air

amps

amps

amps

120

93

100

Ground / Duct / Air


mV
2.5

Table 25

Stranded Aluminium Conductors


per ampere per metre

Direct in

In single

Installed

ground

way ducts

in air

amps

amps

amps

89

72

Ground / Duct / Air

77

mV
4.2

25

145

125

127

1.65

115

92

97

2.7

35

180

145

158

1.15

135

110

120

1.95

50

215

175

192

0.87

165

135

146

1.45

70

265

215

246

0.60

200

165

187

0.97

95

315

255

298

0.45

240

195

227

0.72

120

365

300

346

0.37

275

225

263

0.58
0.47

150

405

330

399

0.30

310

255

304

185

465

380

456

0.26

350

290

347

0.39

240

540

440

538

0.21

415

340

409

0.31

300

600

500

621

0.185

465

385

471

0.26

400

675

575

741

0.165

523

443

570

0.25

500

730

610

814

0.165

565

470

626

0.20

Direct in ground - Cables touching


Single way ducts - ducts touching
Note: (1) Unarmoured cables are as per IEC 60502 - 1.
(2) Current rating values are for main power conductor.

BICC

Installation conditions for above ratings:


Ambient air temperature:30C
Ground temperature: 15C, Depth of laying:0.5 m
Soil thermal resistivity: 1.2C m/W
Maximum conductor operating temperature at rated current is 90C
For rating factors see Tables 2 to 6 and 8 to 12

25

CURRENT RATINGS (AC) AND VOLT DROPS


STRANDED COPPER CONDUCTORS
THREE AND FOUR CORE ARMOURED, PVC SHEATHED CABLES

26

26

BICC

DIMENSIONS AND WEIGHTS


ARMOURED PVC SHEATHED CABLES

400

27

27.5

1604

30.4

2023

32.8

2448

28.9

36.2

3164

32.6

40.1

4033

35.8

43.5

5004

39.1

47.9

6308

42.4
46.0

51.4

7353

55.4

8711

51.2

60.7

10764

56.2

66.1

12956

61.4

71.7

15760

CURRENT RATINGS
ARMOURED PVC SHEATHED CABLES

28

3D

Installed
in air
amps

400

641

512

704

As per IEC 60502-1

BICC

27

28

BICC

Conductor and

BSEN 60228

SINGLE AND MULTICORE CABLES HAVING WIRE ARMOUR

29

BICC

29

Ducab Factory, Mussafah (M1)


P.O. Box 9171, Abu Dhabi, U.A.E.
Tel: +971 2 502 7777, Fax: +971 2 502 7755
E-mail: ducab@ducab.com

Ducab Factory, Mussafah (M2)


P.O. Box 9171, Abu Dhabi, U.A.E.
Tel: +971-2 550 0774, Fax: +971 2 550 0979
E-mail: ducab@ducab.com

Ducab - Abu Dhabi Sales Ofce (ADSO)


P.O. Box 9171, Abu Dhabi, U.A.E.
Tel: +971 2 550 0774, Fax: +971-2 502 7890
E-mail: ducab@ducab.com

Ducab - Northern Emirates Sale Ofce (NESO)


P.O. Box 683, Dubai, U.A.E.
Tel: +971 4 266 7400, Fax: +971 4 266 8955
Email: ducab@ducab.com

Ducab - Oman
P.O. Box 3542, 112 Ruwi, Muscut, S. of Oman
Tel: +968 245 651 78, Fax: +968 245 643 02
Email: ducabomn@omantel.net.om

BICC MET W.L.L.


P.O. Box 11413, Manama, Kingdom of Bahrain
Tel: +973 177 497 61, Fax: +973 177 280 27
Email: biccmet@batelco.com.bh

Ducab - Qatar
Tel: +974 3209077
P.O. Box 23209, Doha, Qatar
Email: dqsales@ducab.com

Ref No: Z 0008/04/08 (2000 copies)